MHCFC4W Chilled/Hot Water Cassette Fan Coil

Similar documents
MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

CWA4 Chilled & Hot Water Fan Coil

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

FCC Fan-Coil Units High-Performance, Vertical

Product Specifications. Vertical Floor Consoles By First Co.

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Commercial High-Efficiency Condensing Units

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

catalog CDV Fan-Coil Units High-Performance, Vertical

Q-TEC QC-Series Chilled Water Air Conditioner

PAJ3. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

MERIT Series R-410A - Upflow / Horizontal

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

Q-Tec TM QC-Series Chilled Water Air Conditioner

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

SKYPAK II Heating & Cooling Self Contained Packages

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Wall Mounted Air Conditioners with Gas Heat Models AVGA

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SpaceKeeper Console (SKC)

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

SeasonMaker ThinLine Fan-coil Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

Concealed Ducted Split Series R-407C MBH

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Specifications and Performance S2H

SeasonMaker ThinLine Fan-coil Units

MERIT SERIES Up Flow / Horizontal

GUIDE SPECIFICATIONS AQUARIUS ii

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

VERTICAL FAN COIL UNITS

Incremental Comfort Conditioners

Bosch BVA Series Air Handler

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

C13-Series Engineering Guide

13 GEP A L P - 1 A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

Submittal Data Performance Data Electrical Data

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

General Description. Operation

16 SEER TWO-STAGE AIR CONDITIONERS

WJH4 Product Specifications

AIR HANDLERS AIR HANDLERS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL SPECIFICATIONS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

RGE 13 A T - 1 A

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

technical guide Water-Cooled Self-Contained Units

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

13 SEER CONDENSING UNITS

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

SSL & SBS Engineering Guide

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Call us today! (800)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Transcription:

MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1

HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua Model Number: MHCFC4W-08-1 Part 1 - General 1.01 System Description: Multiaqua Chilled Water Fan Coils are manufactured with galvanized steel and high impact molded polymers. 1.02 Quality Assurance: A. ETL Certified in accordance with U.L. Standard 95, latest version (U.S.A.). B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully load tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling: A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. Part 2 - Product 2.01 Equipment: A. General: 1. Unit shall be a factory assembled and tested water fan coil. 2. Unit shall be assembled with high quality. 3. Contained within the unit shall be all factory wiring, piping, and associated controls. B. Unit Cabinet and Cover: 1. Cabinet is constructed of galvanized sheet metal. 2. Cover composed of high impact polymers. 3. Internally and externally insulated to ensure quiet operation. C. Fan Motor and Blower Wheels: 1. Available in 208/230-1-50/60 VAC. 2. Fan motor shall be three speed, direct drive, and PSC type. 3. Fan motor shall be totally enclosed. 4. Fan motor shall be internal overload protected. 5. Radial blower wheel is dynamically balanced. D. Air Distribution: 1. Unit contains four manually adjustable discharge air louvers. E. Water Coil: 1. Manufactured with water coils containing copper tubing mechanically bonded to aluminum fins. 2. Coils are factory tested to 300 psig. 3. Coils are designed to accept an entering water temperature not to exceed 160 F 4. Pressure independent flow control required on both coils to not exceed max flow for each coil. Consult primary coil and secondary coil data for proper sizing F. Drain Pan: 1. Constructed of injected molded polystyrene. Rev. 1.1

G. Filters: 1. Unit shall contain a woven panel washable filter. H. Fresh Air: 1. Unit shall be able to receive up to 50% filtered fresh air. 2. Fresh air introduced shall be externally fan forced and externally controlled. Part 3 - Controls and Safeties 3.01 Controls: A. Fan coils are factory wired and tested. B. Unit includes a terminal block that is capable of incorporating a 24 vac, field supplied, hard wired thermostat. 3.02 Safeties: A. Fan coil contains a renewable fuse on the low voltage side of the transformer. B. Coils shall be designed to accept an entering water temperature not to exceed 160 F Part 4 - Operating Characteristics 4.01 Electrical Requirements A. Electrical line voltage connections shall be made at the factory supplied terminal block. B. Factory wiring shall be rated according to UL listing at the time of manufacturing. 4.02 Installation in high ambient/high humidity environments A. Cabinets are internally insulated from the factory. However, when these units are installed in high ambient/high humidity environments, additional external cabinet insulation may be required. Part 5- Definitions 5.01 Abbreviations: = Cubic Feet per Minute DB = Dry Bulb Temperature EWT = Entering Water Temperature = US Gallons Per Minute MBH = BTU X 1000 SC = Sensible Cooling TC = Total Cooling = Sensible + Latent WB = Wet Bulb Temperature = Water Pressure Drop in feet of head db = Decibel Level m = Meter In = Inches FP I= Fins per Inch OD = Outside Diameter ID = Inside Diameter MCA = Minimum Circuit Amps MOP = Maximum Over current Protection LBS = Pounds U.S. 5.02 Measurements A. All measurements with regard to length, width, and height shall be in inches. Rev. 1.1

MHCFC4W-08-01 Product Specifications Physical Data Model Number Overall Height (in) Overall Width* (in) Width** (in) Weight (lbs.) Cooling Rows FPI Heating Rows FPI Water Inlet/Outlet (in) Drain (in) MHCFC4W-08-1 16.8 32.7 28.0 71.7 3/14 1/14 ¾ FPT 1 barb * Units are Square. Overall width is the cover dimension. See IOM for drawing details. * Units are Square. Width is the cabinet dimension. See IOM for drawing details. Model Number Electrical Data*** Volts/ Phase/ Hertz Motor Watts Full Load Amps Fuse or HACR Circuit Breaker or Glass Fuse Per Circuit MCA MOP MHCFC4W-08-1 550 208/230-1- 50/60 130.65 1 1 * All Electric Data Shown is at 60 hz Rev. 1.1

MHCFC4W-08-01 Chilled Water Performance Data MHCFC4W-08-01 COOLING CAPACITIES (Primary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 15950 3.0 SC 14397 4.3 TC 23240 4.5 SC 15975 550* 42 9.1 TC 26178 6.5 SC 17232 17.9 TC 27036 7.5 SC 17607 23.3 *High Speed MHCFC4W-08-01 COOLING CAPACITIES (Primary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 17629 3.0 SC 13590 4.3 TC 20836 4.5 SC 14966 550* 45 9.0 TC 23310 6.5 SC 16012 17.8 TC 24086 7.5 SC 16341 23.1 *High Speed Recommended minimum flow rate for the primary coil at > 2 fps is 2.75 gpm Recommended maximum flow rate for the primary coil at < 6 fps is 7.75 gpm Check www.multiaqua.com for the latest information. 5

MHCFC4W-08-01 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered 50 550 (Primary Coil) WATER TEMPERATURE ( F) 3.0 4.0 17968 22492 27031 31581 36141 40709 45281 49856 4.5 8.3 19231 24067 28916 33776 38643 43516 48394 53275 6.5 16.3 20035 25065 30106 35155 40211 45271 50335 55401 7.5 21.3 20280 25369 30468 35574 40685 45801 50921 56042 60 550 (Primary Coil) WATER TEMPERATURE ( F) 3.0 4.0 13514 18027 22557 27099 31652 36213 40780 45350 4.5 8.3 14451 19278 24119 28971 33832 38699 43572 48448 6.5 16.3 15047 20071 25105 30148 35198 40254 45313 50376 7.5 21.2 15229 20312 25404 30505 35612 40724 45839 50958 70 550 (Primary Coil) WATER TEMPERATURE ( F) 3.0 3.9 9053 13557 18078 22613 27159 31714 36276 40842 4.5 8.3 9667 14486 19319 24164 29019 33881 38749 43622 6.5 16.3 10058 15074 20102 25140 30185 35236 40292 45352 7.5 21.2 10178 15254 20340 25436 30538 35646 40759 45874 80 550 (Primary Coil) WATER TEMPERATURE ( F) 3.0 3.9 4585 9080 13593 18121 22661 27210 31767 36328 4.5 8.3 4879 9689 14515 19353 24202 29059 33923 38791 6.5 16.2 5067 10075 15097 20129 25169 30216 35268 40324 7.5 21.1 5124 10193 15274 20364 25462 30566 35675 40787 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: MHCFC4W-08-01 HOT WATER CAPACITY (Primary coil) AIR TEMPERATURE WATER TEMPERATURE 140F 3.0 31985 70F DB / 60F WB 4.5 34208 6.5 35601 7.5 36023 Check www.multiaqua.com for the latest information. 6

MHCFC4W-08-01 Chilled Water Performance Data MHCFC4W-08-01 COOLING CAPACITIES (Secondary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 8683 2.5 SC 7172 1.5 TC 9726 3.0 SC 7569 550* 42 2.0 TC 11242 4.0 SC 8176 3.5 TC 12333 5.0 SC 8616 5.4 *High Speed MHCFC4W-08-01 COOLING CAPACITIES (Secondary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 7675 2.5 SC 6826 1.5 TC 8575 3.0 SC 7178 550* 45 2.0 TC 9973 4.0 SC 7713 3.5 TC 10946 5.0 SC 8099 5.3 *High Speed Recommended minimum flow rate for the secondary coil at > 2 fps is 2.75 gpm Recommended maximum flow rate for the secondary coil at < 6 fps is 7.75 gpm Check www.multiaqua.com for the latest information. 7

MHCFC4W-08-01 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered 50 550 (Secondary Coil) WATER TEMPERATURE ( F) 2.5 1.4 10027 12552 15099 17666 20249 22845 25452 28067 3.0 1.9 10389 13000 15634 18285 20950 23628 26316 29011 4.0 3.3 10888 13618 16367 19131 21908 24696 27491 30294 5.0 5.0 11218 14025 16848 19686 22534 25392 28257 31128 60 550 (Secondary Coil) WATER TEMPERATURE ( F) 2.5 1.4 7595 10104 12638 15193 17764 20350 29947 35936 3.0 1.9 7863 10460 13080 15719 18374 21043 23721 26409 4.0 3.3 8233 10949 13686 16440 19208 21987 24775 27570 5.0 5.0 8477 11272 14085 16913 19753 22603 25461 28326 70 550 (Secondary Coil) WATER TEMPERATURE ( F) 2.5 1.4 5156 7651 10172 12715 15276 17851 20440 23039 3.0 1.9 5332 7915 10523 13150 15795 18454 21124 23804 4.0 3.3 5574 8278 11003 13747 16505 19276 22056 24845 5.0 5.0 5734 8517 11320 14138 16970 19812 22664 25522 80 550 (Secondary Coil) WATER TEMPERATURE ( F) 2.5 1.4 2712 5193 7701 10232 12782 15349 17928 20519 3.0 1.9 2795 5365 7961 10577 13212 15862 18524 21197 4.0 3.3 2911 5603 8317 11051 13800 16562 19336 22118 5.0 5.0 2988 5760 8552 11361 14185 17020 19865 22717 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: MHCFC4W-08-01 HOT WATER CAPACITY (Secondary Coil) AIR TEMPERATURE WATER TEMPERATURE 140F 2.5 17921 70F DB / 60F WB 3.0 18529 4.0 19358 5.0 19900 Check www.multiaqua.com for the latest information. 8

MHCFC4W-08-01 Chilled Water Performance Data MHCFC4W-08-01 COOLING CAPACITIES (Both Coils) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 25459 5.5 SC 17016 3.3 TC 27112 6.5 SC 17719 550* 42 4.6 TC 28421 7.5 SC 18309 6.0 TC 29498 8.5 SC 18781 7.6 *High Speed MHCFC4W-08-01 COOLING CAPACITIES (Both Coils) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 22886 5.5 SC 16366 3.3 TC 24353 6.5 SC 16999 550* 45 4.6 TC 25505 7.5 SC 17035 6.0 TC 26459 8.5 SC 17437 7.2 *High Speed Pressure independent flow control required on both coils to not exceed max flow for each coil Consult primary coil and secondary coil data for proper sizing Recommended minimum flow rate for both coils piped in parallel at > 2fps is 5.5 gpm Recommended minimum flow rate for both coils piped in parallel at < 6fps is 15.5 gpm Check www.multiaqua.com for the latest information. 9

MHCFC4W-08-01 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered 50 550 (Both Coils) WATER TEMPERATURE ( F) 5.5 3.1 20892 26157 31436 36726 42026 47332 52644 57959 6.5 4.3 21252 26602 31964 37336 42717 48103 53494 58889 7.5 5.6 21513 26924 32346 37777 43215 48659 54106 59557 8.5 7.1 21710 27167 32634 38109 43590 49076 54566 60058 60 550 (Both Coils) WATER TEMPERATURE ( F) 5.5 3.1 15689 20943 26213 31495 36788 42088 47394 52704 6.5 4.3 15956 21296 26651 32016 37390 42770 48156 53546 7.5 5.6 16149 21552 26967 32391 37924 43262 48705 54152 8.5 7.0 16296 21745 27205 32674 38150 43632 49118 54607 70 550 (Both Coils) WATER TEMPERATURE ( F) 5.5 3.1 10482 15727 20988 26263 31548 36842 42143 47449 6.5 4.3 10657 15989 21335 26694 32062 37437 42819 48205 7.5 5.6 10784 16179 21587 27005 32432 37866 43305 48748 8.5 7.0 10880 16322 21776 27240 32711 38188 43670 49156 80 550 (Both Coils) WATER TEMPERATURE ( F) 5.5 3.1 5271 10506 15759 21026 26305 31593 36888 42190 6.5 4.2 5355 10678 16017 21368 26730 32100 37477 42859 7.5 5.6 5415 10802 16203 21616 27037 32466 37901 43340 8.5 7.0 5461 10896 16344 21802 27268 32741 38219 43701 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: MHCFC4W-08-01 HOT WATER CAPACITY (Both coils) AIR TEMPERATURE WATER TEMPERATURE 140F 5.5 37258 70F DB / 60F WB 6.5 37874 7.5 38318 8.5 38653

MHCFC4W-08-01 Data MODEL # Fan Speed MHCFC4W-08-01 L 400 M 475 H 550 Wattage @ High Speed 130

MHCFC4W-08-01 Sound Data MODEL # MHCFC4W-08-01 Fan Speed db @ 1 m H 46 M 43 L 39

MHCFC4W-08-01 Wiring Diagram

See Installation and Operation Manual for Dimensional Drawings