Similar documents
UL HAZARDOUS LOCATIONS SERVICES

Guide for hazardous areas

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Legislation associated with Hazardous Locations. Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Be safe be Ex

Overview of Hazardous Locations as They Relate to Solenoid Valves

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Understanding Hazardous Locations Concepts

Beamex. Calibration White Paper. Calibration in hazardous areas

SYSTEMS PRODUCT OVERVIEW

S T R I T T & P R I E B E I N C.

Beamex Calibration White Paper. Calibration in hazardous areas

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Electrical Grounding For Oil and Gas Applications

ATEX, NOMENCLATURE AND CODING

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

ATEX, NOMENCLATURE AND CODING

Notice of Proprietary Rights

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

INTERNATIONAL STANDARD

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Dual certification! Air handling units for potentially explosive atmospheres

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

NCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada

Inductive slot sensor

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Technical Data. General specifications. Rated operating distance s n 5 mm

OPTIBAR DP 7060 Supplementary Instructions

Gas Detection GAS BOOK.

Guide to Intrinsically Safe Portable Radios

A Guide to Safe Electronic Weighing in Hazardous Locations

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Intrinsically Safe Solutions

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

How Limit Switches Can Stop Machines from Going Boom

Relays for use in hazardous locations. Class I, Division 2 and ATEX

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Oil & Gas Industry. Magnecraft Relay Solutions

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Technical Data. Dimensions

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Why Wireless Gas Detection?

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger PIR 3000 Detection of flammable gases and vapours

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

Dräger X-am 5000 Multi-Gas Detection

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Explosion-protected network cameras Safety first

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Dräger Flame 2500 Flame Detection

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

Electrical solutions for oil and gas. De-risk by design.

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Hazardous Area Classifications and Protections

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Certified drive and control products for explosion protection

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Drive systems for the chemical, oil and gas industry. Electric drives and systems

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Hazardous area descriptions

INTRINSICALLY SAFE LIGHTING RANGE

standards: standards:

Intrinsically Safe or Explosionproof? Understanding the technology

Dräger X-am 2500 Multi-Gas Detection

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Explosion-proof Duct Heaters

Zareba Sensepoint Pro

GS01 (wireless) Detection of flammable gases and vapours

INSTRUCTION & SERVICE MANUAL

Dependable Solutions for Gas Detection

Explosion Protection Engineering Principles

ATEX Explained A brief Introduction

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

specifically for explosion prone areas can substantially reduce the risk of combustion.

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

Transcription:

Hazardous Location Surge Protection Solutions

Agenda PolyPhaser Transtector Market Leaders Hazardous Locations Class I Division 2 Qualifications and Definitions Impacts to Your Business Hazardous Applications Surge Protection Products and Solutions Professional Services

Surge Protection Experts PolyPhaser and Transtector Systems are industry leaders in the development, design and manufacturing of power and signal integrity solutions for the oil and gas industry. Our sales and engineering teams are versed in the specific challenges, requirement and specifications for this market. Coaxial RF Protection and Grounding Innovator of patented DC block and DC pass technology. Ultra low PIM design for next generation telecom applications. www.polyphaser.com AC DC and Data Line Protection Lead the industry with patented silicon diode (SASD) and metal oxide varistor (MOV) technology. Dedication to safety through global standards UL, FM, CE, RoHS, NEMA, IEC. www.transtector.com

Hazardous Locations A hazardous location is defined as a place where concentrations of flammable gases, vapors, or dusts occur. Electrical equipment that must be installed in such locations is especially designed and tested to ensure it does not initiate an explosion, due to arcing contacts or high surface temperature of equipment.

ANSI NFPA Area Descriptions Class Div locations qualifications Class I, Div. 1 - Where ignitable concentrations of flammable gases, vapors or liquids are present continuously or frequently within the atmosphere under normal operation conditions. Class I, Div. 2 - Where ignitable concentrations of flammable gases, vapors, or liquids are present within the atmosphere under abnormal operating conditions. Class II, Div. 1 - Where ignitable concentrations of combustible dusts are present within the atmosphere under normal operation conditions. Class II, Div. 2 - Where ignitable concentrations of combustible dust are present within the atmosphere under abnormal operating conditions. Class III, Div. 1 - Where easily ignitable fibers or materials producing combustible flyings are present within the atmosphere under normal operation conditions. Class III, Div. 2 - Where easily ignitable fibers or materials producing combustible flyings are present within the atmosphere under abnormal operating conditions

Equipment Protection Level The Equipment Protection Level (EPL) is specified for several kinds of protection. The required protection level is linked to the intended use in the zones described below Group Ex risk Zone EPL Minimum Type of Protection I (mines) energized Ma I (mines) de-energized in presence of Ex atmosphere Mb II (gas) explosive atmosphere > 1000 hrs/yr 0 Ga ia, ma II (gas) explosive atmosphere between 10 and 1000 hrs/yr 1 Gb ib, mb, px, py, e, o, q, s II (gas) explosive atmosphere between 1 and 10 hrs/yr 2 Gc n, ic, pz III (dust) explosive surface > 1000 hrs/yr 20 Da ia III (dust) explosive surface between 10 and 1000 hrs/yr 21 Db ib III (dust) explosive surface between 1 and 10 hrs/yr 22 Dc ic

Hazardous Locations Gas Station

Lightning Impacts to Your Business Lightning accounts for 61% of the accidents initiated by natural events. In North America16 out of 20 accidents involving petroleum products storage tanks were due to lighting strikes. (Journal of Hazardous Materials). Downstream costs due to lightning, fire and explosion --$95,000,000 Texas Refinery Louisiana Refinery $104,000,000 Rhineland-Palatinate Petroleum $68,800,000 Alberta Oil Sands $1,070,000,000, Singapore Refinery $153,000,000. Twelve miners killed by lightning-caused methane gas explosion (west Virginia 2005) Lightning strikes the earth 25 million times a year, with an estimated $5 billion in annual loss. The National Lightning Safety Institute has reported that US lightning costs and losses may exceed $8-$10 billion per year. (Accurate information is elusive or in error: US Dept Commerce reports lightning property damage at $48 million!). Global warming and climate change will increase lightning activity according to NASA. Indirect lightning strikes can induce voltages and currents into near by electrical lines.

Hazardous Applications Surge protection devices are commonly deployed in numerous applications in the oil and gas sector, thus reducing economic risk due to downtime, lost revenue and equipment replacement. SCADA Pump Jack Pipeline Compressor Stations Refining E&P (Exploration & Productions) Offshore Rigs Pipeline Metering Stations Motor Control Centers Fracturing Wellheads and Gathering Fields Pumping and Storage Transportation

Hazardous Product Solutions Application Network Component Surge Protection Required SCADA Transmitters, Sensors, RTUs, PLCs, Telecom Backhaul RF, AC, DC, Data Exploration & Production Drilling, Logging, Communications and Signaling Equipment RF, AC, DC, Data Offshore Drilling Communications, signaling, satellite, drilling, and logging equipment RF, AC, DC, Data Wellheads and Gathering Fields Communications and Signaling Equipment RF, DC, Data Compressor Stations Power, Communication, Signaling, and Measurement Equipment AC, DC, Data Pipeline Metering Stations Transmitters, Sensors, RTUs, PLCs, Communications RF, AC, DC, Data Storage Transmitters, Sensors, AC, DC, Data Refining Power, Communication, Signaling, and Measurement Equipment RF, AD, DC, Data Security Access Control and Security Cameras Data

Class I Div 2 Surge Protection datasheet

Class I Div 2 Surge Protection datasheet

Hazardous Product Solutions AC Protection IEP Series I2R SA Series APEX IMAX MCP DC Protection DRDC Series DRI Series DC Defender Series Data Protection ALPU Series PDS1 CPX Series TSJ Series RF Protection Certs not required TSX Series IS-B50LN-C2 AL-LSXM_MA Brochure

Committed to Service Meeting our customers requirements is paramount to our effort in creating highly satisfied customers. We are the only surge protection supplier that offers a full line of personal services, including: Consulting and Site Audits: More than 30 years of expertise and professional experience in power and grounding consulting, site audits and educational courses for oil and gas customers worldwide. Custom-Engineered Solutions: Experts in transient technology and standards required for Class I Div 2, ATEX, CSAQ, UL and CE. Tailored Product Expedite (TPE Program): Designed to provide application-specific surge protection solutions, through modification or enhancement of a current product. Technical Support: Global engineering services teams available to answer application questions, troubleshoot, or assist in the design and development of a custom solution. Customer Service: Dedicated inside sales and customer service teams trained in the unique surge protection requirements for energy markets.

Summary Hazardous locations: definitions and classifications for each hazardous location. Impacts to your business: strain on network infrastructure surge protection provides insurance to keep networks up and running as well as protects critical electronics. Class I Div 2 and hazardous product portfolio: AC, DC, Data Line and RF certified and specked in products to meet your project needs and applications. Our commitment to you: PolyPhaser Transtector provide solutions that reach beyond surge protection to support your business needs and reduce costly downtime. Resource: Contact your Tessco expert today to place an order or request further brochure and marketing material to discuss further with your key decision makers.

Our Mission To provide power management and protection for mission critical systems. Our Promise to You Innovative Solutions Reliable Products Attentive Customer Service We are here to assist you in finding the right solution for your needs. Contact Information Mark Hendricks Applications Engineer Tel:+1 208 762 6063 Email: mark.hendricks@smithspower.com www.smithspower.com www.polyphaser.com www.transtector.com