Compact ventilation units with heat recovery and EC fans 5th generation

Similar documents
DOMESTIC LINE DUPLEX EASY

COMPACT VENTILATION UNITS DUPLEX R5

COMMERCIAL LINE DUPLEX ROTO

COMMERCIAL LINE. DUPLEX Flexi

Automatic control system. for kitchen facilities

COMMERCIAL LINE. DUPLEX MultiEco

COMPACT VENTILATION UNITS DUPLEX EC5

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

VENTILATION WITH HEAT RECOVERY

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

SKV, TPV Ventilation and extraction ceilings for industrial kitchens

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

KOMFORT EC DB Suspended heat recovery air handling units

VEX100 series Air handling units with cross-flow heat exchanger

Healthy, comfortable and energy-efficient ventilation

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Description... 2 Construction... 2 Size and weight... 3 Installation and placement... 4

Compact. Efficient. TROX.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

AIR HANDLING UNITS MANDÍK

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

Instructions for the fan motor control system with integrated wiring terminals SILVER C

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

Comfort Air Curtains with in-built dynamic advertising

Primo Hotel. General. Indoor climate units for hotel rooms

Energy recovery unit. Projection documents

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

VERSO Air Handling Units

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

Design vertical air curtain. Tubex, Tubex XL.

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Units for suspended cei lings

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Units for suspended ceilings

(INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

DOMEKT. Residential ventilation units

air handling units AT THE LEADING EDGE OF AIR FLOW

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

2013 innovation. Room-by-room demand controlled heat recovery ventilation

Dew point set DS 400

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

HART XL High Sensitivity Smoke Detection

Feature Summary. I. System

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

VERSO Air Handling Units

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

Flexible & Innovative. Cooling Solutions

VENTILATION UNITS. local ventilation units with heat recovery KORASMART KORASMART KORASMART KORASMART KORAVENT KORAVENT KORAVENT KORAVENT

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Double Skin Air Handling Units

Healthy, comfortable and energy-efficient ventilation

Breathe Fresh Air at Home

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

HART XL High Sensitivity Smoke Detection

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Hi-Pres Cooling Products Catalogue. Product Catalogue

Measuring Recording Online Monitoring Regulation Alarming

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

VEX350 / VEX360 Air handling units with counter flow heat exchangers

Modular Air Cooled Scroll Chillers

PRESENTATION SUMMARY

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

CONTENT: VEX308 Decentralised ventilation VEX308

Product Line Introduction. Karl Zhang Technical support engineer

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

Energy-efficient heat source provides comfort in large rooms

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Heat recovery unit. Installation Manual

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

VENTILATION. Effective heat exchange and fresh air ventilation

Transcription:

DUPLEX EC5, ECV5 Compact ventilation units with heat recovery and EC fans 5th generation CP TOUC CONTROLLER touchscreen display low voltage cabling CP Touch controller setting the modes, programming a unit operation Internet access exhau air EC fan enhanced thermal and acouic insulation CP basic digital built-in module RD5 the 5th generation control module with built-in web-server supply air EC fan circular port Residential ventilation and heating chapter. issue 4/16 DUPLEX EC5.RD5 UNIT circular port circular port filter class G4 / F7 New generation counter flow heat recovery exchanger with efficiency up to 95 % by-pass damper with servo drive circular port filter class G4 / F7 R E I D E N T I A L V E N T I L A T I O N & E A T I N G ATREA s.r.o., Čs. armády 466 5 Jablonec n. Nisou Czech Republic w w w. a t r e a. e u Tel.: +4 48 68 111 Fax: +4 48 68 11 E-mail: atrea@atrea.eu

ATREA VENTILATION YTEM A T R E A V E N T I L A T I O N Y T E M yem description The ventilation syem provides controlled equal-pressure ventilation with heat recovery for the houses and high-rise residential buildings, together with possible reheating of the supply air, pre-cooling in summer and the effective use of all internal and external energy gains. Properly designed ventilation syem provides fresh filtered air to each room and kitchen and ensures exhau of used air from bathrooms, toilets and kitchens. The company ATREA offers this syem as a complete conruction set, consiing of the following main components: ventilation units with heat recovery series DUPLEX EC5 and ECV5 complete measuring and regulation syem with the option to control other parts of the syem (e.g. a zone butterfly valve, an earth heat exchanger etc.) integrated syem of the ATREA air ducts and fittings suitable for all desired options Using in low-energy and passive houses In the low-energy houses, the ventilation syem supplements a basic heating syem (e.g. central heating units, floor heating etc.). In the passive houses, built in the Czech and lovak Republics, in addition to reheating of the supply air after heat recovery to the building, we also recommend the implementation of the additional heating syem for compliance with the optimum relative humidity in the interior, thus avoiding excessive ventilation during heating. They can also be used in combination with a fireplace insert or other bivalent heat source. With higher demand on cooling or heating by the VAC syem only, it is recommended to choose the ventilation units with air circulation, e.g. the dual-zone units series DUPLEX R5. Ventilation performance Ventilation syem design Based on the long-term measurements and experience with the implementation of the ventilation syems in the residential buildings, the ATREA company recommends dimensioning of the ventilation performance according to CN EN 1551 Class see the marked part of the table below. Legislative requirements The ventilation units DUPLEX EC5 and ECV5 carry energy labels in accordance with EU Regulation no. 15/14 and 154/14.. Ventilation syem advantages Ensure permanent air changes necessary for hygienic reasons with a possibility of one-off increases (e.g. by an external signal from toilets, bathrooms, kitchens or other inputs on the basis of users immediate requirements) avings on ventilation cos by up to 9 % thanks to highly efficient heat recovery exchangers Elimination of mold formation Elimination of thermal discomfort due to air supply with temperature differences kept to a minimum (again as a result of heat recovery with high efficiency) Utilisation of all internal and external thermal gains from the flat space for the heat recovery pre-heating of ventilation air The supply of perfectly filtered air (through Class G4 or F7 filters) significantly reduces the occurrence of allergies and respiratory diseases When the unit is set to full performance (via a by-pass), cooling is possible in summer, particularly through the supply of night filtered air A full-range modular syem allows for easy or even DIY inallation tandard regulation Ventilation intensity in Ventilation Volume per Kitchens Bathrooms Toilets unoccupied rooms intensity person -1-1 (m /h) (m /h) (m /h) (h ) (h ) (m /h) CN EN 15665 Z1 Minimum value, 15 1 5 5, Recommended value,5 5 15 9 5 1 Class,7 6 1 7 5 CN EN 1551 nd Class,1,,6 5 7 54 6 rd Class,5 15 5 6 5 CN 7 54,1,,6 15 5 References to other regulations More documentation for designing a ventilation syem Mounting details Catalogue of components www.atrea.eu CD election software E A T R E C O V E R Y W A T I I T? Chilled exhau air out + C eated fresh air out + C eat recovery efficiency 9 % Warm exhau air in + C Fresh cool air in C eat recovery principle eat transfer occurs through the separating walls of a heat exchanger in winter warmer exhau air preheats colder supply air. The same principle is applied also in summer for cool recovery. In winter time humidity condensates in exhau air. This condensate increases heat recovery efficiency through improved heat transfer and is continuously drained into a sewer syem. ignificance of heat recovery An energy-optimised heat recovery exchanger reaches a highly economical ratio between power consumption (to run fans), air performance and heat recovery. The fan input vs. heat recovery gain ratio during ventilation reaches an energy efficiency of 4, i.e. from 1 W of power used to run a DUPLEX EC5 up to 4 W is recovered from exhau air. Effective ratio 1 : 4

DUPLEX EC5, ECV5 D U P L E X E C 5 / E C V 5 U N I T D E C R I P T I O N Intention The new 5th generation heat recovery units DUPLEX are delivered in two basic lines: DUPLEX EC5 for the inallation under the ceiling and DUPLEX ECV5 in the vertical design. The units are designed for the comfort ventilation of all types of residential and public buildings, are particularly suitable for the low-energy and passive houses and the apartments in the residential buildings with the decentralized ventilation syem. Basic description In the unit housing, made with mineral insulation with the - -1 thickness of mm (U =.81 Wm K ) with the thermal bridges suppression and the reaction to fire class A/A1, a swirling counterflow plaic heat recovery exchanger (efficiency up to 95 %), two ventilators of free impeller type with the electronic EC control and the possibility to supplement regulation for the control of the conant air flow, supply and exhau air filters G4 before entering the recovery heat exchanger, an automatic butterfly valve of the by-pass, a control module and a connection terminal plate are built in. For the ceiling units EC5, condensate outlets in the doors are prepared for both operating positions of the units. Connection nozzles are round, used for connecting flexible or fixed piping with the thermal bridges suppression. Access to the unit is possible through the fully openable hinged door via the locking latches. Units advantages highe energy efficiency class very low height allowing inallation in the ceiling andard built-in fans with free impeller type EC are characterized by very low power consumption and excellent speed regulation higher outputs of the units enable occasional intensive air exhau or summer ventilation recovery efficiency up to 95 % due to the new generation recuperation exchangers excellent thermal insulation parameters of the unit housing with the thermal bridges suppression high sound attenuation of the unit housing due to the high density mineral insulation built-in by-pass is a andard part of the unit and needs no additional space; in addition, due to its conruction, it ensures 1 % by-pass in the by-pass mode without mutual thermal transfer andardly offered two types of regulation meet all the requirements of the unit:.cp easier and cheaper basic digital control syem of the units.rd5 a new digital control syem, optional for inallation, enables connection of a wide range of sensors and other inputs, control of the shut-off and zone butterfly valves of the diribution syem, control of the heaters or the heating syem of the house etc. plus it is andardly equipped with a built-in web server for the possible control via the Internet possibility of inallation of the built-in electrical or external electrical or hot water preheaters/air reheaters possible mirror changes in the EC5 units to the right/left position only by setting the regulation parameter (.RD5 units) or by simple reconnection (.CP units) I N T A L L I N G T E U N I T DUPLEX EC5 under-ceiling type New DUPLEX EC5 units have a very flat design that allows inalling them into even very low suspended ceilings. The minimum requirements for suspended ceiling void heights are in the table. A plaerboard lid is fitted below the unit; in bathrooms the lid mu be airtight and the entire suspended ceiling eam tight. DUPLEX ECV5 vertical type New vertical units DUPLEX 8 ECV5 and 8 ECV5 can be inalled in narrow spaces due to their width, e.g. wardrobes with minimum internal width of 65 mm. min. 5 min. 1 DUPLEX EC5 1 X unit unit height min. height of the ceiling cavity X 17 EC5 9 5 7 EC5 9 5 57 EC5 65 4 6 incl. the door inner 65 49 617 min 15 L 1 inlet into sewer min 15 min 15 L 1 inlet into sewer min 15 Condensate drainage During heat recovery heat regaining moiure is condensated during the cooling of exhau air. Water condensates on the walls of the heat recovery exchanger, further increasing heat recovery efficiency. Condensate runs out of the heat recovery exchanger in the direction of air being extracted and is drained from the DUPLEX unit into a sewer syem. For correct functioning and drainage the unit mu be separated from the sewer syem using a siphon of a sufficient height, the recommended minimum being 15 mm. mall condensation drain pumps may be used.

TECNICAL DATA DUPLEX EC5 P E R F O R M A N C E P A R A M E T E R E C 5 T E C N I C A L D A T A E C 5 D U P L E X 1 7 E C 5 D U P L E X 7 E C 5 5 4 1 7 6 5 4 1 5 1 15 5 1 15 5 5 4 D U P L E X 5 7 E C 5 9 8 7 6 5 4 W 65 W 79 W 167 W 1 W Legend: pressure reserve with the filter G4* Qref reference flow Qmax maximum flow * max. pressure reserve curve is indicated * electrical power consumption of the entire unit (both fans including the regulation) is indicated DUPLEX 17 EC5 7 EC5 57 EC5 pecific energy class ) Max. airflow rate m /h 175 7 57 ) ound power level L WA db 7 8 4 Max. heat recovery efficiency % 94 95 94 eight mm 9 9 7 Width mm 655 9 9 Length (without ports) L mm 84 1 116 1 9 Diameter of connecting ports mm 16 5 Weight kg 9 58 7 By-pass Yes Voltage V / 5 z upply air filter class G4 (alter. F7) Condensate drain mm x 16 (depending on position) All types of the regulation built-in in the unit andardly include a minimum of two inputs for connecting electrical signals arising as a result of human manipulation with lighting, or for connecting other devices that automatically regulate the unit output. These inputs mu always be connected, or other types of sensors (e.g. CO, VOC, r and the like) mu be connected inead. The maximum flow rate is set at the pressure disposition of 1 Pa ) The ated value refers to the reference flow rate i.e. 7 % of the maximum flow ) rate, and to the pressure disposition of 5 Pa O U N D P A R A M E T E R O F E C 5 U N I T For the sound power and pressure levels of a specific DUPLEX EC5 or ECV5 unit and an operating point selected see ATREA's selection software. D I M E N I O N A L D I A G R A M E C 5 U NDER CEILING T YPE 1 17 W 6 L 6 1 4 5 6 For detailed information and D or D blocks in DXF use our selection software. A K i E C 5 V E R I O N U NDER CEILING T YPE i K e B e eat recovery efficiency (%) E C 5 R E C O V E R Y E F F I C I E N C Y 1 95 9 85 8 75 Possible condensation region M i = Me 7 1 4 5 6 7 17 EC5 7 EC5 57 EC5 L E G E N D e Fresh outdoor air inlet 1 e Fresh filtered air outlet i Exhau air inlet 1 i Exhau air outlet Control module e i DUPLEX EC5 units are delivered in a universal position, i.e. the choice between the "right" and "left" position, as shown above, is performed by changing the regulation syem parameters for the.rd5 regulation type, and by relocating the operating sensor, reconnecting the fans and relocating the by-pass thermoat for the.cp type.

TECNICAL DATA DUPLEX ECV5 T E C N I C A L D A T A E C V 5 DUPLEX 8 ECV5 8 ECV5 58 ECV5 pecific energy class ) Max. airflow rate m /h 85 65 565 ) ound power level L WA db 5 6 4 Max. heat recovery efficiency % 94 95 94 eight (without ports) V mm 1 1 1 8 Width mm 617 617 98 Depth mm 49 49 59 Diameter of connecting ports mm 4) 16 16 Weight kg 59 59 75 By-pass Yes Voltage V / 5 z upply air filter class G4 (alter. F7) Condensate drain mm 1x 16 All types of the regulation built-in in the unit andardly include a minimum of two inputs for connecting electrical signals arising as a result of human manipulation with lighting, or for connecting other devices that automatically regulate the unit output. These inputs mu always be connected, or other types of sensors (e.g. CO, VOC, r and the like) mu be connected inead. ) The maximum flow rate is set at the pressure disposition of 1 Pa ) The ated value refers to the reference flow rate i.e. 7 % of the maximum flow rate, and to the pressure disposition of 5 Pa D I M E N I O N A L D I A G R A M O F E C V 5 U N I T K E C V 5 V E R I O N V E R TICAL T YPE V 6 DUPLEX 8 ECV5 DUPLEX 8 ECV5 e i DUPLEX 58 ECV5 For detailed information and D or D blocks in DXF use our selection software. e e e i i i P E R F O R M A N C E P A R A M E T E R E C V 5 D U P L E X 8 E C V 5 D U P L E X 8 E C V 5 6 5 4 1 49 W 5 1 15 5 8 7 6 5 4 1 5 1 15 5 5 4 D U P L E X 5 8 E C V 5 9 8 7 6 5 4 1 7 W 11 W 1 4 5 6 Legend: pressure reserve with the filter G4* Qref reference flow Qmax maximum flow * max. pressure reserve curve is indicated * electrical power consumption of the entire unit (both fans including the control syem) is indicated E A T R E C O V E R Y E F F I C I E N C Y E C V 5 118 W 19 W 45 W L E G E N D e Fresh outdoor air inlet 1 e Fresh filtered air outlet i Exhau air inlet 1 i Exhau air outlet Control module K eat recovery efficiency (%) 1 95 9 85 8 75 Possible condensation region M i = Me 7 1 4 5 6 7 8 ECV5 8 ECV5 58 ECV5

CONTROL YTEM C O N T R O L Y T E M G E N E R A L O V E R V I E W External inputs Control of external elements Conant control syem Performance auto. air flow type setting range by-pass webserver Ground Delay and Immediate Input hut-off el. reheater VAC hot-water water control coupled run-down art 1 V dampers / preheater programming heater cooler exchanger EC5.CP + CPA l 1 1 % l 1+n 1 l l EC5.CP + CPB EC5.RD5 EC5.RD5.CF zone kitchen dampers damper 1 1 % l l 1 l l l l l l l l l l heating syem C P C O N T R O L B A I C D I G I T A L C O N T R O L M O D U L E Convenient regulation provides intuitive control and a wide range of cuomizable parameters. The syem allows connecting of an external input to improve the ventilation performance (signals from the rooms, for example, WC, bathroom, kitchen), input 1 V for the performance control according to the air quality sensors (CO, R). It is also possible to connect the integrated or external electrical preheater (to protect the recovery heat exchanger again Connection to main power V, 5 z CYKY 5x1,5 mm V Common power supply for the unit and the heater /inc. the preheater/ Unit protection FA1 1 A, char. C eater protection FA 1 A, char. B + tripping coil V, 5 z CPA CPB Required connections x external input from the house space connection with the controller YKFY 5xx,5 (max. 5 m) freezing) and the air reheater (to achieve the required supply air temperature). tandard regulation further provides the option to control the shut-off valves at the supply and exhau. The uniqueness of the syem is underlined by a wall digital touchscreen CPA controller. As an alternative of the touch controller, a simple mechanical CPB controller can be used. DUPLEX EC5.CP ECV5.CP Optional connections Optional connections R D 5 C O N T R O L A D V A N C E D D I G I T A L C O N T R O L Y T E M Basic description Digital control module type RD5 is the mo advanced method for the unit control. It provides all the basic functions and also includes a number of other inputs and outputs for connecting with optional sensors (e.g. CO sensors, relative humidity sensors), signals from the rooms (WC, bathroom, kitchen), the heating syems including the shut-off valves or the shut-off butterfly valves in the diribution syem. In addition, it includes the web-server and the Internet access. The units with the digital module can be controlled: a) via the controller series CP Touch touch colour display b) via the controller series CP 1 RT mechanical controller c) without the controller, only by the voltage from 1 V (e.g. via the CO sensor or other superior syem). Control through the external signals and other automatic ventilation functions are maintained. d) through the intelligent built-in web-server allows controlling and set-up via a web application, and is possible also for the options a), b) and c). e) through a external control syem via a andard interface Modbus TCP. Functions The control module provides all the basic functions of the unit: programming of the various ventilation outputs during the day and the week smooth power control of both fans, with conant power function (i.e. automatic change of power to achieve the set flow rate directly in m /h) for the CF version. automatic control of the by-pass butterfly valve (supply air by-pass) according to the outside air temperature the electric heater control (optional accessory) at a conant supply air temperature in the range of 15 to 5 C (max. achievable temperature depends on the performance of the inalled electric heater) or the control of the air temperature according to a programmed temperature difference again the required room temperature (may be automatically changed according to the settings during the day) switching the hot water heater (optional accessory), setting the supply air temperature by controlling a mixing node point or a hot water throttle valve 1 V, including the fro protection of the hot water heater (via the sensor downream the heater AD switching the water cooler (optional accessory), setting the supply air temperature by control of the mixing node point or the hot water throttle valve by the signal 1 V, the sensor mu be fitted to the pipe downream the cooler (via the sensor AD the recovery exchanger fro protection Required connections Connection to main power V, 5 z CYKY 5x1,5 mm V Common power supply for the unit and the heater /inc. the preheater/ Unit protection FA1 1 A, char. C eater protection FA 1 A, char. B + tripping coil V, 5 z x external input from the house space DUPLEX EC5.RD5 ECV5.RD5 switching to the selected output when closing through the external signal (e.g. from WC, bathroom, kitchen) with optional art and rundown Control of the shut-off butterfly valve at the inlet and the exhau, and also two zone ventilation butterfly valves and one exhau butterfly valve from the kitchen (the dampers are not part of the unit) 4 V DC optional automatic operation controlled by the sensors CO concentration, relative humidity or VOC (optional accessory) x input 1 V or the switching contacts according to the settings, the unit allows periodic ventilation mode the unit is at re and switches ventilation at set intervals automatic setting of the ventilation length depending on the number of persons and the building airtightness at the periodic ventilation or when running the intermittent ventilation Controllers CP Touch: is intended for setting the basic ventilation modes and displaying the atus of the ventilation unit including the indication of fault conditions. It allows the user access to common functions or programming of the operating modes that can be operated in the manual mode or the automatic mode according to the weekly program settings. The controller also allows setting a temporary party / holiday mode. Part of the controller is an integrated room thermoat with a weekly heating/cooling program, which can also control the simple heating syem by using the functions of the control module. All values can be set on the well ructured graphical touch screen. CP 1 RT: allows mechanical setting of the ventilation output and the supply air temperature, turning the device off. Due to the built-in diode, indicates the equipment failure flashing red, the device operation shining green. Other programmable features are accessible only via the web interface. CP Touch CP 1 RT Optional connections Ethernet connector RJ45 x,5 mm (screened) e.g. YKFY xx,5 Optional connections connection with the controller (not part of the delivery) Modbus TCP Internet CP 1 RT CP Touch

OPTIONAL ACCEORIE B U I L T - I N E L E C T R I C P R E E A T E R / R E E A T E R E D O P T C designed for the integration into the unit, inallation at a predetermined place inside the unit incl. the inallation frame according to the output and the indication, the heater is designed for the supply air preheating or reheating: EDO5 heaters/preheater for the unit EC5 EDO5.V heaters/preheater for the units ECV5 EDO5.RD5 heaters/preheater for the units with the RD5 control syem EDO5.CP heaters/preheater for the units with the CP control syem operating temperature control is ensured by the unit control syem the element is prepared for the easy inallation into the unit incl. the cabling the heater is equipped with a non-interfering switch element R (for the RD5 regulation types EDO5-RD5) or a switching relay (for the CP regulation types EDO5-CP) max. temperature of the outlet air is dependent on the EDO5 output (e.g. input power 1 W increases the temperature of the supply air in the amount of 1 m /h by max. C EDO5 integration directly into the unit does not reduce the unit pressure reserve it is equipped with two safety reverse acting thermoats 45 and 6 C DUPLEX unit 17 EC5 / 8 ECV5 7 EC5 / 8 ECV5 57 EC5 / 58 ECV5 Preheater EDO5 65 W 99 W 1 W Reheater EDO5 5 W/ 6 W 5 W / 6 W 5 W / 6 W D U C T E L E C T R I C P R E E A T E R / R E E A T E R E P O V D Permitted terminal board positions Permitted flow direction D D Type EPO-V heaters can be combined only with the units with the RD5 control syem used for the fresh air preheating, inalling in the pipeline at the fresh air inlet used for the supply air reheating, inalling in the pipeline downream the unit (requires inallation of the AD 1 sensor in the pipeline downream the heater) the housing is made of galvanized sheet metal the housing includes the terminal plate and the internal inallation IP4 protection, inallation only to normal environments Power input (kw) Voltage (V) Min. air flowrate (m /h) D Recommended for DUPLEX EPO-V 15/,9,9 45* 15 17 EC5, 8 ECV5 EPO-V 16/1,5 1,5 11* 16 17 EC5, 8 ECV5, 8 ECV5 EPO-V /,1,1 17* 7 EC5, 58 ECV5 EPO-V 5/,, 4 6* 5 57 EC5, 58 ECV5 * If requeed lower flowrate than shown here, please use the built-in EDO integrated heaters. it is equipped with two safety thermoats, a reverse acting (6 C) and a safety irreversible thermoat (switched off at 1 C) the heater is equipped with a non-interfering switch element R the safety thermoat reset button is located on the housing, during the assembly the heater mu be located with regard to access and mu not be fitted with a cover downward minimum airflow in the heater is 1.5 m/s Δp (Pa) PREURE LO 1 EPO-V 15 EPO-V 16 EPO-V EPO-V 5 1 4 5 Air volume (m /h) O T W A T E R A I R E A T E R T P O E C T V Used to reheat air, to be inalled in ducts (can be used only with digital control syem) AD 1 sensor required (to be inalled in the duct downream the heater) Painted metal sheet housing Aluminium lamellas on copper tubes Maximum operating pressur bar Maximum operating temperature 7 C As andard the heater includes electric choke valve with 4 V DC power supply and 1 V control Type L D B D B Air flow rate (m /h) Water flow rate (l/h) Pressure loss (kpa) eating power* (kw) 1,1, 15 4,,5 6,,8 8,6 1, 4 1,9 1,9 5 1 1,,5 * The table applies for heating water temperature 55 / 5 C, supply air after heat recovery 15 C, exhau air min. C. Parameters for different conditions can be found using the ATREA selection software. L ( ) Recommended for DUPLEX TPO 15 EC TV 15 418 48 5 1/ 8 ECV5 TPO 16 EC TV 16 418 48 5 1/ 17 EC5, 8 ECV5 TPO EC TV 418 48 5 1/ 7 EC5, 58 ECV5 TPO 5 EC TV 5 418 48 5 1/ 57 EC5, 58 ECV5 Δp (Pa) PREURE LO 5 4 1 1 4 5 Air volume (m /h) TPO 15 TPO 16 TPO TPO 5

MODULAR ATREA VAC YTEM D U P L E X E C 5, E C V 5 U N I T DUPLEX 17 EC5.RD5 DUPLEX 17 EC5.RD5.CF DUPLEX 17 EC5.CP DUPLEX 7 EC5.RD5 DUPLEX 7 EC5.RD5.CF DUPLEX 7 EC5.CP DUPLEX 57 EC5.RD5 DUPLEX 57 EC5.RD5.CF DUPLEX 57 EC5.CP DUPLEX 8 ECV5.RD5 DUPLEX 8 ECV5.RD5.CF DUPLEX 8 ECV5.CP DUPLEX 8 ECV5.RD5 DUPLEX 8 ECV5.RD5.CF DUPLEX 8 ECV5.CP DUPLEX 58 ECV5.RD5 DUPLEX 58 ECV5.RD5.CF DUPLEX 58 ECV5.CP P A R E F I L T E R C A E T T E FK 17 EC5 G4 FK 17 EC5 F7 FK 7 EC5 G4 FK 7 EC5 F7 FK 57 EC5 G4 FK 57 EC5 F7 FK 8, 8 ECV5 G4 FK 8, 8 ECV5 F7 FK 58 ECV5 G4 FK 58 ECV5 F7 pare air filters are delivered in package of 1 pc. Ord. No. A1651 Ord. No. A165 Ord. No. A165 Ord. No. A16511 Ord. No. A1651 Ord. No. A1651 Ord. No. A1651 Ord. No. A165 Ord. No. A165 Ord. No. A1651 Ord. No. A165 Ord. No. A165 Ord. No. A16514 Ord. No. A1654 Ord. No. A1654 Ord. No. A16516 Ord. No. A1656 Ord. No. A1655 Ord. No. A16965 Ord. No. A16968 Ord. No. A16966 Ord. No. A16969 Ord. No. A16967 Ord. No. A1697 Ord. No. A16971 Ord. No. A1697 Ord. No. A1697 Ord. No. A16974 C O N T R O L L E R CP Touch controller touchscreen 4 colour versions (white, ivory, grey and anthracite) CP 1 RT Controller white colour CPA Controller exchangeable cover touchscreen CPB Controller white colour RD4-IO expansion RD5 control module RD-BACnet/KNX expansion RD5 control module O P T I O N A L A C C E O R I E A I R E AT E R EPO-V 15/,9 EPO-V 16/1,5 EPO-V /,1 EPO-V 5/, EPO-V 5/, TPO 15 EC TV TPO 16 EC TV TPO EC TV TPO 5 EC TV AD 1 AD 1 sensor is necessary for the heaters EPO-V or TPO EC TV O P T I O N A L ACCEORIE AIR REEAT E R EDO5 RD5 EDO5.V RD5 EDO5 CP EDO5.V CP Ord. No. A171 Ord. No. A1711 Ord. No. A171 Ord. No. A171 Ord. No. A1714 Ord. No. A17141 Ord. No. A1441 colour covers see price li Ord. No. A14411 Ord. No. A1785 Ord. No. A1788 Ord. No. A1511 Ord. No. A151 Ord. No. A151 Ord. No. A15116 Ord. No. A1515 Ord. No. A161 Ord. No. A161 Ord. No. A1614 Ord. No. A1615 Ord. No. A14 Performance variants, see price li P A R E F I L T E R C L O T FT 17 EC5 G4 FT 17 EC5 F7 FT 7 EC5 G4 FT 7 EC5 F7 FT 57 EC5 G4 FT 57 EC5 F7 FT 8, 8 ECV5 G4 FT 8, 8 ECV5 F7 FT 58 ECV5 G4 FT 58 ECV5 F7 Ord. No. A16975 Ord. No. A16978 Ord. No. A16976 Ord. No. A16979 Ord. No. A16977 Ord. No. A1698 Ord. No. A16981 Ord. No. A1698 Ord. No. A1698 Ord. No. A16984 pare filter cassettes are delivered in package of 1 pcs, i.e. 5 replacements. Carbon filter cloth to reduce odours in supply air available. Contact your supplier for information on options. O P T I O N A L ACCEORIE F L E X I B L E I N TA L L AT I O N OPTIONAL ACCEORIE ENOR YG 61 Room hygroat relative humidity sensor AD MOKE 4 Cigarette smoke and air quality room sensor AD R 4 Relative humidity room sensor AD C 4 CO room sensor AD C D CO duct sensor Ord. No. A14 Ord. No. A1411 Ord. No. A1418 Ord. No. A1419 Ord. No. A14 B5 silentblocks set Ord. No. A165