Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Similar documents
GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Flameproof Manual Call Points Series MCP

Explosion Proof Manual Call Points Series MCP

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Flameproof Manual Call Points Series MCP

OPERATING AND INSTALLATION

Explosion Proof Combination Signal db (A) / 5 Joule

Integrated Solutions Low Voltage Systems

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION & SERVICE MANUAL

Hazardous Area Signalling

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX / IECEx)

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Industrial Signalling

Flameproof Manual Call Points

Beacons, Lights & Strobes

Industrial Signalling. Signalling Solutions

YO3 - YO4 / YL4 - YO5 / YL5

your dust explosion protection experts

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

INSTRUCTION MANUAL (ATEX / IECEx)

standards: standards:

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

ATEX. IECEx. culs GOST-R. VdS

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

INSTRUCTION MANUAL (ATEX / IECEx)

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

INSTRUCTION & SERVICE MANUAL

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

Our product range. Fire: Explosion proof Hazardous location and Industrial signals

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

UL HAZARDOUS LOCATIONS SERVICES

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

14300 MAINS SEPARATOR ALARM MANUAL

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

TX6831 Data Sheet. Features. Benefits

4) Intrinsic Safety Certification

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

DB4 Range - SPEAKERS - Up to 25 Watts

PRODUCT NEWS FLASHING BEACONS FOR RUGGED CONDITIONS IN HAZARDOUS AREAS NEW FX15 SERIES OF FLASHING SIGNAL LIGHTS FOR USE IN EX ZONE 1/2 AND 21/22

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

DB5 Intrinsically Safe Sounder Type DB-5

Fire Signalling. Signalling Solutions

TECHNICAL MANUAL EXPLOSION PROOF SOUNDER/ HORN & BEACON BHB 125/ BHB 150. Scope: EXcite USER MANUAL BHB 125 / BHB 150 Date: Page: Checked by: Rev.

INSTRUCTION MANUAL (ATEX / IECEx)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Smarter Signaling AUDIBLE/VISUAL SIGNALS

Universal Tank Alarm Type Installation, Operation & Maintenance

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Operating Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Fire Signalling. Signalling Solutions

The Signal Is Clear TM

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

Certification Supplement Manual

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Explosion-proof Immersion Heater Type D-8660

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

E2S Datasheet v10a

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Telephony & Communication

Excellence in Level Measurement

FlexSQUARE Square shaped beacons

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Safe & hazardous area. Industrial products catalogue

INSTRUCTION MANUAL A131 High Level Audible Warning System

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

ELECTRICAL EX EQUIPMENT

DICTATOR Hold-Open Systems for Hazardous Areas

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

DB1 Range - HORNS - Up to 103 db(a)

Half-Dome. the Design-Tower. Compact

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

SELECT-A-HORN/STROBE SERIES

Technical Manual for the Horn DB1P UL DB1HP UL

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Guide for hazardous areas

Temperature Measurement Transmitters for field mounting

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Main switch current K: with main switch (optional)

Solar Separator Alarm Type Installation, Operation & Maintenance

Transcription:

www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > Flash rate 1 per second > 32 selectable tones meeting international regulations > Sound selection via DIL switch > Lens guard and mounting bracket supplied as standard > Telephone initiate option available Yodalex range Combination audible and visual signal designed for use in hazardous or harsh environments. 14719E00 ATEX Class I (NEC 505) (NEC 506) Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x x x x For use in x x x x x x Explosion Protection Marking Gas explosion protection Dust explosion protection Certificates Other approvals Ex d IIB T4 (Ta -35ºC to +60ºC) Ex d IIB+H2 T4 (Ta -20ºC to +60ºC) Ex td A21 IP66 T135ºC (Ta -35ºC to +60ºC) Ex td A21 IP66 T135ºC (Ta -35ºC to +60ºC) E II 2 GD Ex d IIB T4 (T6 on request) E II 2 GD Ex d IIB+H 2 T4 (T6 on request) BAS 05.0086 X BAS 05.0087X Baseefa 02ATEX0212X Baseefa 02ATEX0222X Canada (CUL), Russia (GOST-R), USA (UL), Brazil (INMETRO) WebCode YL60A Combination Audible and Visual Signalling Devices /1

Selection Table Version Group Flash energy ATEX certification, UL certification, certification, GOST R certification, Note Rated operational voltage Lens colour Order number Art. no. Weight kg IIB + H 2 5 Joule 24 V DC amber YL60/C/D50/A/EU 205250 6.000 red YL60/C/D50/R/EU 205257 6.000 115 V AC amber YL60/C/L50/A/EU 205267 6.000 red YL60/C/L50/R/EU 205271 6.000 230 V AC amber YL60/C/N50/A/EU 205273 6.000 red YL60/C/N50/R/EU 205282 6.000 IIB + H 2 5 Joule 24 V DC amber YL60/B/D50/A/UL 205287 6.000 red YL60/B/D50/R/UL 205293 6.000 115 V AC amber YL60/B/L50/A/UL 205568 6.000 red YL60/B/L50/R/UL 205299 6.000 230 V AC amber YL60/B/N50/A/UL 205301 6.000 red YL60/B/N50/R/UL 212386 6.000 IIB + H 2 5 Joule 24 V DC amber YL60/C/D50/A/IN 210791 6.000 red YL60/C/D50/R/IN 209605 6.000 115 V AC amber YL60/C/L50/A/IN 212387 6.000 red YL60/C/L50/R/IN 212388 6.000 230 V AC amber YL60/C/N50/A/IN 205276 6.000 red YL60/C/N50/R/IN 205284 6.000 IIB + H 2 5 Joule 24 V DC amber YL60/C/D50/A/RU 212389 6.000 red YL60/C/D50/R/RU 205265 6.000 115 V AC amber YL60/C/L50/A/RU 212390 6.000 red YL60/C/L50/R/RU 205272 6.000 230 V AC amber YL60/C/N50/A/RU 212391 6.000 red YL60/C/N50/R/RU 212392 6.000 Variations in gas group, flash energy, voltage and lens colour are available, please use the table below to order /2 Combination Audible and Visual Signalling Devices

Selection Table Version YL60 Sounder/Strobe combination, devices acc. to specification Variations Type code: please fill in fields Gas group EU, IN and RU units IIB B IIB + H2 UL units C, D gas groups C Rated operational voltage B gas groups 24 V DC D 48 V DC F 115 V AC L 230 V AC N Flash energy Lens colour 5 Joule 50 amber red green opal blue clear yellow Certification ATEX UL Additions GOST-R activation AC voltages only telephone initiate C B A R G O B C Y EU UL IN RU TI Order Number YL60 / _ / / _ / _ / _ Combination Audible and Visual Signalling Devices /3

SW1 ON 12345 12345 SW2 ON Explosion Proof Combination Signal - 110 db (A) / 5 Joule Technical Data Electrical data Rated operational voltage Current consumption Schematic 24 V DC, 115 or 230 V AC 24 V DC 5 J, ATEX, UL, GOST 570 ma 115 V AC 5 J, ATEX, UL, GOST 200 ma 230 V AC 5 J, ATEX, UL, GOST 100 ma Standard DC alarm connection and sound signal selection 33 + 24 V DC Strobe 0 V Sounder Strobe +24 V DC Sounder Earth 30 TB1 X LK1 (0 V) LK2 (24 V DC) TB2 32 To next strobe Y TB3 31 Earth connection 40 Sound selection 39 Pressure unit Connector 27 To next sounder 14809E00 NOTE: Two stage alarm by third core. The two stage control always operates as follows: Strobe shown with common 0 V. The first stage sounds by supplying volts to a unit Line monitoring by reversal. via control switch X. This switch remains on and the Select alarm stage 1 on SW1. second stage signal is controlled by switching volts Select alarm stage 2 on SW2. to the third terminal via switch Y. AC alarm connection and sound signal selection 36 TB1 TB2 TB3 TB4 37 SW1 SW2 TB1 TB2 TB3 TB4 1 Control panel Sounder Strobe 34 N SW-A 35 Sounder 2nd stage 38 To next sounder and strobe 14810E00 Legend 1 = External power supply, provided by user 27 = Connections to additional sounder/horn 30 = Terminal blocks for incoming and outgoing wiring 31 = Internal earth terminal 32 = Connections to additional strobe/beacon 33 = Control voltage for strobe/beacon (connection to TB1), common voltage for both strobe/beacon and sounder/horn (connection to TB2), control voltage for sounder/horn (connection to TB2) 34 = Live voltage for sounder/horn (connection to TB1), live voltage for strobe/beacon (connection to TB2), common neutral for both strobe/beacon and sounder/horn (connection to TB3) 35 = Switch for second stage alarm 36 = Terminal blocks for incoming and outgoing wiring 37 = Dual in line sound selection switches, situated on reverse 38 = Connections to additional sounder/horn and strobe beacon 39 = Connecting socket used for pressure unit, situated on reverse of the PCB 40 = Dual in line sound selection switches, situated on reverse of PCB /4 Combination Audible and Visual Signalling Devices

Technical Data Acoustic data Volume 110 db (A) / 1 m Sound selection via DIL-switch Luminous Characteristics Flash rate 1/s Flash energy 5 J Lens colour amber, red, green, opal, blue, clear, yellow Ambient conditions Ambient temperature version IIB Europe T4-35... + 60 C T6-35... + 40 C IIB + H 2 Europe T4-20... + 60 C T6-20... + 40 C Mechanical data Material Enclosure aluminium, seawater resistant Horn ABS, flame retardant Globe polycarbonate Assembly parts stainless steel Degree of protection IP66, 4X Cable entries 2 cable entries, equipped with stopping plug (1x) and dust cap (1x) UL devices: equipped with M20 / 1/2 adapters (2x) Accessories and Spare Parts Designation Illustration Description Group Order number Art. no. WebCode Cable gland Note 14976E00 14742E00 14977E00 Compound Barrier Cable Glands Ex d and Ex e for all Types of Unarmoured Cables Compound Barrier Cable Glands Ex d and Ex e for all Types of Armoured Cables Cable Glands Ex d and Ex e for Unarmoured Cables Triton CDS Cable Glands Ex d and Ex e for all Types of Armoured Cables 14978E00 Approvals of cable entries have to be observed. IIB + H 2 and IIC IIB + H 2 and IIC Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations IIB IIB 8163/2-20- PXSS2K-M20 PX2K-M20 A2F-M20 T3CDS-M20 138888 8163J 138875 8163I 138772 8163A 138902 8163K 75 mm / 3 M8 420 mm / 16.5 145 mm / 5.7 13977E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Combination Audible and Visual Signalling Devices /5