Flammable. cabinets. Corrosive. cabinets. Toxic cabinets. and multirisk. Pesticide range. Fume hoods, filtering. cabinets - Ventilation

Similar documents
SAFETY CABINETS FOR CORROSIVES

EN Storage of gas cylinder

Flammable Safety cabinets for toxics and Multirisk safety cabinets

Flammables Safety Cabinets

Safety Cabinets STORAGE. KEWAUNEE encouraging new discovery FLAMMABLE & CORROSIVE

Explosion-Proof Waste Chemical Storage Cabinets

UTILITIES SICUR WOOD 61 SICUR 63 SICUR KEM 64 SICUR SHELF 65 PHYTOSAFETY 66 DRUM STORAGE SUMPS 67 ABSORBENT PADS 68 EMERGENCY EYE AND BODY SHOWER 69

UNDERSTANDING SAFETY CABINETS

Safety Cabinets / Width 1200 mm / 2 Doors. Height 1968 and 1298 mm Height 1968 mm Height 1968 mm. Folding door. Type 90. Type 30

FIRE MY11 - FIRE RADIO MY11 SAFETY CABINETS CERTIFIED FOR THE STORAGE OF FLAMMABLE AND RADIOACTIVE PRODUCTS

2. Occupational safety/security Furniture/Stairs-Fume hoods

4 Storage cabinets SCALA

Safety Cabinets. Flammable Storage Cabinets. Paint/Ink Cabinets YEAR YEAR YEAR

Steel Casework Acid Storage

>>> FIRE MY11 >>> ACCORDING TO VERSIONS NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS

L a b o r a t o r y E q u i p m e n t C a t a l o g

Well. informed! Edition compact 3 Professional Storage of Hazardous Materials. Technical Highlights Facts and Consequences

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

We are your partner for security and environment protection

Dangerous Goods Storage Cabinets

Safety cabinets for the safe storage of flammable liquids and other hazardous materials. Type 90 Type 30

V-LINE The new formula for the storage of hazardous materials

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Metal shelving Meccanocar line "Taurus" Base Module. Workshop furniture

FLAMMABLE LIQUID CONTAINERS

Innovation in air purification unmatched air quality

Flammable Liquid Storage

Ultra low temperature freezers. -40 C and -86 C. Green Line

BIO REMEDIAL CLEANERS

For perfect office organisation.

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

SAFETY CABINETS & CANS WHEN SAFETY COUNTS

FLAMMABLE. Liquid Storage Cabinets. Trafalgar range of safety cabinets:

XPert Balance and Bulk Powder Enclosures

COOL line Safety storage cabinets in modern design. Type 90. Fire-proof refrigerators for maximum fire protection

Technical Ventilation

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

SECTION AIR DUCT ACCESSORIES

Applications Damage service Building drying Water works Dry storing FEATURES

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

Reach-In. PLanT GROWTh. Reach-In

Scientific Equipment & Furniture Association SEFA Recommended Practices For Liquid Chemical Storage Cabinets

Banham t f Safe Catalogue

Wiring Duct Product Selection Guide

LIMITED METAL WARRANTY

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

ALWAYS REMEMBER - IF IN DOUBT ASK THE PERSON WHO KNOWS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

RAMIRENT CDT 30. Applications Damage service Building drying Water works Dry storing FEATURES

Laboratory Refrigerators and Freezers

Treating Kitchen Exhaust Discharge for a Greener World

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Workbenches Tool carts Metal lockers.

Confined Space Ventilation equipment

Drester High performance Gun Cleaner for all paint systems

CAESAREA SUBSTATION BATTERY ENERGY STORAGE SYSTEM PREFABRICATED EQUIPMENT CONTAINER SPECIFICATION ATTACHMENT TO ANNEXURE "B"

Explosion Protection. Process Safety. Quality Solutions.

CABINETS AGF BROME KNOWS YOUR CHALLENGES!

HOLDING/PROOFING CABINETS HP2H-2M-SN APPLICATION OPTIONAL MODULAR CONSTRUCTION

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

electronics Protection

Lista Premium 75/200 Drawer cabinets, workbenches and partition material

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Banham t f Safe Catalogue 2014

DOD FUELS LABORATORY STANDARDS UFC

19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Talos Steel Range. T: +44 (0) F: +44 (0) E: W:

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

STR-Series Indirect-Fired Air Turnover Units

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

PLC Control Touch-Screen

Latch key safety limit switches Technical data

ENVIRONMENTAL HORTICULTURE: AGRISCIENCE AND BIOTECHNOLOGY September 30, 2010

Precision Containment for All Applications

OXYVD8WCOUS OXYVG8WCOUS OXY2TVD6COUS. User manual. - A brand of EuroCave Group -

Q u iet Q u i c k P a y l o ad T o u g h

User manual. - A brand of EuroCave Group -

University of California, Davis Laboratory Self-Inspection Checklist

Safety and environmental protection. Safe flammable storage aboard cruise ships

Safety storage cabinets with recirculating air filter technology. The safety storage cabinet for storing and filtering various hazardous materials

Treston ESD Storage Systems Picking Bins. Stacking Bins

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery

Dangerous Goods Storage Cabinets. When only the best will do for the internal storage of your chemicals. Environmental and site safety solutions

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

Working safely with flammable liquids

think safe BURGLAR AND FIRE RESISTANT SAFES Dealer catalogue

Gerber Centrifuge Micro II. Instruction Manual (e)

SECTION (15820) - AIR DUCT ACCESSORIES

Volts 115 Wiring Diagram Owner's Guide Eng/Spn Owner's Guide French

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

English. Medication, Plasma, Blood, Lab Supplies Organisation in the Refrigerator FRIDGES KS-E01

Digital incubating/ refrigerating benchtop shakers

Range of products for PATHOLOGY and LABORATORY. Mortuary Refrigerators Equipment for Autopsy Rooms Equipment for Laboratories

Transcription:

and Files - Ventilation range Toxic SAFETY CABINETS FOR CORROSIVES 35 Flammable

Flammable SAFETY CABINETS FOR CORROSIVES INTRODUCTION: For safety reasons, acids and bases must be stored in safety in order to prevent any risk of leaks or breakages of bottles. You must also pay attention that different product families must be separated in compartments or stored into different. Some of our are divided in compartments, allowing storage of different product families. Toxic ranges - Ventilation and Files This catalogue presents our range of safety for several corrosives solutions of storage. Whatever your field of activity may be (laboratory, industry, warehouse, production unit, ), if you store corrosives (little to extremely corrosives), you must store them in safety. Do not hesitate to contact us for a personal and quick advice. What is a safety cabinet for corrosives? Two different types of storage can be proposed concerning corrosives: The first type, dedicated to slightly corrosive products, are steel safety with high resistant paint. These offer additional protection in high density polyethylene or PVC for the shelves and the bottom retention tank. The second type, dedicated to high corrosive products (such as nitric, sulfuric, hydrochloric or fluorhydric acids) are made in high density polyethylene or cellular PVC. These materials offer the perfect resistance to corrosives vapours. Is forced ventilation needed? A forced ventilation is a prerequisite in order to improve the life cycle and the safety of a steel cabinet. Indeed, despite the fact that the steel is protected by a resistant epoxy paint, nothing can protect against the possibility of corrosion inside a steel safety cabinet. Moreover, to protect the users health, it is highly recommended to install an exhausting system, whatever the material used for the cabinet, in order to eliminate any concentration of dangerous vapours inside the cabinet. We invite you to have a look at the different vent solutions proposed (fan, exhausting system, filtration by active coal, etc ) at the end of this catalogue to find the right one adapted to your needs. Do not hesitate to contact us for any information. NORMALIZATION: FM (FACTORY MUTUAL) : Offers worldwide industrial and commercial product certification and testing services through its business unit FM Approvals. Recognized and respected across the globe, FM Approvals certification assures customers that a product or service has been objectively tested and complies to the highest national and international standards. European norm EN 14470-1: It is applicable for storage of flammable and highly flammable chemicals in a laboratory. The flammables used in laboratories must be stored in one or several safety which are fire resistant 15 (minimum required), 30, 60 or 90 minutes. NF X 15-211 - mai 2009 norm: The standard indicate on the ventilation and filtration efficiency, as well as the efficiency for the recirculatory fume hood designed for chemicals use in laboratories. Summary FM safety for corrosive products FM Range 4 Corrosion resistant laboratory for acids and bases I.N.R.S. Range 8.A Polyethylene safety I.N.R.S. Range 10 EN 14470-1 NF X15-211 10/2014 Corrosion resistant laboratory for acids and bases I.N.R.S. Range 8.B EN 14470-1 Safety Cabinets - Type 30 minutes for acids and bases EN 14470-1 Range 7030.M 36 Safety with 2 compartments I.N.R.S. Range 11.A

RANGE 4 FM - NFPA - OSHA FM safety for corrosives (1) Flammable B18M B18M B30M Toxic CONFORMITy - In compliance with NFPA (National Fire Protection Association), OSHA (Occupational Safety and Head Administration), UL (Underwriters Laboratories) and FM (Factory Mutual international) specifications. - Sturdy construction for use in industry. - Integrated self-latching handle. - Continuous piano hinge provides smooth closure. - Various models available. - Built in double wall steel with 38 mm of insulating air space. - Blue epoxy paint. - Adjustable galvanized spillslope safety steel shelves with high density polyethylene (HDPE) shelves trays. Closing doors Manual Outside dim. Inside dim. Storage (L) - Liquid tight containment sump holds leaks on the bottom (50mm heigh). - Static ground connection. - B24M and B24S models euipped with extra polywork tray. - High and low vent (Ø 50mm) with grid. - Continuous piano hinge. - Self-closing (2) or manual doors. - 3 points stainless steel bullet latching system. - Doors with key-locking system. OPTIONS - Additional shelves. - Industrial absorbent mats for retention tank (10 pieces by pack JF10D). - Ventilation or filtration boxes. (L) shelves HDPE protections Maximum load by shelf (3) B04M 610 x 430 x 460 465 x 345 x 360 15 6 1 2 159 B04S Slef-closing 32 B18M Manual 75 610 x 1090 x 460 515 x 1005 x 390 64 20 1 2 159 B18S Slef-closing 78 ESP18 - Additional shelf for 64 litres cabinet 4 B22M Manual 90 1650 x 585 x 460 1560 x 500 x 390 86 10 3 4 159 B22S Slef-closing 92 ESP22 - Additional shelf for 86 litres cabinet 4 B24M Manual 92 910 x 890 x 560 710 x 795 x 455 90 18 1 2 159 B24S Slef-closing 95 ESP24 - Additional shelf for 90 litres cabinet 4 B30M Manual 105 1120 x 1090 x 460 1025 x 1005 x 390 113 20 1 2 159 B30S Slef-closing 108 ESP30 - Additional shelf for 113 litres cabinet 5 B45M Manual 140 1650 x 1090 x 460 1560 x 1005 x 390 170 20 2 3 159 B45S Slef-closing 143 ESP45 - Additional shelf for 170 litres cabinet 5 B60M Manual 170 1650 x 860 x 860 1560 x 770 x 780 228 30 2 3 159 B60S Slef-closing 173 ESP60 - Additional shelf for 228 litres cabinet 9 (1) These are not designed for high corrosive products (nitric acid, sulfuric acid, phenol, hydrochloric) and require an exhausting system to improve their life cycle. For the high corrosive products please refer to our Ranges 8.A and 10. For the exhausting system refer our V Range. (2) According to models (3) Evenly distributed W. 30 08/2015 range - Ventilation and Files 37

Flammable RANGE 8.A Corrosion resistant laboratory for Acids and Bases Toxic Secondary compartment ranges - Ventilation and Files APC106 CERTIFICATION - Large warning lables in compliance with ISO 3864, 92/58/CEE European directive and NF X08.003 norm. - In compliance with recommendations of The National Institue for research and Safety at work (I.N.R.S). - Especially designed for acid and bases storage. - Built in cellular PVC with a great resistance to vapour aggresions and corrosives liquids. - Cabinets with sliding drawers for acid or/and base storage. Outside dim. H x W x D (mm) APC31 compartment Major Secondary APC221 - Built entirely in white cellular PVC. -, «Base» and «Toxic» large warning labels (only the 3 for APC106 model). - Adjustable retention sliding drawers for each major compartment. - Independant compartments (except APC31 model) for acid, base or/and toxic products storage (only for APC106 model). Drawers in major retention - Each compartment is divided in a major and a secondary storage area (except APC61, APC111 and APC221 models). Shelves in second. APC111 APC61 - High and low opening vent Ø 100 mm with connecting piece for possible exhaust. - Door(s) with lock : Handling door(s) for APC31, APC91 and APC106 models. Sliding doors for APC61, APC111 and APC221 models. - Adjustable leveling feet for enhance stability. Recycling AirBox labopur - H50 Take advantage of labopur s technology with any safety cabinet. Active coal filters absorbtion s and filtration system are tested and certified NF X 15-211. Storage (L) Maximum load by shelf (1) APC91 APC31 670 x 635 x 615 1 1 2 2 68 28 20 30 APC61 670 x 1135 x 615 2-4 - 96 44 20 60 APC91 1850 x 635 x 615 2 2 6 6 150 84 20 90 APC111 900 x 1135 x 615 2-6 - 144 66 20 110 APC106 1850 x 635 x 615 3 3 5 5 170 70 20 83 APC221 1850 x 1135 x 615 2-8 - 192 88 20 155 E8A2 shelf/sump sliding 20 11 6 Weight 08/2015 38 (1) Evenly distributed

NOTES Flammable 02/2015 Toxic range - Ventilation and Files 39

Flammable RANGE 8.B CORROSION RESISTANT CABINETS for Acids & Bases Secondary compartment Toxic New slide rails with drawer stop ranges - Ventilation and Files Outside Dim. APC222 compartment APC62 CERTIFICATION - Large warning labels in compliance with ISO 3864, 92/58/CEE Euro- pean directive and NF X08.003 norm. - In compliance with recommendations of The National Institute for research and Safety at work (I.N.R.S.). - Especially designed for acids and bases storage. - Built in melamine-based wood with a great resistance to corrosive vapours aggressions. - Cabinets with sliding drawers for acids or/and bases storage. - Built entirely in white melamine-based wood. -, «Base» and «Toxic» large warning labels (only the 3 for APC107 model). - Adjustable retention sliding drawers for each major compartment. - Independant compartments (except APC32 model) for acid, base or/ and toxic products storage (only for APC107 model). - Each compartment is divided in a major and a secondary storage area (except APC62, APC112 and APC222 models). Major Secondary Drawers in major retention Shelves in second. Storage APC92 - High and low opening vent Ø 100 mm with connecting piece for possible exhaust. - Door(s) with lock: Handling door(s) for APC32, APC92 and APC107 models. Sliding doors for APC62, APC112 and APC222 models. - Adjustable leveling feet for enhance stability. Recycling AirBox labopur - H50 Take advantage of labopur s technology with any safety cabinet. Active coal filters absorbtion s and filtration system are tested and certified NF X 15-211. (L) Maximum load by shelf (1) APC32 670 x 635 x 615 1 1 2 2 68 28 20 30 APC62 670 x 1135 x 615 2-4 - 96 44 20 60 APC92 1850 x 635 x 615 2 2 6 6 150 84 20 90 APC112 900 x 1135 x 615 2-6 - 144 66 20 110 APC107 1850 x 635 x 615 3 3 5 5 170 70 20 83 APC222 1850 x 1135 x 615 2-8 - 192 88 155 E8A2 Shelf / base trough sliding 20 11 6 W. 08/2015 40 N.B. : The melamine-based wood may be affected by corrosive liquids attacks. Acids and bases bottles must be stored in the HDPE base trought. Moreover, all spills must be quickly cleaned. (1) Evenly distributed

RANGE 3030.M EN 14470-1 FM 6050 EN 14470-1 & FM (1) 30 MINUTES SAFETY CABINETS for acids and bases CERTIFICATION - Tested and approved Type 30 according to EN 14470-1 (04-2004) and EN 1363-1 (06-2000). - (1) Tested and approved 10 minutes according to FM 6050 (Factory Mutual internationnal). - Normalized labelling according to ISO 3864 and EN 14470-1 (04-2004) norms, 92/58/CEE european directive and FM regulations. - 30-minute fire resistance according to ISO 834 fire heating curve. - Pedestal area under-driveable by a forklift by removing panel (except for the under-bench models). - Self-closing doors with possibility to keep the door(s) open. If the temperature rises to 43 C, a fuse link closes the door(s) automatically. - Built in melamine-based wood : high chemicals resistance. - Grey structure (RAL 7035), yellow edges (RAL 1023). - Safety labelling as per EN 14470-1. - shelves adjustable in height (step every 32 mm). - Removable bottom containment sump. - Air inlet and outlet Ø 100 mm connecting pieces for possible exhaust. - Self-closing doors. - Doors with a lockable three-point latching mechanism. - Lockable non-sparking. - Adjustable leveling feet for enhance stability. Ventilation and Filtration Boxes To protect the users health and to improve the life cycle of your safety cabinet, we recommend to install an exhausting system. Do not hesitate to contact-us for more information. Description Outside Dim. Inside Dim. H x W x D (mm) OPTIONS - Additional retention shelf (depending on model). - Perforated cover plate for base trough. - Self retracting shelf. - PVC shelf and retention tank - Ventilation or filtration boxes. - Industrial absorbing mat (: JF10D). Recycling AirBox labopur - H50 Take advantage of labopur s technology with any safety cabinet. Active coal filters absorbtion s and filtration system are tested and certified NF X 15-211. Storage (Kg) Shelves Delivered with sump Maximum load by shelf (1) Steel PVC Steel PVC 3035M11 Tall cabinet, 2 doors, 2 compartments 1980x1115x550 1560x1000x475 180 6 option 1 option 30 232 E703148 Additional shelf 30x490x410 - - - - - - - 3 C703148 Perforated cover plate 100x490x410 - - - - - - - 4 SE703148 PVC containment shelf for E703148 30x485x405 - - - - - - - 2 SB703148 PVC base trough 100x485x405 - - - - - - - 3 Weight 08/2015 Flammable Toxic range - Ventilation and Files N.B. : The melamine-based wood may be affected by corrosive liquids attacks. Acids and bases bottles must be stored in the HDPE base trought. Moreover, all spills must be quickly cleaned. (1) Evenly distributed 41

Flammable RANGE 11.A VENTILATED SAFETY CABINETS for Acids and Bases ranges - Ventilation and Files Toxic 42 CERTIFICATION Additional shelf in PVC for Acid compartment - Large warning labels in compliance with ISO 3864, 92/58/CEE European directive and NF X08.003 norm. - Electric fan in compliance with CE regulations. - Stricktly separated acid and base storage. - Built in steel 15/10 th. - Double wall doors in steel 15/10 th. - White epoxy paint RAL 9010. - «Acids» and «Bases» large warning labels. - shelves in steel adjustable in height. - Adjustable steel containment shelves. AB75 Fan integrated - Additional containment shelves in PVC for «Acid» compartments. - Removable base through in steel at the bottom of each compartment (except «Acid» compartments: base through in PVC). - High and low vents Ø 100 mm (for possible external connection). - Handling doors with key-locking system. - Electric fan: 220/240 volts - 50 Hz - 40 W - 0,19 A - 54 db(a) - Flow: 156 m 3 /h - Protection: IP44. OPTIONS - Industrial absorbing mat (ref. JF10D). - Flexible tube (ref. KL100). - Clamp collar (ref. CDS100). Description Compartiment Dimensions Nb of Nb of Compartment type Maximum W. containment Fan load by shelves sump Storage (L) (L) shelf (1) AB75 Tall cabinet with fan Ext. 2080x560x560 Int. (2x) 890x530x470 156 m 3 /h x x - 50 78 AB75SC Tall cabinet without fan Ext. 1830x560x560 110 (2x 55) 70 (2x 35) 4 2 - x x - 50 68 AS75SC Tall cabinet without fan Int. (2x) 890x530x470 - x - x 50 68 (1) Evenly distributed The manufacturer reserves the right to discontinue or change specifications or designs 08/2015 at any time without notice and without incurring obligations.