GMS9/GCS9 SERIES 93% AFUE

Similar documents
GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GKS9 40" 90% Gas Furnaces

TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Rheem Classic Series Multi-position Gas Furnaces

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

MULTI POSITION GAS FURNACE

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Upflow/Horizontal Condensing, Gas-Fired Furnace

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Ruud Achiever Plus Series Multi-position Gas Furnaces

Multi-Position Gas Furnaces

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

MULTI POSITION GAS FURNACE

G6RC Series TECHNICAL SPECIFICATIONS

Ruud Achiever Series Multi position Gas Furnaces

Downflow/Horizontal Right Induced Draft Gas Furnace

Rheem Classic Plus Series Multi position Gas Furnaces

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

MERIT SERIES Downflow

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Wt. Lbs Model Number (BTUH) Hz

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Cooling Capacity CFM in. w.c. (125 Pa)

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Cooling Capacity CFM range

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

FG7T (C and L Series)

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

13 GEP A L P - 1 A

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Multi-Position Gas Furnaces

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Ruud Acheiver Series Upflow Gas Furnaces

Transcription:

GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility. Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel recuperative coil for maximum efficiency Designed for multi-position installation GMS9: upflow, hor i zon tal right or left; GCS9: downflow, horizontal right or left Energy-saving, reliable Hot Surface Ignition system, featuring a Norton Mini-Igniter with patented adaptive learning algorithm to maximize igniter life Aluminized-steel inshot burners Energy-saving PSC, multi-speed, direct drive blower motor Quiet, corrosion-resistant induced draft blower assembly Integrated furnace control with improved diagnostics Low voltage terminal blocks Multiple flame roll-out switches, blower door safety switch, outlet air-limit switch and pressure switch for proof of combustion air 40VA transformer for heating and air conditioning control service Combination redundant gas valve and regulator Top venting is standard; alternate flue/vent located on right side Completely assembled, factory run-tested furnace for heating or combination heating/cooling application All models comply with California NOx Standards Suitable for direct vent (2-pipe) or non-direct vent (1-pipe) applications Cabinet Construction Heavy-gauge, reinforced, fully insulated steel cabinet with durable baked-enamel finish Attractive architectural gray paint finish Foil-face insulation-lined heat exchanger compartment Coil and furnace fit flush for easy installation Convenient left or right connection for gas and electric service Bottom or side air inlet (GMS9) Removable, solid-bottom block-off (GMS9) Accessories L.P. Conversion Kit (LPT-00A) L.P. Gas Low Pressure Kit (LPLP01) High Altitude Natural Gas/L.P. Kits (HANG11, HANG12, HALP10) High Altitude Pressure Switch Kit (HAPS27) External Filter Rack (EFR01) Horizontal Concentric Vent Kit (HCVK) Vertical Concentric Vent Kit (VCVK) Internal Filter Retention Kit upflow, horizontal (RF000180) Internal Filter Retention Kit downflow (RF000181) Thermostats Blower Motors (CHT18-60, CH70TG, CHSATG, H20TWR) SS-377D www.goodmanmfg.com 1/05 Supercedes 6/04

Nomenclature G M S 8 070 3 A N A Goodman Brand Air Flow Direction M: Upflow/Horizontal D: Dedicated Downflow C: Downflow/Horizontal H: Hi Air Flow Description S: Single Stage/Multi-speed V: Two Stage/Variable-speed Cabinet Width A: 14 B: 17½ C: 21 D: 24½ NOx N: Natural Gas X: Low NOx Revision A: Initial Release B: 1 st Revision C: 2 nd Revision AFUE 8: 80% 9: 90% Maximum CFM @ 0.5 ESP 3: 1,200 4: 1,600 5: 2,000 KBTUH 045: 45,000 070: 70,000 090: 90,000 115: 115,000 140: 140,000 2

Performance Ratings Natural Gas Output Heating Capacity BTUH Tons AC @ Temperature AFUE² Input 1 BTUH Natural LP 0.5 ESP Rise Range ( F) GMS90453BXA 46,000 42,800 37,200 93.0 3.0 35-65 GMS90703BXA 69,000 64,400 55,800 93.0 3.0 35-65 GMS90904CXA 92,000 86,000 74,400 93.0 4.0 35-65 GMS91155DXA 115,000 106,500 93,000 93.0 5.0 35-65 GCS90453BXA 46,000 42,800 37,200 93.0 3.0 35-65 GCS90703BXA 69,000 64,400 55,800 93.0 3.0 35-65 GCS90904CXA 92,000 86,000 74,400 93.0 4.0 40-70 GCS91155DXA 115,000 106,500 93,000 93.0 5.0 40-70 ¹ For altitudes above 2,000, reduce input rating 4% for each 1,000 above sea level. ² DOE AFUE based upon Isolated Combustion System (ICS). Specifications Circulator Blower Filter Size (in 2 ) Minimum Maximum Shipping Vent No. of Circuit Overcurrent Size Weight HP Speed Diameter¹ Burners Permanent Disposable Ampacity 2 Protection 3 (D x W) (pounds) (amps) (amps) GMS90453BXA 10 x 7 1/3 4 2 2 288 576 9.0 15 132 GMS90703BXA 10 x 8 1/3 4 2 3 282 564 9.0 15 135 GMS90904CXA 10 x 10 1/2 4 2 4 376 752 8.9 15 158 GMS91155DXA 11 x 10 3/4 4 2 5 470 940 12.2 15 175 GCS90453BXA 10 x 7 1/3 4 2 2 288 576 9.0 15 132 GCS90703BXA 10 x 8 1/3 4 2 3 282 564 9.0 15 135 GCS90904CXA 10 x 10 1/2 4 2 4 376 752 8.9 15 156 GCS91155DXA 11 x 10 3/4 4 2 5 470 940 12.2 15 175 ¹ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. ² Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. ³ Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size. All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply. Gas Service Connection ½ FPT Important: It is required to size overcurrent protection device and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 3

GMS9 Dimensions AIR 28 3/4 3/4 3/4 19 5/8 2 1/2 AIR INTAKE PIPE 2" PVC A B ( AIR) C 3/4 2 1/16 VENT/FLUE PIPE 2" PVC AIR 1 1/2 14 GAS SUPPLY HOLE 7 3/8 HIGH VOLTAGE LEFT SIDE DRAIN LINE HOLES 23 DRAIN TRAP CL LOW VOLTAGE SIDE CUT-OUT 30 1/4 2 5/8 21 1/4 19 3/16 1 40 CONDENSATE DRAIN TRAP w/ 3/4" PVC (RIGHT OR LEFT SIDE) 2 16 5/8 30 1/4 32 13/16 27 1/8 2 11/16 4 1/8 24 9/16 2 5/8 19 3/16 1 6 1/8 DRAIN TRAP CL AIR INTAKE LOCATION STANDARD GAS SUPPLY HOLE VENT/FLUE LOCATION HIGH VOLTAGE RIGHT SIDE DRAIN LINE HOLES LOW VOLTAGE SIDE CUT-OUT 1 23 9/16 BOTTOM KNOCK-OUT D BOTTOM KNOCK-OUT LEFT SIDE FRONT RIGHT SIDE A B C D GMS90453BXA GMS90703BXA 17½ 16 12⅜ 13⅝ GMS90904CXA 21 19½ 16⅜ 17½ GMS91155DXA 24½ 23 20⅜ 20⅞ 1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. 2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace. 3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. 4. Installer must supply following gas line fittings, according to which entrance is used: Left Two 90º elbows, one close nipple, straight pipe Right Straight pipe to reach gas valve Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0 0 3 C 0 1 Horizontal 6 0 3 C 0 4 C = If placed on combustible floor, the floor MUST be wood ONLY. For servicing or cleaning, a 36 front clearance is recommended. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed below. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. 4

GCS9 Dimensions LEFT SIDE FRONT RIGHT SIDE 28 3/4 3/4 19 5/8 2 1/2 AIR INTAKE PIPE 2" PVC 3/4 A B (RETURN AIR) 3/4 2 1/16 VENT/FLUE PIPE 2" PVC LOW VOLTAGE 40 CONDENSATE DRAIN TRAP w/ 3/4" PVC (RIGHT OR LEFT SIDE) LOW VOLTAGE HIGH VOLTAGE HIGH VOLTAGE LEFT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP CL 2 5/8 4 1/8 11 1/2 9 13/16 15 1/2 28 5/16 2 8 1/4 28 5/16 19 7/8 18 13/16 14 6 1/8 2 11/16 11 5/8 9 3/4 7 3/8 VENT/FLUE LOCATION AIR INTAKE LOCATION DRAIN 2 5/8 TRAP CL RIGHT SIDE DRAIN LINE HOLES GAS SUPPLY HOLE 18 5/8 UNFOLDED FLANGES 20 5/32 FOLDED FLANGES AIR D UNFOLDED FLANGES E FOLDED FLANGES AIR AIR A B C D E GCS90453BXA 17½ 16 12⅜ 14½ 16 GCS90703BXA 17½ 16 12⅜ 14½ 16 GCS90904CXA 21 19½ 16⅜ 18 19½ GCS91155DXA 24½ 23 20⅜ 21½ 23 1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. 2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace. 3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. 4. Installer must supply following gas line fittings, according to which entrance is used: Left Two 90º elbows, one close nipple, straight pipe Right Straight pipe to reach gas valve Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0 0 1 NC 0 1 Horizontal 6 0 1 C 0 4 C = Combustible: If placed on combustible floor, the floor MUST be wood ONLY. NC = Non-Combustible: A combustible floor subbase must be used for installation on combustible flooring For servicing or cleaning, a 36 front clearance is recommended. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed below. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. 5

GMS9 Blower Performance Specifications GMS90453BXA GMS90703BXA GMS90904CXA GMS1155DXA Motor Speed Tons AC at 0.5 ESP CFM & Temperature Rise vs. External Static Pressure External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM HIGH 3.0 1,352 29 1,318 30 1,260 31 1,202 33 1,128 35 1,044 955 853 MED 2.5 1,214 32 1,172 34 1,123 35 1,064 37 1,012 39 938 859 741 MED-LO 2.0 997 40 994 40 960 41 923 43 884 45 817 741 611 LOW 1.5 757 52 753 52 734 54 704 56 674 59 620 524 438 HIGH 3.0 1,449 41 1,409 42 1,326 45 1,273 47 1,201 49 1,194 1,136 1,018 MED 2.5 1,192 50 1,172 51 1,141 52 1,094 54 1,046 57 973 904 793 MED-LO 2.0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1.5 750 79 730 81 714 83 692 86 657 90 620 570 502 HIGH 4.0 1,970 40 1,874 42 1,757 45 1,667 48 1,566 51 1,431 1,334 1,182 MED 3.5 1,713 46 1,650 48 1,572 50 1,510 52 1,418 56 1,313 1,211 1,079 MED-LO 3.0 1,439 55 1,412 56 1,370 58 1,327 60 1,260 63 1,166 1,078 956 LOW 2.5 1,183 67 1,155 69 1,122 71 1,108 72 1,062 75 1,011 931 816 HIGH 5.0 2,134 46 2,103 47 2,029 48 1,941 51 1,906 51 1,818 1,733 1,625 MED 4.0 1,678 58 1,643 60 1,643 60 1,577 62 1,527 64 1,489 1,423 1,339 MED-LO 3.5 1,453 68 1,440 68 1,426 69 1,363 72 1,349 73 1,314 1,253 1,205 LOW 3.0 1,259 78 1,239 79 1,220 80 1,181 83 1,159 85 1,118 1,082 1,015 1. CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium speed heating. Installer must adjust blower cooling & heating speed as needed. 3. For most jobs, about 400 CFM per ton when cooling is desirable. 4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. 6. The dashed (----) areas indicate a temperature rise not recommended for this model. 7. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 6

GCS9 Blower Performance Specifications GCS90453BXA GCS90703BXA GCS90904CXA GCS1155DXA Motor Speed Tons AC at 0.5 ESP CFM & Temperature Rise vs. External Static Pressure External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM HIGH 3.0 1,352 29 1,318 30 1,260 31 1,202 33 1,128 35 1,044 955 853 MED 2.5 1,214 32 1,172 34 1,123 35 1,064 37 1,012 39 938 859 741 MED-LO 2.0 997 40 994 40 960 41 923 43 884 45 817 741 611 LOW 1.5 757 52 753 52 734 54 704 56 674 59 620 524 438 HIGH 3.0 1,449 41 1,409 42 1,326 45 1,273 47 1,201 49 1,194 1,136 1,018 MED 2.5 1,192 50 1,172 51 1,141 52 1,094 54 1,046 57 973 904 793 MED-LO 2.0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1.5 750 79 730 81 714 83 692 86 657 90 620 570 502 HIGH 4.0 1,970 40 1,874 42 1,757 45 1,667 48 1,566 51 1,431 1,334 1,182 MED 3.5 1,713 46 1,650 48 1,572 50 1,510 52 1,418 56 1,313 1,211 1,079 MED-LO 3.0 1,439 55 1,412 56 1,370 58 1,327 60 1,260 63 1,166 1,078 956 LOW 2.5 1,183 67 1,155 69 1,122 71 1,108 72 1,062 75 1,011 931 816 HIGH 5.0 2,134 46 2,103 47 2,029 48 1,941 51 1,906 51 1,818 1,733 1,625 MED 4.0 1,678 58 1,643 60 1,643 60 1,577 62 1,527 64 1,489 1,423 1,339 MED-LO 3.5 1,453 68 1,440 68 1,426 69 1,363 72 1,349 73 1,314 1,253 1,205 LOW 3.0 1,259 78 1,239 79 1,220 80 1,181 83 1,159 85 1,118 1,082 1,015 1. CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium speed heating. Installer must adjust blower cooling & heating speed as needed. 3. For most jobs, about 400 CFM per ton when cooling is desirable. 4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. 6. The dashed (----) areas indicate a temperature rise not recommended for this model. 7. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 7

Accessories Description G_S90453BXA G_S90703BXA G_S90904CXA G_S91155DXA LPT-00A L.P. Conversion Kit LPLP01 L.P. Gas Low Pressure Kit HANG11 High Altitude Natural Gas Kit 1 1 1 1 HANG12 High Altitude Natural Gas Kit 2 2 2 2 HALP10 High Altitude L.P. Gas Kit 3 3 3 3 HAPS27 High Altitude Pressure Switch Kit 3 3 3 3 EFR01 External Filter Rack DCVK-20 Horizontal/Vertical Concentric Vent Kit (2 ) DCVK-30 Horizontal/Vertical Concentric Vent Kit (3 ) Available for this model (1) 7,001 to 9,000 (2) 9,001 to 11,000 (3) 7,001 to 11,000 Note: All installations above 7,000 require a pressure switch change. For installation in Canada, furnaces are certified only to 4,500. Downflow Floor Base: When the GCS9 model is installed directly on a wood floor, a downflow floor base must be used. Those model numbers are: CFB17, CFB21 and CFB24. Thermostats CHT18-60 CH70TG CHSATG H20TWR Description Cooling/Heating, Mechanical Cooling/Heating, Digital, Non-programmable Cooling/Heating, Mechanical Heating Only, Mechanical Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright 2005 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. Goodman brand products are made proudly in the USA. 8