Bringing a year round comfort solutions to extreme climates

Similar documents
Mitsubishi Electric's

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Full Product Lineup Catalogue CM13WD-K

Our Latest Technologies

AIR CONDITIONING SYSTEMS

Reuse Replace Renewal

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

TECHNICAL & SERVICE MANUAL

9001;2008 & , ADDENDUM

Unit Width. 900mm. Service Space Internal Header. 1st. Unit. 2nd. Coupling supplied as standard. Unit

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

PURY-M YNW-A (-BS) PURY-EM YNW-A (-BS)

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Increase your flexibility.

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

TECHNICAL & SERVICE MANUAL

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Variable Refrigerant Flow

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ELECTRICAL QUANTITY WEIGHT (LB)

Commercial High-Efficiency Condensing Units

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Submitted to Reference Approval Construction Unit Designation Schedule #

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

MODULAR CHILLER. R410a R22

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Submitted to Reference Approval Construction Unit Designation Schedule #

TECHNICAL SPECIFICATIONS

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

ROOFTOP PACKAGED AIR CONDITIONERS

Outstanding Performance; Application Flexibility

50TM TFF COMBINATION HEATING/COOLING UNITS

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Compact design & easy maintenance

Lennox Mini-Split Systems Year-Round Comfort and Performance

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

50TM COMBINATION HEATING/COOLING UNITS

VRV IV heat recovery Best efficiency and comfort solution

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Building Comfort Solutions

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

DAIKIN Modular Inverter Air Cooled Chiller

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

Air-Cooled Condensing Units with Compact Screw Compressors

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

NFZP Variable Refrigerant Flow Guide Specification

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Air Conditioner CONTENTS

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

LG VRF Systems. Air Conditioning Technologies

Air Conditioner SVC MANUAL(Exploded View)

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

AIR-CONDITIONER SERVICE MANUAL

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Digital Inverter 4 series 8 & 10HP

Building Comfort Solutions

PUHZ-SHW140YHA PUHZ-SHW230YKA

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM TWO-STAGE AIR CONDITIONER COMPONENTS WARRANTY COMPRESSOR CABINET COILS DESIGN

Highly Efficient,Powerful Heating and Cooling.

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

DC inverter VRF presentation

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

50A KP 70A KP 90A KP 120A KP 150A KP 210A

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

VariCool VAV Engineering Guide

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

3 rd Generation of VRV. The professional solution for your professional project

"SET-FREE" FXG. Technical Catalog

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Transcription:

ooling or Heating ZUBDN series PUHYHP YHM(BS) PUHYHP YSHM(BS) Bringing a year round comfort solutions to extreme climates ITY MULTI ZUBDN series combines the ultimate in application flexibility and powerful cooling and heating capabilities to deliver precise comfort even in the coldest days of the year down to 25. The technology behind this is a Flash Injection circuit which provides optimum amount of refrigerant to the system via a compressor through a specially designed injection port to ensure a particularly stable operation. With this, ZUBDN can provide a full heating performance even at 15 and continuous heating for up to 250 minutes in one continuous cycle, ensuring a phenomenal heating performance at low temperatures. Installation image Joint Header System Pipe Lengths [810HP] Refrigerant Piping Lengths Total length Maximum allowable length Farthest indoor from first branch Vertical differentials between units /outdoor (outdoor higher) /outdoor (outdoor lower) /indoor Maximum meters [Feet] 300 [984] 150 (175equivalent) [492 (574)] 40 [131] Maximum meters [Feet] 50 [164] 40 [131] 15 [49] Topbottom differential 50m [164ft] *1 unit Furthest piping length 175m [574ft] (equivalent length) (actual length 150m [492ft]) Between indoor units topbottom differential 15m [49ft] *1 When the outdoor unit is installed below the indoor unit, topbottom differential is 40m [131 ft]. Page 28

Stable Heating Performance even at 15 Full heating capacity even at 15 apacity improvement by about 30% () 50.0 25.0 PUHYHP400 YSHM Standard ITY MULTI PUHYP400 YSJM PUHYHP250 YHM Standard ITY MULTI PUHYP250 YJM 10.0 25 20 15 10 5 0 3 Outdoor temp. (W.B.) Using an industry first Flashinjection ircuit, the ZUBDN System is able to provide FULL heating performance in ambient temperatures as low as 15. Expanded Heating Operation down to 25 onventional ITY MULTI PUHYP YJM 20 Outdoor temperature Expanded to 25 Hyper ZUBDN Heating Inverter System System 25 Outdoor temperature 15.5 15.5 furthermore, from a previous LOWEST operating ambient temperature of 20, the ZUBDN System pushes the boundaries of technology to give heating in ambient temperatures as low as 25. 25 20 10 0 10 20 Outdoor temp. (W.B.) 25 With ZUBDN System Previously, heating performance drops off when the temperature falls below 20! however, even at such temperatures, the new ZUBDN System has no trouble keeping the occupants nice and toasty! Page 29

High Static Pressure Setting High Static Pressure Setting up to 60Pa is available. With our new ZUBDN model, high static pressure setting up to 60Pa is available by setting the dip switch (0Pa at factory setting) making it ideal and flexible for any type of application. Shorter Warmup in about 20 Min. With its new improved startup performance, the ZUBDN system achieves full heating capacity even when outdoor temperature is as low as 15. Heating capacity, about 20 minutes after startup is improved by 40% compared to the conventional model; ensuring occupants an immediate comfortable air solution. () 31.5 19 ZUBDN System Even at 15,it reaches the rated heating capacity in about 20minutes Stability apacity improvement by about 40% onventional ITY MULTI PUHYP YJM 0 0 20 10HP when the outdoor Time (minutes) temperature is 15 Heating capacity Reliable and Long Product Life ycle Backup Function (HP400 and HP500 models) ZUBDN system ensures an exceptionally high level of reliability by utilizing a new backup function, which can be easily operated in the case of a malfunction from an indoor unit remote controller. Backup operation Rotation Function (HP400 and HP500 models) Running outdoor units alternatively using its newly developed Rotation Function, the system is able to ensure an optimum product life cycle for both of its component units. lternate operation Page 30

Maximum Stable Operation By utilizing our advanced Flash Injection ircuit, the system can not only provide continuous heating for up to 250 minutes in one continuous cycle, but also significantly lessens defrost time to give an exceptionally stable heating operation. Heating up to 250 min. straight Reduced Defrosting time Startup omfort One of the key factors of the units newly designed Flash Injection ircuit is that the optimal amount of refrigerant can be provided to the system via the compressor through a specially designed injection port to ensure a particularly stable operation. In simple terms, the system allows a quick startup time and continuous heating; even in low ambient conditions. Flash Injection ircuit unit G F J B ompressor HI I H E' LEV 2 LEV 1 E D (confluence) ccumulator LEV Note: Heat Interchange ircuit (HI) Heating efficiency is improved by enhancing the recollection of heat at the outdoor unit with the low temperature refrigerant from the HI. Refrigerant is bypassed from injection port to the compressor onstant omfort With its new highly effective defrost feature (which prevents automatic defrosting when it is not required), the ZUBDN System can deliver conditioned heating operation up to 250 minutes in one continuous cycle! Heating capacity is maintained by the Flashinjection circuit. Heating efficiency improved by HI D F Discharged Pressure LEV E D Middle pressure E' F LEV 1 J Injection pressure I G LEV 2 H Suction pressure B Discharged pressure is maintained at high level. Secures sufficient refrigerant by Flashinjection circuit. [Pressure Enthalpy diagram showing HI] Page 31

OUTDOOR UNIT ZUBDN (Heat Pump) Series(Y) PUHYHP Y(S)HM(BS) Specifications Set name Power source ooling capacity (Nominal) Temp. range of cooling Heating capacity (Nominal) Temp. range of heating unit connectable Sound pressure level (measured in anechoic room) Diameter of Liquid pipe refrigerant pipe Gas pipe Model External finish External dimension H x W x D Net weight kg(lbs) Heat exchanger Type ompressor Starting method Motor output *3 m 3 /min ir flow rate L/s cfm FN Type x Quantity Motor output Protection devices Refrigerant Pipe between unit distributor Optional parts Power input urrent input EER Outdoor Power input urrent input OP Outdoor *1 *1 *2 *2 Total capacity Model/Quantity External static press. High pressure protection Inverter circuit (OMP./FN) ompressor Type x Original charge Liquid pipe Gas pipe BTU/h / W.B. D.B. BTU/h / D.B. W.B. db<> mm in. PUHYHP200YHM(BS) 22.4 76,400 6.40 10.810.29.8 3.50 25.0 85,300 6.52 11.010.410.0 3.83 P15~P250 / 1~17 56 ø12.7 (ø1/2) Brazed ø19.05 (ø3/4) Brazed Precoated galvanized steel sheets <MUNSELL 5Y 8/1 or similar> 1,710 (without legs 1,650) 673/8 (without legs 65) x 361/4 x 2915/16 220 (486) Saltresistant cross fin & copper tube Inverter scroll hermetic compressor Inverter PUHYHP250YHM(BS) PUHYHP400YSHM(BS) 3phase 4wire 380400415V 50/60Hz 28.0 45.0 95,500 153,500 9.06 12.86 15.214.514.0 21.720.619.8 3.09 3.49 15 ~ 24 (59 ~ 75 F) 5 ~ 43 (23 ~ 109 F) 31.5 107,500 8.94 15.014.313.8 3.52 15 ~ 27 (59 ~ 81 F) 25 ~ 15.5 (13 ~ 60 F) 50.0 170,600 13.35 22.521.420.6 3.74 PUHYHP500YSHM(BS) 56.0 191,100 18.16 30.629.128.0 3.08 63.0 215,000 18.04 30.428.927.8 3.49 50 ~ 130% of outdoor unit capacity P15 ~ P250 / 1 ~ 21 P15 ~ P250 / 1 ~ 34 P15 ~ P250 / 1 ~ 43 57 59 60 ø12.7 (ø1/2) Brazed ø15.88 (ø5/8) Brazed ø15.88 (ø5/8) Brazed ø22.2 (ø7/8) Brazed ø28.58 (ø11/8) Brazed ø28.58 (ø11/8) Brazed PUHYHP200YHM(BS) PUHYHP200YHM(BS) PUHYHP250YHM(BS) PUHYHP250YHM(BS) Precoated galvanized steel sheets <MUNSELL 5Y 8/1 or similar> 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) 1,710 (without legs 1,650) 673/8 (without legs 65) x 361/4 x 2915/16 220 (486) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Overheat protection, Overcurrent protection Overheat protection R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) Joint : MYY102SSG2 Header : MYY104/108/1010G 673/8 (without legs 65) 673/8 (without legs 65) 673/8 (without legs 65) 673/8 (without legs 65) x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 x 361/4 x 2915/16 220 (486) 220 (486) 220 (486) 220 (486) Saltresistant cross fin & copper tube Inverter scroll hermetic compressor Inverter High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Overheat protection, Overcurrent protection Overheat protection R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) R410 x 9.0kg (20 lbs) ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed ø9.52 (ø3/8) Brazed ø19.05 (ø3/4) Brazed ø19.05 (ø3/4) Brazed ø22.2 (ø7/8) Brazed ø22.2 (ø7/8) Brazed Outdoor Twinning kit : MYY100VBK2 Joint : MYY102SS/LSG2, MYY202SG2 Header : MYY104/108/1010G Notes: *1,*2 Nominal conditions Outdoor Pipe length Level difference ooling 27º DB/19º WB (81ºF DB/66ºF WB) 35º DB(95ºF DB) 7.5m (249/16ft.) 0m (0ft.) Heating 20º DB(68ºF DB) 7º DB/6º WB(45ºF DB/43ºF WB) 7.5m (249/16ft.) 0m (0ft.) *3 External static pressure option is available (30Pa, 60Pa / 3.1mmH2O, 6.1mmH2. *Nominal condition *1,*2 are subject to JIS B86151. *Due to continuing improvement, above speci cation may be subject to change without notice. Outdoor Unit Page 64