Explosion-proof Immersion Heater Type D-8660

Similar documents
Finned Tube Air Heaters Type WD/GG (RVS)

Fan Heaters Type VLEx

Sinus Jevi (Explosion-Proof) Condens Heaters

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Flange immersion heaters

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

INSTRUCTION MANUAL (ATEX / IECEx)

Circulation Heaters Selection Guidelines

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Flameproof Manual Call Points Series MCP

Circulation Heaters Selection Guidelines

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Screw plug immersion heaters

INSTRUCTION MANUAL (ATEX / IECEx)

Survey of electrical equipment installed in hazardous areas on tankers

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Manual Power relay SR853

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

EXHEAT Industrial Standard Products

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

FX5 Series Explosion-Proof Electric Air Heaters

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

HEAT. Industrial Ltd. Standard Products

OPTIBAR DP 7060 Supplementary Instructions

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Electrical Installations Design, Selection, Erection and Inspection

IECEx Certificate of Conformity

ATEX JEVI A/S ISO 9001 A12295 EXPLOSION PROOF ELECTRICAL HEATERS FOR INDUSTRIAL AND OFFSHORE APPLICATIONS

Our. Heaters. for your Projects

UL HAZARDOUS LOCATIONS SERVICES

IECEx Certificate of Conformity

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

LTFX Electric Tank Immersion Heaters Installation Instructions

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Integrated Solutions Low Voltage Systems

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

SUMMARY. Page 12. Selecting an immersion heater. Page 42. Junction boxes for immersion heaters. Page 59. Page 73. Page 79

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Flameproof Manual Call Points Series MCP

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Agency Certifications, Recognition and Approvals

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Exp, pressurized systems

Dräger Polytron 5100 EC Detection of toxic gases and vapors

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

IECEx Certificate of Conformity

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Flanged Immersion Heaters

IECEx Certificate of Conformity

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Flanged Immersion Heaters

Ar-Mite TM Low Flow Armored Flowmeter

Agency Certifications, Recognition and Approvals

Flanged Immersion Heaters

Operating Instructions

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

1. GENERAL TECHNICAL INFORMATION

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

IECEx Certificate of Conformity

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Cable Glands DB Series: Drain, Breather Valves and Unions

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

FE1 Explosion-Proof Electric Air Heaters

Hazardous Area Portable Fan Heater The Bulldog

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

IECEx Certificate of Conformity

INSTRUCTION & SERVICE MANUAL

Approvals, Certificates and Conditions

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Switches compliant with ATEX directive

High bay LED lighting fixture

Dual certification! Air handling units for potentially explosive atmospheres

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

Hazardous Area Portable Fan Heater The Bulldog

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Strip/Clamp-On Heaters

SCREWPLUG HEATERS. immersion heaters

Performance Data. curus Component Recognized; File No. E IP 20

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Temperature Measurement Transmitters for field mounting

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

( )

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Transcription:

Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to protect the environment against gas-explosions, caused by sparking by electrical connections of the heating elements and control devices. Liquids Gasses Solids Spaces Resistors Sinus-Jevi Electric Heating B.V. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com

Gas and Dust flame-proof immersion heater type D-8660 For hazardous areas, Sinus Jevi has developed explosionproof Ex de heating equipment, designed and manufactured in accordance with EN-IEC 60079-0, EN-IEC 60079-1, EN 60079-7, EN-IEC 60079-31 certified by the independent testing institute ISSeP. The certificates cover zone 1 and zone 2 for hazardous areas. Gas groups II A, II B and II C and temperature classes T6-T1. Dust group Ex tb zone 21. The flame-proof (d) enclosures have been designed for non save areas to protect the environment against gasexplosions, caused by sparking by electrical connections of the heating elements and control devices. Several types of enclosures for immersion heaters, flanged or screwed, have been described on the next pages. Each type covers a range of a maximum number of installed hairpin shaped heating elements and giving a range of installed capacities. The screwed types for dimensions up to 3. The terminal enclosures have a IP66 degree of protection. Standard the enclosure is coated with two layers, a zinc silicate primer and a top coating. Other coatingsystems on request. All heaters are standard internal wired on terminals. The maximum temperature for the terminal enclosure during operation is 80 C (based on maximum 50 C ambient temperature). If cable entry exceeds 70 C, high temperature cables must be used. The required minimum distance between enclosure and connection flange, to ensure the temperature limit of 80 C in the enclosure, is listed in the following table as a function of temperature classes. Maximum number of cable entries: 3 pcs M25/M20 Marking ATEX Ex II 2 G D Ex de IIC T6-T1 Gb EN/IEC 60079-1 Ex tb IIIC T110 C Db EN/IEC 60079-31 Type D-8660 Ex II 2GD - Ex de IIC T6-T1 Gb - Ex tb IIIC T110 C Db Type Flange Elements no of max. Immersion Maximum Maximum Maximum 150 LBS length (mm) capacity in capacity in capacity in Ø8.5 Ø10.2 Ø12.7 Ø16 oil (Watt) water (Watt) gases (Watt) D-8660-F031-05 3 500 1.500 4.500 1.200 D-8660-F031-07 3 750 2.500 7.000 2.000 D-8660-F031-10 3 1.000 3.500 10.000 3.000 D-8660-F031-15 3 1.500 5.500 15.000 4.500 D-8660-F031-20 3 2.000 7.000 18.000 6.000 D-8660-F031-25 3 2.500 9.000 18.000 7.500 D-8660-F031-30 3 3.000 11.000 18.000 9.000 D-8660-H061-05 4 500 3.000 9.000 2.400 D-8660-H061-07 4 750 5.000 14.000 4.000 D-8660-H061-10 4 Number of elements 1.000 7.000 20.000 6.000 D-8660-H061-15 4 depend on diameter, pitch and 1.500 10.500 25.000 9.000 material D-8660-H061-20 4 2.000 14.000 30.000 12.000 D-8660-H061-25 4 2.500 18.000 35.000 15.000 D-8660-H061-30 4 3.000 22.000 36.000 18.000 D-8660-J121-05 6 500 6.000 18.000 4.800 D-8660-J121-07 6 750 10.000 28.000 8.000 D-8660-J121-10 6 1.000 14.000 40.000 12.000 D-8660-J121-15 6 1.500 21.000 50.000 18.000 D-8660-J121-20 6 2.000 28.000 60.000* 24.000 D-8660-J121-25 6 2.500 36.000 60.000* 30.000 D-8660-J121-30 6 3.000 44.000 60.000* 36.000 * Limitation power by cable entry T to be clamped on element - Flange connection with tubular type heating element 2

Description Suitable for heating of fluids both liquids and gases and also solids. The heater consists of a certified flameproof enclosure D-8660, containing: - certified electric heating elements (Ex e II) tubular, ceramic or cartridge heating elements. - one manually protective thermostat with manual reset or one thermocouple or pt100 as a safety device. Thermocouple and pt100 are only applicable in combination with a temperature controller installed in a control panel. - one control thermostat for fluid temperature. Alternatively, one thermocouple or pt100. - threaded holes for cable entries and/or plugs of a certified flameproof model Ex d II B or Ex d II C Gb. The flame-proof enclosure has been built up out of a seamless body, a top cover and base plate. Each cover and base plate has been provided with 6 screw thread windings with a total length of 18 mm. The connection length of the threaded joint between cover or base plate and body should always be 5 thread windings minimum. The cover has been locked with an M4 screw and the base plate with an M6 screw. In the base plate of the enclosure spacer tubes can be welded in which the heating elements are brazed or welded. Temperature class Distance enclosure to heater (T) T6 85 C 50 mm T5 100 C 75 mm T4 135 C 100 mm T3 200 C 150 mm T2 300 C 200 mm T1 450 C 250 mm Technical specification - Tubular heating elements with a diameter of Ø8.5 mm up to and including Ø16 mm and cartridge heating elements of Ø12.5 mm up to including Ø31.5 mm can be applied, also ceramic elements from Ø26 mm up to including Ø46 mm. - Material of the enclosure: carbon, low alloy steel, or ferrous steel. - Material of heating elements: stainless steels AISI 304, AISI 321, AISI 316, AISI 904L, Inconel 600, Incoloy 800, Incoloy 825, Titanium, SMO, Copper alloy or Nickel alloy. - Degree of protection of the enclosure: IP66. - The maximum allowable energy-dissipation of the heating elements has been based on a maximum Watt density, determined by the temperature class, type of medium and process conditions. The temperature setting of the thermostat, thermocouple or pt100, as stated in the EC type Examination Certificate, is applicable only for heaters immersed into a hazardous fluid flow. If the heater has not been immersed into a hazardous fluid but forms a part of an apparatus located in a hazardous zone, the temperature setting has to prevent the maximum temperature of the outside of the apparatus to exceed the temperature according to the temperature classification. Certification Certification number ISSeP 08ATEX009X for heaters in zone 1 & 2 and gas group IIC Certification number ISSeP 10ATEX039X for heaters in zone 2 & gas group IIA and IIB T to be clamped on element Threaded boss from 1½ G BSP up to 3 G BSP with tubular type heating element. 3

Flame-proof immersion heater type D-8660 for high working temperatures Flame-proof immersion heaters with retractable ceramic core elements. Single or multi core heaters. For horizontal installation (vertical installation available on request). The ceramic core elements can be withdrawn for inspection or replacement without having to drain the system. - Ambient temperature -30 C - +50 C - The maximum allowable voltage is 690 Volt. Marking ATEX Ex II 2 G D Ex de IIC T6-T1 Gb EN/IEC 60079-1 Ex tb IIIC T110 C Db EN/IEC 60079-31 T to be clamped on element Control thermostat - Flange connection with cartridge or retractable ceramic heating element. T to be clamped on element Control thermostat - Screw connection with cartridge or retractable ceramic heating element. 4

Gas and Dust flame-proof immersion heater type D-8660 VARIATION for relative low working temperatures Description The heater serie D-8660 variation is designed to heat a wide range of liquids, gases and solids. The heater consists of a certified flameproof enclosure Ex de II C, certified electric heating elements Ex e II and a manually reset protective safety device. Unheated length heating elements into the medium is 30 mm minimum. The surface loading of the elements in the heater is determined by the thermal characteristics of the fluid or gas being heated and its operating temperature and pressure. The heaters are designed to operate within an ambient temperature range of -30 C to +50 C. Heating elements The heater consists of certified electric heating elements Ex e II which can be tubular heating elements with a diameter up to Ø16 mm or cartridge heating elements up to a diameter of Ø31.5 mm or retractable ceramic core elements Ø26 mm - Ø46 mm placed in a metal sheath with welded end plate. Voltage supply up to 690 Volt. Mounting Threaded boss or flange connection in carbon steel or high alloy steel. Set point safety thermostat Set point on safety thermostat in medium: Temperature class T1 to T4: 110 C Temperature class T5: 90 C Temperature class T6: 75 C If the cable entries exceed 70 C suitable high temperature cabling methods must be used. A warning label on the outside of the enclosure next to the cable gland showing the maximum allowable temperature is recommended. By a working temperature of more than 90 C the terminal enclosure will be at a distance from the heater. See table on page 3. Temperature safety Minimum of 1 over temperature thermostat or thermocouple or pt100 must be installed for guarding flange, plate or screw head and junction box temperature and must be either: - Manually reset at the control panel by key switch or special tool - Manually reset unit inside the terminal enclosure (klixon) - Possibly with added manually reset unit on the highest surface temperature of the apparatus When the electric heater type D-8660 and his variation does not have a temperature regulation of its own, the process medium temperature for each combination must be regulated with a seperate flameproof control thermostat, thermocouple or Pt100 and a seperate safety thermostat, thermocouple or Pt100 with manual reset. Both devices shall guarantee the temperature limit and the temperature class. Special note The end user must ensure that the heating elements are always inserted into the liquid or gas. The end user must ensure that there is always a protection against an incorrect direction of flow (e.g. an one way valve). The lowest temperature of the liquid or gas flow is always at the end where the terminal enclosure is situated. Terminal enclosure The terminal enclosure can be either direct on or stand off depending on the process temperature. Set point on safety thermostat inside the terminal enclosure: Temperature class T1 to T4: 90 C Temperature class T5: 85 C Temperature class T6: 70 C Marking ATEX Ex II 2 G D Ex de IIC T6-T1 Gb EN/IEC 60079-1 Ex tb IIIC T110 C Db EN/IEC 60079-31 max. 150 - Threaded boss from 1½ G BSP up to 3 G BSP with tubular type heating element. 5

Flame-proof immersion heater type D-8660 VARIATION for low working temperatures max. 150 max. 150 max. 150 - Flange connection with tubular heating element. - Threaded boss from 1½ G BSP up to 3 G BSP with cartridge or retractable ceramic heating element. - Flange connection with cartridge or retractable ceramic heating element min. 50 Control thermostat 150 - Flanged connection with a number of retractable ceramic heating elements. 6

Accessories Cover removal tool for immersion heater type D-8660 For easy removing the lid from the junction box. Article number Material 953 000 000A AISI 304L NOTES 7

Sinus is one of the pioneers in the field of explosion proof heating equipment, today we are still operating at the forefront. We manufacture according to ATEX as well as IECEx and EAC directives. For the production of Ex-proof equipment a PQAN (Product Quality Assurance Notification) is issued by TUV-Nord. Our ISO-9001 and ISO-14001 systems are also monitored by this organisation. 953B.1101E 10-14 Sinus-Jevi Electric Heating B.V. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com