FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

Similar documents
FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

P/N _F NSF Certified June 2010

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FG-L Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

PWEE Technical Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

RLNIE with INNOVATOR II

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

RL with INNOVATOR II No Heat Doors

RM with INNOVATOR Doors

RMN with INNOVATOR Doors Technical Data Sheet

RLT with INNOVATOR Doors

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Nosing Heater. Return Grill Heater

Engineering Plan Views

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

LifeLine Premier RLNIE

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

LWU Technical Data Sheet

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RL with INNOVATOR Doors

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

NFW, NCW, NFWG, NCWG, NFWE, NCWE

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Installation & Service Manual

Installation & Service Manual

Installation & Service Manual

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

Medium Temperature Bulk Produce and Bakery Merchandisers

BCH Medium Temperature Merchandisers

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

F-6 Multi-deck Frozen Food Wall Merchandisers

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

MD Medium Temperature Self Contained Open Vertical Merchandisers

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Reach-in Merchandisers

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Self-Contained MERCHANDISERS. February

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

Installation & Service Manual

Service Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

RFLNS, RFMNS & RFLTM Freedom Line

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

Self-Contained MERCHANDISERS. October

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

SERIES NAV S Display Merchandisers

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

Service Merchandisers

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

RFLN & RFMN Freedom Line

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Ultra Low Front Rear Load Medium Temperature

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

EcoVision Door Manual

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

Glass Doors, Hinged Bottom Mounts

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

SM / SN Medium and Low Temperature Spot Merchandisers

Field Top Mounted Condensing Unit

Cabinet & Merchandiser Price List

Installation & Service Manual

Transcription:

FWG C D E F J Technical Data Sheet NSF Certified December 2008 E G I A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. H B Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 4W Standard Fan Assembly (1) 0392457 Fan Motor, Evaporator (MO.4410101) 0464847 Fan Blade (FB.4780649) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0464847 Fan Blade (FB.4780649) B. Optional Adjustable Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Front/Electric Defrost only) (CT.4440611) D. 0398558 Defrost Termination Thermostat (3) (Rear/Electric Defrost only) (CT.4481088) E. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) HEATERS F. 208V Evaporator Defrost Heaters (5) 0481864 4 ft case (HE.4850637) 0444057 6 ft case (HE.4850620) 0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571) Item Part # Description Wiring Item # HEATERS (CONTINUED) G. 208V Drip Pan Defrost Heaters, Electric (6) 0481865 4 ft case (HE.4850638) 0444300 6 ft case (HE.4850609) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572) Drip Pan Defrost Heaters, Koolgas (7) 0488967 4 ft case (HE.4850641) 0465906 6 ft case (HE.4850628) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623) H. Nosing Anti-sweat Heaters (8) 0495009 4 ft case (HE.4850687) 0495006 6 ft case (HE.4850684) 0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686) I. Return Grille Anti-sweat Heaters (9) 0495013 4 ft case (HE.4850691) 0495010 6 ft case (HE.4850688 ) 0495011 8 ft case (HE.4850689) 0495012 12 ft case (HE.4850690) J. Return Glass Anti-sweat Heaters (10) 0481867 4 ft case (GL.4978594) 0474775 6 ft case (GL.4977903) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839) Note: Revision G adds note on reduced energy load with optional energy efficient motors (Page 3). 2008 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

Engineering Plan Views Wide Island PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Dimensions shown as inches & (mm). 10-2004 64 1 /2 (1638) Electrical Field Connection 41 1 /2 (1054) 8 1 /2 (217) Waste Electrical Stub Up Area 6 x 6 (152 x 152) Wireway Waste A B 26 1 /2 (673) D 43 7 /8 (1114) 4 1 /4 (108) Splashguard FRONT 4 3 /4 (120) 29 1 /2 (750) C Refrigeration Waste 41 1 /2 (1054) Waste (12 Ft shown) Splashguard 2 of 7 FWG Technical Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 10 1 /4 (261) 12 1 /8 (307) 4 1 /2 (115) 8 (203) 15 3 /4 (400) 20 3 /4 (529) 59 3 /4 (1515) 70 1 /4 (1784) 72 (1829) 80 5 /8 (2046) 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 1 /4 (1226) 73 3 /4 (1874) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 2 in. (51 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 80 5 /8 (2046) 80 5 /8 (2046) 80 5 /8 (2046) 80 5 /8 (2046) Back of case to front of splashguard 72 (1829) 72 (1829) 72 (1829) 72 (1829) Back of case to O/S edge of front leg 59 3 /4 (1515) 59 3 /4 (1515) 59 3 /4 (1515) 59 3 /4 (1515) Distance between edges of external legs and center legs NA 30 1 /4 (768) 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA NA NA 43 7 /8 (1114) Distance between front legs and splashguard 12 3 /8 (312) 12 3 /8 (312) 12 3 /8 (312) 12 3 /8 (312) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 36 1 /8 (918) 61 5 /8 (1565) 84 1 /4 (2140) 132 3 /8 (3363) Back of case to center of stub up area 64 1 /2 (1638) 64 1 /2 (1638) 64 1 /2 (1638) 64 1 /2 (1638) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 40 1 /2 (1029) 67 1 /2 (1715) 90 1 /8 (2289) 138 1 /4 (3511) Waste s (One each end) (D) RH End of case to the center of LH waste outlet 36 1 /8 (918) 61 5 /8 (1565) 84 1 /4 (2140) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 70 1 /4 (1784) 70 1 /4 (1784) 70 1 /4 (1784) 70 1 /4 (1784) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) Refrigeration Back of case to center of front refrigeration outlet 64 7 /8 (1646) 64 7 /8 (1646) 64 7 /8 (1646) 64 7 /8 (1646) Back of case to center of rear refrigeration outlet 15 3 /4 (400) 15 3 /4 (400) 15 3 /4 (400) 15 3 /4 (400) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)

Wide Island Display with Glass Walls FWG 9 7 /8 (251) 35 7 /8 (910) Dimensions shown as inches & (mm). 15 7 /8 (404) 33 (838) 24 3 /8 (618) COIL FAN FAN COIL 3 1 /8 (79) 5 1 /2 (140) 59 3 /4 (1517) 4 (101) Case-to-Case Connection Refrigeration 1 1 /2 (37) 3 1 /4 (82) NSF Certification This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. 11 3 /4 (299) 68 7 /8 (1747) 80 5 /8 (2046) REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. MED FF IC Discharge Air ( F) +24 12 22 Evaporator( F) +19 20 30 Unit Sizing ( F) +17 23 33 Btu/hr/ft * MED FF IC Parallel 440 625 670 Conventional 460 650 700 *Optional energy efficient motors reduce the refrigeration load by 27 Btu/hr/ft (4 ft and 8 ft models) and 18 Btu/hr/ft (12 ft models). DEFROST DATA MED FF IC Frequency (hr) 24 24 24 Defrost Water (lb/ft/day) 2.2 2.1 1.8 (± 15% based on case configuration and product loading). ELECTRIC MED FF IC Temp Term ( F) 48 48 48 Failsafe (minutes) 60 60 60 GAS Duration (minutes) NA 15 18 OFFTIME Impact Excel FWG Not Recommended Standard Defrost Thermostat Close on rise: close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO ** MED +22 F / +10 F FF 17 F / 29 F IC 27 F / 39 F Indoor Unit Only, Pressure Defrost Termination** Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge (lb)*** 4 ft 1.7 6 ft 2.1 8 ft 2.5 12 ft 3.7 ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 7

Impact Excel FWG Electrical Data 4 ft 6 ft 8 ft 12 ft Number of Fans 4W Evaporator 2 2 4 4 Amperes Watts 4 ft 6 ft 8 ft 12 ft 4 ft 8 ft 12 ft Evaporator Fans 60Hz Standard 0.62 0.62 1.24 1.24 48 48 96 96 50Hz Standard 0.76 0.76 1.52 1.52 54 54 108 108 230V 60Hz Export 0.30 0.30 0.60 0.60 48 48 96 96 230V 50Hz Export 0.36 0.36 0.72 0.72 54 54 108 108 60Hz Energy Efficient 0.24 0.24 0.48 0.48 16 16 32 32 230V 60Hz Energy Efficient 0.12 0.12 0.24 0.24 16 16 32 32 Anti-sweat Heaters (on fan circuit) 50/60Hz Standard 0.87 1.30 1.74 2.60 104 156 208 312 230V 50/60Hz Export 0.45 0.68 0.90 1.36 104 156 208 312 Minimum Circuit Ampacity 60Hz Standard 1.69 2.12 3.18 4.04 50Hz Standard 1.83 2.26 3.46 4.32 230V 60Hz Export 0.95 1.18 1.70 2.16 230V 50Hz Export 1.01 1.24 1.82 2.28 60Hz Energy Efficient 1.31 1.74 2.42 3.28 230V 60Hz Energy Efficient 0.77 1.00 1.34 1.80 Maximum Over Current Protection 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Return Glass Anti-sweat Heaters 50/60Hz Standard 0.08 0.13 0.16 0.22 10 15 18 26 230V 50/60Hz Export 0.04 0.07 0.08 0.12 10 15 18 26 208V Electric Defrost 8.75 13.07 15.38 23.07 1820 2720 3200 4800 230V Export Electric Defrost 7.91 11.83 13.91 20.87 1820 2720 3200 4800 Koolgas Defrost 2.50 2.67 3.33 6.66 300 320 400 800 Standard Lighting None 4 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWG Technical Data Sheet

Impact Excel FWG Product Data Recommended Usable Cube 1 (Cu Ft/Ft) 7.28 ft 3 /ft (0.68 m 3 /m) ARI Total Display Area 2 (Sq Ft/Ft) 6.20 ft 2 /ft (1.89 m 2 /m) Shelf Area 3 (Sq Ft/Ft) 5.50 ft 2 /ft (1.68 m 2 /m) 1 ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using ARI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE. ESTIMATED SHIPPING WEIGHT 5 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 1000 (454) 1200 (544) 1400 (635) 1600 (726) 75 (34) 5 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 7

Electric Defrost Standard NEUTRAL POWER 1 8 9 4 Ft - 2 Fans 8 Ft - 4 Fans 12 Ft - 4 Fans 1 8 9 Fans Nosing Anti-sweat Heater Return Grille Anti-sweat Heater 2 Refrigeration Thermostat (Optional) Light Blue To } Condensing Unit L1 208 V Power From Defrost Contactors L2 3 Defrost Termination Thermostat } To Condensing Unit 6 Drip Pan Heater 5 Electric Defrost Heaters Return Glass Anti-sweat Heater Purple White 10 6 Drip Pan Heater 5 Purple 10 White Electric Defrost Heaters POWER NEUTRAL WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers. 6 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWG Technical Data Sheet

Gas Defrost Optional Drip Pan Heater Koolgas Only 7 7 4 Heater Switch 4 Heater Switch POWER NEUTRAL POWER NEUTRAL WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Numbers = Parts List Item Numbers Grayed components in 12 foot models only. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 7