HOTSPOT

Similar documents
HOTSPOT. Industrial-suited parametrizable Infrared heat detectors with integrated signal processing and evaluation

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

Industrial Fire Detection

HOTSPOT-1000 HOTSPOT Thermographic Surface Temperature Detector. Installation - Operation - Maintenance EN11

Industrial fire alarm systems

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

Gas Sensor Fire Detector GSME-Ex

Engineering Guideline. pac- Carriers Type Universal

COMPACT FLAME CONTROLLER CFC 100

COMPACT FLAME CONTROLLER CFC 2000

Danfoss gas detection unit Type GD Heavy Duty

RS485 MODBUS Module 8AI

COMPACT FLAME CONTROLLER CFC 1000

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Flame Monitors BROCHURE

FDA241, FDA221 Siemens ASD

Snifter ATEX22 VERSION. User Manual. Distributor

Coal Pile Fire Monitoring System

More Precision. thermometer // Non-contact IR temperature sensors

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Danfoss gas detection units

Line Smoke Detector LRMX

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Danfoss gas detection units

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Fire and Gas Monitoring Panel ST7-HV

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Power Supply Display Module PSDM. Installation and Operation Manual

Talentum - Why use our Flame Detectors?

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Advantages / Characteristics

Coal Control. Belt Rip Detection System Type BPS-A1 and BEPROS-S1. Gesellschaft für Automation mbh. Technical changes reserved.

Danfoss gas detection Controller unit

FDA241, FDA221 Siemens ASD

Gas Controller Module GC-06

SS-100. Pyrometer. Temperature Range: 800~2400

PYROsmart. The intelligent infrared early fire detection and extinguishing system

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Remote alarm indicator and test combination MK2430

Fire control panel detect 3004 plus and accessories

HART XL High Sensitivity Smoke Detection

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Infrared Temperature Sensor

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

Retroreflective sensor with polarization filter

Innovation right to the point. Optical distance detection. Low cost and compact due to PMD technology.

Process Alarm Module RTA 421

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Bernstein product overview

Instructions for the fan motor control system, SILVER C

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Heatless Desiccant Compressed Air Dryers

APPLICATION DATA SHEET

HART XL High Sensitivity Smoke Detection

PolyGard 2-channel Gas Controller MGC-03

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Model 5610 Infra-red Transit Heat Sensor

FIRE ALARM SYSTEM VER.15.1

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Thermal Management Products & Accessories for Enclosures

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Natural Ventilation Controller with 24vDC drive NVC-1204

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

EasyLog Data Logger Series

Quickheat 30 weather compensated boiler control

Maxline 2 Thermal Imaging Solutions for Manufacturing

Dew-Point Transmitters and Instruments

APPLICATION DATA SHEET

Multi-Gas-Controller MGC2

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

EasyLog Data Logger Series

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

EL-OEM-3 OEM Packaged Voltage Data Logger

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

46C SERIES. powerreserve. Photoelectric sensors and light scanners with maximum function reserve.

SIHI Dry GD S Sizes S450, S650

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

Ionisation single-tube smoke detector for duct mounting

EPURE. LED surgical lights A fusion of design and innovation. Design that cares. Operating theatre

Quick Selection Guide Fire Systems LSN Periphery

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

Conspec - Why use our Flame Detectors

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

OIL MIST DETECTION SYSTEMS VISATRON

Open-area Smoke Imaging Detection (OSID)

Transcription:

HOTSPOT-1000 HOTSPOT-1000 Infrared heat detector with programmable internal signal evaluation for the detection of hot surfaces, flames and moving ember - suitable for industrial applications Characteristics Robust design with aluminum die cast housing Purge air adapter with 4-mm quick connectors Integrated detector heating Extensive tolerance towards humidity and dust Fast response time Adjustable alarm thresholds for each pixel Detection is not affected by air flow Fast and simple wiring with aid of bayonet connector Central data archiving and visualization with service PC Interface for the connection to common fire alarm systems Applications Detection of hot surfaces, flames and moving ember and hot spots Monitoring of machinery and equipment Conveyor systems for coal, biomass, wood, paper, plastics and refused derived fuel (RDF) Storage facilities and bunkers for spontaneously inflammable material, silos and mills Drives, shredders, dryers, coolers, chutes and funnels Available for ATEX zones 20/21 and 22 (HOTSPOT-X20, HOTSPOT-X22) ADICOS HOTSPOT detectors are infrared thermographic detectors of the Advanced Discovery System ( ADICOS ), which were especially designed for reliable early fire detection in industrial surroundings. The HOTSPOT-1000 is used for contact-free early temperature monitoring and detection of moving ember. It has an integrated thermal camera with 1000 heat sensitive pixels, which is capable of receiving individual parameters. The robust design protects the devices against impairments by dust and humidity, which enables them to operate in rough industrial surroundings. ADICOS HOTSPOT-1000 is especially suitable for process and storage monitoring, in applications with spontaneously inflammable bulk material as well as the surveillance of conveyor systems. Bulk material and equipment in danger of overheating can be observed at the same time. A decentralized power supply unit is required to power the HOTSPOT-1000 detectors. The ADICOS M-BUSMAS- TER or the ADICOS fire panel manage the communication between the elements of the system. The ADICOS Central Software displays the detector status and temperature curves and images and allows to set individual sensitivities and thresholds of any connected detector. The HOTSPOT also includes a conventional fixed-image camera, which makes commissioning considerably easier. www.adicos.com 425-2410-002 EN2.1-10/2018 page 1 / 5

HOTSPOT - Specification Mechanical dimensions All dimensions in mm Mechanical characteristics Enclosure Coated aluminium diecast (corrosion-resistant) Weight 0,6 kg Protection class IP 64 Dimensions (h x w x l) 90 x 100 x 100 mm Thermal characteristics Relative humidity Temperature range -10... +50 C 0... 99 % (non-condensing) In case of continual condensation, use internal heating Electrical characteristics Supply voltage Power consumption (without internal heating) Power consumption (with internal heating) Internal fusing M-Bus max. line length M-Bus max. line capacity M-Bus baudrate Limit contact alarm relay Limit contact error relay 24... 4 DC (Error-status at 2 or less) 1 VA 1A 750 ma 2 km 200 nf 4800 baud 680 Ω, 20 ma max. (Alarm (NO) relay), further configurations on request 0 Ω, 4 bzw. 20 ma max. (Failure (NC) relay), further configurations on request Technical changes reserved! 425-2410-002 EN2.1-10/2018 page 2/5

HOTSPOT - 1000 Specifications Detector characteristics Sensor resolution 32 x 31 pixels Optical angle 53 x 52 Reaction time < 1 second Temporal resolution 0,1 second or 1 second (depending on pre-set configuration) Measuring range 0 C bis 100 C ADICOS topology concept ADICOS BMZ-30 External power-supply ADICOS NT V40-A3 (optional) ADICOS M-BUS ADICOS-AAB Further detectors ADICOS Service-PC ADICOS-detectors Electrical connection CONNECTION BOX NT Ext. Modul BMA BMZ30 / M-BM X7 (St) X6aus (Al) X6ein (Al) LOOP B LOOP A X7 (St) X6aus (Al) X6ein (Al) LOOP B LOOP A Cable occupation HOTSPOT-1000 NT / USV PE PE Colour red black Signal Supply voltage 24... 4 DC (non-polarised) Potential-free contact yellow Relay output X6 e Alarm (NO) white Relay output X6 a Alarm (NO) brown Relay output X7 a Failure (NC) green Relay output X7 e Failure (NC) pink blue violet grey blue/red grey/pink LEGEND: Fire panel interface B - in Fire panel interface A - in Fire panel interface B - out Fire panel interface A - out M-Bus max. 4 (non-polarized) add-on module (option, ex-factory) NT : External power supply Ext. Modul : Connection-module for FDnet or LSNi BMA : Non-ADICOS fire alarm panel BMZ30 / M-BM : ADICOS fire alarm panel BMZ30 or ADICOS M-Busmaster XF NT / USV : External power supply / uninterruptible power supply R 1 R 2 Alarm relay Standard R1 = 680 Ω R2 = B1 A1 B2 A2 X6e X7e HOTSPOT X6a X7a R 3 R 4 Error relay Standard R3 = 0 Ω R4 = Technical changes reserved! 425-2410-002 EN2.1-10/2018 page 3/5

HOTSPOT - Application Planning notes for ADICOS-Detectors ATTENTION! Planning of fire detection systems for industrial surroundings requires special expertise. Placement and alignment of ADICOS-etectors has to be done by specialist panners! Application example HOTSPOT with purge-air connection and HOTSPOT mounting bracket with ball joint for monitoring of a chute next to a conveyor belt HOTSPOT mounting bracket HOTSPOT-1000 puirge air connection Kür. Änderung Datum Ver. (Urspr.) (Ers.f.:) (Ers.d.:) Zeichnungsnummer: 410-2001-031...033 Blatt4 5 Bl. Bear. 20.04.2015 C. Pfeiffer Gepr. Norm HOTSPOT 256/100 with purge-air connection mounted on HOSPOT mounting bracket with ball joint Halbzeug: Datum Name Benennung: Helmholtzstr. 21 41747 Viersen Tel.: 02162-3703-27 Tolerierung ISO 8015 Allg. Toleranz DIN ISO 2768 m-k Oberflaeche DIN ISO 1302 Werkst.-Kanten DIN ISO 13715 Maßstab 7:10 Gew.: kg Werkstoff: Projekt: ADICOS HOTSPOT 256/1000 Dateityp: ASSEM Dateiname der Zeichnung: HOTSPOT-256-1000_PURGE_MBRACKET D E E D Required Purity level 8,5 C C 102 150 B B A A 76 105 1 2 3 4 Dust: 2 Humidity: 3 (-20 C dew point) Oil: 2 (<0,1 mg/m3) Required airflow rate Dust loaded: 2 l/min Dust loaded streaming air: 3 l/min In case of dust loaded air with a high velocity a test is recommended. Technical changes reserved! 425-2410-002 EN2.1-10/2018 page 4/5

Bestellinformationen System components Description Order-No. ADICOS BMZ-30 Compact fire alarm panel for administration of ADICOS detectors 425-2001-101 ADICOS M-BUSMASTER XF Master unit for ADICOS M-Bus and PC connection // M-Bus Repeater 420-2001-040 ADICOS Netzteil NT V40-A3 External power supply 40V, 3A 430-2001-030 Mounting accessories Description Order-No. ADICOS AAB Connection and branching box for all detector types 405-2002-037 HOTSPOT mounting bracket mounting bracket with with ball joint and tension lock 410-2003-018 ADICOS connection cable 5 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-01688 ADICOS connection cable 10 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-02236 ADICOS connection cable 15 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-03001 ADICOS connection cable 20 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-02387 ADICOS connection cable 25 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-03586 ADICOS connection cable 30 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-03039 ADICOS connection cable 35 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-03675 ADICOS connection cable 40 m Pre-assembled with ADICOS bayonet-plug for all detector types (except Ex) 95-31-03621 System software Description BOrder-No. ADICOS central software Software for parameterization and data-logging, unlimited detector support 405-2004-020 Maintenance accessories Description Order-No. HOTSPOT-Tester HTL2 Easy to use test unit for ADICOS HOTSPOTs 410-2402-008 ADICOS M-BUSMASTER S Compact portable M-BUSMASTER with USB interface 410-2001-045 Technical changes reserved! 425-2410-002 EN2.1-10/2018 page 5/5