Sigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)

Similar documents
Intelligent Security & Fire Ltd

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

User Operation Manual

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Intelligent Security & Fire Ltd

Operation and Maintenance Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

An introduction to... Sigma

SECURIT 700L USER MANUAL

SYSTEM 5000 USER MANUAL

Conventional Fire Alarm System 2014 V1.2

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Control Panels and Fire Detection Equipment

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

user manual Document No , Revision 03 November 2015

Conventional Fire Control Panel with Extinguishant Control Unit. Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU

U ser's Guide PC6010

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

SALES SUPPORT DOCUMENT

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Installation, Operating and Maintenance Manual

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Carbon Monoxide Transmitter

EP203. User Manual and. Approved Document No. DFU Rev 1

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Control Panel User Guide (TO BE RETAINED BY THE USER)

USER MANUAL & MAINTENANCE GUIDE OG OO

Control Panel User Guide

Control Panel User Guide

ZSC100 Gas Detection and Alarm System Controller

Fire detection and alarm system Operating instructions

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Intelligent Security & Fire Ltd

Racal-Guardall. Countess. User Instructions. Countess

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Application, Installation, Operation & Maintenance Manual

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM


USER GUIDE. Security Control Panels INS046-7

Conventional Fire Control Panel

Excel-EN Conventional Fire Control Panel

5 Sounds and Indications

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

ORION Mini-Rep INSTALLATION MANUAL

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Fire Alarm Control Panel. System Maintenance and Log Book

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

AXS Strikemaster Engineering Manual

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

FiRe mobile-2 Operation Manual

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

CAREL IR33+ CONTROLLER

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Sigma XT+ Extinguishant Control Panel. Operation and Maintenance Manual

User Operation Guide Document: VI49.2

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

HILLS Series LED Code Pad User Manual

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

GAS SUPRESSION CONTROL PANEL:

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up

EDW500 / EDW503. Electronic Controls for Dishwashers

Salamander User Guide

System 800 Addressable Fire Detection & Alarm System

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Scantronic Leading the way in security

WARNING FIRE DOOR CLOSING

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

USER MANUAL CEF AP28 CONTROL PANEL

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

LED (CLASSIC) DECK OVEN

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Reflective Optical Beam Smoke Detector User Guide

HARDWIRED CONTROL PANELS

Transcription:

Sigma XT Extinguishant Control Panel (K11031M2, K11031F2) User Manual Man-1091 Issue 03 October 2009

Fire alarm condition General fire indicator lights and zonal fire indicators flash. Buzzer sounds urgently. Carry out fire procedure. Fault condition General fault indicator lights and specific fault indicators flash. Buzzer sounds continuously. Call maintenance engineer. Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 2 of 10

Disabled condition General disablement indicator and specific fault indicator lit continuously. Maintain vigilance during disablement conditions. Test condition Test indicator and specific fault indicator lit continuously. Ensure system is returned to normal when testing is finished. Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 3 of 10

Manual only mode Manual only indicator lit Extinguishant will not be released by automatic detection. Automatic and Manual mode Automatic and Manual indicator lit Extinguishant will be released by automatic detection. Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 4 of 10

1 st Stage activated Normally accompanied by a zonal fire indicator. If no zonal fire indicator and Release imminent indicator is lit then a manual release button has been activated. 1 st stage of automatic release of extinguishant has started. Release Imminent Always accompanied by 1 st stage activated indicator. Normally accompanied by more than one zonal fire indicator. Countdown timer to extinguishant release has started. Time remaining before release indicated in seconds on seven segment display. If no zone fire LEDs lit then release is by manual unit. Extinguishant will be released when timer reaches zero, display will show EEE during extinguishant release. Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 5 of 10

How To Test lamps Do This Display Comments Buzzer sounds whilst button is pressed Silence buzzer Lamp test All lamps on Alarm/ Fault warning silenced Enable buttons Alarm/Fault warning silence Enable control Buzzer beeps twice every seven seconds Insert key and turn Silence alarms Alarm/Fault Buzzer Silenced Silence/Sound Alarm Sound alarms Silence/Sound Alarm Fire Buzzer beeps urgently Reset Reset All fault indicators flash for 3 seconds Resets fire detection system. Extinguishant system will reset only after the extinguishant has been released Disable a zone step 1 Disable a zone step 2 till d1 displayed First display Disable a zone step 3 Select to scroll zones Zone 2 Fire in Zone General Disablement 1 2 3 Zone/Fault/Test/ Disablement Dot flashes when disabled Zone 2 fault LED lit How To Do This Display Comments Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 6 of 10

Put a zone into test mode step 1 Put a zone into test mode step 2 till t1 displayed First display Put a zone into test mode step 3 Select to scroll zones Zone 2 Fire in Zone Test mode on 1 2 3 Zone/Fault/Test/ Disablement Dot flashes when disabled Zone 2 fault LED lit Enable a zone step 1 Enable a zone step 2 till d1 displayed First display Disabled zones will have flashing dot. Enable a zone step 3 Select to scroll zones Zone 2 Fire in Zone 1 2 3 Zone/Fault/Test/ Disablement Zone fault LED off Dot stops flashing when enabled Exit test mode step 1 Exit test mode step 2 First display Zones in test mode will have flashing dot Exit test mode step 3 Select Press to scroll zones Zone 2 Fire in Zone 1 2 3 Zone/Fault/Test/ Disablement Zone 1 fault LED off Dot stops flashing when test mode exited Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 7 of 10

How To Change from Manual only to Automatic and Manual and vice versa Do This Display Comments Automatic and manual Manual only Automatic and manual Manual only Start Extract fan Insert key and turn Enable control Press button till Ac appears in display Insert key and turn Press button again to turn extract fan on Press button again to turn extract fan off Manually release the extinguishant CAUTION EXTINGUISHANT RELEASE PULL DOWN-PUSH BUTTON Dot flashes to indicate extract active. extractive inactive Extinguishant will release after time displayed in seconds on the countdown timer Disable extinguishant control step 1 Pull down flap and press button to release extinguishant Disable extinguishant control step 2 Enable extinguishant control step 1 de is displayed Dot flashes to indicate extinguishant control is disabled Flashing dot indicates extinguishant control disabled Enable extinguishant control step 2 de is displayed extinguishant control enabled Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 8 of 10

How To Disable manual release step 1 Do This Display Comments Disable manual release step 1 dt is displayed Dot flashes to indicate Manual release is disabled Enable Manual release step 1 Flashing dot indicates Manual release disabled Enable Manual release step 2 dt is displayed Manual release enabled Disable extract fan step 1 Press butto n Disable extract fan step 2 dc is displayed Dot flashes to indicate Extract fan is disabled Enable extract fan step 1 Press butto n Flashing dot indicates extract fan disabled Enable extract fan step 2 dc is displayed Extract fan enabled Disable first stage relay output step 1 Disable first stage relay output step 2 dp is displayed Dot flashes to indicate first stage relay output is disabled Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 9 of 10

How To Enable first stage relay output step 1 Do This Display Comments Flashing dot indicates first stage relay output disabled Enable first stage relay output step 2 Disable second stage relay output step 1 dp is displayed first stage relay output enabled Disable second stage relay output step 2 Enable second stage relay output step 1 da is displayed Dot flashes to indicate second stage relay output is disabled Flashing dot indicates second stage relay output disabled Enable second stage relay output step 2 Disable first stage sounders step 1 dp is displayed second stage relay output enabled Disable first stage sounders step 1 db is displayed Dot flashes to indicate first stage sounders are disabled Enable first stage sounders step 1 Flashing dot indicates first stage sounders disabled Enable first stage sounders step 2 db is displayed first stage sounders enabled Product Manuals/Man-1091_Sigma XT_User_Manual_02 Page 10 of 10