IMPORTANT. Cleaning the birth pool

Similar documents
User manual. Fjordblink Birth Pool and Water Supply Unit.

TECHNOSKLO Ltd. Držkov

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

CPAP Washbasin Manual

Closing procedures for above-ground pools

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Standard operating procedures for the TEAL Stop n Wash TSNW230

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Closing procedures for in-ground pools

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

1 of 7 12/22/2017, 3:28 PM. Composition

MIT Emergency Response Guide

RFP# FS REGION 8 TIPS FOOD PURCHASING CO-OP SANITATION AND CLEANING SUPPLIES FOR FOOD SERVICE AREA ONLY. Drop Ship 1 location 50 CT

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Easy Guide Luna 1300 Luna 1400 PARTS CHECKLIST - LUNA 1300 AND LUNA ONLY. Telescopic extension tube. Carpet washer. Hose and hand grip

All products are colour coded for easy identification

bypass TUB ENCLOSUREs

DualPower PET ADVANCE

Dual Power Let s get started

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Workbook Clean floors

Ropox Swing Wash Basin. User Manual & Mounting Instructions / Fixed height with high wall unit. Keep this folder with product at all times!

Step-by-Step Guide To Clean Your Own Pool

Ropox Swing Wash Basin. User Manual & Mounting Instructions / Height adjustable with high wall unit

I N S T R U C T I O N S

Installation & Operating Instructions

Team grup. Risk management during the production of mineral water. Presentation at the 3 rd SAFOODNET seminar. Urban Wiik.

- 2 - IMPORTANT SAFETY REMINDERS IT IS IMPORTANT THAT YOU:

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final 120v 60Hz. Copyright 2017 Page of 20

CHILDCARE SETTINGS. Childcare Settings

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

AUBREY with MAJOLICA PORTO Operation / Installation manual

R 7420 HANDLING AND DISPOSAL OF BODY WASTES AND FLUIDS

REFRIGERAT A OR USE DF1-15 F ridge

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

Well Disinfection. Safety Concerns. Electrical. Chemical

Quality makes the Difference. AquaTREND uni. User s Manual Humidifi er for Therapeutic Air Flow

Midi Dehumidifi er IMPORTANT! KEEP FOR FUTURE REFERENCE. Instruction Manual. Please register your product on-line at

1 Intended Use of the Breas HA 01 Humidifier

Owners Manual For The Rainmaster Water Recycling System

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

INSTALLATION & OPERATION MANUAL

INSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE

Electric steam steriliser

Disposable Medical Pulp Containers

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

optimal safety and security at the workplace International Organization for Standardization H A ISO BUFEAU VERITAS Certification

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

SELF-CONTAINED CRESCENT CUBER

Dual Power Let s get started

Introduction. Table of Contents

ROX-10WB-E WATER ELECTROLYZER INSTRUCTION MANUAL FOR END USER L188AU111 (100507)

Hoshizaki America, Inc.

FOOD AREA SOLUTIONS Cleaning Spray & Wipe Disinfectant Skin Care Vegetable Cleaning Beerline Cleaning Sanitisers

S-pod / ALTOR BATHROOMS MAINTENANCE NOTICE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

O-PEP Hygiene-Beileger

VENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products

triple7 Municipal Environmental Solutions

Full Facility Norovirus Cleaning Reference Document for Food Establishments

Installation Guide. Inline Chlorinator TM. Vitasalus, Inc Rankin Drive Troy, Michigan USA

CLEANING AND SANITATION Policy Owner: Erica Tennessen Policy Originated by (program or department): Program Applicable Programs: All Programs

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

Serpentine water heater. Instruction manual

Closing procedures for in-ground pools

DualPower MAX DOUBLE UP AND DEEP CLEAN LET S GET STARTED. VRS801

Parts Washer & Distiller. Leading Cleaning Technology

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

ConserveWell. Thank You MODEL: CW MODEL: CW-T 87750

Best Practices. Foam Cleaning Fogging Spraying. Principles of Cleaning

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Section 1. Information before installation

Operating Instructions

PIHA DUTIES HANDBOOK. 64 Glenesk Road, Piha

THE NEXT GENERATION CARBOY

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Designed in the UK. Rapide. User Guide V-024E. Performance is everything. vax.co.uk

The PURO GRAND Condensate Cleaner Installation instructions: Maintenance instructions:

Ozone & UV & AOP Solutions ADVANCED TECHNOLOGIES

Pro6 Duo. Stampa Novaprint - Tel cod USER MANUAL


METASYS. Amalgam separator ECONOMY SYSTEM TYPE 2 ECO II. Installation, operation and maintenance

the Compact Kettle Instruction Book - BKE320BSS

VAPORETTINO LUX A B C E. Fig.1 Fig.2 Fig.3 Fig.4. Fig.5 Fig.6 Fig.7 Fig.8. Fig.9 Fig.10 Fig.11. Vaporettino Lux 1R02

EPISD RISK MANAGEMENT. Custodial Safety

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

Cavitator Ultrasonic Cleaners

Robotic Pool Cleaner REVOLUTION I. Operating Instructions Robotic Pool Cleaner REVOLUTION I... p. 1-8

Get Cleaning... What s your Vax s model number? User Guide. Multifunction SpinScrub. vax.com.au. Vax Careline: AU: NZ:

EN Variable Temperature Electric Kettle

Transcription:

Cleaning the birth pool This manual conforms to the guidelines issued by Statens Serum Institut (SSI) under the Danish Ministry of Health, for cleaning of heated water pools for obstetric use. The manual includes tips for reducing chlorine odour. After use, raise the birth pool to a suitable 1 working height using the Up/Down buttons on the supply unit's control panel. 1 Open the pool's drainage system by pressing 2 the Water Outlet button 1 on the supply unit. When the light in the button is OFF, the drainage system valve is open and water can drain out of the pool. Rinse the pool thoroughly using the hand 3 shower head 2 on the supply unit. 2 IMPORTANT The temperature of the cleaning water must not exceed 55-60 C. 4 Remove and clean the pool's drain plug. It can be cleaned in an instrument washer or autoclaved. 16

Clean the drain using a cleaning brush and 5 then rinse with clean running water using the hand shower head. Clean the pool using a soft cloth and a 6 neutral cleaning agent. Next, rinse the pool thoroughly. The pool is 7 now clean and ready to be disinfected. IMPORTANT Never use a scouring agent or strongly alkaline cleaning agent. Never use razor blades or other sharp objects for cleaning. 17

Disinfection of drain pipe and pool interior using Actichlor Plus! CAUTION Always read the material safety data sheet (MSDS) and the accompanying instructions for the cleaning or disinfecting agent, and observe the instructions for safe use, dissolving, rinsing, drying, handling and storage of the agent. 1 Place 1 Actichlor Plus tablet in 1 litre of 1 clean, tepid water (1,000 PPM). Leave the tablet to dissolve in the water (takes approx. 5 minutes). You may wish to make up the solution in a capped disposable bottle to reduce the chlorine odour. NOTE: do not mix Actichlor Plus with other cleaning agents. Close the pool's drainage system. Press the 2 Water Outlet button 1 on the supply unit and wait until the button lights up. When you see the light, the drainage system valve is closed. Pour the Actichlor solution into the drain 3 until the drain pipe is visibly full. Fill a plastic bag with water and place it over the drain hole so as to seal it and prevent chlorine odour escaping. The Actichlor solution must be left to work in the drain for 30 minutes to eliminate C. difficile bacteria. See also the instructions on the Actichlor packaging. Raise the pool to the correct working 4 height, disperse the Actichlor solution using a soft cloth over all the internal surfaces of the pool and leave the liquid to dry. Remove the bag at the bottom of the pool 5 and open the pool's drain by pressing the button 1. Use the hand shower head to rinse the pool thoroughly. Let the water drain out through the pool's drainage system and through the outlet hose and supply unit. 18

Full cleaning of the drainage system We recommend cleaning the entire drainage system every 4 weeks.! CAUTION Always read the material safety data sheet (MSDS) and the accompanying instructions for the cleaning or disinfecting agent, and observe the instructions for safe use, dissolving, rinsing, drying, handling and storage of the agent. 1 Place 1 Actichlor Plus tablet in 1 litre of 1 clean, tepid water (1,000 PPM). Leave the tablet to dissolve in the water (takes approx. 5 minutes). You may wish to make up the solution in a capped disposable bottle to reduce the chlorine odour. NOTE: do not mix Actichlor Plus with other cleaning agents. Check that the pool's drainage system is 2 open. Press the Water Outlet button 1 on the supply unit. If the button is NOT lit, this indicates that the drain pipe is open and the water can drain out. Disconnect the pool's outlet hose. The hose 3 disconnects easily by hand. The outlet hose must be cleaned in an instrument washer (for information on the hose, see below). If the pool was last used with a disposable hose, dispose of this used hose and connect a fresh one. Screw the drain plug onto the pool's drain 4 pipe. 5 Pour Actichlor solution into the drain pipe until the drain is visibly full. Fill a plastic bag with water and place it over the drain hole so as to seal it and prevent chlorine odour escaping. The Actichlor solution must be left to work in the drain for 30 minutes to eliminate C. difficile bacteria. See also the instructions on the Actichlor packaging. 19

Place a basin under the plugged drain pipe. 6 The basin volume must be at least 1 litre. Place the basin in a bag so as to be able to seal the bag around the basin when you come to remove it. This prevents spills and reduces chlorine odour when removing the basin. Now remove the drain plug and let the 7 water drain into the basin (approx. 600 ml). Draw the bag up around the basin and knot the bag. Remove the basin. Reconnect the outlet hose between the pool 8 and the supply unit. Remove the water-filled bag from the pool. 9 10 Use the hand shower head to rinse the pool's drain thoroughly. Let the water drain out through the pool's drain pipe and through the outlet hose and supply unit. 20

Easy-clean outlet hose specifications Vulcano PU-H 09 Etere (Polyurethane) Working pressure: 10 BAR/+90 C Microorganism and hydrolysis resistant Cleaning: -40 C to +90 C can also withstand +125 C for a short period of time (max. 25 minutes) FDA-approved FDA-21 CFR 177.2600 Certified in conformity with EU 10/2011/EC The outlet reducer is made of stainless steel The disconnected outlet hose may be cleaned in an instrument washer. Fjordblink Medical ApS Vibelandsvej 8 DK-3200 Helsinge Denmark Tel.: +45 40 74 05 23 E-mail: post@fjordblink.com Version 1.1 10/2015 FJORDBLINK Medical Birth Pool Designed by midwives for midwives