Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch REFRIGERATIVE SUPPLY #04 (18852) 2885 Quesnel Street VICTORIA, BC V8T 4K2
Project Name : Fuller Lake Arena VRF Management Number : Building : Created by : Steve Chamut Company : Refrigerative Supply Address : stevec@rsl.ca 1.Material list 1.1.Material list Series:VRF system Model Quantity Type AOUA168TLBVG 1 VR-II Heat Recovery ASUA9TLAV 5 Wall mounted ASUA12TLAV 3 Wall mounted ASUB18TLAV 2 Wall mounted ASUB24TLAV 2 Wall mounted UTY-DTGYZ1 1 Touch panel controller(internet access) UTY-RNRUZ1 12 Wired RC(Touch) Z1 UTP-BX180A 2 Separation tube UTP-DX567A 1 Outdoor unit branch kit UTP-RU04BH 3 RB unit 1.2.Material List 2 (Pipe) Series:VRF system Pipe length(ft) 1/4 3/8 1/2 5/8 3/4 7/8 1-1/8 Total 423 149 477 199 42 57 75 1.3.Material List 3 (Calculation of additional charge refrigerant) Series:VRF system Refrigerant lbs R410A 33.8
2.Indoor unit details 2.1.Table of abbreviations Name Local name of the device HC Available heating capacity (with defrost compensation) Model Device model name Airflow Supplied airflow at low and high fan speed RC C Rated cooling capacity ESP External static pressure RC H Rated heating capacity Sound Sound pressure low and high Tmp C Indoor condition in cooling MCA Minimum Circuit Amps Rq TC Required cooling capacity HxWxD Height x Width x Depth TC Available total cooling capacity Weight Weight of the device Rq SC Required sensible cooling capacity Dis Tmp C Discharge temperature at cooling SC Available sensible cooling capacity Dis Tmp H Discharge temperature at heating Tmp H Indoor temperature in heating HE Heat exchanger volume Rq HC Required heating capacity (with defrost compensation) Rated Rated current 2.2.Otdr1 (VRF system) - AOUA168TLBVG Name Model RC C (Ton) RC H (Ton) Tmp C (F/%) Rq TC (Ton) TC (Ton) Rq SC (Ton) SC (Ton) Tmp H (F) Rq HC (Ton) HC (Ton) EU-1 ASUB18TLAV 1.50 1.67 80.0/47.9 0.28 1.41 0.28 1.02 70.0 0.28 1.57 EU-2 ASUB18TLAV 1.50 1.67 80.0/47.9 0.28 1.41 0.28 1.02 70.0 0.28 1.57 EU-3 ASUA12TLAV 1.00 1.13 80.0/47.9 0.28 0.94 0.28 0.66 70.0 0.28 1.06 EU-4 ASUA9TLAV 0.79 0.91 80.0/47.9 0.28 0.74 0.28 0.55 70.0 0.28 0.86 EU-5 ASUA9TLAV 0.79 0.91 80.0/47.9 0.28 0.74 0.28 0.55 70.0 0.28 0.86 EU-6 ASUB24TLAV 2.00 2.25 80.0/47.9 0.28 1.88 0.28 1.34 70.0 0.28 2.12 EU-7 ASUB24TLAV 2.00 2.25 80.0/47.9 0.28 1.88 0.28 1.34 70.0 0.28 2.12 EU-8 ASUA9TLAV 0.79 0.91 80.0/47.9 0.28 0.74 0.28 0.55 70.0 0.28 0.86 EU-9 ASUA9TLAV 0.79 0.91 80.0/47.9 0.28 0.74 0.28 0.55 70.0 0.28 0.86 EU-10 ASUA9TLAV 0.79 0.91 80.0/47.9 0.28 0.74 0.28 0.55 70.0 0.28 0.86 EU-11 ASUA12TLAV 1.00 1.13 80.0/47.9 0.28 0.94 0.28 0.66 70.0 0.28 1.06 EU-12 ASUA12TLAV 1.00 1.13 80.0/47.9 0.28 0.94 0.28 0.66 70.0 0.28 1.06 Name Model Airflow (cfm) EU-1 ASUB18TLAV High 494.0 EU-2 ASUB18TLAV High 494.0 EU-3 ASUA12TLAV High 330.0 EU-4 ASUA9TLAV High 294.0 EU-5 ASUA9TLAV High 294.0 EU-6 ASUB24TLAV High 647.0 EU-7 ASUB24TLAV High 647.0 EU-8 ASUA9TLAV High 294.0 EU-9 ASUA9TLAV High 294.0 ESP (WG) Sound (db) Rated (A) MCA (A) HxWxD (inch) 41 0.33 0.53 12-5/8 x 39-5/16 x 9 41 0.33 0.53 12-5/8 x 39-5/16 x 9 39 0.20 0.51 10-13/16 x 31-1/8 x 8-7/16 36 0.18 0.51 10-13/16 x 31-1/8 x 8-7/16 36 0.18 0.51 10-13/16 x 31-1/8 x 8-7/16 48 0.52 0.65 12-5/8 x 39-5/16 x 9 48 0.52 0.65 12-5/8 x 39-5/16 x 9 36 0.18 0.51 10-13/16 x 31-1/8 x 8-7/16 36 0.18 0.51 10-13/16 x 31-1/8 x 8-7/16 Weight (lbs) 33.0 33.0 20.0 20.0 20.0 33.0 33.0 20.0 20.0 Image
EU-10 ASUA9TLAV High 294.0 EU-11 ASUA12TLAV High 330.0 EU-12 ASUA12TLAV High 330.0 36 0.18 0.51 10-13/16 x 31-1/8 x 8-7/16 39 0.20 0.51 10-13/16 x 31-1/8 x 8-7/16 39 0.20 0.51 10-13/16 x 31-1/8 x 8-7/16 20.0 20.0 20.0
3.Outdoor unit details 3.1.Table of abbreviations Name Local name of the device Tmp H Outdoor temperature in heating(dry bulb) Model Device model name HC Heating capacity EER Energy efficiency rating MCA Minimum Circuit Amps COP Coefficient of Performance MFA Main fuse (circuit breaker) current RC C Rated cooling capacity HxWxD Height x Width x Depth RC H Rated heating capacity Weight Weight of the device Comb Combination percentage Refrig Standard factory refrigerant charge Tmp C Outdoor temperature in cooling(dry bulb) Rated C Rated current Cooling TC Available total cooling capacity Rated H Rated current Heating 3.2.Outdoor unit details Series:VRF system Name Model EER COP Comb (%) RC C (Ton) RC H (Ton) Tmp C (F) TC (Ton) Tmp H (F) HC (Ton) Otdr1 AOUA168TLBVG 11 3.48 99.7 14.00 15.75 95.0 13.13 47.0 14.86 AOUA96TLBV AOUA72TLBV Name Model PS Rated C (A) Otdr1 AOUA168TLBVG 3Phase, 208V, 60Hz Rated H (A) MCA MFA HxWxD Weight Refrig (A) (A) (inch) (lbs) (lbs) 82 1194.0 52.0 Image AOUA96TLBV AOUA72TLBV 3Phase, 208V, 60Hz 3Phase, 208V, 60Hz 20.12 20.79 50 66-9/16x36-5/8x30-1/8 14.31 14.57 50 66-9/16x36-5/8x30-1/8 597.0 26.0 597.0 26.0
4.Piping Diagrams 4.1.Piping Otdr1 (VRF system) Refrig R410A(lbs) 52.0 Add Refrig R410A(lbs) 33.8 Total Refrig R410A(lbs) 85.8
5.Wiring Diagrams 5.1.Wiring Otdr1 (VRF system) Airstage Project - 9217
5.2.Wiring Otdr1 (VRF system) Airstage Project - 9217
6.Options Otdr1 (VRF system) - AOUA168TLBVG Name Model Type Qty Model Type Qty EU-1 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-2 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-3 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-4 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-5 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-6 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-7 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-8 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-9 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-10 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-11 UTY-RNRUZ1 Wired RC(Touch) Z1 1 EU-12 UTY-RNRUZ1 Wired RC(Touch) Z1 1
7.Piping / Branch kit / Header details 7.1.Branch kit details Series:VRF system Name Model UTP-BX180A UTP-DX567A Otdr1 AOUA168TLBVG 2 1 7.2.Header details 7.3.Piping details Series:VRF system Name Model 1/4 3/8 1/2 5/8 3/4 7/8 1-1/8 Otdr1 AOUA168TLBVG 423 149 477 199 42 57.0 75 Name Refrig R410A(lbs) Add Refrig R410A(lbs) Total Refrig R410A(lbs) Otdr1 52.0 33.8 85.8 7.4.Branch box details 7.5.RB details Series:VRF system Name Model UTP-RU01AH UTP-RU01BH UTP-RU01CH UTP-RU04BH Otdr1 AOUA168TLBVG 0 0 0 3 7.6.DX Kit details
8.User option 8.1.8.User options(project) 8.2.8.User options(refrigerant) Airstage Project - 9217
9.Room list 9.1.Room list 9.2.Room-indoor list There are some differences between a calculated result and specification. Airstage Project - 9217
Job Name Location Engineer Submitted To Submitted By Reference Submittal AOUA72TLBV 6 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) 1X (AOUA72TLBV) Date Approval Construction Unit No Drawing No Inverter driven compressor New style high power DC fan motor. Blue fin heat-exchanger (Corrosion resistance) 10 Year warranty on parts and compressor. See Warranty Statement for details. Optional: Internet, BACnet, LonWorks, or Modbus communication. CAPACITY OPERATING TEMPERATURES Nominal Cooling Capacity - BTU/h [kw] 72,000 [21.1] Operating Temp. Cooling (DB) - F [ C] 14 to 115 [-10 to 46] Nominal Heating Capacity - BTU/h [kw] 81,000 [23.7] Operating Temp. Heating (DB) - F [ C] -4 to 70 [-20 to 21] Nominal Tonage - Ton(s) 6 Operating Temp. Cooling/Heating Simultaneous - F [ C] 14 to 70 [-10 to 21] Maximum Connectable Indoor Units 14 Connectable Capacity 50% to 150% EFFICIENCY Cooling Power Input - kw 5.31 EER Cooling (Ducted/Non Ducted) 12.3 / 12.5 Heating Power Input - kw 5.35 IEER Cooling (Ducted/Non Ducted) 20 / 24.1 Unit Group 1X (AOUA72TLBV) COP / High Heating 47 F 3.64 / 4.06 SCHE (Ducted/Non Ducted) 30.10/24.00 ELECTRICAL Voltage Range 187 to 253 VAC WIRING Maximum Circuit Breaker - A 50 Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Minimum Circuit Ampacity (MCA) - A 41 Cooling Power Input - kw 5.31 Heating Power Input - kw 5.35 PIPING Maximum Starting Current (MSC) - A 33.2 Max. Total Refrigerant Line Length - ft [m] 3,280 [1,000] Compressor - Rated Load Amperage (RLA) - A 17 PipeConnection:Max Height Diff. (ODU & ID)(Upper/Lower) - ft [m] 164/131 [50/40] Fan Motor - Full Load Amperage (FLA) - A 3.0 Pipe Connection Method: Liquid/Gas Brazed Pipe Connection: Liquid - in [mm] 1/2 [12.70] COMPRESSOR Pipe Connection: Discharge Gas - in [mm] 5/8 [15.88] Compressor Type Rotary Inverter Pipe Connection: Suction Gas - in [mm] 7/8 [22.22] Refrigerant Type R410A Refrigerant Charge - lbs [kg] 26.01 [11.80] SOUND Compressor Crankcase Heater - W 2X 35 Sound Pressure Levels (Cooling/Heating) - db(a) 57 / 58 Refrigerant Oil / Lubricant POE Compressor Capacity Control - Steps/Range 951 / 20-115 WEIGHT Net Weight - lbs [kg] 597 [271] FAN Gross Weight - lbs [kg] 642 [291] Fan Type Propeller fan Fan Airflow Rate - CFM [m3/h] 6,533 [11,100] DIMENSIONS Fan Power Output - W 740 Dim.Net (HxWxD) - in [mm] Fan Motor - Full Load Amperage (FLA) - A 3.0 External Static Pressure (Max) - in.wg [Pa] 0.32 [80] HEAT EXCHANGER Dim.Gross (HxWxD) - in [mm] 71-5/16 39-7/16 33-3/8 H. E. Pipe Type (Material) Grooved H-pin (Copper) [1811 1002 847] H. E. Fin Tube (Material) Corrugate (Aluminum) H. E. Fin Surface Treatment Corrosion resistance (Blue fin) H. E. Fin Pitch - FPI [mm] 18 [1.45] CODE H. E. Rows x Stages 3 x 60 ETL 3170288 H. E. Face Area - Ft² [m²] 23 [2.2] AHRI Certified Standard 1230 H. E. Length - in [mm] 69-5/16 [1760] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 66-9/16 x 36-5/8 x 30-1/8 [1690 x 930 x 765] 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal AOUA72TLBV 6 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) DIMENSIONS Unit: In. (mm) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Job Name Location Engineer Submitted To Submitted By Reference Submittal AOUA96TLBV 8 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA96TLBV) 1X (AOUA96TLBV) Date Approval Construction Unit No Drawing No Inverter driven compressor New style high power DC fan motor. Blue fin heat-exchanger (Corrosion resistance) 10 Year warranty on parts and compressor. See Warranty Statement for details. Optional: Internet, BACnet, LonWorks, or Modbus communication. CAPACITY OPERATING TEMPERATURES Nominal Cooling Capacity - BTU/h [kw] 96,000 [28.1] Operating Temp. Cooling (DB) - F [ C] 14 to 115 [-10 to 46] Nominal Heating Capacity - BTU/h [kw] 108,000 [31.7] Operating Temp. Heating (DB) - F [ C] -4 to 70 [-20 to 21] Nominal Tonage - Ton(s) 8 Operating Temp. Cooling/Heating Simultaneous - F [ C] 14 to 70 [-10 to 21] Maximum Connectable Indoor Units 16 Connectable Capacity 50% to 150% EFFICIENCY Cooling Power Input - kw 7.56 EER Cooling (Ducted/Non Ducted) 11.70/11.30 Heating Power Input - kw 7.82 IEER Cooling (Ducted/Non Ducted) 23.60/20.20 Unit Group 1X (AOUA96TLBV) COP / High Heating 47 F 3.72/3.60 SCHE (Ducted/Non Ducted) 26.50/25.50 ELECTRICAL Voltage Range 187 to 253 VAC WIRING Maximum Circuit Breaker - A 50 Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Minimum Circuit Ampacity (MCA) - A 41 Cooling Power Input - kw 7.56 Heating Power Input - kw 7.82 PIPING Maximum Starting Current (MSC) - A 33.2 Max. Total Refrigerant Line Length - ft [m] 3,280 [1,000] Compressor - Rated Load Amperage (RLA) - A 25 PipeConnection:Max Height Diff. (ODU & ID)(Upper/Lower) - ft [m] 164/131 [50/40] Fan Motor - Full Load Amperage (FLA) - A 3.0 Pipe Connection Method: Liquid/Gas Brazed Pipe Connection: Liquid - in [mm] 1/2 [12.70] COMPRESSOR Pipe Connection: Discharge Gas - in [mm] 3/4 [19.05] Compressor Type Rotary Inverter Pipe Connection: Suction Gas - in [mm] 7/8 [22.22] Refrigerant Type R410A Refrigerant Charge - lbs [kg] 26.01 [11.80] SOUND Compressor Crankcase Heater - W 2X 35 Sound Pressure Levels (Cooling/Heating) - db(a) 59/59 Refrigerant Oil / Lubricant POE Compressor Capacity Control - Steps/Range 951 / 20-115 WEIGHT Net Weight - lbs [kg] 597 [271] FAN Gross Weight - lbs [kg] 642 [291] Fan Type Propeller fan Fan Airflow Rate - CFM [m3/h] 6,533 [11,100] DIMENSIONS Fan Power Output - W 740 Dim.Net (HxWxD) - in [mm] Fan Motor - Full Load Amperage (FLA) - A 3.0 External Static Pressure (Max) - in.wg [Pa] 0.32 [80] HEAT EXCHANGER Dim.Gross (HxWxD) - in [mm] 71-5/16 39-7/16 33-3/8 H. E. Pipe Type (Material) Grooved H-pin (Copper) [1811 1002 847] H. E. Fin Tube (Material) Corrugate (Aluminum) H. E. Fin Surface Treatment Corrosion resistance (Blue fin) H. E. Fin Pitch - FPI [mm] 18 [1.45] CODE H. E. Rows x Stages 3 x 60 ETL 3170288 H. E. Face Area - Ft² [m²] 23 [2.2] AHRI Certified Standard 1230 H. E. Length - in [mm] 69-5/16 [1760] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 66-9/16 x 36-5/8 x 30-1/8 [1690 x 930 x 765] 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal AOUA96TLBV 8 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA96TLBV) DIMENSIONS Unit: In. (mm) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUA9TLAV Compact Wall (9,500 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 9,500 [2.8] Capacity - Heating - Btu/h [kw] 10,900 [3.2] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe - 180 MBH or More Input Power - W 18 Full Load Amps - FLA - A 0.41 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.51 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 294 [500] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 265 [450] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] Cololing 247 [420] / Heating 218 [370] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 31-27 (cooling-heating)/33/36 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 1/4 [6.35] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 1/2 [12.70] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 9/16 [14.3] Enclosure - Net Weight - lbs [kg] 20 [9] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 26 [12] Dimensions - Net (H x W x D) - in [mm] 10-13/16 31-1/8 8-7/16 [275 790 215] ETL Dimensions - Gross (H x W x D) - in [mm] 11-7/16 32-7/8 13-9/16 E.T.L. 91986 [290 835 345] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal ASUA9TLAV Compact Wall (9,500 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUA12TLAV Compact Wall (12,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 12,000 [3.5] Capacity - Heating - Btu/h [kw] 13,500 [4] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe - 180 MBH or More Input Power - W 22 Full Load Amps - FLA - A 0.41 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.51 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 330 [560] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 283 [480] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] 247 [420] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 31/35/39 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 1/4 [6.35] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 1/2 [12.70] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 9/16 [14.3] Enclosure - Net Weight - lbs [kg] 20 [9] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 26 [12] Dimensions - Net (H x W x D) - in [mm] 10-13/16 31-1/8 8-7/16 [275 790 215] ETL Dimensions - Gross (H x W x D) - in [mm] 11-7/16 32-7/8 13-9/16 E.T.L. 91986 [290 835 345] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal ASUA12TLAV Compact Wall (12,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUB18TLAV Wall (18,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 18,000 [5.3] Capacity - Heating - Btu/h [kw] 20,000 [5.9] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe - 180 MBH or More Input Power - W 32 Full Load Amps - FLA - A 0.42 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.53 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 494 [840] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 453 [770] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] 406 [690] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 35/39/41 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 3/8 [9.52] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 5/8 [15.88] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 1/2 [12] Enclosure - Net Weight - lbs [kg] 33 [15] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 42 [19] Dimensions - Net (H x W x D) - in [mm] 12-5/8 39-5/16 9 [320 998 228] ETL Dimensions - Gross (H x W x D) - in [mm] 12-9/16 42-15/16 16-7/8 E.T.L. 91986 [319 1,090 429] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal ASUB18TLAV Wall (18,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Job Name Location Engineer Submitted To Submitted By Reference Submittal ASUB24TLAV Wall (24,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System Date Approval Construction Unit No Drawing No FEATURES Powerful output in a compact design Built-in deoderizing and ionizing filters for better air quality Auto swing louvers Very low power usage Built-in IR Receiver 10 Year warranty on parts and compressor. See Warranty Statement for details. STATIC PRESSURE CAPACITY Capacity - Cooling - Btu/h [kw] 24,000 [7.0] Capacity - Heating - Btu/h [kw] 27,000 [7.9] PIPING ACCESSORIES ELECTRICAL UTP-AX090A Separation Tube - 2-Pipe - 90 MBH or Less Power Source 208 / 230V, 1-Phase, 60Hz UTP-AX180A Separation Tube - 2-Pipe - 91 to 180 MBH Available Voltage Range - VAC 187 to 253 UTP-AX567A Separation Tube - 2-Pipe - 180 MBH or More Input Power - W 60 Full Load Amps - FLA - A 0.52 CONTROLLER Max Circuit Breaker - A 15 UTY-RNRU Individual Touch Panel Controller (Wired Remote) Minimum Circuit Ampacity - MCA - A 0.65 UTY-RNKU Wired Remote Control Fuse - A (V) 3.15 (250) UTY-RSKU Simple Remote (WITH Master Control) (1/16 units) UTY-RHKU Simple Remote (WITHOUT Master Control) (1/16 units) FAN UTY-LNHU Wireless Remote Controller (requires IR Receiver) Fan Type Cross flow UTY-DCGY Central Remote Controller (100 units) Airflow Rate - High - CFM [m³/h] 647 [1,100] UTY-DTGYZ1 Touch Panel Controller with Internet (400 units) Airflow Rate - Medium - CFM [m³/h] 536 [910] UTY-APGX System Controller (1600 units) Airflow Rate - Low - CFM [m³/h] 430 [730] UTY-ALGX System Controller Lite - (400 units) SOUND PRESSURE ACCESSORIES Sound Pressure Level - db(a) 35/43/48 UTY-TEKX External Switch Controller UTY-XSZX Remote Sensor for ducted units WIRING Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) PIPING Connection Pipe Diameter - Liquid (Flare) - in [mm] ø 3/8 [9.52] Connection Pipe Diameter - Gas (Flare) - in [mm] ø 5/8 [15.88] WEIGHT AND DIMENSIONS Connection Pipe Diameter - Drain (ID; OD) - in [mm] ø 1/2 [12] Enclosure - Net Weight - lbs [kg] 33 [15] Drain-Pump Optional Enclosure - Gross Weight - lbs [kg] 42 [19] Dimensions - Net (H x W x D) - in [mm] 12-5/8 39-5/16 9 [320 998 228] ETL Dimensions - Gross (H x W x D) - in [mm] 12-9/16 42-15/16 16-7/8 E.T.L. 91986 [319 1,090 429] TEMPERATURE SETTINGS Operating Temp. Cooling (DB) - F [ C] 64 to 90 [18 to 32] Operating Temp. Heating (DB) - F [ C] 50 to 86 [10 to 30] Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal ASUB24TLAV Wall (24,000 BTU) Indoor Unit For Heat-recovery/Heat-pump Airstage VRF System DIMENSIONS Unit: In. (mm) 9/8/2016 Rev. D Fujitsu general America, Inc. 353 Route 52 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Variable Refrigerant Flow System Submittal Data: UTP-BX180A Separation Tube 96,500 to 193,000 Btu /h Job Name: Location: Engineer: Submitted to: Submitted by: Separation Tube Date: Approval: Construction: Unit #: Drawing #: Reference: Separation Tube for 3 Pipes UTP-BX180A Port Dimensions Rev. date 06/01/15 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447
Variable Refrigerant Flow System Submittal Data: UTP-BX180A Separation Tube 96,500 to 193,000 Btu /h Separation Tube Heat Insulation Dimensions Rev. date 06/01/15 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447
UTP-DX567A Submittal Airstage Project - 9217 Outdoor Unit Branch Kit Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #: Fujitsu General America, Inc. Toll Free: 1-888-888-3424 Fax: (973) 836-0447 Airstage.fujitsugeneral.com
Variable Refrigerant Flow System Submittal Data: UTP-RU04BH RB Unit Branch Box Job Name: Location: Engineer: Submitted to: Submitted by: Date: Approval: Construction: Unit #: Drawing #: Reference: General Features Small and slim design saves space Drain pipe not required The control box position can be changed to meet installation conditions Freedom to mount control box from either side Electrical...... 208/230V AC 1ph-60HZ Available Voltage Range.......... 187 / 253V AC Input Power..... 110 W Running Current.... 0.8 A PCB Fuse.. 3.15A x4 250V x4 Capacity Number of branches.... 4 Maximum number of connected indoor units...... 8 Maximum capacity of connectable indoor units.... 191,000 Btu/h*1 Maximum capacity of connectable indoor units per branch..... 60,000 Btu/h Refrigerant Type. R410A Connection Pipe Outdoor Unit Side Suction Gas Pipe.... 1-1/8 (28.58 mm) Discharge Gas Pipe...... 7/8 (22.22 mm) Liquid Pipe... 5/8 (15.88 mm) Indoor Unit Side Gas Pipe.... 3/4 (19.05 mm) Liquid Pipe..... 3/8 (9.52 mm) Method....... Brazing Wiring Communication Cable... LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Operation Temperature Range..... 5 F - 115 F (-15 C - 46 C) Installation Locations.... Indoors only Dimensions H x W x D Uncrated in. (mm)...... 10-1/4 x 25-7/8 x 16-7/8 (260x658x428) Crated in. (mm....... 13-11/16 x 49-3/16 x 30-1/2 (348x1250x775) Weight Net....... 70 lbs. (31.5 kg) Gross....... 88 lbs. (39.5 kg) ETL ETL Number..... 4008208 Unit in. (mm) 5-7/8 (150) Unit in. (mm) Rev. date 03/15/16 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447
Job Name Location Engineer Submitted To Submitted By Reference Submittal AOUA168TLBVG 14 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) 1X (AOUA72TLBV) + 1X + 1X (AOUA96TLBV) (AOUA96TLBV) Date Approval Construction Unit No Drawing No Inverter driven compressor New style high power DC fan motor. Blue fin heat-exchanger (Corrosion resistance) 10 Year warranty on parts and compressor. See Warranty Statement for details. Optional: Internet, BACnet, LonWorks, or Modbus communication. Outdoor separation tube must be ordered separately (UTP-DX567A). CAPACITY OPERATING TEMPERATURES Nominal Cooling Capacity - BTU/h [kw] 168,000 [49.2] Operating Temp. Cooling (DB) - F [ C] 14 to 115 [-10 to 46] Nominal Heating Capacity - BTU/h [kw] 189,000 [55.1] Operating Temp. Heating (DB) - F [ C] -4 to 70 [-20 to 21] Nominal Tonage - Ton(s) 14 Operating Temp. Cooling/Heating Simultaneous - F [ C] 14 to 70 [-10 to 21] Maximum Connectable Indoor Units 26 Connectable Capacity 50% to 150% EFFICIENCY Cooling Power Input - kw 14.03 EER Cooling (Ducted/Non Ducted) 11.0/11.0 Heating Power Input - kw 13.93 IEER Cooling (Ducted/Non Ducted) 22.20/20.0 Unit Group 1X (AOUA72TLBV) + 1X (AOUA96TLBV) COP / High Heating 47 F 3.48/3.48 SCHE (Ducted/Non Ducted) 22.0/22.0 ELECTRICAL Voltage Range 187 to 253 VAC WIRING Maximum Circuit Breaker - A 2X (50) each Communication Cable LonWorks (Fujitsu Pink Cable. See AE Bulletin 009) Minimum Circuit Ampacity (MCA) - A 2X (41) Cooling Power Input - kw 14.03 Heating Power Input - kw 13.93 PIPING Maximum Starting Current (MSC) - A 2X (33.2) Max. Total Refrigerant Line Length - ft [m] 3,280 [1,000] Compressor - Rated Load Amperage (RLA) - A 1X (17) + 1X (25) PipeConnection:Max Height Diff. (ODU & ID)(Upper/Lower) - ft [m] 164/131 [50/40] Fan Motor - Full Load Amperage (FLA) - A 2X (1.5) Pipe Connection Method: Liquid/Gas Brazed Pipe Connection: Liquid - in [mm] 5/8 [15.88] COMPRESSOR Pipe Connection: Discharge Gas - in [mm] 7/8 [22.22] Compressor Type 2X Rotary Inverter Pipe Connection: Suction Gas - in [mm] 1-1/8 [28.58] Refrigerant Type R410A Refrigerant Charge - lbs [kg] 2X (26.01 [11.80]) SOUND Compressor Crankcase Heater - W 2X (2X 35) Sound Pressure Levels (Cooling/Heating) - db(a) 61 / 62 Refrigerant Oil / Lubricant POE Compressor Capacity Control - Steps/Range 951 / 20-115 (per unit) WEIGHT Net Weight - lbs [kg] 2X (597 [271]) FAN Gross Weight - lbs [kg] 2X (642 [291]) Fan Type 2X Propeller fan Fan Airflow Rate - CFM [m3/h] 2X (6,533 [11,100]) DIMENSIONS Fan Power Output - W 2X (740) Dim.Net (HxWxD) - in [mm] Fan Motor - Full Load Amperage (FLA) - A 2X (1.5) External Static Pressure (Max) - in.wg [Pa] 0.32 [80] HEAT EXCHANGER Dim.Gross (HxWxD) - in [mm] 2X (71-5/16 39-7/16 33-3/8 H. E. Pipe Type (Material) Grooved H-pin (Copper) [1811 1002 847]) H. E. Fin Tube (Material) Corrugate (Aluminum) H. E. Fin Surface Treatment Corrosion resistance (Blue fin) H. E. Fin Pitch - FPI [mm] 18 [1.45] CODE H. E. Rows x Stages 2X (3 x 60) ETL 3170288 H. E. Face Area - Ft² [m²] 2X (23 [2.2]) AHRI Certified Standard 1230 H. E. Length - in [mm] 2X (69-5/16 [1760]) Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80 F (26.7 C) DB/67 F (19.4 C) WB, and outdoor temperature of 95 F (35 C) DB/75 F (23.9 C) WB. Heating: Indoor temperature of 70 F (21.1 C) DB/60 F (15.6 C) WB, and outdoor temperature of 47 F (8.3 C) DB/43 F (6.1 C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit). 2X (66-9/16 x 36-5/8 x 30-1/8 [1690 x 930 x 765]) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Submittal AOUA168TLBVG 14 Ton Heat Recovery Outdoor Unit - 208/230 VAC, 3-Phase, 60Hz 1X (AOUA72TLBV) + 1X (AOUA96TLBV) DIMENSIONS Unit: In. (mm) 8/18/2016 Rev. G Fujitsu General America, Inc. 353 Route 46 West Toll Free: (888) 888-3424 Fax: (973) 836-0453
Variable Refrigerant Flow System Submittal Data: UTY-DTGYZ1 Job Name: Location: Engineer: Submitted to: Submitted by: Touch Panel Controller (with Internet Communication) Date: Approval: Construction: Unit #: Drawing #: Reference: General Features Electrical Power.... 100-240 AC volts 1ph-50/60HZ Input Power... 22W Fuse Capacity.. 5A Display Screen...7.5-inch TFT color LCD display (640 x 480 pixels), with Touch panel Temperature Cooling Setting Range... 64 F - 88 F (18 C - 30 C) Heating Setting Range........ 48 F - 88 F (10 C - 30 C) Humidity range... 0 to 85% (no condensation Ethernet RJ45 External Interface External In.. (Either emergency stop or batch stop operation/stop) External Out... (Operation state, error state) USB Port..USB 2.0 Dimensions H x W x D In (mm) 10-1/4 x 9-11/16 x 2-1/8 (260 x 246 x 54) Weight... 5lbs. (2150 g) Maximum Controllable Indoor Units Heat-Pump.. 400 indoor units Heat-Recovery 320 indoor units Touch panel controller with built-in Internet output provides VRF remote monitoring and control capability. The VRF system can be remotely monitored and controlled via LAN or WAN from remote PC with an Internet Browser. It can be used to control the cooling & heating, ON/OFF, Auto, Fan speed, Temperature setting, Air flow direction, Timer set-up for up to 24hr in advance. Up to 16 UTY-DTGYZ1 touch panel controllers can be connected per VRF system. Can control and monitor up to 400 Indoor units. Can control and monitor up to 100 Outdoor Units. Error contents are notified automatically by E-mail to be handled promptly. Equipped with LCD touch panel screen and stylish shape and design. Programmable in 7 different languages: English, Chinese, French, German, Spanish, Russian & Polish. FEATURES Automatic clock and summer time adjustment Outdoor Unit low noise setting function Easy Operation Wide range of easy to understand icons Finger or dedicated touch pen selections Two background colors identifying the control operation blue for monitoring & green for operational control Function Individual control Flexible grouping Schedule control Indoor units control & monitoring Versatility Emergency stop function Stored data can be transferred via the Internet and USB port CSV format data edited by PC can be imported to the to the Touch Panel Controller Easy Installation No external 4x4 box is required. Mounts flush to wall. OPTIONAL: Electricity charge apportionment function can be added purchasing UTY- PTGXA. In addition a pulse electric meter is required to measure the Outdoor Unit power consumption. Rev. date 8/09/16 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447
Variable Refrigerant Flow System Submittal Data: UTY-DTGYZ1 Touch Panel Controller (with Internet Communication) Dimensions Terminal Names Names of connection terminals inside rear cover. External Inputs Terminal External input terminals are available for all ON/OFF and Emergency stop commands. Rev. date 8/09/16 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447
Submittal UTY-RNRUZ1 Wired Remote Controller (Touch Panel) Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Date: Approval: Construction: Unit #: Drawing #: General Features Wired touch screen remote controller with backlight that connects to the VRF indoor units using 2-wires. Individual or group control of up to 16 indoor units. Temperature Setting Range Cooling F ( C).. 64-88 (18-30) Heating F ( C )... 48-88 (10-30) Weight and Dimensions Weight oz (g).. 8 (220g) Dim.Net (HxWxD) in(mm)... 4-3/4x4-3/4x11/16 (120x120x20.4) Electrical Input Voltage DC V. 12 Power consumption W. Max 0.3 Wire Size AWG (mm²) 22 to 16 (0.33 to 1.25) Non polar 2 core sheathed twisted pair cable Thermostat Wiring AWG (mm²) 18 (0.75) 2 core sheathed non twisted pair cable Display. 3.8 inch backlight LCD Touch display (255x160 dots) Operation modes: Auto/Cool/Dry/Fan/Heat Various timer setup (on/off/weekly) are possible Auto ON or OFF timer this feature is used to start/stop the indoor unit operation for early boost/startup or early shutdown. Weekly timer: a. Start/stop function twice per day b. Operating time can be set in 30-minute increments c. The OFF timer can be carried over to the next day Vacation schedule Built-in Temperature sensor. Sensing can be set to measure temperature at the Remote or at Indoor unit. Additional Custom Settings: - Set temperature Auto Return - Set temperature Range Setting, - Away Setting, - Error History, - Anti Freeze, - Filter Reset, - R.C. Master/Slave Setting, - Language Setting. This remote controller is compatible with all VRF A***TLAV indoor units. This remote controller is not compatible with all VRF A***RLAV indoor units. Rev. 9/20/16 1 of 2 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447
Submittal UTY-RNRUZ1 Wired Remote Controller (Touch Panel) DIMENSIONS (a) (b) (c) (d) (a) (b) (c) (d) Room temperature sensor Operation (occupied/unoccupied) button LED lamp (operation indicator) Touch panel display Rev. 9/20/16 2 of 2 Fujitsu General America, Inc. 353 Route 46 West Toll Free: 1-888-888-3424 Fax: (973) 836-0447