Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

Similar documents
Convertible radiator valve for one-pipe systems, centre distance 35 mm

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

caleffi hydronic valves page 1 of 12

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Thermostatic mixing valves with replaceable cartridge for centralized systems

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

STRAIGHT AND ANGLED THERMOSTATIC VALVES

TRV 300 RADIATOR VALVES

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Compact wall hung boiler. Micro processor Brass Hydraulic set

Data sheet Thermostatic sensors type RA 2000

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Multilux 4-Eclipse-Set

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

Thermostatic valves with radiator connection systems

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

Section - A. Radiator Valves

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Halo. Thermostatic heads with built-in sensor

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

IMESA: A LIFE BY YOUR SIDE

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

K-HA CENTRIFUGAL PRESSURE BOOSTING PUMPS. Technical Sheet

Thermostatic mixing valves with interchangeable cartridges

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Electronic Frost Thermostat

COMPANY PROFILE. CoMETA Group srl

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

RA2000 Commercial TRVs

Operating instructions for Grumbach Incubators

Co170 ARMOURED WALL BURGLAR PROOF GRADE 2 ACCORDING TO UNI EN1143

The Right Temperature, Always THS Series Modular Thermostats

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Dynamic thermostatic radiator valves DYNAMICAL

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Radiator Valve Program

DEVIATING VALVES ART K063

PCH Heating Condensing Module for Air Handling and Roof Top Units

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Thermostatic Concealed Shower Valve

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

EVM/A 16 F 3~ 50Hz CAMICIA ESTERNA Outer casing DISCO P/TENUTA Casing cover

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

LOW SURFACE TEMPERATURE RADIATORS

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

STREBEL S-CB + Cascade Kits

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

15x15 Diamantato White Lux 7,5x15 Diamantato White Lux 5x15 Cornice Liberty White Lux 2x15 Bullnose White Lux 11x15 Battiscopa 900 White Lux

USER S MANUAL WITH REFERENCE TO THE STANDARDS IN USE FLYWHEEL SLICERS MOD. 370V-330V

Installation and operating instructions

Thermostatic Bath Shower Mixer. Without shower kit.

Electronic Room Thermostat

USE, INSTALLATION AND

SOLUTIONS GUIDE. For total efficiency

Flush individual room control for floor heating systems

FCF: forced air convection ovens

Radiator Trap Radiator Valve

Co153, Co154 SECURITY SHUTTERS RC3 GRADE ANTI-BURGLARY CERTIFICATION UNI EN1627 P6B GRADE ANTI-BURGLARY CERTIFICATION UNI EN356

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

Pole Mounting System Installation & Certification Manual

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

Regulux. Radiator lockshield with drain-off facility. To be precise.

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

INSTALLATION INSTRUCTIONS

Radiators: indirect energy metering and components

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

05/2014. Mod: E99/PLA2-N. Production code: BEFT908L

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Instruction Manual. Oil Heaters. Model: OIL5, OIL7, OIL9 & OIL11T READ AND SAVE THESE INSTRUCTIONS

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

Sifoni Cromati e pilette Chrome plated siphons and waste

RA2000 Thermostatic Radiator Valves

MODULAR AND MULTIFUNCTIONAL SIGNALING DEVICES ENGINEERED FOR CIVIL AND INDUSTRIAL APPLICATIONS MORE THAN BRIGHT IDEAS

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.

IMI Heimeier Kit Hydroca ble

Transcription:

Technical Data Sheet Thermostatic Heads TT3000 TT3000C TT3002 15/02/2018 Function Thermostatic valves allow to make each room independent with a specific set temperature, thus enhancing comfort and actual energy saving, as prescribed by national and international regulations. The sensor inside the head regulates the opening and closing of the valve by reacting proportionally to temperature changes, thus allowing for room temperature adjustment. It is vitally important not to install thermostatic heads under barriers such as shelves, curtains and pieces of furniture, or in a vertical position. These obstacles can store heat and thus distort the detection of room temperature. Technical data Max. working pressure: 10 bar Max. differential pressure: 1 bar Max. working temperature: 120 C Min. adjustment temperature: 6 C Max. adjustment temperature: 30 C (TT3000, TT3000C), 28 C (TT3002) Energy saving conditions: Pos. 3 = 20 C Working fluids: Water in compliance with UNI 8065:1989 Hysteresis (C): < 0.4 K Differential pressure influence (D): 0.5 K Response time (Z): 22 min. Water temperature influence (W): 0.25 K Inalterability range: -15 C +60 C Storage temperature: -20 C +50 C Materials Sensor: Liquid Head: RAL9016 white ABS (TT3000, TT3002), chrome-plated ABS (TT3000C) Collar: CW 614 N UNI-EN 12164-2016

Dimensional Drawings TT 3000 Thermostatic head with integrated control and sensor. Thermostatic head with integrated control and remote sensor. Standard length of capillary 2 m. Code Size A B C E F Code Size A B C E F 69100000 M30 x 1,5 75 80 46,5 - M30x1,5 69100020 M30 x 1,5 75 80 46,5 - M30x1,5 Code Size A B C E F Code Size G H L M N 69100000BRA* M30 x 1,5 75 80 46,5 - M30x1,5 69100020 M30 x 1,5-35 96 - - *With Braille numbers TT 3000C Thermostatic head with integrated control and sensor. BT 242 Tamper-and-theft-proof clip for TT 3000 and. Code Size A B C E F Code Size A B C D E 69100000 M30 x 1,5 75 80 46,5 - M30x1,5 69010402-50.5 28.5 - - -

Approvals The TT 3000 thermostatic head complies with the European Standard EN215:2004/A1/2006. TT 3000 thermostatic heads is certified in combination with the following thermostatic valves: RS202 DN15; RS206 DN15; RS212 DN10; RS212 DN15; RS209 DN10; RS209 DN15; RS212/A DN10; RS212/A DN15; RS209/A DN10; RS209/A DN15; RS2502 DN15; RS2506 DN15; RS2512 DN10; RS2512 DN15; RS2509 DN10; RS2509 DN15; RS2512/A DN10; RS2512/A DN15; RS2509/A DN10; RS2509/A DN15. The TT 3000 thermostatic head is classified as a low thermal inertia device and therefore complies with the requirements set out in the Italian Decreto del Ministero dell Economia e delle Finanze del 19 febbraio 2007, Disposizioni in materia di detrazioni per le spese di riqualificazione energetica del patrimonio edilizio esistente, ai sensi dell art. 1, comma 349, legge 27/12/2006, n. 296. The TT3000 thermostatic head has obtained the Class I Thermostatic Efficiency Label (TELL). Design and Function 1. Adjustment knob 2. Liquid sensor 3. Piston 4. Body 5. Fastening collar The thermostatic head consists of a sensor (2) filled with a highly expandable liquid. This liquid, which is placed inside the adjustment knob (1), expands or contracts in proportion to room temperature changes, reacting even to the smallest variation. When the surrounding temperature increases, the element expands and acts on the obturator with an axial thrust movement (3), thus controlling the valve s action. The flow of the heating medium can be adjusted by opening and closing the valve. When the temperature decreases, the opposite occurs thanks to the thrust generated by the return spring. Thermostatic heads precisely maintain the set room temperature. The required value is set by turning the adjustment knob, the numbers on it correspond to different temperatures. Range of Adjustment TT 3000 - TT 3000C 6 C 12 C 16 C 20 C 24 C 30 C 1 2 3 4 5 6 C 12 C 16 C 20 C 24 C 28 C 1 2 3 4 5

Working Instructions Before installing the thermostatic head, set the adjustment knob to 5, so as to facilitate the following installation steps. Unscrew the RAL 9016 white ABS protection cap mounted on THERMOTEKNA thermostatic valves. Tighten the brass collar of the thermostatic head to the valve body, then set the knob to the desired position. Conditions for a Proper Functioning Fig.1 Fig.2 Fig.3 Fig.4 Fig.5 Fig.6 Thermostatic heads must be installed away from the heat streams surrounding the heating body (fig. 1) and direct sunlight (fig. 2). Do not install thermostatic heads under shelves (fig. 3), in a recess (fig. 4), within the heat stream (fig. 5) or behind curtains (fig. 6). These kinds of installation are not proper, as they may cause the head to measure temperature values which do not coincide with the actual room temperature. In order for the system to function properly, it is advisable to install a pressure relief valve between the inlet and the outlet. To avoid excessive noise in the system it is recommended not to use thermostatic valves with ΔP value above 0,2-0,25 bar. During summer it is recommended to set the heads to the maximum opening so as to avoid issues connected with an excessive force applied on the valves s screw in closed position.

TT 3000 TT3000 thermostatic heads can be applied to all heating bodies unless in presence of barriers such as shelves, curtains or furniture, which may accumulate heat and therefore alter the measurement of room temperature. In this case, it is recommended to use TT3002 thermostatic heads with remote sensor. Placing and Installation of the sensor 1,5 m Place the sensor as shown in the picture. 10 cm Fasten the sensor case with the included screws and dowels.

Fasten the capillary with the U-bolts and nails included in the package. WARNING: Take care not to crush, pierce or tilt the capillary Limiting and Blocking Temperature The head s temperature range can be limited or locked by using the provided fork pin. Blocking the adjustment To lock the temperature to a fixed value, for example 3 : turn the knob so that the indicator corresponds to the required position. Insert the fork pin across the spline placed in the lower part, diametrically opposite to the index. Limiting the temperature range To limit the temperature range between a chosen value and a maximum limit, for example 3 and 5 : Insert the fork pin to the left of the spline. To limit the temperature range between a chosen value and a minimum limit, for example 3 and : Insert the fork pin to the right of the spline. Working Instructions BT 242 Tamper-and-theft-proof clip for TT 3000 and. The tamperproof and antitheft version of the thermostatic head is formed by fitting a suitable shell to the knob as shown in the illustration on the side. It is secured with two screws with a special head and can therefore only be tightened with the appropriate allen key.

Item Specifications TT 3000 Low thermal inertia thermostatic head with integrated control and sensor, liquid sensitive element. Graduated scale from to 5, corresponding to an adjustment range of 6 C to 30 C. Possibility to limit and lock the temperature. Low thermal inertia thermostatic head with integrated control and remote sensor, liquid sensitive element. Graduated scale from to 5, corresponding to an adjustment range of 6 C to 30 C. Possibility to limit and lock the temperature. TT 3000C Low thermal inertia thermostatic head with integrated control and sensor, liquid sensitive element. Graduated scale from to 5, corresponding to an adjustment range of 6 C to 30 C. Possibility to limit and lock the temperature. BT 242 Tamper-and-theft-proof clip for TT 3000 and. ~ Luxor S.p.A. Sede amministrativa, stabilimento e uffici commerciali: via Madonnina, 94 25018 Montichiari - (BS) Italy Administrative office, factory and commercial office: Tel.: 030-9961161 Fax: 030-9961165 info@luxor.it www.luxor.it Luxor si riserva il diritto di apportare miglioramenti e modifiche ai prodotti descritti ed ai relativi dati tecnici in qualsiasi momento e senza preavviso - Luxor reserves the right to ameliorate and modify the above products and their technical data at any time and without notice