Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL Condenciat units with air-cooled condensers are designed for small sized refrigerating installations. They are particularly suitable for industrial process, small shops, offices, restaurants. Installed outdoors (propeller fan), they are directly connected, through refrigerant piping, to a direct water or air expansion exchanger. They can be combined with a wide variety of indoor exchangers: Air handling box coil Separate water cooling evaporator, EXEL, HF, FYN types Integrated into a precision air handling cabinet such as Expair. Any type of comfort unit of equivalent capacity We remind you that the control of air handling units should be studied with care when the direct expansion solution has been selected. Description Standard equipment Scroll compressor Crankcase heater on 50-65 - 75 models Air-cooled condenser, copper tubes coil, aluminium fins Direct drive propeller fan(s) - ( or according to the model) Year-round operation Condensing pressure control through fan speed variation (pressure sensor) Refrigerant connections (FLARE connectors) Operation for outside temperatures between: - 5 C and + 45 C Casing in ABS synthesis material, recyclable and UV stabilised, light and sturdy. Its exclusive and high-quality design facilitates its integration into its surroundings. Conforms to norms and directives : à CEM 004/08/EC à BT 006/95/EC à DEP 97/3/EC Optional equipment Antivibration mounts Crankcase heater on models 0, 8, 35 Wall support (models 0, 8, 35) Thermostatic expansion kit heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - na.59 a
Quick selection CONDENCIAT CL CL Number of circuits Number of compressors Cooling capacity (KW) Power consumption (KW) 0 5..8 8 6.8.6 35 8.6 3.5 50. 4 65 4.5 4.9 75 8.6 6.8 CL refrigerant fluid R40A Evaporation temperature + C DB air temperature at condenser = +35 C Connection Condenciat Max height 30 m Max equivalent length 50 mevaporator Equivalent length for 90 angle Tube diameter (inches) /4 3/8 / 5/8 3/4 7/8 Equivalent length (m) 0.5 0.35 0.45 0.55 0.65 0.7 All the network accessories must be taken into account heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - na.59 a
Cooling capacities R40A CL 0 8 35 50 65 75 Evaporating temperature ( C) Condenser inlet temperature ( C) 5 30 35 40 45 Pf Pa Pf Pa Pf Pa Pf Pa Pf Pa kw kw kw kw kw kw kw kw kw kw - 5..4 4.8.6 4.5.8 4..0 3.8. 0 5.5.5 5..6 4.8.8 4.4. 4..3 6.0.4 5.5.6 5..8 4.8. 4.4.3 4 6.3.5 5.9.7 5.5.9 5.. 4.8.3 6 6.6.5 6.3.7 5.9.9 5.5. 5..3 8 7..5 6.8.7 6.3.9 5.9. 5.5.3 0 7.6.5 7..7 6.8.9 6.3. 5.9.3-6.8.0 6.4.3 5.9.6 5.6.9 5. 3.3 0 7.4.9 6.9.3 6.4.6 5.9.9 5.5 3. 7.9.9 7.3.3 6.8.6 6.3 3.0 5.8 3.3 4 8.3. 7.8.3 7.3.6 6.8.9 6.3 3.3 6 8.8. 8.3.4 7.8.6 7. 3.0 6.6 3.4 8 9.5. 8.8.4 8..7 7.7 3.0 7. 3.4 0 9.9. 9.3.4 8.7.7 8. 3. 7.6 3.4-8.5.8 8.0 3. 7.4 3.5 6.9 3.9 6.4 4.3 0 9..8 8.5 3. 8.0 3.5 7.4 4.0 6.9 4.3 9.7.8 9. 3. 8.6 3.5 7.9 4.0 7.3 4.4 4 0.3.9 9.7 3. 9. 3.6 8.4 4.0 7.7 4.5 6..8 0.5 3. 9.6 3.6 9.0 4.0 8.3 4.5 8.6 3.0 0.9 3.3 0. 3.7 9.5 4. 8.7 4.6 0. 3.0.5 3.4 0.8 3.8 0. 4. 9.3 4.6 -.0 3..3 3.5 0.6 3.9 9.9 4.4 9.0 5.0 0.9 3.. 3.5.4 3.9 0.6 4.4 9.8 5.0 3.6 3..9 3.6. 4.0.3 4.5 0.5 5.0 4 4.4 3. 3.7 3.6.9 4.0.0 4.5. 5. 6 5.5 3. 4.5 3.6 3.7 4..8 4.5.9 5. 8 6.5 3. 5.4 3.7 4.5 4. 3.6 4.6.6 5. 0 7. 3.4 6.3 3.8 5.3 4. 4.4 4.6 3.4 5. - 4.4 3.9 3.6 4.3.7 4.7.7 5. 0.8 5.7 0 5.4 3.9 4.5 4.3 3.6 4.8.6 5.3.7 5.8 6.7 3.9 5.5 4.4 4.5 4.9 3.5 5.3.4 5.9 4 7.4 4. 6.4 4.5 5.4 4.9 4.4 5.4 3.4 5.9 6 8.5 4. 7.5 4.6 6.4 5.0 5.4 5.5 4. 6. 8 9.9 4. 8.8 4.5 7.4 5. 6.3 5.6 5. 6. 0. 4. 9.6 4.7 8.5 5. 7.3 5.7 6. 6. - 8.7 5.4 7.5 6.0 6.3 6.6 4.9 7.4 3.5 8. 0 9.7 5.6 8.4 6. 7.4 6.7 6.0 7.5 4.7 8.. 5.6 9.9 6. 8.6 6.8 7. 7.6 5.8 8.3 4.5 5.7. 6.3 9.7 7.0 8.4 7.6 6.7 8.5 6 3.9 5.8.4 6.4 0.9 7. 9.3 7.9 8.0 8.5 8 6.0 5.7 3.8 6.5. 7. 0.5 7.9 8.8 8.8 0 6.7 6. 5. 6.7 3.5 7.3.8 8. 9.9 8.9 Pa: total absorbed capacity of the CL unit (compressor + fan + control) Pf: Cooling Capacity heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - na.59 a 3
Technical characteristics CONDENCIAT CL 0 8 35 50 65 75 Number Compressor Type SCROLL Oil capacity l..5.7 Oil type POE Refrigerant fluid R40A Refrigerant weight Kg.00.00 Power and intensity Crankcase heater Coil type Fan Type W/A 45W / 0.A Optional () Copper tubes - aluminium fins Propeller - direct drive 45W / 0.A Number Flow m 3 /h 450 970 500 5890 580 Speed Rpm 78 897 78 897 Weight of unit Kg 64 69 69 0 8 Connection ø Liquid line Inches /4 3/8 / ø Intake line Inches / 5/8 3/4 7/8 () This option is compulsory if the total refrigerant charge exceeds 4,5 Kg Electrical characteristics CONDENCIAT CL 0 8 35 50 65 75 Compressor Unit nominal voltage 400 V - 3 Ph - 50 Hz Max. intensity A 4.4 6.9 7.6 0.3. 4.3 Fans Max. intensity A 0.47 0.66 0.94.3 Nominal voltage of unit V 400 V - 3 Ph + N - 50 Hz Intensity A 5.0 7.5 8.3.3.6 5.7 Starting intensity A 7 36 49 65.5 75.5 0.5 Electrical cables not supplied * mm 5G.5 5G.5 5G4 5G6 Proximity switch recommended rating Am 6 0 6 0 * cable with or 3 conductors in a raceway or exposed mounting, for temperatures below 60 C, 30 m max. length Note : For other conditions, refer to the norm applied in the country of installation (example for France : NFC 5.00) Sound pressure levels ** CL 0 8 35 50 65 75 Acoustic pressure db(a) 43 49 49 47 5 5 ** at 5m from the unit,.5m from the ground, free field, directivity. 4 heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - na.59 a
Dimensions Models 0, 8 and 35 I H C D G F B E A Models 50, 65 and 75 I H G C D F B E A CL A B C D E F G H I 0, 8 and 35 035 449 658 30 60 375 030 5 350 50, 65 and 75 035 449 58 30 60 375 030 5 350 EXTERNAL AIR FLOW LIQUID LINE SUCTION GAS LINE heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - na.59 a 5