Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Similar documents
Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data Ducted Three Phase Split System Air Conditioner

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Ducted Split System Air Conditioners Technical Data

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Ducted Split System Air Conditioners Technical Data

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

EC Motor Fan Coil Units. IMD-Y Series l/s

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Packaged Air Conditioning Custom Build Solutions

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

PRODUCT RANGE: ROOFTOP PACKAGE

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

EC Motor Fan Coil Units. IMDL-Y Series l/s

ROOFTOP PACKAGED AIR CONDITIONERS

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Remote Air Cooled Condensers C2 Series

Air Cooled Packaged Units

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

OPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Modular Air Cooled Scroll Chillers

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

Condensing Units CUS 15-60

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

HYDRONIC RESIDENTIAL

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Roof top SPACE RPC 450Z R407C M011

GUIDE SPECIFICATIONS AQUARIUS ii

Product Data. Fig. 1 - Unit 50VR -A

Air Cooled Chillers & Heat Pumps WinPACK HE-A

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

High temperature air-to-water heat pumps

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

PAR5. Product Specifications

LZA High efficiency air to water heat pumps with HP compressor

50TM TFF COMBINATION HEATING/COOLING UNITS

LZT High efficiency air to water heat pumps with E.V.I. compressors

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

50TM COMBINATION HEATING/COOLING UNITS

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Ducted inverter reverse cycle air conditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Commercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Commercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TOSHIBA AIR CONDITIONING

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

TOSHIBA AIR CONDITIONING

Water Cooled Air Conditioners Applications Manual

PAJ3. Product Specifications

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Kirby Commander Condensing Unit

R4H4. Product Specifications

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

AQUASNAP JUNIOR 30RHV

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Commercial HERCULES. The brains and brawn redefining air conditioning efficiencies. That s better. That s Actron.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

WALL-MOUNT HEAT PUMPS - (60HZ)

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Roof top SPACE RPC 315Z R407C MA00

CHAPTER 6 CONDENSING UNITS

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

VariCool VAV Engineering Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Transcription:

Ducted Three Phase Packaged Air Conditioners Technical Data 96 RKTBG-P Plug Fan with High Efficiency EC Motor and High External Static Economiser Option TZT Controller & Digital Scroll Compressor for close temperature control Nominal Cooling Capacity 47 kw 96 kw JANUARY 216

, 55, 75, 855, 96 - ECO SERIES DUCTED PACKAGED ROOF TOP CONDITIONER GENERAL This OPA Series is a range of reverse cycle (heat pump) packaged roof top air conditioner designed and developed to comply with AS/NZS 38 specified conditions. The system has been tested and proven for cooling operation in outdoor temperatures up to 5 C. APPLICATIONS These units have been specifically developed for air conditioning of commercial premises, e.g. banks, supermarkets, shopping malls, food outlets, auditoriums and restaurants. These Digital models are particularly suitable for applications requiring full or high proportions of fresh air, VAV, close control and supply air temperature control. Air Flow Selection If the air returning to the indoor coil is regularly expected to be above 5%RH, then the coil face velocity should be limited to be 2.5 m/s or less (refer Air Flow graph; 2.5 m/s is clearly marked). High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. FEATURES Refrigerant R41A. Each system uses refrigerant R41A which is deemed to have zero ozone depletion potential. Economy. Each OPA unit has two independent refrigeration circuits to provide the flexibility and economy of two stage operation, i.e. utilising one or two circuits as conditions vary, plus the advantage of staggered starting. An economiser option is available to lower operating costs further during the cooling cycle. Efficient. Heat exchange coils incorporate inner grooved (rifled) tube for better heat transfer. The indoor air coil is interlaced for efficient part load performance. Performance. The system includes two compressors, one of which is Digital thereby providing % variability and closer temperature control. The OPA also uses a backward curved plug fan for fine tuning of the indoor air to match higher static pressure supply air requirements. These EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 1V DC control signal. Electronic expansion valves (EEV) assist in optimising refrigerant flow. The system includes a digital temperature sensing head pressure control (via pressure transducers) which enables the system to compensate for outdoor ambient temperatures below 2 C on cooling cycle, and above C on heating cycle. Quiet. Each EC plug fan can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The motor can be controlled to have the best air flow for the ducting and requirements as well as used for de-humidifying the space. A large aperture supply air spigot reduces exit velocities and therefore less noise down ductwork. Generous use of insulation also ensures a quiet unit. Durable. The cabinet and drain tray are constructed from high grade galvanised steel - polyester powder coated (colour Grey) for increased durability. External fasteners are stainless steel. The unit includes a polyester powder coated drain tray. Heat exchange coils comprise aluminium plate fins on mechanically expanded rifled copper tube. The outdoor coil fins are epoxy coated for extra protection in corrosive environments, eg salt laden sea air. Outdoor coil hail protection guards are supplied. Insulation. Closed cell foam insulation has been used in the indoor air section to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 3.3 (89) and BS 476 parts 6 & 7. Lower Installation Cost. A large supply air spigot which lessens the need for duct transitions. Low Maintenance. Commissioning and maintenance costs are reduced through use of a fan that requires no pulley and belt adjustments or changes like traditional fans. Control Option. Fixed and stable air flows can be achieved through use of a differential pressure transducer and controller (supplied by others) to compensate for varying duct static pressures caused by dirty filters or modulating dampers. Commissioning is also made easier. The EC plug motor is controlled variably by a 1 volt DC signal supplied by, or via, the unit's UC6 Controller. This UC6 controller is BMS compatible with multi-unit control possible either via digital and analogue signals or via Modbus. Refer to temperzone for other protrocols available. Self Diagnostics. The OPA's Unit Controller (UC6) has a 7 segment LED display to indicate faults and running conditions. Many operating status conditions (including history) can be determined, without gauges, simply by using the built-in Service Interface graphical display. OPTIONAL 1. temperzone TZT- Controller kit. 2. Filters (rated EU4). 3. Economiser (factory fitted) - includes dampers, weatherhood. 4. Manually adjustable fresh air damper and weatherhood. 5. Electronic control systems - available by special arrangement. 6. Downward supply/return air with box mounting channel. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice prevents icing up of the outdoor coil during heating cycle. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Crankcase heater prevents liquid refrigerant condensing in the compressors during the 'off' cycle. 8. Compressor minimum run time to ensure oil return. 9. Phase rotation protection device. 1. 24V control circuit COMPRESSOR Each high efficiency scroll type compressor is hermetically sealed and supported on rubber mounts to minimise vibration. REFRIGERATION SYSTEM The OPA units are factory charged with HFC-41A (R41A) refrigerant. Electronic expansion valves (EEVs) control the flow of refrigerant. WIRING The electrical supply required is: 3 phase 38-4 V a.c. 5 Hz with neutral and earth. The compressor crankcase heater requires a 24 hour power supply. The unit's control panel is fully wired ready to accept the main power supply. ECONOMISER OPTION (Controls by others) If the outdoor air heat content or wet bulb temperature (dry bulb not recommended) is below that of the return air, the fresh air damper opens and the return air damper closes to provide the first stage of cooling. Operating costs are reduced as free cooling is obtained. (Note: A spill air facility in the building may be necessary for when the return air damper is closed.) Fresh air dampers close to a minimum setting and return air dampers open before normal compressor operation resumes The manufacturer operates a quality management system that conforms to AS/NZS ISO 91:28.

PERFORMANCE DATA COOLING CAPACITY (kw) Total = Total Capacity (kw) Sens. = Sensible Capacity (kw) E.A.T. = Entering Air Temperature = Nominal Capacity (kw) Note: Capacities are gross and do not include allowance for fan motor heat loss. For fan motor heat loss refer to Air Handling graphs. INDOOR FAN SPEED l/s INDOOR COIL E.A.T. D.B. W.B. C C COIL ENTERING TEMPERATURE C D.B. 35 39 43 2 28 37 42 52 45.8 36.2 45.2 36.2 43.9 35.5 41.9 34.3 39.1 32.4 35.7 29.9 48.2 35.4 47.6 35.4 46.3 34.8 44.3 33.7 41.5 32. 38.1 29.7 5.7 4.5 5.1 4.6 48.8 4. 46.7 38.8 44. 36.9 4.5 34.4 53.1 48. 52.5 48. 51.2 47.4 49.1 46.1 46.4 44. 42.9 41.2 55.1 43.5 54.3 43.5 52.8 42.7 5.3 41.2 47. 39. 42.9 36. 58. 42.5 57.3 42.5 55.7 41.8 53.2 4.5 49.9 38.4 45.7 35.7 6.9 48.7 6.2 48.7 58.6 48. 56.1 46.6 52.8 44.4 48.7 41.4 63.8 57.7 63.1 57.7 61.5 57. 59.1 55.4 55.8 52.9 51.6 5.1 7.7 55.8 69.8 55.8 67.6 54.6.5 52.7 6.2 5. 55. 46. 74.4 54.6 73.4 54.6 71.6 53.7 68.2 51.8.2 49.4 58.7 45.7 78.1 62.7 77.1 62.6 75.3 61.6 71.6 59.8 67.9 56.7 62.4 53..1 73.9 81.1 73.9. 73. 75.9 7.8 71.6 67.8 66.4 63.4 83.9 65.9.9 62.5 8.4.4 76.7 62.2 71.6 59. 65.4 54.3 88.4.4 87.3.4 85.1 63.4 81.1 61.2 76.3 58.3 69.8 53.9 92.8 74.1 91.7 73.9 89.5 72.3 85.1 7.6 8.7 67. 74.1 62.6 97.5 87.3 96.4 87.3 93.9 86.2 9.2 83.6 85.1 8. 78.9 74.9 94.8 74.4 93.5 74.4 9.6 72.8 86.5 7.3 8.8 66.6 73.7 61.3 99.7 72.8 98.5 72.8 96. 71.5 91.5 69.1 86.1 65.8 78.7 6.9 14.6 83.6 13.4 83.4.9.1 96..7 91.1 75.6 83.6 7.7 11. 98.5 18.8 98.5 15.9 97.3 11.8 94.4 96. 9.3 89. 84.6 Indoor Air Flow Correction Factors @ nominal conditions Indoor Air Flow (%) Total Capacity Sensible Capacity -2%.95.89-1%.975.95 Rated 1. 1. +1% 1. 1.5 INDOOR ENTERING TEMP. C D.B. 2 2 2 2 2 HEATING CAPACITY (kw) G = Gross Heating Capacity kw, based on nominal air flow. N = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw) COIL ENTERING TEMPERATURE (E.A.T.) C D.B. 5 3 1 1 3 5 7 9 G N G N G N G N G N G N G N G N 29.7.5 32.2.2 34.4.5 36.6 28.2 38.8 28.5 41.7 33.3 44.4 44.4 46.6 46.6 29.2.1.6 26.6 33.7 26.9 35.9.6 38.1 28. 4.9 3.7 43.5 43.5 45.7 45.7 28.1 24.1 3.4.7 32.5 26. 34.6 26.6 36.7 26.9 39.4 29.5 41.9 41.9 44. 44. 33.9 29.1 36.6. 39.2.3 41.7 32.1 44.2 32.5 47.5 37.9 5.5 5.5 53.1 53.1 33.2 28.5 35.9 3.3 38.4 3.7 4.9.5 43.3.9 46.6 34.9 49.5 49.5 52. 52. 32..5 34.6 29.2 37. 29.6 39.4 3.3 41.7 3.7 44.8 33.6 47.7 47.7 5.1 5.1 52.3 45.8 55.3 45.3 58.3 46. 61.3 48.9.2 55.2 67.2 65.7 7.2 7.2 73.2 73.2 51.3 45.2 54.5 44.7 57.5 45.4 6.5 48.3 63.5 54.6 66.5 65.1 69.4 69.4 72.4 72.4 49.9 43.9 52.9 43.3 55.9 44.1 58.8 47. 61.8 53.3.8 63.8 67.8 67.8 7.8 7.8 57. 49.9 61.8 53.1 66. 54.4 7.3 55.5 74.5 56.3 8. 62.2 85.2 66.5 89.4 89.4 56. 48.1 6.5 51.2.7 51.8 68.9 53. 73.1 53.7 78.5 58.9 83.5 83.5 87.7 87.7 53.8 47.2 58.3 5.1 62.3 51.4 66.3 52.4 7.4 53.1 75.6 55.2 8.4 62.7 84.4 84.4 61.5 53.8 66.6 57.2 71.2 58.7 75.8 59.9 8.3 6.7 86.3 67.1 91.8 71.6 96.4 96.4 6.3 52.7 65.3 56.2 69.8 57.5 74.3 58.7 78.8 59.5 84.6 61.7 9. 7.2 94.5 94.5 58.1 5.9 62.8 54. 67.1 55.4 71.5 56.5 75.9 57.2 81.5 59.5 86.7 67.6 91. 91.

PERFORMANCE DATA -P 2. 2.3 3.3 HANDLING Note: Airflows are for a dry coil. Reduce airflow by 5% in high moisture removal conditions. In a free blow or low resistance application, beware of exceeding indoor fan motor's full load amp limit (refer back page). As filters are optional, the fan air flows given are for units installed without filters. -P 1.7 2.5 3.5 kilowatts 4 1.2 3 1V 2.7 7V.4.6 1. 1.6 2.8 2 2 3 3 4 FLOW (l/s) Nominal 2.5 m/s Face Velocity 4 1.1 1V 3 3.4.7 7V 2 2.3.6 1. 1.5 2 2 3 3 4 FLOW (l/s) Nominal 2.5 m/s Face Velocity -P 2.2 3.1 4.2 -P 3.1 4.2 4 1.4 3 1.7 2 7V 3.5.6 1.1 1.7 2.5 2 2 3 3 4 4 FLOW (l/s) NOMINAL 2.2 m/s Face Velocity 4 2.2 3 1.4 1V 2 3.5.7 7V.6 1.1 1.7 2.5 2 3 3 4 4 FLOW (l/s) NOMINAL 2.3 m/s Face Velocity -P 4. 4.6 5.3 1V 4 2.3 3 4. 7V 2 1.1.8 1.2 2. 3 3 4 4 5 NOMINAL FLOW (l/s) 2.5 m/s Face Velocity

PERFORMANCE DATA OPTIONAL FILTERS - PRESSURE DROP Based on Koch Multi-Pleat HC filter. Max. final pressure drop Pa. PRESSURE DROP (Pa) 75 5 INITIAL (Clean Filter) 1.5 2. 2.5 3. FILTER FACE VELOCITY (m/s) SOUND LEVELS RADIATED FAN SPEED SWL db(a) 78 84 84 85 1 84 85 78 Sound Power Levels (SWL) Measured in decibels re 1 picowatt. 78 8 81 81 77 OCTAVE BAND FREQUENCY Hz 1 k SOUND POWER LEVELS (SWL) db 76 74 8 8 81 2 k 69 77 76 76 4 k 61 69 71 71 77 FAN SPEED SPL @ 3 m db(a) 62 68 66 66 67 1 68 69 73 Sound Pressure Levels (SPL) Measured in decibels re 2 µpa. OCTAVE BAND FREQUENCY Hz 1 k SOUND PRESSURE LEVELS (SPL) db 62 63 63 66 6 58 63 61 61 62 2 k 54 61 58 58 57 4 k 47 53 53 53 49 SUPPLY OUTLET INDOOR FLOW @3Pa Static 2 l/s 28 l/s 37 l/s 42 l/s 52 l/s SWL db(a) 83 83 83 87 Sound Power Levels (SWL) Test Conditions: BS 848 PT2 85. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. OCTAVE BAND FREQUENCY Hz 1 1 k 2 k 4 k SOUND POWER LEVELS (SWL) db 84 81 81 77 73 7 77 78 77 73 7 81 81 72 69 81 81 72 69 87 85 86 78 75

DIMENSIONS (mm) Fig. 1 Horizontal Supply & Return Air OPA SRKTBG1-P MIN. CLEARANCE B ACCESS PANEL 3 MIN. CLEARANCE A FLOW U V W Z MIN. CLEARANCE MIN. CLEARANCE Y X OPTIONAL WEATHER HOOD RETURN 6 SUPPLY Not to Scale A B C D E F G H J K L M N 22 5 1635 957 52 55 957 52 13 18 18 22 5 5 958 52 7 958 52 13 18 18 9 2 186 12 6 1 265 12 6 13 13 9 265 9 2 186 12 6 1 265 12 6 13 13 9 265 9 2 186 12 6 1 265 12 6 13 13 9 265 Note: The, 855, 96 models have four outdoor air fans. MIN. CLEARANCE FOR FILTER ACCESS FILTER ACCESS F E J K OPTIONAL WEATHER HOOD POINT LOADS (kg) U V W X Y Z 126 1 15 1 142 4 9 134 1 146 162 165 1 6 9 8 2 165 1 6 9 8 2 169 168 18 26 24 22 PROJECTION C D H L L MOUNTING CENTRES G DRAIN 1" BSP FEMALE M MOUNTING CENTRES N MIN. BENEATH HOOD Fig. 2 Downward Supply Air & Return Air OPA SRKTBG-P FLOW R S T R S T U V W X Y Z 957 13 13 52 76 52 55 55 957 U 958 13 13 52 745 52 7 7 958 12 13 13 6 75 6 1 1 12 V 12 13 13 6 75 6 1 1 12 12 13 13 6 75 6 1 1 12 Note: Above dimensions subject to confirmation FLOW Z Y W X Note: The, 855, 96 models have four outdoor air fans. Refer to Fig.1 for overall 6 SUPPLY & RETURN NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Certified data is available on request.

OPTIONS Dimensions (mm) Economiser P Q 735 335 735 335 MOTORISED FRESH DAMPER P 875 875 875 INDOOR SECTION ECONOMISER WEATHER HOOD Q FRESH INTAKE mm MINIMUM SUPPLY RETURN ROOF MOTORISED RETURN DAMPER Fresh Air Damper R S 435 785 435 785 ADJUSTABLE FRESH DAMPER R 43 81 43 81 43 81 FRESH WEATHER HOOD FRESH INTAKE S NOMENCLATURE O PA 4 6 5 R K T B G 1 - P e.g. Series Size Type O - Outdoor P - Packaged A - Air Cooled Divide by 1 to get approx. nominal Capacity in kilowatts R - Reverse cycle K - Refrigerant R41A T - Three phase power supply B - Twin compressor system (twin circuit) G - Digital compressor system (single) H - Horizontal discharge supply air fan U - Downward discharge supply air fan P - EC motor plug fan 1 - Std Horiz. S/A, Horiz. R/A 1 - Opp Hd Bott. S/A, Vert. R/A - Std Bott. S/A, Bott. R/A 32 - Opp Bott. S/A, Bott. R/A

SPECIFICATIONS Model (OPA SRKTBG-P version) : Nominal Cooling Capacity * 1 kw 46.7 56.1 71.6 85.1 96. Net Cooling Capacity kw 44.6 53.9 69.7 8.1 87.9 Heating Capacity * 2 kw 43.5 49.5 69.4 83.5 9. E.E.R. (Cooling) 2.96 3.5 3.3 3.4 2.8 Air Flow * 3 l/s 2 28 37 42 52 Power Source * 4 3 p h a s e 3 4 2-4 3 6 V a. c. 5 H z Indoor Fan Full Load Amps A/ph. 5.7 5.7 4 (x2) 4. (x2) 4. (x2) Running Amps (Total System) A/ph. / / 38 / 3 / 29 4 / 34 / 35 49 / 44 / 44 68 / 59 / 59 Recom'd External Protection A/ph. 5 8 12 Finish G r e y p o l y e s t e r p o w d e r c o a t Net Weight kg 774 84 1139 114 1148 Shipping Weight kg 869 949 1241 1242 124 Notes: * 1 Nominal Cooling Capacity at AS/NZS 38 conditions: Indoor Entering Air Temperature C D.B., C W.B.; Outdoor Entering Air Temperature 35 C D.B. Net Cooling Capacity at AS/NZS 38 includes an allowance for indoor fan motor heat loss. * 2 Heating Capacity at AS/NZS 38 conditions: Indoor Entering Air Temperature C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Power source includes voltage limits. NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Certified data is available on request. Available from temperzone limited Head Office, Auckland : 38 Tidal Rd, Mangere, N.Z. Private Bag 9333, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.biz temperzone australia pty ltd Head Office, Sydney : 14 Carnagie Place, Blacktown, NSW 48 PO Box 8, Seven Hills West, NSW 47, AUSTRALIA. Email sales@temperzone.com.au AUCKLAND SYDNEY Ph. -9-9 5 Ph. (2) 82-57 Fax -9-5 5637 Fax (2) 82-5711 WELLINGTON ADELAIDE Ph. -4-569 3262 Ph. (8) 834-67 Fax -4-566 6249 Fax (8) 834-18 CHRISTCHURCH SINGAPORE Ph. -3-3 36 Ph. SNG 6733 4292 Fax -3-3 5956 Fax SNG 65 718 MELBOURNE Ph. (3) 8769-76 Fax (3) 8769-761 BRISBANE Ph. (7) 338-8333 Fax (7) 338-833 NEWCASTLE Ph. (2) 4962-15 Fax (2) 4961-511 PERTH Ph. (8) 94-3844 Fax (8) 94-3855 TOWNSVILLE Ph. (7) 4774-356 Fax (7) 4774- HOBART Ph. (3) 62-66 Fax (3) 62-56 1/16 Pamphlet No. 412 temperzone limited 2