Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

Similar documents
The Amerex Advantage - Quality Experienced Innovation Made in the USA

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

TUNPROTEC. Active Tunnel Fire Protection

Fire protection for buildings

Affordable fire suppression solutions

Dual Agent Unit w / Atmospheric Tank 200 Litres DAHR 01

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

WATER MIST CONVENTION AND EXHIBITION

Basic Vehicle Fire Protection Manual

A Guide for Meeting NFPA 10 Subsection

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

CARTRIDGE EXTINGUISHER

Foam Products ENGLISH

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

Leader s Guide 2007 CLMI Training

Fire protection on chemical manufacturing sites

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Mist-Tech Fire Fighting Equipment

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

Ceasefire Watermist Hydrant Systems

Low Pressure INNOVATIVE FIRE PROTECTION SOLUTIONS in the. Woodworking Industry INNOVATIVE FIRE PROTECTION. VID Fire-Kill. Denmark.

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

The Science Behind Water Mist Protection of Typical Building Hazards

What is HI-FOG? The natural enemy of fire

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

STANDARD: 5.2.1(B) TASK:

Fire fighting excellence. HI-FOG water mist fire protection

BlueHeat Coolant Heater

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Airport Firefighter Recertification Core Competency Task Book

User manual Contractor s machinery / vehicles, tooling machines and special machines

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Tel Web: dyayan.com

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

Table Top Patio Heater

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

CORE Protection Fire System Specification

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Fire & Utilities Instructions

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

Firefighting. It is the temperature at which a substance will continue to burn, when ignited.

Design and Supply of Fire Equipments. External Fire Fighting Systems.

FIGHTING FIRE as easy as blowing out a match

SECURITY BLANKET Foam Fire Protection Products

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

BASIC SYSTEM LOCATION INDEX

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

Fire Protection for Printing Machines with High Pressure Water Mist

Service Bulletin No. 2930

Fire Safety HDT Rally Jack Mayer, jackdanmayer.com

Fire fighting excellence. HI-FOG water mist fire protection

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

Deluge & Preac tion Systems

Emergency shutdown systems. Procedures for bypassing ESD s

Reliance Fire Protection Systems


2G & 3G GSM Door Contact Alarm

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

St. Vincent s Health System Page 1 of 6

Bid Specifications for Thermo-Lay model UD /4 yard truck mounted machine with hydraulic bins & roller DIMENSIONS: Body:

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Fixed High Volume Water Spray System fireward.co.uk

FIRE SUPPRESSION SYSTEM

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

AFEX. fire suppression systems AFEXSYSTEMS.COM

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

MORE THAN JUST FIRE PROTECTION

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

Bus/Motorhome Fires Prevention, Detection and Suppression

PROTECCIÓN DE RIESGOS ESPECIALES AUTOMATIC FIREFIGHTING SYSTEMS IN VEHICLES. con tubo de detección

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

AIRCRAFT RESCUE AND FIREFIGHTING

Twin-Agent Fire Fighting/Securing Systems Specifications

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

Installation Instructions Part No , Part No Part No

Transcription:

Applications: The VID FIRE-KILL Model BPS is suitable for protection of engine rooms in busses, trucks, etc. System description: The VID Fire-Kill Model BPS system is a little local application fire extinguishing system designed for fast response fire fighting in mobile machinery spaces, such as in trucks and busses and entrepreneur machineries etc. The System is a 7 bar air pressurized standalone system which automatically fights fires in engine room compartments with sprays of: Water Mist with 3% foam enhancement (AFFF), where the water mist provides good cooling in the well ventilated engine room compartments and the foam enhancement provides good fire extinguishing in locations where fuel assembles in minor pools hidden to direct sprays hidden, and provide fast fire knockdown and protection against fires reigniting. General Stats Power Supply 12-24 Vdc / 2 A Backup Battery Life 24 H Water Reserve 15l w. 3% AFFF Tank Size 25 l Tank Pressure 7 bar Nozzle pressure 4 bar Std. Nozzles 4x K1 Nozzle Std. water use 5.5 8.l/min Page: 1 of 5

System characteristics: The VID Fire-Kill Model BPS System is designed to be: - Installed in small spaces - Rigid and reliable - To be simple to install and maintain using ordinary tools, - To require low maintenance. - To be simple and easy to set back to service after activation - To provide capabilities of monitoring and control from drivers. - To provide safe automatic double knock electrical fire detection and activation. - To have redundant sprinkler activation capability from reliable non electric glass bulb system activation. Power supplies: The VID Fire-Kill Model BPS system is designed for 24 VDC 8W power supply from the vehicle s power supply. The VID Fire-Kill Model BPS, fire detection and system activation system has built in 24 power supply. Electrical power from the vehicles own power supply system is applied to: 1. Maintain power on battery integrated in the electrical fire detection and system activation panel. 2. Small Air compressor maintaining 7 bar air pressure in agent storage tank, to propel the extinguishing agent to the water mist nozzles in the engine compartment when a fire has been detected. 3. To supply power for manual system activation from the driver seat, or from other release switch located in accordance with the owners wishes. Page: 2 of 5

System: The VID Fire-Kill Model BPS system is designed to provide fire protection in small engine rooms. The system consists of 3 parts. Detection and activation system includes: An electrical panel which includes a 24h backup battery. The panel have two outputs and one input. The two outputs are the alarm signal to the driver and the activation signal to the activator valve. The input is a thermocouple which is used to detect the fire in the engine room. The detector works as a double knock system. First parameter required is a minimum temperature and thereafter a Rate of Rise (Δ T) is needed. The ΔT value needed is pre-set from factory. Supply unit includes: A 25l stainless steel tank filled with 15l premix of pure water and 3% AFFF. The tank is fitted with an input valve and an output valve section. The input valve section includes a fill/drain valve, an air compressor, a check valve between the compressor and the tank and a pressure switch which turn on the compressor if the pressure in the tank becomes too low. The output valve section includes a pressure gauge and an activator valve for the water mist nozzles. The system activation valve has electrical controlled release function as well as build in activation from high temperature glass bulb, to provide the fire fighting system with electrical independent activation redundancy. The system activation valve is installed in line between the pressurized agent storage tank and the water mist nozzle system protecting the engine room compartment. Firmly attached to a solid construction element with rubber shock absorber bolts Inside the fire protected machinery compartment, to allow the glass bulb be heated from fire in case of a fire in the engine compartment. The Active water mist system includes: A hose or Cu-Pipe in a length specified by the costumer to connect the tank supply unit to the system activation valve, and to the water mist pipe and nozzle system. 1,5m ø12mm pipe stainless steel piping for custom design of a pipe system to match the engine compartment. Four Stainless steel fittings and 4 VID Fire-Kill model K1 low pressure water mist nozzles. The system pipe system are installed in the engine compartment with the water mist nozzles located above the engine to provide full wetting of all surfaces in the engine compartment. Additional nozzles and fittings, as well as larger storage tanks are optional available on orders. The nozzle system shall be firmly attached to ridged construction elements, or the engine block. The agent pressure tank should be firmly attached to ridged construction elements, and there should be no more than 5m from the agent pressure vessel to the nozzle system. There should be no sharp bends on the hose or pipe connecting the agent vessel to the activation valve, and the activation valve to the nozzle pipe system. The agent vessel should be located with the nozzle pipe connection in the lowest position. Page: 3 of 5

The air compressor should be connected to the pressure vessel, and there should be no bent on the hose or pipe connecting the two elements. As standard the air compressor are supplied attached to the pressurized agent supply pressure vessel. Optional: the Air compressor is supplied as a lose component, to be hose connected to the agent pressure tank vessel. The air compressor is controlled from a pressure switch attached to the agent pressure vessel, to maintain 7 bar air pressure in the pressure vessel. The air pressure is connected to the 24VDC 8W power supply of the vehicle, to maintain the air pressure in the vessel. Optional: a pressure transducer is connected to the vessel, for monitoring the air pressure in the system. Standby position: In standby position the system measures the temperature in the engine room. In standby position the system pressurizes itself if needed. In case of too low pressure in the tank, the pressure switch activates the air compressor until the pressure is high enough. The pressure switch is set to 7 bar. In case of fire: If a fire ignites in the engine room, the thermal sensor installed, automatically detects the temperature rise. When the temperature reaches the pre-set alert temperature (Ta), the system automatically switches to Alert Mode. Ta is as standard set to T normal + 30 degrees. In Alert Mode the system monitors the rise of heat and if the rise of heat reaches a pre-set value (ΔT), the system automatically send an alarm signal to the driver. The systems supplies relay signal which can be used to give sound or light alarm. The system does also give a signal to the operator valve on the tank to open (Signal: 12VDC, 2amp). Opening the valve lets water flow into the hose and out to the pipe and nozzle system which then distributes fine water mist with AFFF onto the engine block and in the total engine room. The fine low pressure water mist with agent instantly suppress and extinguish the fire. For reset of the system a new supply tank unit including valves should be installed. Hydraulic design: When the system activates the tank has 7 bar pressurized air inside. Depending on the hose length the pressure at the nozzles will be around 2-4 bar. The standard system, which includes 4 nozzles of the type K1, will at that pressure use approximately 5.5-8 l/min. This will give the system a total operation time of approximately 2-3 minutes. Power consumption: Both the detection and activation panel as well as the air compressor operates on 12-24 VDC/ 2A. This power can be supplied by the vehicle battery/power supply. Additional options: If needed a manual release button can be supplied, so the system can be operated manually by the chauffeur. This solution does also include fire indicator at the release button position. Page: 4 of 5

Service and maintenance: Service and maintenance should be done by a manufacturer trained operator, and should be done every year. At the yearly service, following should be checked: Contact For further information on the Model BPS system or related products, please contact our sales department at Sales@vidaps.dk - The back-up battery. - Tank pressure. - Compressor operation. - All wire connections. - All pipes connections. - The flexible hose. - The nozzles on the pipes. After system activation: It is checked that the activation sounds alarm and activation signal when the thermo sensor is heated. The activation valve is replaced with new, and electrical resistant of electrical connections to the release valve is checked, not to be broken. (max 100MA testing power) The vessel is refilled with 15 litres of clean fresh water with 3% AFFF Foam enhancement. It is checked that pressure builds up in the pressure vessel, and that all pipe joints are leak poof. Caution If the Model BPS has been compromised or is suspected compromised, the part should be replaced and returned to the manufacturer for further testing. Page: 5 of 5