Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Similar documents
Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGAPULS 64

Safety instructions VEGABAR 81, 82, 83, 86, 87

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

OPTIBAR DP 7060 Supplementary Instructions

Safety instructions VEGAMIP MPR61(*).G*/DK****R/T*** VEGAMIP MPT61(*).G*/DK****T*** VEGAMIP MPR62(*).G******R/T*** IECEx BVS Ex t IIIC T..

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

OPTIBAR P 1010/2010 C Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions

Safety instructions VEGAPULS 62

Safety instructions Display and adjustment module

Annubar Flowmeter Series

User s Manual YTA610 and YTA710 NEPSI Certification

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

IECEx Certificate of Conformity

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

EU DECLARATION OF CONFORMITY

Manufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Technical Data. Dimensions

Operating Instructions Edition 02/2007

Safety instructions VEGATOR 121, 122

OPTIWAVE X500 Supplementary Instructions

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

IECEx Certificate of Conformity

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

Technologies, Solutions, and Applications. Radiation-based Level

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

ProcessMaster, HygienicMaster FEX300, FEX500

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

SET Installation and Operating Instructions. Level switch for one sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

PEPPERL+FUCHS GmbH

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

Intrinsically Safe Solutions

IECEx Certificate of Conformity

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Instrumentation Products and Applications

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

SET-2000 Oil/Sludge 12 VDC

Technical Data. Dimensions

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

OilSET-1000 (12 VDC)

Indoor/outdoor resistance thermometer Model TR60

Safety instructions VEGAVIB 61, 62, 63

Supplementary instructions Bypass 72 Bypass tube with VEGAFLEX level sensor

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Radiation-based measurement Detectors

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Assembly. Host Sub-D Alarm

Product Information to the manual

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Technical Data. Dimensions

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Installationsmanual GWSL1100/2100, GWML3100

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Technical Data. Dimensions

SET-2000 Hi Level/Oil

Manual Power relay SR853

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Tank Gauging System Special Safety Instruction

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

SEK-3 Marine Grounding System

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Safety instructions VEGAPULS 69

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Temperature measurement with SITRANS T siemens.com/processinstrumentation

INTERNATIONAL STANDARD

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Temperature Measurement Transmitters for field mounting

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Rosemount 3144P Rosemount 3144P Temperature Transmitter

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Manual Isolating Barrier D461R1 (Revision 01)

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

4) Intrinsic Safety Certification

Declaration of conformity

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Safety instructions VEGASWING 61, 63

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

PROTECT SRB 200EXi-1A

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

BA488CF Intrinsically safe Panel mounting Fieldbus Display

Model 144H. Product Data Sheet , Rev DB February Content

Quick Start Guide For the

Transcription:

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675

Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments 3 2.2 Zone 20/21 instruments 3 2.3 Zone 21 instruments 3 3 Technical data 4 3.1 Electrical data 4 4 Application conditions 5 4.1 Permissible ambient temperatures 5 4.2 Max. surface temperature 6 4.3 Permissible process pressure on the sensor 6 4.4 Protection rating 6 5 Cable entries 6 6 Installation, mounting 6 7 Grounding 6 8 Material resistance 6 9 Locking mechanism of housing cover 7 Please note: These safety instructions are part of the documentation: l VEGADIF 65-36236 - 4 20 ma - 36128-4 20 ma/hart - 36129 - Profibus PA - 36130 - Foundation Fieldbus l 37676 - IECEx certificate IECEx BVS 10.0008 2 VEGADIF DF65.GX*****H/Z/P/F*****

1 Area of applicability These safety instructions apply to the differential pressure transmitters series VEGADIF DF65. GX*****H/Z/P/F***** according to IECEx certificate IECEx BVS 10.008 (certificate number on the type label) and for all instruments with the number of the safety instruction (37675) on the type label. 2 General information The differential pressure transmitters series VEGADIF DF65.GX*****H/Z/P/F***** are used for monitoring or control also in areas with combustible, dust generating bulk solids. The VEGADIF DF65.GX*****H/Z/P/F***** consist of a differential pressure transmitter unit (sensor), a metal process connection element and a processing electronics in a metal housing. An indicating and adjustment module can be optionally mounted into VEGADIF DF65.GX*****H/Z/P/ F*****. The VEGADIF DF65.GX*****H/Z/P/F***** are suitable for use in hazardous atmospheres of all combustible dusts, for applications requiring instruments of category zone 20, zone 20/21 or zone 21. If the VEGADIF DF65.GX*****H/Z/P/F***** are installed and operated in hazardous areas, the general Ex installation regulations IEC 60079-14 as well as these safety instructions must be observed. The requirements of IEC 61241-1 e.g. with respect to dust and temperatures must be fulfilled. The operating instructions as well as the applicable, valid Ex mounting regulations and standards for electrical equipment must be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. 2.1 Zone 20 instruments The VEGADIF DF65.GX*****H/Z/P/F***** are installed in hazardous areas requiring instruments of zone 20. 2.2 Zone 20/21 instruments In applications as zone 20/21 instrument, VEGADIF DF65.GX*****H/Z/P/F***** are installed in the separating wall separating areas from each other in which zone 21 or zone 20 instruments are required. The electronics housing is in the hazardous area requiring a zone 21 instrument and the sensor is in the hazardous area requiring a zone 20 instrument. 2.3 Zone 21 instruments The VEGADIF DF65.GX*****H/Z/P/F***** are installed in hazardous areas requiring instruments of zone 21. VEGADIF DF65.GX*****H/Z/P/F***** 3

3 Technical data 3.1 Electrical data The VEGADIF DF65.GX*****H/Z/P/F***** with integrated electronics module DF60* have intrinsically safe circuits. These intrinsically safe circuits are connected to terminals located in the "Ex-i" connection compartment. VEGADIF DF65.GX*****H/Z***** Power supply and signal circuit: (terminals 1[+], 2[-] in electronics compartment; with double chamber housing version in connection compartment) In ignition protection type intrinsic safety Ex ia IIC For connection to a certified, intrinsically safe circuit. Maximum values: U i = 30 V I i = 131 ma P i = 983 mw The effective internal capacitance is C i = 5 nf. The effective internal inductance L i is negligibly small. VEGADF DF65.GX*****P/F***** Power supply and signal circuit: (terminals 1[+], 2[-] in electronics compartment; with double chamber housing version in connection compartment) In ignition protection type intrinsic safety Ex ia IIC/IIB for instruments of zone 0 resp. zone 1 and Ex ia IIC/ IIB resp. Ex ib IIC/IIB for instruments of zone 1. For connection to a certified, intrinsically safe circuit. Maximum values: U i = 17.5 V I i = 500 ma P i = 5.5 W The instrument is suitable for connection to a Fieldbus system according to the FISCO model (IEC 60079-27), e.g. Profibus PA or Foundation Fieldbus. or U i = 24 V I i = 250 ma P i = 1.2 W The effective internal capacitance is C i = 5 nf. The effective internal inductance L i is negligibly small. 4 VEGADIF DF65.GX*****H/Z/P/F*****

VEGADIF DF65.GX*****H/Z/P/F***** Indicating and adjustment circuit: (terminals 5, 6, 7, 8 in electronics compartment) Communication circuit: (I²C-BUS socket in electronics compartment; with double chamber housing version also in connection compartment) Circuit of the indicating and adjustment module: (spring contacts in the electronics compartment; with double chamber housing version also in the connection compartment) In ignition protection type intrinsic safety Ex ia IIC Only for connection to the intrinsically safe supply and signal cuitcuit of the corresponding external indicating and adjustment unit VEGADIS 61 (IECEx BVS 06.0014). The regulations for the interconnection of intrinsically safe circuits between VEGADIF DF65.GX*****H/Z/P/ F***** and the external indication unit are complied with if the total inductance and total capacity of the connection cable between VEGADIF DF65. GX*****H/Z/P/F***** and the external indication unit (L cable = 100 µh and C cable = 2.8 µf) are not exceeded. The indication and adjustment module integrated in VEGADIF DF65.GX*****H/Z/P/F***** and the connected interface converter are taken into account. In ignition protection type intrinsic safety Ex ia IIC Only for connection to the intrinsically safe signal circuit of an interface converter VEGACONNECT. In ignition protection type intrinsic safety Ex ia IIC Only for connection to the indicating and adjustment module PLICSCOM. With the double chamber housing version, the indicating and adjustment module may be mounted either in the electronics compartment or in the connection compartment. The intrinsically safe supply and signal circuit of VEGADIF DF65.GX*****H/Z/P/F***** is galvanically separated from parts that can be grounded. The metallic parts of the VEGADIF DF65.GX*****H/Z/P/F***** are electrically connected with the earth terminals. 4 Application conditions 4.1 Permissible ambient temperatures On the sensor, zone 20 or 21 VEGADIF DF65.GX*****H/Z/P/F***** -40 +120 C On the electronics housing, zone 20 or zone 21 VEGADIF DF65.GX*****H/Z/P/F***** -40 +60 C VEGADIF DF65.GX*****H/Z/P/F***** 5

4.2 Max. surface temperature On the sensor, zone 20 or 21 VEGADIF DF65.GX*****H/Z/P/F***** Process temperature +3 K On the electronics housing, zone 20 or zone 21 VEGADIF DF65.GX*****H/Z/P/F***** Process temperature +9 K 4.3 Permissible process pressure on the sensor The process pressure during operation in an explosive atmosphere requiring a zone 20 instrument must be between 0.8 1.1 bar. The permissible combinations of application pressure and application temperature are stated in the operating instructions. 4.4 Protection rating Housing protection rating, housing in zone 20 or zone 21: IP 66 Sensor in zone 20 or zone 21: IP 67/IP 68 5 Cable entries The cable entry sent with the delivery is suitable for the housing temperature range specified in the VEGADIF DF65.GX*****H/Z/P/F***** certificate. If a different cable entry is used, the separately certified cable entry/gland (according to ATEX) determines the max. permissible ambient temperature on the housing (max. values: -40 C, +98 C). 6 Installation, mounting The VEGADIF DF65.GX*****H/Z/P/F***** as zone 20, 20/21 instruments must be installed in a way that excludes contact between the sensor and the vessel wall, taking vessel installations and the bulk solid in the vessel into account. 7 Grounding The VEGADIF DF65.GX*****H/Z/P/F***** must be grounded, for example via the ground connection terminal. 8 Material resistance The VEGADIF DF65.GX*****H/Z/P/F***** must only be used in media against which the materials of the wetted parts are sufficiently resistant. 6 VEGADIF DF65.GX*****H/Z/P/F*****

9 Locking mechanism of housing cover With single-chamber housing versions, the lid must be screwed in to the stop and secured with the locking device before setup and use of VEGADIF DF65.GX*****H/Z/P/F***** in hazardous atmospheres. With double-chamber housing versions, the lid of the connection compartment and the lid of the electronics compartment must be screwed in to the stop and secured with the corresponding locking device before setup and use of VEGADIF DF65.GX*****H/Z/P/F***** in hazardous atmospheres. Single chamber housing 1 1 Locking screw of the cover 1 2 1 Clamp 2 Locking screw of the cover VEGADIF DF65.GX*****H/Z/P/F***** 7

Double chamber housing with "Ex-d" connection compartment 2 1 3 2 1 "Ex-i" connection compartment with electronics module 2 Locking screw of the cover 3 "Ex d" connection compartment with integrated barrier 8 VEGADIF DF65.GX*****H/Z/P/F*****

VEGADIF DF65.GX*****H/Z/P/F***** 9

10 VEGADIF DF65.GX*****H/Z/P/F*****

VEGADIF DF65.GX*****H/Z/P/F***** 11

VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com www.vega.com ISO 9001 VEGA Grieshaber KG, Schiltach/Germany 2010 Subject to change without prior notice