AHU Plus. DX Air Handling Units

Similar documents
SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Product Line Introduction. Karl Zhang Technical support engineer

Aquaflair TRAC-TRAF-TRAH

air systems Roomtop RTC-RTH 15 to 30 - L

CHAPTER 6 CONDENSING UNITS

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

PRODUCT GUIDE

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Integrated VarIable refrigerant flow ahu/pau (r410a)

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Blue Box Epsilon Echos +

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

recooler HP EQKR HEAT PUMP

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

50A KP 70A KP 90A KP 120A KP 150A KP 210A

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Modular Air-cooled Chillers


CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

VENTILATION. Effective heat exchange and fresh air ventilation

MODULAR CHILLER. R410a R22

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

HYDRONIC RESIDENTIAL

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

DC Inverter Smart VRF Products(R410A)

Increase your flexibility.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Air cooled industrial chillers

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Ducted inverter reverse cycle air conditioning

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

Galletti Water chillers and heat pumps catalogue

Air Cooled Scroll Chiller

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

VRV IV i-series heat pump

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

DVU-HP. Integrated Reversible Heat Pump System

NQ Series Portable Chillers

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Guide Specifications for InRow Direct Expansion

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

DAIKIN Air Handling Unit Modular

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Fresh Air Ventilation

Fresh Air Ventilation

Modular Air Cooled Scroll Chillers

1

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Advance Split

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

GHE Dehumidifiers for radiant cooling systems with heat recovery

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

CRIMSON & CRIMSON MAX

Compact design & easy maintenance

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Transcription:

AHU Plus DX Air Handling Units

AHU Plus DX DX Air Handling Units AHUPlusDX-TH: DX Air Hadling Unit with 100% Fresh Air AHUPlusDX -IGK: DX Air Hadling Unit with 100% Fresh Air and Heat Recovery AHUPlusDX-KH: DX Air Handling Unit with Mixing Section Section Construction Structure DX Air Handling Units are formed from required modular sections according to need. Frame of modular sections of our Air Handling Units are manufactured from natural aluminum anodized profile and plastic corner connection elements. Thickness of section panels are 42 mm, outer wall is electrostatic powder coated and inner wall is manufactured from galvanized sheet. AHUPlus DX Air Handling Units are indispensable at central ventilation and ambient air conditioning applications due to its high efficiency and energy saving provided by its 70 kg/m³ dense Rockwool filled panels, modern frame structure, statically and dynamically balanced, quiet and efficient plug fans. Our electrical motors are 380V-50Hz as standard. High efficient plug fans with EC motor can also be used on customer demand. All double-walled panels are mounted to the aluminum frame by special torch tipped M6 nuts. Double-walled rigid standard inspection doors have gapless rigid hinge, lock mechanism that will not create protrusion inside of the section and will not allow air leakage. There are 180 mm high, full-length chassis feet manufactured from 2 or 3 mm galvanized sheet. There are slots and holes at the corner of the chassis feet for handling it with crane or forklift. All of the holes required for automation (differential pressure switch, NTC temperature sensor, frost thermostat etc.) are opened on DX Air Handling Unit at production stage. Motor connection cables are taken to the junction box. On demand, the unit can be delivered as all automation placed, adjusted and collected at the panel. Section connection elements are manufactured from aluminum alloy material. They have high structural strength for connecting the section from outside. The total number of use between sections varies according to the size of the model. There is interior lighting and sight glass at fan and filter sections. Thanks to these accessories, sections can be checked without disabling the system. 40

DX Coil Features DX coil means cooling the air by loading the heat taken from the air passing through the evaporator to refrigerant with the help of compressor. To simply describe the system, a direct expansion-cooling coil is adapted to an Air Handling Unit and exterior VRF unit is connected to this coil to the extent it requires. While performing this operation, the refrigerant is evaporated at the source (AHU) where the heat transfer is made. In the transfer made by conventional cooling groups (chiller / hot water boiler), heat first transferred to water and then the heat transfer made inside the AHU via pipes and pumps. DX coil Air Handling Units condition the ambient air without the need for conventional cooling groups and even more with heat pumps, without need for hot water boilers. The main features sought at DX Air Handling Units can be listed as; operating efficiently while consuming low energy, air tightness, having construction that minimizes thermal bridges, not having vibration caused by dynamic forces. DX series Air Handling Units design and selection priorities are low operating cost and efficiency. We can list the following features in order to support these priorities; energy-saving fans, efficient heat recovery exchangers and coils, internal unit structure that provides optimized airflow. With our optional automation system, this efficiency can be taken to a higher level. 41

AHUPlusDX-TH DX Air Handling Unit with 100% Fresh Air AHUPlusDX -IGK DX Air Handling Unit with 100% Fresh Air and Heat Recovery 42

AHUPlusDX-KH DX Air Handling Unit with Mixing Section 43

Advantages of DX Air Handling Units - The most important advantage is that there is much less energy loss at fluid pipes, - With high COP values, it is an advantageous system in terms of operating and investment costs, it provides new, easy and quick solution for small and medium sized facilities with only one investment, - Heating and cooling is performed by single external VRF unit, reduces operating costs for heating and cooling, - Thanks to compressors with variable capacity (inverter technology) and fans used, it provides optimal control, so that it is controlled locally and it consumes only required amount of power, - Ability to give fast response to partial loads, - Saving wide area required for water cooling group and boiler, - Taking into regime in short time, - There is no freezing risk of water coil in this system unlike conventional systems, - Having much lower maintenance costs than conventional systems, - Low noise level, - In this system, there is less static load added to structure comparing the static load occurred by the water circulating in steel piping, pump and pipes in conventional chiller and hot water boiler systems, - There is no need for closed are due to its suitability to operate outdoor, - Have long lifetime considering conventional systems. For system to work safely and smoothly, all automation scenarios are compatible with Heat Pump Outdoor Unit and is a package solution with DX Air Handling Unit automation. Automation is designed to make DX Air Handling Unit and Heat Pump Outdoor Unit is synchronized. F7 Compact Filter F7 Kompakt Filtre Plate type Heat Recovery Plakalı Isı Eşanjörü Exhaust Plug Fan Egzoz Plug Fan MCC - DDC F4 Panel Filter F4 Panel Filtre on-off Damper with Motor on-off Motorlu Damper VRF External Unit VRF Dış Ünite VRF External Unit VRF Dış Ünite on-off Damper with Motor on-off Motorlu Damper Inside Blowing Plug Fan Mahal Üfleme Plug Fan Drift Eliminator Damla Tutucu DX Batarya DX Coil EXP Valve Electrical Heater Elektrikli Ön Isıtıcı F4 Panel Filter F4 Panel Filtre on-off Damper with Motor on-off Damper with Motor on-off Motorlu Damper on-off Motorlu Damper Copper Pipe Line Bakır Boru Tesisatı 44

Adventages AIRPLUS DX Air Handling Unit 1) Our DX Air Handling Units are manufactured in 1.800 and 25.000 m³/h range and 14 and 224 kw cooling capacity range. 2) High efficient rotary type or plate type heat exchanger provides energy conservation. 3) DX Air Handling Units have 42 mm Rockwool (50 kg/m³) insulated panel construction. 4) All following warning and safety signs and capacity information labels are placed on Air Handling Unit. (Warning signs are indelible and not affected by heat, cold and UV rays from sun.) 5) Plug fans are directly coupled with motor shaft and can be controlled with frequency inverter. EC motorized plug fans can be used on customer demand. (Efficiency of EC motorized plug fan is 92% and EC motorized plug fan application is recommended.) 6) Fan motor powers are selected considering dirty filter pressure loss. 7) There are built-in MCC (Magnetic Control Center) and DDC (Direct Digital Control) panels with relevant protection class on Air Handling Unit. 8) Besides MCC and DDC panels, there is EMERGENCY STOP BUTTON. 9) There is compact switch outside the device that cuts out the main electricity supply in case of emergency intervention. 10) EEV (Electronic Expansion Valve) and thermal sensors are mounted into DX Air Handling Unit during production and protected from outdoor weather conditions. 11) When the VRF unit that is connected to Air Handling Unit is defrosting, air handling unit s control system should switch to standby mode without alarming. 12) DX coils are selected to make cooling (evaporator) in summer and heating (condenser) in winter. 13) Sight glass and siphon of DX Air Handling Unit are provided. 14) Start-up (mechanical installation, necessary end connections, and setting up of parameters) of DX Air Handling Unit and VRF outdoor unit are made by AIRPLUS. Our company gives start-up and maintenance trainings. 15) Frequency inverter for AC motor is optional. Frequency inverters for motor control have high EMC filtering feature. 16) PLUG fans can control airflow rate by calculating differential pressure with built-in inverter. 17) Airflow rate over DX coil is kept stable by controller via frequency inverter. i.e., pressure differences (Filter pollution) 18) Optionally; controller with microprocessor on DDC panel is capable of communication with at least one communication protocol (i.e., ModBUS RTU) 19) Optionally; controller with microprocessor is programmed with software that is appropriate with operation logic of DX system. Critical working scenarios that are mutual alarm controls (Hot Start, Defrost Time, Defrost Cycle etc.) are included in the DX Air Handling Unit automation software. Thus, the maximum system protection measures are taken. 20) Optionally; all field sensors and control equipments are mounted to DX Air Handling Unit. (i.e., Damper motors, pressure differential sensors, thermal and humidity sensors, CO2 or CO/VOC sensors, 3-way valve bodies, modulating valve actuators, freeze protections etc.). 21) Optionally, DX Air Handling Unit section lighting is provided. 45

DX AHU Flow Chart SM PD DPT PD T T G4 G4 VRF Outdoor Unit SM SM PD DPT F7 MV Pre T DX MV Supply Fan On-Off Supply Fan Fault Status Supply Fan VSD Control Return Fan On-Off Return Fan Fault Status Return Fan VSD Control T AHU KIT AHU Kit On-Off DX Unit Cooling Mod On-Off DX Unit Heating Mod On-Off DX Unit Fault Status DX Unit Run Status DX Unit External Set Point Phase Failure Alarm Emergency Alarm Fire Alarm AHU General Fault Emergency Stop Reset Circurit Remote On-Off Alarm Acknowledge DI AI DO AO DI AI DO AO 46

Outdoor Units and Specifications MODEL AIRPLUS-VRF-140 AIRPLUS-VRF-160 Power Supply V/Ph/Hz 220-240 / 1 / 50 // 380-415 / 3 / 50 kw 14,0 15,5 RT 3,9 4,3 Cooling Power Input kw 3,95 4,52 EER kw/kw 3,54 3,43 kw 15,4 17,0 RT 4,30 4,80 Heating Power Input kw 4,16 4,77 COP kw/kw 3,70 3,56 Sound Pressure Level db(a) 57 57 Pipe Connections Liquid Pipe mm Ø 9,53 Ø 9,53 Gas Pipe mm Ø 15,9 Ø 19,1 Type DC DC Fan Motor Quantity 2 2 Air Flow Rate m 3 /h 6000 6000 Motor Output W 85*2 85*2 Quantity 1 1 kw 10 14 Rotary Compressor Crankcase Heater W 25 25 Oil Type FV50S FV50S Oil Charge ml 870 + 630 1400 + 250 Refrigerant Type R410A R410A Factory Charging kg 3,9 3,9 Design Pressure (High/Low) mpa 4,4/2,6 Net Dimensions (WxHxL) mm 900*1327*400 Packing Dimensions (WxHxL) mm 1030*1456*435 Net Weight kg 95 102 Gross Weight kg 106 113 Operation Temperature Range Cooling C -15-48 Heating C -15-27 47

Outdoor Units and Specifications MODEL AIRPLUS-VRF-252 AIRPLUS-VRF-280 AIRPLUS-VRF-335 Power Supply V/Ph/Hz 380-415 / 3 / 50 kw 25,2 28,0 33,5 RT 7,2 8,0 9,5 Cooling Power Input kw 5,88 7,20 9,05 EER kw/kw 4,29 3,89 3,70 kw 27,0 31,5 37,5 RT 7,70 9,00 10,70 Heating Power Input kw 6,15 7,61 8,99 COP kw/kw 4,39 4,14 4,17 Sound Pressure Level db(a) 57 57 59 Liquid Pipe mm Ø 9,53 Ø 9,53 Ø 12,7 Pipe Connections Gas Pipe mm Ø 22,2 Ø 22,2 Ø 25,4 Oil Balance Pipe mm Ø 6 Ø 6 Ø 6 Type DC DC DC + AC Quantity 1 1 1 + 1 Fan Motor Air Flow Rate m 3 /h 11500 11500 15100 Motor Output W 750 750 560 + 380 ESP Pa 0-20 (default) 0-20 (default) 0-20 (default) Pa 20-40 (customized) 20-40 (customized) 20-60 (customized) Quantity 1 1 1 kw 31,59 31,59 11,80 DC Inverter Compressor Crankcase Heater W 27,6*2 27,6*2 27,6*2 Oil Type FVC68D FVC68D FVC68D Oil Charge ml 500 500 500 Quantity - - 1 kw - - 17,1 Scroll Compressor Crankcase Heater W - - 27,6 Oil Type - - FVC68D Refrigerant Oil Charge ml - - 500 Type R410A R410A R410A Factory Charging kg 9 9 11 Design Pressure (High/Low) mpa 4,4/2,6 4,4/2,6 4,4/2,6 Net Dimensions (WxHxL) mm 960*1615*765 960*1615*765 1250*1615*765 Packing Dimensions (WxHxL) mm 1025*1790*830 1025*1790*830 1305*1790*820 Net Weight kg 198 198 268 Gross Weight kg 213 213 288 Operation Temperature Range Cooling C -5-48 Heating C -20-27 MODEL AIRPLUS-VRF-400 AIRPLUS-VRF-450 AIRPLUS-VRF-500 Power Supply V/Ph/Hz 380-415 / 3 / 50 kw 40,0 45,0 50,0 RT 11,4 12,8 14,2 Cooling Power Input kw 12,31 14,02 15,20 EER kw/kw 3,25 3,21 3,29 kw 45,0 50,0 56,0 RT 12,80 14,20 15,90 Heating Power Input kw 11,19 12,79 14,25 COP kw/kw 4,02 3,91 3,93 Sound Pressure Level db(a) 60 60 61 Pipe Connections Fan Motor DC Inverter Compressor Scroll Compressor Refrigerant Liquid Pipe mm Ø 15,9 Ø 15,9 Ø 19,1 Gas Pipe mm Ø 31,8 Ø 31,8 Ø 31,8 Oil Balance Pipe mm Ø 6 Ø 6 Ø 6 Type DC + AC DC + AC DC + AC Quantity 1 + 1 1 + 1 1 + 1 Air Flow Rate m 3 /h 15100 15100 15200 Motor Output W 560 + 380 560 + 380 560 + 380 ESP Pa 0-20 (default) 0-20 (default) 0-20 (default) Pa 20-40 (customized) 20-40 (customized) 20-60 (customized) Quantity 1 1 1 kw 31,59 31,59 11,80 Crankcase Heater W 27,6*2 27,6*2 27,6*2 Oil Type FVC68D FVC68D FVC68D Oil Charge ml 500 500 500 Quantity 1 1 1 kw 13,39 13,39 20,9 Crankcase Heater W 27,6 27,6 27,6 Oil Type FVC68D FVC68D FVC68D Oil Charge ml 500 500 500 Type R410A R410A R410A Factory Charging kg 13 13 16 Design Pressure (High/Low) mpa 4,4/2,6 4,4/2,6 4,4/2,6 Net Dimensions (WxHxL) mm 1250*1615*765 1250*1615*765 1250*1615*765 Packing Dimensions (WxHxL) mm 1305*1790*820 1305*1790*820 1305*1790*820 Net Weight kg 280 280 300 Gross Weight kg 300 300 320 Operation Temperature Range Cooling C -5-48 Heating C -20-27 48

Outdoor Units and Specifications MODEL AIRPLUS-VRF-I-200 AIRPLUS-VRF-I-224 AIRPLUS-VRF-I-260 Power Supply V/Ph/Hz 380-415 / 3 / 50 kw 20,0 22,4 26,0 RT 5,7 6,4 7,4 Cooling Power Input kw 6,10 6,80 7,60 EER kw/kw 3,28 3,29 3,42 kw 22,0 24,5 28,5 RT 6,30 7,00 8,10 Heating Power Input kw 6,10 5,90 6,80 COP kw/kw 3,61 4,15 4,19 Sound Pressure Level db(a) 59 59 60 Pipe Connections Liquid Pipe mm Ø 9,53 Ø 9,53 Ø 9,53 Gas Pipe mm Ø 19,1 Ø 19,1 Ø 22,2 Type DC DC DC Fan Motor Quantity 2 2 2 Air Flow Rate m 3 /h 11000 10500 10500 Motor Output W 210 + 160 200 + 150 200 + 150 Quantity 1 1 1 kw 13,98 16,86 16,86 Scroll Compressor Crankcase Heater W 25 25 25 Oil Type FV50S FV50S FV50S Oil Charge ml 1400 1700 1700 Refrigerant Type R410A R410A R410A Factory Feed kg 4,8 6,2 6,2 Design Pressure (High/Low) mpa 4,4/2,6 Net Dimensions (WxHxL) mm 1120*1558*400 Packing Dimensions (WxHxL) mm 1270*1720*565 Net Weight kg 137 146,5 147 Gross Weight kg 153 162,5 163 Operation Temperature Cooling C -15-48 Range Heating C -15-27 MODEL AIRPLUS-VRF-I-560 AIRPLUS-VRF-I-615 AIRPLUS-VRF-I-670 Power Supply V/Ph/Hz 380-415 / 3 / 50 kw 56,0 61,5 67,0 RT 15,9 17,5 19,0 Cooling Power Input kw 17,00 18,80 20,80 EER kw/kw 3,30 3,27 3,22 kw 63,0 69,0 75,0 RT 17,90 19,60 21,30 Heating Power Input kw 16,00 17,90 19,80 COP kw/kw 3,94 3,86 3,79 Sound Pressure Level db(a) 62 63 63 Pipe Connections Liquid Pipe mm Ø 19,1 Ø 19,1 Ø 19,1 Gas Pipe mm Ø 31,8 Ø 31,8 Ø 31,8 Type DC + AC DC + AC DC + AC Quantity 2 2 4 Fan Motor Air Flow Rate m 3 /h 20000 23000 23000 Motor Output W 340 + 450 625 + 450 625 + 450 ESP Pa 0-20 (default) Pa 20-40 (customized) Quantity 1 1 1 kw 31,59 31,59 31,59 DC Inverter Compressor Crankcase Heater W 33*2 33*2 33*2 Oil Type FVC68D FVC68D FVC68D Oil Charge ml 500 500 500 Quantity 2 2 2 kw 15,39*2 17,1*2 20,9*2 Rotary Compressor Crankcase Heater W 27,6 27,6 27,6 Oil Type FVC68D FVC68D FVC68D Oil Charge ml 500*2 500*2 1100*2 Refrigerant Type R410A R410A R410A Factory Feed kg 17 18,5 18,5 Design Pressure (High/Low) mpa 4,4/2,6 Net Dimensions (WxHxL) mm 1390*1615*765 1585*1615*765 1585*1615*765 Packing Dimensions (WxHxL) mm 1455*1790*830 1650*1810*840 1650*1810*840 Net Weight kg 360 385 390 Gross Weight kg 375 400 405 Operation Temperature Cooling C -5-48 Range Heating C -20-27 49