OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Similar documents
Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

DETCON MODEL SERIES 700 GAS DETECTORS

Industrial Grade Gas Detection

Industrial Grade Gas Detection

Industrial Grade Gas Detection Detecting The Difference

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

3M Oldham OLCT 100. Description. Fixed Gas Detector

S5000 Gas Monitor. GMS5000.com

Fixed Gas Detectors Portable Gas Detectors Flame Detectors SmartWireless Control Solutions Gas Analyzers GF-00002A-EN

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SIL 2. Ultima X Series Gas Monitors CERTIFIED

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

OLC(T) 100 FIXED GAS DETECTOR

ULTIMA X5000. MSAX5000.com

Detection, Protection, Innovation

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 7000 Fixed gas detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

ALTAIR 5X Multigas Detector

3M Oldham MX 43 Controller

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Sieger Apex. Flexibility that meets your requirements

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

INSTRUCTION MANUAL Detcon Model IR-700

GasAlertMicroClip X3 Specifications

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

GAS PLUS ALARM SYSTEM

PROTÉGÉ ZM SINGLE GAS MONITOR

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

SUPREMATouch. Modular Fire & Gas Detection System

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

700 IR Series. Instruction Manual. Infrared Gas Detector for Combustible and CO 2 gases OLCT 700 OLCT 710. The Fixed Gas Detection Experts

INSTRUCTION MANUAL Detcon Model FP-700

GAS DETECTORS. When every second counts

Dräger Polytron 8000 Stationary gas detector (EC)

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Danfoss gas detection unit Type GD Heavy Duty

ALTAIR 5X Multigas Detector Product Specification

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 5700 IR Detection of flammable gases and vapours

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Lamp Supply (Recommended)

Recalibrate the way you look at gas detection

Toxic Gas Detection. Model F12. Toxic Gas Detection

Transmitters/Sensors. OLCT Series

Dependable Solutions for Gas Detection

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Model D12. Digital Gas Transmitter

700 TP Series. Instruction Manual. Hydrogen Sulfide Detector Solid State Sensor OLCT 700 OLCT 710. The Fixed Gas Detection Experts OLCT 700/710 TP

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Zareba Sensepoint Pro

Dräger Flame 2100 Flame Detection

Zareba System Overview

Dräger Polytron 8700 IR Detection of flammable gases and vapors

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

INSTRUCTION MANUAL Detcon Model IR-700

incontrol Systems Inc. Flame and Gas Detection

IGD.CO.UK

P R O D U C T D ATA S H E E T

Dräger Flame 2500 Flame Detection

INSTRUCTION MANUAL Detcon Model TP-624D

XNX Universal Transmitter

Better detection. Better protection. Fixed Gas & Flame Detection Product Overview - North America Region

For the Safety of Your

A New Standard of Excellence

Global Gas Detection and Monitoring Solutions

VENTIS PRO SERIES. Product Guide

Dräger PIR 3000 Detection of flammable gases and vapours

Warranty Registration

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Searchpoint Optima Plus

Operation & Maintenance Manual

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Transcription:

FIXED GAS DETECTION OLCT 700 Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. & 710 The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multilayered transient spike protection circuitry and 100% encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Series OLCT 700/710 intelligent sensor modules feature dual outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output. It is becoming increasingly important that safety systems meet the Safety Integrity Level (SIL) requirements of IEC 61508 and IEC 61511. The SIL rating can only be determined by considering the complete safety system. Certifications Better detection. Better protection. 316 SS Construction IP 66 Multi-Layer Surge Protection SIL2 Certified Environmentally Bulletproof

OLCT 700 & 710 Series OLCT 700/710 The Oldham SERIES OLCT 700/710 sensor modules are designed with this in mind and feature a new and unmatched level of pre-emptive fault diagnostics. Application variables like input voltage range, operating temperature range, maintenance schedule, detector reliability and output integrity are all monitored and reported via the 4-20 ma and RS-485 serial output. As a component of a SIL rated system, the Safe Failure Fraction (SFF) of Oldham SERIES OLCT 700/710 sensors are designed to meet the requirements for any SIL 2 rated system. SERIES OLCT 700's sensors utilize distinctive gas detection technologies to satisfy a wide range of industrial applications that require monitoring of, toxic and flammable gases. Sensors for Hydrogen Sulfide CHEMFET MOS Solid State Technology Harsh and Extreme Locations Wide & Humidity 5-year Sensor Sensors for Combustible Gas Catalytic Technology Non-selective Combustible Gas Sensor 2-year Sensor Rugged Construction Sensors for Carbon Dioxide Infrared Technology Selective CO2 Gas Sensor 2-year Sensor Infrared Technology Combustible Hydrocarbon Gas Sensor 2-year Sensor Scrolling Full Message/Text Display mdj N wbol mdj O pm^k Pre-emptive Fault Diagnostics input voltage range Auto Zero/Auto Span Sequence 0% operating temperature range detector signal amplitude output signal loop integrity autospan opj reminder QUR= RS-485 Output & ma Output auto zero zero complete auto span apply 50% LEL span ok sensor life 100% remove gas span complete

OLCT 700 & 710 Anatomy of the OLCT 700/710 Junction Box (OLCT 710 only) Surge Protection Termination Module (available on the OLCT 710 as an option) Power 11.5-28 VDC RS-485 Modbus serial output 4-20 ma output 3/4" NPT Thread Fully Encapsulated Circuitry OLCT 700 Eliminates failures due to water ingress, corrosion, and vibration Corrosion Resistant Viewing Lens and Display Scrolling alpha-numeric LED display. Full Text Display Method. Displays reading, status, and supports user interface. Electropolished 316SS sensor housing Internal Magnetic Programming Non-intrusive and simplified operator interface via handheld magnet. Plug-in Replaceable Gas Sensors Plug and play components Minimal spare parts Corrosion-Resistant Lower Housing Electropolished 316 SS threaded housing for quick release. Harsh Environment Splashguard Integral Calibration Port

OLCT 700 & 710 Spécifications Combustible Hydrocarbon & Carbon Dioxide Gas Detectors Gas *Standard Gas / Symbol Gas / Symbol OLCT 700/710 IR Combustible Hydrocarbons or CO 2 0-100 % LEL* or 0-5% vol.* CO 2 2 years on sensor Hydrogen Sulfide Gas Detector (solid state metal oxide semiconductor) OLCT 700/710 TP Hydrogen Sulfide/H 2 S 0-20 ppm, 0-50 ppm, 0-100 ppm*, 0-200 ppm 5 years on sensor Combustible Gas Detector (matched pair catalytic bead) OLCT 700/710 FP Combustible Gas 0-100 % LEL 2 years on sensor Input Voltage Power Consumption Outputs Dimensions Weight Approvals Functional Safety Performance Approvals Accuracy / Repeatability Response / Clearing Time Operating Humidity (Continuous) OLCT 700 OLCT 710 178mm (7") Height x 65mm (2.2") Ø 1.14 kg (2.5 lbs) 11.5-28 VDC standard < 2 watts typical Linear 4-20 ma DC RS - 485 Modbus TM RTU 349mm (13.74") Height x 127 mm (5") Width x 130 mm (5.12") Depth Aluminun 3,36 kg (7.40 lbs) Stainless steel version 7.44 kg (16.40 lbs) ATEX II 2G Ex d IIB+H2 T4 Gb SIL2 as per IEC 61508 (except CO2) OLCT 700 IR, OLCT 700 FP to ISA 12.13, CSA #152 OLCT 700 TP, ISA 92.0.01 OLCT 700/710 FP and IR: ±3% LEL 0-50% LEL; ±5% LEL 50-100% LEL OLCT 700 TP: ±10% of reading or ±2 ppm (greater of) OLCT 700 IR-CO2: ±5% full scale OLCT 700/710 FP and IR-CH: T50 <10 s; T90 <30s (respectively 6s and 10s as tested with 1 LPM flow rate) OLCT 700 TP: T50 <30 s; T80 <60 s OLCT 700 IR-CO2: T50 <15 s; T90 <40 s OLCT 700 FP: 0-99% RH non-condensing OLCT 700 TP: 15-100% RH non-condensing OLCT 700 IR: 0-99% RH non-condensing contact factory for specific gases As an ISO 9001 & ISO 14001 approved company, OLDHAM quality assurance programmes demand the continuous assessment and improvement of all OLDHAM products. Information in this leaflet could thus change without notification and does not constitute a product specification. Please contact OLDHAM or their representative if you require more details.

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.