TERM-E ELECTRIC HEATING AND VENTILATION UNITS

Similar documents
FHTERM HEATING AND VENTILATION UNIT

Units for suspended ceilings

HEATING AND COOLING DEVICE AGC

Energy-efficient heat source provides comfort in large rooms

42AM. Air heaters PRODUCT SELECTION DATA

Technology for life. Unit heater LH

Technical documentation

Gas heaters and convectors ROBUR

CAW Ceiling-mounted fan heaters for hot water

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Halton Rex 600 Basic R6B - Active chilled beam

Technical documentation: S1 S2 S3 S4

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Units for suspended cei lings

Technical documentation DTR

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

CASSETTE UNIT. Comfort Circle

OXeN. Ductless ventilation with heat recovery.

WOLF VENTILATION SYSTEM PRICE LIST

GAS AIR HEATER RANGE

Operation and Maintenance Instructions

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

OXeN. Ductless ventilation with heat recovery.

DUCTLESS VENTILATION WITH HEAT RECOVERY. OXeN ductless ventilation unit

VERSO Air Handling Units

Powrmatic PZN / PZN X Hot Water Heater

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

Ceiling diffusers. Type DLQL

Fan heater Panther WALL MOUNTED FAN HEATER

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Polaris-I-60. active chilled beam. the future of space conditioning

Technical documentation DTR. Farmer HCF in EPP casing

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

KLIMA Active Chilled Beams

GARAGE / WORKSHOP INFRARED HEATERS

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Carat. Chilled beams. Use. Worth noting. Installation. Key figures. lindab chilled beams

NEW GREEN TECHNOLOGY

Air curtain.

KOMFORT EC DB Suspended heat recovery air handling units

VERSO Air Handling Units

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Primo Hotel. General. Indoor climate units for hotel rooms

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series VENTS VUT R WH ЕС

Engineering Data Book

HEATING AND COOLING UNITS BRAVA

PREMIUM LUX 90LED VISIBLE

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

Engineering Data Book

Engineering Data Book

Passive chilled beams

Centrifugal air heaters hot water or electrical supply

PSFL , PSFL , PSFL , PSFL , PSFL

Halton Rex for Vario R6O - Variable air volume chilled beam

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

energy efficient air curtains technical data and controllers

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

STATIONARY HOT AIR HEATING SYSTEMS

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

Ceiling swirl diffusers

Units for suspended ceilings Type DID632

MANUAL Air curtain WRM06+ WRM08+ WRM10+ WRM12+

TECHNICAL SHEET. Road and residential lighting luminaire MATRIX-S-01 60LED. About the product MATRIX-S LED

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Ceiling swirl diffusers

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

TopVent Design Handbook

1.1 VTS: number 1 in the world pillars of success

Transformer oil coolers BETA & CETA

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Axial fans The right fan for every house

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

PLXSID1605. Warning HEAD OFFICE :

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

German Products Suitable for low energy / sustainable buildings

Specification Data. General:

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Engineering Data Book

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

250mm dia straight pipe length SP4 SP3. Air volume

MERIT SERIES Up Flow / Horizontal

Fan heater SWT Ceiling mounted fan heater with water heat

commercial & industrial electric space heating equipment & controls Electrical Wholesaler Product Guide Valid from 1st February 2011

Transcription:

ELECTRIC HEATING AND VENTILATION UNITS INTENDED USE The heating units with axial fans, metal casing and electric heaters are designed to heat rooms such as: industrial halls, workshops, warehouses, commercial pavilions, sports and entertainment halls etc. The heating and ventilation units are made through adding roof or wall intakes and intake boxes for establishing a mixing proportion of fresh and circulating air to heating units. The units are adapted to work in a horizontal position as ceiling units and in a vertical position as wall units. UNIT DESCRIPTION The unit includes: axial fan; electric heaters with spirally rolled aluminium finned tubes; external casing made of lacquered steel sheet; protection net made of galvanized steel sheet against accidental contact with heaters, options: single-row grid, slot ventilator or outlet nozzle. The casing variant with the following items is recommended to use with the units which are planned to be operated as ceilings ones: slot diffuser - for heating a zone of human presence by a secondary air stream; discharge cone - for increasing a range of supply air stream. At the client s request the units can be manufactured with casing and heaters made of stainless steel. DESIGNATIONS Heating and ventilation unit -27 -D Heating power Equipment 18, 27 kw single-row grid (K); slot diffuser (N); discharge cone (D);

TECHNICAL DATA Basic dimensions Size of unit FH-18 FH-27 Dimensions A 556 556 B 526 526 L 420 420 a 420 420 b 290 290 30 34 Unit s IP 30 30 Type of fan Technical details of fans FE-031EQ FE-035EQ Revolutions [rev/min] Voltage [V] Motor power [W] Current [A] Voltage [V] Power [kw] Current [A] At distance of 1m At distance of 5m 1400 1400 230 230 140 180 0,63 0,77 Technical deatils of heaters 400 400 18 27 27 39 Noise level db[a] 61 63 57 59 Noise level - sound pressure level at a distance of 1 and 5m taking account of directivity factor Q=2 and room absorption value A=50m 2. Heat output of units and air temperature rises Size of unit FH-18 FH-27 3 speed output data Air flow capacity [m 3 /h], heat output [kw], outlet air temperature rise [ o C] [m 3 /h] kw O C [m 3 /h] kw O C I 1400 6 8 1900 9 9 II 1600 12 17 2200 18 17 III 2100 18 25 2900 27 26 13

AUTOMATICS The units are powered at three-phase voltage 3~400V/50Hz. The units automation enables selection of heat output together with air flow capacity (depending on the unit s power 6/12/18kW, 9/18/27 kw). Additional automation elements (option): power and control box (AT) equipped with overcurrent circuit breakers, relays and contactors, signalling lamps, switches: AUTO STOP, 3-step power regulation and air flow capacity and HEATING VENTILATION. temperature regulator (RTA) for automatic change of heat output depending on the temperature in the room time programmer (ZG) for control of unit s operation in weekly mode. B - Supply and control box *S - Room temperature sensor - option with temperature regulator (RTA) **A - Air damper actuator - option with intake box Marking of unit s optional automation AT-RTA Supply and control box Additional elements AT temperature regulator (RTA) timer (ZG) regulator and timer (RTA + ZG) ADDITIONAL EQUIPMENT Additional equipment includes all elements specified in the data sheet of TERM units for TERM-1 sizes, such as: roof intake (CD), roof base (PD), wall intake (CS), intake boxes (SC), suspension elements (EZ, G, GW, GWt, WW, WWt) LISTING OF ADDITIONAL EQUIPMENT FOR UNIT (WALL MOUNT VERSION) 1- unit 2 - K-1 - flexible connector 3 - F-1 air filter 4 - SC-1 intake box 5 - CS-1 wall intake

OUTLET DIFFUSERS FOR THE UNITS Unit with single-row outlet grid (K) Slot diffuser (N) Discharge cone (D) Slot diffuser (N) A x B a x b Ln 555 x 525 355 x 355 100 Discharge cone(d) A x B c x d Ld 555 x 525 350 x 350 190 The units are supplied with the single-row grid as a standard. Grids have the movable blades enabling the air stream direction and reach adjustment. Ceiling units can be equipped with: slot diffusers (N) (air supply to 4 sides); discharge cone (D). Wall units can be also equipped with discharge cone (D). Slot diffusers are enabling heating people staying zones with the secondary air stream. Unit with slot diffuser can be suspended on the height max. 4m. Discharge cone enable increase of air supply range. CD ROOF INTAKE Roof intakes are intended to draw fresh air from above the roof and to protect the object against precipitations. If case of strong winds above 30m/s at the intake it s recommended to install additionally shields. In order to protect against pollution and insects the intakes have installed the nets on 2 sides (for CD-4 or the amount of outside air over 40% roof intake may be equipped with nets and shields on four sides. Air intakes are adapted for connecting with PD roof bases. Intake size A Lc C CD-1 520 580 728 20,0 s - net o - shield Roof bases are whole made of galvanized steel sheets. 15

PD ROOF BASE Roof bases are intended for installing cd roof air intakes and sc intake boxes of the term units Base size A Lc C PD-1 520 600 740 31 Roof bases are made of galvanized steel sheets. SC INTAKE BOXES FOR CEILING AND WALL HEATING-VENTILATING UNITS Basic version Version with additional elements: filter and circulating air dampers t - circulating air dampers f - filter Intake boxes are used to draw the mix the fresh and circulating air. In basic version they consist of: fresh air damper mixing chamber with circulating air inlet grids. For connection of the intake box to the unit it is necessary to use flexible connector (K) delivered as a optional equipment. Fresh air damper is operated with the actuator. Mixing chamber has 2 grids (manually adjusted) in the circulating air inlet holes enabling setting the participation of circulating air in total Air flow. Box size A Lm Lmax SC basic version SC version with filter and dampers SC-1 520 310 930 23 35 Intake boxes can be also have following additional elements: filter (F) class G3; circulating air dampers (P) with actuators. Inlet boxes with additional elements are made after agreement with the manufacturer. In agreement with the manufacturer intake boxes can be also made with the mixing chamber with one circulating air inlet grid. 16

CS WALL AIR INTAKE Wall air intakes are intended for drawing fresh air from outside of the wall. Intake size A CS-1 520 7 Wall intake vents are made of steel sheets protected with the paint coatings. ADDITIONAL EQUIPMENT MOUNTING SETS We can supply following mounting sets for the units: Mounting set type Heating function Heating and ventilating function Wall units Настенные агрегаты EZ hanging elements set Ceiling units Wall units Ceiling units EZ hanging elements set GW, GWt suspesion set or WW, WWt support set hanging on the threaded bars (heating function) Wall and ceiling units Set of elements for hanging the unit includes: angle bars mounted to the building partition 2 pcs; channel bars for hanging the unit - 6 pcs. Unit can operate in vertical position or inclined from plumb-line up to 20. EZ hanging elements set A B L Hmin TERM - E 470 620 990 180 17

(heating and ventilation function) Wall units GW suspension set - intake box without filter A B L 880 700 ~1315 1030 700 ~1575 CS - wall intake WW support set - intake box without filter A B L 880 560 ~930 WWt support set - intake box with filter 1030 560 ~930 CS - wall intake TERM 0; 1; 2 (heating and ventilation function) Ceiling units CD - roof intake PD - roof base c - ceiling tb - threaded bars A x B 620x290 18