danfoss Heating Solutions 5

Similar documents
Installation and User Guide eco Intelligent Radiator Thermostat

Installation and User Guide living connect Electronic Radiator Thermostat

ECL Comfort 210 / 296 / 310

living connect, Electronic Radiator Thermostat

CS027 User Instructions

Drayton Digistat +3RF

Operating your heating system with the Prefect PRE5701 Programable Thermostat

C-Stat 17-ZW User Instructions

Danfoss Eco Electronic radiator thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

RF Programmable Room Thermostat User Instructions

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Installation & User s Instructions

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Model: Touch-RF. 1 Wireless Series

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Overview - Danfoss Link and living software versions

AUTO CM CM USER GUIDE

Elegance. SMT-700 User manual. Ver

Installation Guide. ECL Comfort 210, application A Table of Contents

Instruction FH-CWP Thermostat

User Manual THR870CUK Programmable Thermostat

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Danfoss ECO. The easy way to Smart Heating

Model: Slimline-B. Battery Series

INSTALLATION INSTRUCTIONS

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

Rotex Underfloor Heating User Guide

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

4 Wiring Brochure Wiring and

CT2800 Programmable Thermostat

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Model: Slimline-RF. 1 Slimline Series

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Modulating clock thermostat

- Data Brochure tekmarnet 4 Thermostat 542e

3 Channel Multi-Purpose Programmer User Instructions

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Operating Instructions

Floor sensor (NTC) Temp (C o ) Value (kohm) 10 o C 19,9 kohm 15 o C 15,7 kohm 20 o C 12,5 kohm 25 o C 10,0 kohm 30 o C 8,0 kohm

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

ES3247B. 3 Channel Programmer. User and Installation Instructions

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

User Manual. Universal Programmable Smart Wi-Fi Thermostat. For Systems Up to 3 Heat / 2 Cool with Wireless Humidity Control*

EFET 535. Installation Manual INT INT

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Read all instructions before proceeding. Store this manual for future reference

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Installation and user manual

Overview - Danfoss Link and living software versions

irad Wireless Controller

MagicStat CT3300 Programmable Thermostat

Model: Touch-RS. 1 Touch-RS

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Basic Plus2 Room Thermostats Floor Heating

Evolution Control. Zone Control Homeowner s Guide

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

Universal Programmable Wireless Thermostat Kit. See Wireless Setup Guide for Wireless Setup Instructions Read all instructions before proceeding

ECL Comfort 110, application 130

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

User Manual THR872CUK Wireless Programmable Thermostat

ECL Comfort 110, application 116

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

User s Manual

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

User Guide for EHE & EHE Programmable Room Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

installation guide digital timer thermostat

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Roth Touchline. German quality since Quick and easy user manual 1/10

Operating Instructions

Operating manual. Radiator Thermostat ETKF+

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

Weather compensated flow temperature control of heating and boiler systems

Underfloor Heating Programmable Thermostat

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Control solutions Biofloor

User Guide Y9420H Sundial RF 2 Pack 2

Operating Instructions

Model: Available in : Sapphire Black and Glacier White. 1 Series

Heating Controller SDC Remote Heating Controller DHC

USER'S OPERATING INSTRUCTIONS

Transcription:

4. Technical settings...22 4.1 Deactivating automatic daylight saving time...22 4.2 Adjusting to radiator/room...23 4.3 Deactivating intelligent control...23 4.4 Technical specifications...24 5. Safety precautions...25 6. Removing living eco...25 7. Disposal...25 UK For further information, please see www.danfoss.com/ living danfoss Heating Solutions 5

UK 1. Installation 1.1 Preparation living eco is supplied with adapters for Danfoss RA valves and valves with M30x1.5 (K) connections, two alkaline AA batteries and a 2 mm Allen key. Inserting the batteries Remove the battery cover and insert the two batteries. Make sure the batteries are correctly oriented. Setting the time and date when you start using living eco Once the batteries are installed The time will flash on the display - 23:59. Set the time Set hours using and press Set min. using and press Set date Set date using and press Format: day/month/year (DD/MM/ YYYY). Confirm setting When flashes, press to confirm. 6 living eco

1. Installation 1.2 Installing living eco M must be flashing on the display prior to installing. If not, see installation mode on page 19. UK 1. Start by mounting the adapter. RA K 2. Tighten RA adapter using the Allen key. Hand-tighten K adapter (max. 5 Nm). 2 mm Key 3. Screw the thermostat onto the adapter and tighten by hand (max. 5 Nm). 4. Press for approx. 3 seconds to enter the function. 5. A small M flashes, press to fix the thermostat. danfoss Heating Solutions 7

UK 2. Getting started... 2.1 Thermostat display The black dashed circle on the display shows a 24- hour dial. The black segments represent periods of comfort temperature, 21 C (default setting), and the 'empty' segments represent setback periods, where the temperature is 17 C (default setting). The display also shows the set temperature and current program. 24-hour dial Half hour segments Shows the program the thermostat is running (e.g. P1). Programmed temperature Battery symbol Setback period 22:30-06:00 hrs 17⁰C Weekday Flashes at the current time 2.2 Thermostat buttons The thermostat has two arrow buttons which allow you to navigate the display, s and set the temperature. Use to select and confirm. 8 living eco

2. Getting started... 2.3 Display symbols Symbols flash when they can be activated. PROGRAMME MENU P 0 Programme with no automatic temperature reduction maintains a constant temperature all day and night. You select the temperature. P 1 Saving which lowers the temperature to 17⁰C at night (22:30-06:00 hrs). Saving is configurable. P 2 Extended saving which lowers the temperature to 17⁰C at night (22:30-06:00 hrs), and during the day on weekdays (08:00-16:00 hrs). Saving is configurable. Travel which lowers the temperature when you are away. You select the period and the temperature. UK FUNCTION MENU M MAX MIN Installation mode (see page 19) Child lock Set the max and min temperature range Set time and date Back Confirm selection OTHER SYMBOLS Battery symbol (indicates low battery) Period setting for the travel danfoss Heating Solutions 9

UK 3. More features... 3.1 Adjusting the temperature Set the desired temperature by pressing. Default setting is 21 C. This also allows the temperature to be changed temporarily during a setback period, without having to change the program or period. If the comfort temperature is changed, e.g. from 21 C to 22 C, living eco will remember this change, and the comfort temperature will remain 22 C after the next setback period. 3.2 Frost protection, 6⁰C This symbol is displayed if you set the thermostat to its lowest setting. This means that the thermostat will maintain a constant temperature of 6⁰C in the room, ensuring frost protection. 10 living eco

3. More features... 3.3 Programmes When you start using the thermostat it is set to use program P1. You can select the which best matches your family's requirements. UK P0 - constant temperature of 21 C all day and night. P1 - one setback period at 17 C every night from 22:30-06:00 hrs P2 - two setback periods at 17 C every night from 22:30-06:00 hrs and all weekdays from 08:00-16:00 hrs 3.4 ing the If the display is off, press Then press briefly to open the. ing the (P0, P1 or P2) Switch between s using using Confirm setting When flashes, press to confirm. danfoss Heating Solutions 11

UK 3. More features... 3.5 Adjusting the setback period in P1 or P2 The thermostat default setting is one setback period for P1 and two setback periods for P2. You can adjust the setback periods so they match your family's requirements. NB - when living eco is set to change from 17 C to 21 C, e.g. at 06.00 hrs, the thermostat will learn when to start heating in order for the temperature to reach 21 C at 06.00 hrs. If the display is off, press to activate. Then press briefly to open the. (P1 or P2) Press to highlight the desired. When the flashes, press to select it. Weekdays for setback period Mo Tu We Th Fr Sa Su Monday Tuesday Wednesday Thursday Friday Saturday Sunday You can select to adjust the setback period for the weekend, all weekdays, or a single day. Use to select the desired period. When the desired period flashes, press to select it. (continues on next page) 12 living eco

3. More features... Setback period interval You are using to move around the 24-hour dial. For example when moving from one setback period to the next setback period. start stop 00:00_06:00 Use to move between the start and stop times. The time flashes slowly when it can be selected. time using Once the time has been selected it flashes faster to indicate it can now be adjusted. Set the start and stop time using Once the time is chosen, confirm using UK Change temp. if required Confirm setback period The temperature now flashes. Set the temperature using. Once the desired temperature is chosen, confirm using now flashes. (If you do not wish to change the setback period, press so that the symbol flashes, and then select using. You will be returned to the weekdays for setback period selection.) Press period. flashes. Press. to approve the entire setback to run the selected danfoss Heating Solutions 13

UK 3. More features... 3.6 Deleting a setback period You can delete a setback period by minimising it to half an hour. All segments on the timer dial will then become black. In this example Example the setback period is Monday, 08.30-16.00 hrs. To cancel the setback period, set the start time to 15.30 hrs. (P1 or P2) setback period If the display is off, press to activate. Then briefly press to open the. Press to highlight the desired. When the flashes, press to select it. Cycle through the weekdays using When the day(s) you wish to change flashes, press. Cycle through the 24- hour dial using. When the start of the setback period you wish to delete flashes slowly, press to select it. Clear setback period interval Use to set the start time so the setback period is half an hour. Once you have changed the start time, press Confirm now flashes. Press to approve. You deletion have now deleted the setback period. 14 living eco

3. More features... 3.7 Creating a new setback period in P1 or P2 living eco also allows you to create your own setback periods in P1 or P2. You can create up to three setback periods each day. If the display is off, press to activate. Then briefly press to open the. UK (P1 or P2) Weekdays for setback period Press to highlight the desired. When the flashes, press to select it. Mo Tu We Th Fr Sa Su Monday Tuesday Wednesday Thursday Friday Saturday Sunday You can select to adjust the setback period for the weekend, all weekdays, or a single day. Use to find the desired period. When the desired period flashes, press to select it. Setback period interval To add another setback period, use to move around the 24-hour dial to find and select the new start time. Disregard existing setback periods, just move ahead with to choose your new setback period. Confirm the start time by pressing danfoss Heating Solutions 15

UK 3. More features... The stop time now flashes. Set the stop time using. Once the time is chosen, confirm using Change temp. if required Confirm setback period The temperature now flashes. Set the temperature using, and confirm using continues flashing. (If you do not wish to create a new setback period, press so that the symbol flashes, and then select using. You will be returned to the weekdays for setback period selection.) Press to approve the entire setback period. 3.8 Travel The travel helps you save energy by reducing the temperature when you are away from home. Simply enter the period of time you will be away, and living eco will ensure your normal operating is resumed when you return, so you arrive into a warm house. If the display is off, press to activate. Then briefly press to open the. 16 living eco

3. More features... Set departure date by pressing until the suitcase flashes. using Set departure date using UK Set return date Change temp. if required Set return date using Press to change the temperature (default setting is 17 C). Confirm setting When flashes, press to confirm. is now displayed. Early return: When the departure date arrives, the following is displayed:, set period and temperature. If the display is off, press to activate. Then briefly press to open the. (P0/P1/P2) using danfoss Heating Solutions 17

UK 3. More features... Changing an existing travel period: Change travel period Change temp. if required If the display is off, press to activate Press briefly to open. by pressing until the suitcase flashes. using by pressing until the clock flashes. using Change the period by pressing using Press to change the temperature. Confirm setting Cancelling set travel period: If the display is off, press to activate. Then briefly press to open the. by pressing until the suitcase flashes. using off off using, confirm using 18 living eco

3. More features... 3.9 Function M MAX MIN FUNCTION MENU Installation mode. Always activate installation mode when installing/removing the thermostat. The thermostat may be irreparably damaged if not in the correct position during installation. Child lock - allows the buttons to be locked so your settings cannot be changed. Temperature limit - allows you to change the thermostat's temperature range, so you decide what the max and min temperature should be. This is useful, for example, in rooms with public access. Set time and date - allows the time and date to be changed after the thermostat is in use. UK 3.10 Installation mode function Press and hold for 3 sec. Activate installation mode Deactivate installation mode M using M flashes, select using Now a large M is flashing in the display. The mode is activated and living eco can be mounted. Press and hold for 3 sec. M flashes, press to deactivate. danfoss Heating Solutions 19

UK 3. More features... 3.11 Temperature limit function Press and hold for 3 sec. max/min max/min using. Press Set the max and min temperature using. Press to approve. 3.12 Setting the time function Press and hold for 3 sec. clock t using. Press Set time and date using and confirm using The thermostat automatically changes to/from daylight saving time. 3.13 Child lock function Press and hold for 3 sec. Activate child lock Deactivate child lock using Press The child lock is now activated. Deactivate the child lock by pressing all three buttons ( ) simultaneously for at least 5 sec. 20 living eco

3. More features... 3.14 Replacing the batteries Remove the battery cover and insert two alkaline AA batteries. Make sure the batteries are correctly oriented. UK Rechargeable batteries may not be used. Programme settings are preserved. Time and date settings are reset after 2 minutes and must then be re-entered. 3.15 Open window function If the thermostat detects a dramatic drop in temperature, for example due to an open window, it reacts by shutting off the heat. The thermostat returns to its original setting after half an hour, or when the window is closed. 3.16 Reset to factory settings Remove the battery cover and take out one battery. Press and hold for approx. 5 seconds, while reinserting the battery. danfoss Heating Solutions 21

UK 4. Technical settings 4. Technical settings ds Pb Fo Or ADVANCED MENU Deactivate/activate automatic daylight saving time Adjust to radiator/room Deactivate/activate intelligent control (forecast) Information about horizontal or vertical orientation (0 = horizontal, 90 = vertical) 4.1 Deactivating automatic daylight saving time Deactivate automatic change to/from daylight saving time as follows: function Press and hold flashes. for 3 sec. advanced ds Deactivate feature Press both buttons 3 sec. ds by pressing 1flashes Press, 0 flashes. for approx. 1= automatic daylight saving time (default setting) 0= no automatic change 22 living eco

4. Technical settings 4.2 Adjusting to radiator/room 2 is the factory setting. 1 is used if the radiator appears oversized for the room. 3 is used if the radiator appears undersized for the room. function Press and hold for 3 sec. flashes. advanced Pb Press both buttons 3 sec. Pb by pressing adjustment 1, 2 or 3 using The frequency of heat adjustment varies for 1, 2 and 3. for approx. 4.3 Deactivating intelligent control The thermostat's intelligent control (forecast) ensures that the desired temperature is reached by a given time. function Press and hold for 3 sec. flashes. advanced Press both buttons 3 sec. for approx. Fo Fo by pressing 1 flashes. Deactivate 0 using, confirm using forecast 1 = forecast is activated (default setting). 0 = forecast is deactivated danfoss Heating Solutions 23 UK

UK 4. Technical settings 4.4 Technical specifications Actuator type Electromechanical Software classification A Automatic action Type 1 Recommended use Residential (pollution degree 2) Open window function Yes Mechanical strength 70 N (max. force from valve) Maximum water temperature 90 C Movement type Linear Battery life 2 years Spindle movement 2-3 mm on the valve Maximum extension 4.5 mm Frequency Measures temp. every minute Speed of adjustment 1 mm/s Power supply 2x1.5V AA alkaline, class III (SELV) Power consumption 3 mw in standby, 1.2W in active state Operating temperature 0 to 40 C Transportation temp. range -20 to 65 C Temperature setting range 6 to 28 C Time keeping accuracy +/- 10 min/year Clock setting accuracy +/- 1 min Size (mm) L: 91 Ø: 51 (RA) Ball pressure test 75 C Weight 177 g (RA) IP class* 20 *The thermostat should not be used in hazardous installations or in places where it may be exposed to water. 24 living eco