Air to Air Heat Exchanger

Similar documents
Digital Inverter 4 series 8 & 10HP

4-Way Cassette type. Contents MMU-AP 2H2UL

Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

Compact 4-way Cassette ( ) Type

SERVICE MANUAL. Air to Air Heat Exchanger. Concealed microcomputer control type VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE

250mm dia straight pipe length SP4 SP3. Air volume

Air to Air Heat Exchanger Installation Manual. Concealed microcomputer control type. Installation Manual 1 English. Installation Manual xx Xxxxx

ELECTRICAL QUANTITY WEIGHT (LB)

AIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Blending Commercial and Residential. MiNi VRF

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

DESIGN & TECHNICAL MANUAL

Engineering Data Book

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Engineering Data Book

Engineering Data Book

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

Engineering Data Book

DESIGN & TECHNICAL MANUAL

Engineering Data Book

DESIGN & TECHNICAL MANUAL

Simultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings

6. DUCT TYPE AR 60FUAK, AR 60UUAK

Heat and energy recovery ventilators

TABLE OF CONTENTS RMXS-E8V1B

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

DESIGN & TECHNICAL MANUAL

KOMFORT EC DB Suspended heat recovery air handling units

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

PRODUCT RANGE: ROOFTOP PACKAGE

DESIGN & TECHNICAL MANUAL

Air Conditioner SVC MANUAL(Exploded View)

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

DESIGN & TECHNICAL MANUAL

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

DESIGN & TECHNICAL MANUAL

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

Index. Toshiba Solutions. Absolute comfort

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

Highly Efficient,Powerful Heating and Cooling.

Engineering Data Book

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

[U] Serie MHB / MHA Manual de Ingeniería

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Heat Recovery Ventilation

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

DESIGN & TECHNICAL MANUAL

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit

Engineering. Super Heat Recovery Multi System

DESIGN & TECHNICAL MANUAL

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Multi-Path RTU-TYPE 2

PURY-P200YMF-C, PURY-P250YMF-C CONTENTS

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

PAJ3. Product Specifications

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Auxiliary Equipment and Accessories

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Single Fan MiNi VRF Apartment Ready

DESIGN & TECHNICAL MANUAL

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Heat Recovery Ventilator with DX Coil 0CED0-01A

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

technical data air conditioning systems Indoor Units FBQ-C7VEB

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

TABLE OF CONTENTS ERSQ-AAY1

Air Conditioning Technical Data RZASG-MV1

PHD3. Product Specifications

DESIGN & TECHNICAL MANUAL

DX Interface : Dx-Controller (0-10V type) Installation manual ENGLISH. TCB-IFDD1GUL Dx-Controller (0-10V type) Model name:

Air Conditioners. Technical Data FBQ-C

Heat Recovery Ventilator with DX Coil 0CED0-01B(Replaces: 0CED0-01A)

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

Energy Recovery Ventilator

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Side blow VRF. Engineering Data Book. Outdoor units E Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E

DESIGN & TECHNICAL MANUAL

Transcription:

Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications 2. Dimensions 3. Wiring diagram 4. Center of gravity 5. Electrical characteristics 6. Fan characteristics 7. Sound characteristics (NC curve)

1. Specifications Item Model VN-M1HE VN-M2HE VN-M3HE VN-MHE VN-M6HE VN-M8HE VN-M1HE VN-M1HE VN-M2HE Power supply (V) AirFlow (L/S) External static pressure (Pa) Power consumption (W) Sound pressure level (db(a)) Temperature Exchange Efficiency (%) Enthalpy Exchange Efficiency (%) Heating Cooling Dimension (Length x Width x Height) (mm) Weight (kg) Single phase 22-24V~Hz (Extra high) 41.7 69.4 97.2 138.9 18.6 222.2 277.8 416.7 555.6 41.7 69.4 97.2 138.9 18.6 222.2 277.8 416.7 555.6 3.6 43.1 58.3 18.3 144.4 194.4 29.7 333.3 388.9 (Extra high) 82-12 8-98 114-125 134-1 91-17 142-158 13-1 135-156 124-143 52-78 34-65 56-83 69-99 58-82 12-132 97-122 13-129 92-116 47-64 28-4 65-94 62-92 61-96 76-112 84-127 112-142 11-143 (Extra high) 68-78 123-138 165-182 214-238 262-29 36-383 532-569 751-786 184-1154 59-67 99-111 135-145 176-192 24-258 339-353 494-538 78-784 132-18 42-47 52-59 82-88 128-142 178-191 286-3 353-37 57-67 72-742 (Extra high) 26-28 1117 34-35 32.5-34 34-36 37-38.5 39.5-4.5 38-39 41-42.5 24-25.5 25-27 3-32 11472 33-34 35.5-37 38.5-4 36.5-37.5 39.5-41 2-22 21-22 27-29 26-29 31-32.5 33.5-35 34-35.5 36-37.5 37-38 (Extra high) 81.5 78 74.5 76.5 75 76.5 73.5 76.5 73.5 81.5 78 74.5 76.5 75 76.5 73.5 76.5 73.5 83 81.5 79.5 78 76.5 77.5 77 79 77.5 (Extra high) 74.5 7 65 72 69.5 71 68.5 71 68.5 74.5 7 65 72 69.5 71 68.5 71 68.5 76 74 71.5 73.5 71.5 71.5 71.5 73.5 72 (Extra high) 69.5 65 6.5 64.5 61.5 64 6.5 64 6.5 69.5 65 6.5 64.5 61.5 64 6.5 64 6.5 71 69 67 66.5 64 65.5 64.5 67 65.5 9 x 9 x 29 114 x 114 x 3 1189 x 1189 x 4 1189 x 1189 x 81 36 36 38 53 53 7 7 143 143 Duct Spigot Ø (mm) Ø1 Ø1 Ø1 Ø2 Indoor side: 4 off Ø2 spigots Outdoor side: 2 off 283x73 Filtration efficiency grade (%) Around unit Operating range Outdoor Air (OA) Return Air (RA) 82-1 C~4 C 8%RH or less -15 ~43 C 8%RH or less 5 C~4 C 8%RH or less 1. Air flow can be change between high (extra high) mode and low mode for both heat exchange mode and bypass mode 2. fan mode is set from factory, extra high fan mode can be set by hard wiring on fan coil PC board 3. Sound pressure level are measured 1.5m below the center of the unit, and within an anechoic chamber in accordance with JIS B8616. 2

2. Dimensions VN-M1HE Installation example Attention 1. Duct size (Nominal Diameter): ø1 2. The above dimensions do not include the thickness (5 mm) of the insulation material on the unit body. Attention 1. The two outdoor ducts (the Outdoor air Duct and the Exhaust air Duct) must be insulated to prevent condensation (Material: Glass wool, Thickness: 25 mm) 2. It is recommended that you use an electric damper together with the Air to Air Heat Exchanger, as wind may enter the room while the unit is not in operation in the cold or windy region. 3. As shown in the psychrometric chart, Point A is suction air condition in high temperature, Point B is discharge air condition in low temperature and Point C is the air condition that exchanged heat. If C is located at the left of the saturation curve as shown, it is dewed or frosted in the heat exchanger element of the unit. In this case to prevent the dew or frost, be sure to heat B up to B' for making C C'(right side of saturation curve). 3

VN-M2HE, VN-M3HE Installation example Attention 1. Duct size (Nominal Diameter): ø1 2. The above dimensions do not include the thickness (5 mm) of the insulation material on the unit body. Attention 1. The two outdoor ducts (the Outdoor air Duct and the Exhaust air Duct) must be insulated to prevent condensation (Material: Glass wool, Thickness: 25 mm) 2. It is recommended that you use an electric damper together with the Air to Air Heat Exchanger, as wind may enter the room while the unit is not in operation in the cold or windy region. 3. As shown in the psychrometric chart, Point A is suction air condition in high temperature, Point B is discharge air condition in low temperature and Point C is the air condition that exchanged heat. If C is located at the left of the saturation curve as shown, it is dewed or frosted in the heat exchanger element of the unit. In this case to prevent the dew or frost, be sure to heat B up to B' for making C C'(right side of saturation curve). 4

VN-MHE, VN-M6HE Installation example Attention 1. Duct size (Nominal Diameter): ø2 2. The above dimensions do not include the thickness (5 mm) of the insulation material on the unit body. Attention 1. The two outdoor ducts (the Outdoor air Duct and the Exhaust air Duct) must be insulated to prevent condensation (Material: Glass wool, Thickness: 25 mm) 2. It is recommended that you use an electric damper together with the Air to Air Heat Exchanger, as wind may enter the room while the unit is not in operation in the cold or windy region. 3. As shown in the psychrometric chart, Point A is suction air condition in high temperature, Point B is discharge air condition in low temperature and Point C is the air condition that exchanged heat. If C is located at the left of the saturation curve as shown, it is dewed or frosted in the heat exchanger element of the unit. In this case to prevent the dew or frost, be sure to heat B up to B' for making C C'(right side of saturation curve). 5

VN-M8HE, VN-M1HE Installation example Attention 1. Duct size (Nominal Diameter): ø2 2. The above dimensions do not include the thickness (5 mm) of the insulation material on the unit body. Attention 1. The two outdoor ducts (the Outdoor air Duct and the Exhaust air Duct) must be insulated to prevent condensation (Material: Glass wool, Thickness: 25 mm) 2. It is recommended that you use an electric damper together with the Air to Air Heat Exchanger, as wind may enter the room while the unit is not in operation in the cold or windy region. 3. As shown in the psychrometric chart, Point A is suction air condition in high temperature, Point B is discharge air condition in low temperature and Point C is the air condition that exchanged heat. If C is located at the left of the saturation curve as shown, it is dewed or frosted in the heat exchanger element of the unit. In this case to prevent the dew or frost, be sure to heat B up to B' for making C C'(right side of saturation curve). 6

VN-M1HE, VN-M2HE ~ Installation example Attention 1. Duct size (Nominal Diameter) Indoor side: ø2 Outdoor side: 283x73 2. The above dimensions do not include the thickness (5 mm) of the insulation material on the unit body. Attention 1. The two outdoor ducts (the Outdoor air Duct and the Exhaust air Duct) must be insulated to prevent condensation (Material: Glass wool, Thickness: 25 mm) 2. It is recommended that you use an electric damper together with the Air to Air Heat Exchanger, as wind may enter the room while the unit is not in operation in the cold or windy region. 3. As shown in the psychrometric chart, Point A is suction air condition in high temperature, Point B is discharge air condition in low temperature and Point C is the air condition that exchanged heat. If C is located at the left of the saturation curve as shown, it is dewed or frosted in the heat exchanger element of the unit. In this case to prevent the dew or frost, be sure to heat B up to B' for making C C'(right side of saturation curve). 7

3. Wiring diagram VN-M1HE, VN-M2HE, VN-M3HE, VN-MHE, VN-M6HE, VN-M8HE, VN-M1HE Code CN*** F1 FM1 FM2 DAM TRA Part name Connector Fuse Air supplying motor Air exhausting motor Damper motor TRA sensor Code TOA RY71, RY72 RY74, RT75 TB1 TB2 TB3 Part name TOA sensor Relay for air supplying motor Relay for air exhausting motor Terminal block (power supply) Terminal block (communication) Terminal block (external output) Code Part name SW31, SW71 SW72, SW73 DIP switch 43F11, 43F12 Relay for air supplying motor 43F21, 43F22 Relay for air exhausting motor 1. The dotted line represents a wire procured locally, and the dashed line represents an option sold separately. 2. represents a terminal block, represents a connection terminal, and represents a connector on the printed circuit board. 3. represents a protective earth. 4. represents a printed circuit board. 5. Using a no voltage a-contact input of the external input (Sold separately), the following operations are available: Between 1 and 2: Selecting the remote controller operation (Invalid/Valid) Between 1 and 3: Adjusting the ventilation fan speed (/) Between 1 and 4: Selecting the ventilation mode (Bypass mode/heat exchange mode) Between 1 and 5: Operation (ON/OFF) Use a microcurrent contact (DC12V, 1mA). In addition, ON/OFF operation is possible when using a voltage of DC12V or 24V. 6. Blue wire () is connected as factory default. To switch to Extra, connect black wire s connector instead of blue. 7. When the temperature of the outdoor air is below -1 C, the unit runs in the cold mode (the ventilator for air supply runs intermittently). The unit cannot run when the temperature of the outdoor air is below -15 C. The ventilator for air supply stops running and the ventilator for air exhaust also stops depending on the settings. 8. Even if Bypass mode is selected manually, the unit switches to Heat exchange mode automatically to prevent condensation when the temperature of the outdoor air is below 15 C. However, Bypass mode is still displayed. 8

VN-M1HE, VN-M2HE Code CN*** F1 FM1,FM3 FM2,FM4 DAM1,DAM2 TRA Part name Connector Fuse Air supplying motor Air exhausting motor Damper motor TRA sensor Code TOA RY71, RY72 RY74, RT75 TB1 TB2 TB3 Part name TOA sensor Relay for air supplying motor Relay for air exhausting motor Terminal block (power supply) Terminal block (communication) Terminal block (external output) Code TB4 SW31, SW71 SW72, SW73 Part name Terminal block DIP switch 43F11, 43F12 Relay for air supplying motor 43F21, 43F22 Relay for air exhausting motor 1. The dotted line represents a wire procured locally, and the dashed line represents an option sold separately. 2. represents a terminal block, represents a connection terminal, and represents a connector on the printed circuit board. 3. represents a protective earth. 4. represents a printed circuit board. 5. Using a no voltage a-contact input of the external input (Sold separately), the following operations are available: Between 1 and 2: Selecting the remote controller operation (Invalid/Valid) Between 1 and 3: Adjusting the ventilation fan speed (/) Between 1 and 4: Selecting the ventilation mode (Bypass mode/heat exchange mode) Between 1 and 5: Operation (ON/OFF) Use a microcurrent contact (DC12V, 1mA). In addition, ON/OFF operation is possible when using a voltage of DC12V or 24V. 6. Blue wire () is connected as factory default. To switch to Extra, connect black wire s connector instead of blue. 7. When the temperature of the outdoor air is below -1 C, the unit runs in the cold mode (the ventilator for air supply runs intermittently). The unit cannot run when the temperature of the outdoor air is below -15 C. The ventilator for air supply stops running and the ventilator for air exhaust also stops depending on the settings. 8. Even if Bypass mode is selected manually, the unit switches to Heat exchange mode automatically to prevent condensation when the temperature of the outdoor air is below 15 C. However, Bypass mode is still displayed. 9

4. Center of gravity VN-M1 to 1HE Unit: mm B C EA (Exhaust air) RA (Return air) A Outdoor side Indoor side OA (Outdoor air) Centre of gravity SA (Supply air) 6 or more 1 to 2 2 For the inspection of Filters, Heat Exchange Elements, Fans, Motors and Damper. Inspection Opening 4 4 or more VN-M1 and 2HE B C A Model Name A (mm) B (mm) C (mm) Weight (kg) Heat exchange element VN-M1HE, M2HE 9 9 29 36 2 VN-M3HE 9 9 29 38 2 VN-MHE, M6HE 114 114 3 53 2 VN-M8HE, M1HE 1189 1189 4 7 2 VN-M1HE, M2HE 1189 1189 81 143 4 1

5. Electrical characteristics Hz Model VN-M1HE VN-M2HE VN-M3HE VN-MHE VN-M6HE VN-M8HE VN-M1HE VN-M1HE VN-M2HE Nominal Voltage (V-Ph-Hz) Voltage Range Fan Motor Power Supply Min Max kw FLA MCA MOCP 22-1- 198 242.13 x 2.28.32 15 23-1- 27 253.14 x 2.29.33 15 24-1- 216 264.17 x 2.31.33 15 22-1- 198 242.24 x 2.56.61 15 23-1- 27 253.25 x 2.59.63 15 24-1- 216 264.24 x 2.58.65 15 22-1- 198 242.55 x 2.75.81 15 23-1- 27 253.57 x 2.78.82 15 24-1- 216 264.58 x 2 1.1.82 15 22-1- 198 242.69 x 2 1.12 1.19 15 23-1- 27 253.72 x 2 1.17 1.21 15 24-1- 216 264.76 x 2 1.28 1.23 15 22-1- 198 242.78 x 2 1.29 1.37 15 23-1- 27 253.81 x 2 1.35 1.39 15 24-1- 216 264.92 x 2 1.49 1.41 15 22-1- 198 242.123 x 2 2.6 2.15 15 23-1- 27 253.129 x 2 2.15 2.19 15 24-1- 216 264.137 x 2 2.26 2.23 15 22-1- 198 242.17 x 2 2.76 2.89 15 23-1- 27 253.178 x 2 2.88 2.92 15 24-1- 216 264.24 x 2 3.19 2.94 15 22-1- 198 242.123 x 4 4.8 4.3 15 23-1- 27 253.129 x 4 4.26 4.3 15 24-1- 216 264.137 x 4 4.66 4.3 15 22-1- 198 242.17 x 4 5.32 5.6 15 23-1- 27 253.178 x 4 5.56 5.6 15 24-1- 216 264.24 x 4 6.39 5.6 15 Fan Motor : 2(4)pcs/unit MCA :Minimum Circuit Amps FLA :Full Load Amps MOCP :Maximum Overcurrent Protection (Amps) kw :Fan Motor Reated Output 11

6. Fan characteristics (24V~, Hz) P-Q Curve * When friction coefficient of pipe (duct) : VN-M1HE VN-M2HE External static pressure (Pa) 3 2 2 1 1 Temperature Enthalpy (in heating) Enthalpy (in cooling) Extra 1 1 2 2 3 3 m 3 Air Volume (m /h) Equivalent pipe length 2 m 1 m 9 8 7 6 Duct resistance curve Exchange Efficiency (%) External static pressure (Pa) 3 3 2 2 1 1 Temperature Enthalpy (in heating) Extra Enthalpy (in cooling) 1 m Equivalent pipe length 1 1 2 2 3 3 4 8 m 6 m 4 m 2 m 9 8 7 6 Duct resistance curve Exchange Efficiency (%) 3 Air Volume (m /h) External static pressure (Pa) VN-M3HE 4 3 3 2 2 1 1 Temperature Enthalpy (in heating) Enthalpy (in cooling) Extra 1 m 1 2 3 4 6 8 m 6 m 4 m Equivalent pipe length 3 Air Volume (m /h) 2 m 9 8 7 6 Duct resistance curve Exchange Efficiency (%) External static pressure (Pa) VN-MHE 4 3 3 2 2 1 1 Temperature Enthalpy (in heating) Enthalpy (in cooling) Extra 1 2 3 4 6 7 8 9 3 Air Volume (m /h) 1 m 8 m 6 m 4 m 2 m 9 8 7 6 Duct resistance curve Exchange Efficiency (%) VN-M6HE VN-M8HE External static pressure (Pa) 4 4 3 3 2 2 1 1 Enthalpy (in heating) Temperature Enthalpy (in cooling) Extra 1 2 3 4 6 7 8 9 3 Air Volume (m /h) Equivalent pipe length 1 m 8 m 6 m 4 m 2 m 9 8 7 6 Duct resistance curve Exchange Efficiency (%) External static pressure (Pa) 4 4 3 3 2 2 1 1 Temperature Enthalpy (in heating) Enthalpy (in cooling) Extra Equivalent pipe length 1 m 1 2 3 4 6 7 8 9 1 11 12 13 8 m 6 m 4 m 2 m 9 8 7 6 Duct resistance curve Exchange Efficiency (%) 3 Air Volume (m /h) 12

(24V~, Hz) P-Q Curve * When friction coefficient of pipe (duct) : VN-M1HE VN-M1HE 4 4 Temperature Enthalpy (in heating) 9 8 7 Exchange Efficiency (%) 4 4 Temperature Enthalpy(in heating) 9 8 7 Exchange Efficiency (%) External static pressure (Pa) 3 3 2 2 1 1 Extra Enthalpy (in cooling) Equivalent pipe length 1 m 8 m 6 m 4 m 2 m 6 Duct resistance curve External static pressure (Pa) 3 3 2 2 1 1 Extra high Enthalpy(in cooling) 6 1 2 3 4 6 7 8 9 1 11 12 13 14 1 2 4 6 8 1 12 14 16 18 2 22 24 26 3 Air Volume (m /h) 3 Air Volume (m /h) VN-M2HE 4 4 Temperature Enthalpy(in heating) 9 8 7 Exchange Efficiency (%) External static pressure (Pa) 3 3 2 2 1 1 Enthalpy(in cooling) Extra high 6 2 4 6 8 1 12 14 16 18 2 22 24 26 28 3 Air Volume (m /h) 13

7. Sound characteristics (NC curve) (24V~, Hz) VN-M1HE 9 Extra 8 Under from body 1.5m 1.5m Measuring point Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 1 63 125 2 1 2 4 8 VN-M2HE VN-M3HE 9 8 Extra 9 8 Extra Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 2 NC-2 NC-2 1 1 63 125 2 1 2 4 8 63 125 2 1 2 4 8 VN-MHE VN-M6HE 9 8 Extra 9 8 Extra Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 2 NC-2 1 1 63 125 2 1 2 4 8 63 125 2 1 2 4 8 14

(24V~, Hz) VN-M8HE 9 8 Extra Under from body 1.5m 1.5m Measuring point Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 1 63 125 2 1 2 4 8 VN-M1HE VN-M1HE 9 Extra 9 Extra 8 8 Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 2 NC-2 NC-2 1 1 63 125 2 1 2 4 8 63 125 2 1 2 4 8 VN-M2HE 9 8 Extra Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 1 NC-2 63 125 2 1 2 4 8 15

(24V~, Hz) VN-M1HE 9 Extra 8 1.5m SA 45 Measuring point Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 1 63 125 2 1 2 4 8 VN-M2HE VN-M3HE 9 Extra 9 Extra 8 8 Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 2 NC-2 NC-2 1 1 63 125 2 1 2 4 8 63 125 2 1 2 4 8 VN-MHE VN-M6HE 9 Extra 9 Extra 8 8 Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 2 NC-2 1 1 63 125 2 1 2 4 8 63 125 2 1 2 4 8 16

(24V~, Hz) VN-M8HE 9 Extra 8 1.5m SA 45 Measuring point Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 1 63 125 2 1 2 4 8 Octabe band center frequency(hz) VN-M1HE VN-M1HE 9 Extra 9 Extra 8 8 Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 2 NC-2 NC-2 1 1 63 125 2 1 2 4 8 63 125 2 1 2 4 8 VN-M2HE 9 8 Extra Octave band sound pressure level(db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 1 NC-2 63 125 2 1 2 4 8 17

Air to Air Heat exchanger with DX-coil Type MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE 18

Air to Air Heat exchanger with DX-coil Type Contents Technical Data 1. MMD-VNxx2HEXE (Hz) 1-1. Specifications...3 1-2. Exchange Efficiency Correction...5 1-3. Sensible Capacity Table...6 1-4. Dimension...8 1-5. Wiring Diagram...11 1-6. Fan Characteristics...12 1-7. Sound Characteristics (NC Curve)...13 19

1. Specifications Item OA conditioning load Capacity code Power supply (V) Fan unit Temperature Exchange Efficiency (%) Enthalpy Exchange Efficiency (%) Weight (kg) Model MMD-VN2HEXE MMD-VN82HEXE MMD-VN12HEXE Cooling kw 4.1 (1.3 *) 6.56 (2.6 *) 8.25 (2.32 *) Heating kw 5.53 (2.33 *) 8.61 (3.61 *) 1.92 (4.32 *) 1 1.7 2 (Extra high) 139 222 264 139 222 264 122 178 228 (Extra high) 12 12 135 15 1 12 115 1 15 er Limit 92 133 178 Upper Limit 167 267 317 (Extra high) 7.5 7 65.5 7.5 7 65.5 71.5 72.5 67.5 (Extra high) 56.5 56 52 56.5 56 52 57.5 59 54 (Extra high) 68.5 7 66 68.5 7 66 69 73 68.5 (Extra high).3.51.55.28.47.55.24.34.49 Extra A 1.3 2.25 2.46 A 1.21 2.7 2.43 A 1.1 1.46 2.16 (Extra high) 37.5 41 43 36.5 4 42 34.5 38 4 169 x 114 x 43 84 1 11 Duct Spigot Ø (mm) 2 2 Heat exchanger Heat-insulating material Heating Cooling Power Input (Heat exchange mode) Running Current (Amps) Sound pressure level (db(a)) Standard Airflow (L/s) External static pressure (Pa) Airflow Limit (L/s) Dimension (Length x Width x Height) (mm) Single phase 22-24V~Hz Finned tube Flexible urethane foam 1739 x 1189 x 43 Air filter Standard filter (Gravitational method 82%) & efficiency filter (Colorimetric method 65%) Controller Remote controller (Sold Separately) Connection Pipe Size Gas mm Ø9.5 Ø12.7 Ø12.7 Liquid mm Ø6.4 Ø6.4 Ø6.4 Drain port (Nominal dia. mm) Ø25 (Polyvinyl chloride tube) 1. Cooling and heating capacities are based on the following conditions: Cooling capacities are based on: indoor temperature: 27 CDB/19 CWB, Outdoor temperature: 35 CDB Heating capacities are based on: indoor temperature: 2 CDB, Outdoor temperature: 7 CDB/6 CWB 2. fan mode is set from factory, extra high fan mode can be set by hard wiring on fan coil PC board 3. * Indicates the heat reclaimed from the heat recovery ventilator 4. Sound pressure level is measured 1.5m below the center of the unit, and within an acoustic chamber 2

1.1 Connectability of Air to Air Heat Exchanger with DX Coil ## NOTE: NOT CONNECTABLE TO SHRM (HEAT RECOVERY SYSTEMS) OR MINI SMMS SYSTEMS ## 21

Air to Air Heat exchanger with DX-coil Type 1-2. Exchange Efficiency Correction Exchange efficiency correction when supply air volume and exhaust air volume are different Exchange efficiency correction curve Exhaust to supply ratio Exhaust air volume / Supply air volume Exchange efficiency based on supply air volume [%] 9 8 7 6 4.5.6.7.8.9 1. 1.1 1.2 1.31.41.5 4 6 7 8 9 1 Corrected exchange effciency [%] efficiency based on supply air volume correction curve corresponding to use condition Temperature exchangeefficiency Enthalpyexchange efficiency (heating) Enthalpyexchange efficiency(cooling) Exchange efficiency Air flow supply air volume corrected efficiency 22

Air to Air Heat exchanger with DX-coil Type 1-3. Sensible Capacity Table Cooling capacity tables MMD-VN ***HEXE Class DX-coil capacity [kw] 2 2.8 82 4.5 12 5.93 Outdoor temp. [ CDB] TC: Total Capacity [kw] SHC: Sensible Heat Capacity [kw] DX-coil inlet temp. [ CWB] 16. 18. 19. 2. 22. 24. TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 1. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 12. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 14. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 16. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 18. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 2. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 21. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 23. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 25. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 27. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 29. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 31. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 33. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 35. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.8 37. 2.5 1.7 2.7 1.8 2.8 1.8 2.9 1.8 3. 1.8 3.2 1.7 39. 2.4 1.7 2.6 1.8 2.7 1.8 2.8 1.8 2.9 1.8 3.1 1.7 1. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 12. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 14. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 16. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 18. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 2. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 21. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 23. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 25. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 27. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 29. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 31. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 33. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 35. 4.1 2.8 4.4 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 37. 4. 2.7 4.3 2.9 4.5 2.9 4.6 2.9 4.9 2.9 5.1 2.8 39. 3.9 2.7 4.2 2.8 4.4 2.8 4.5 2.9 4.7 2.8 5. 2.7 1. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 12. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 14. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 16. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 18. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 2. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 21. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 23. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 25. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 27. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 29. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 31. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 33. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 35. 5.3 3.7 5.7 4. 5.9 4. 6.1 4. 6.4 3.9 6.8 3.8 37. 5.3 3.7 5.7 3.9 5.9 3.9 6.1 3.9 6.4 3.9 6.7 3.8 39. 5.2 3.6 5.6 3.8 5.7 3.8 5.9 3.8 6.2 3.8 6.5 3.7 23

Air to Air Heat exchanger with DX-coil Type Heating capacity tables MMD-VN ***HEXE Class DX-coil capacity [kw] 2 3.2 82 4.8 12 6.6 Outdoor temp. [ CWB] DX-coil inlet temp. [ CDB] 16. 18. 2. 22. 24. SHC SHC SHC SHC SHC 15. 1.9 1.8 1.8 1.8 1.7 13. 2. 2. 2. 1.9 1.9 11. 2.2 2.1 2.1 2. 2. 1. 2.2 2.2 2.2 2.1 2.1 8. 2.4 2.3 2.3 2.2 2.2 6. 2.5 2.4 2.4 2.3 2.3 4. 2.5 2.4 2.3 2.3 2.2 2. 2.5 2.5 2.4 2.4 2.3. 2.6 2.7 2.6 2.5 2.5 2. 2.8 2.8 2.7 2.6 2.6 4. 3.2 3.1 3. 3. 2.9 6. 3.3 3.3 3.2 3.1 3. 8. 3.3 3.3 3.2 3.1 3. 1. 3.3 3.3 3.2 3.1 3. 12. 3.3 3.3 3.2 3.1 3. 14. 3.3 3.3 3.2 3.1 3. 15. 2.8 2.8 2.7 2.6 2.6 13. 3. 3. 2.9 2.9 2.8 11. 3.3 3.2 3.1 3.1 3. 1. 3.4 3.3 3.2 3.2 3.1 8. 3.6 3.5 3.4 3.3 3.3 6. 3.7 3.6 3.6 3.5 3.4 4. 3.7 3.5 3.5 3.4 3.3 2. 3.8 3.7 3.6 3.5 3.4. 3.9 4. 3.9 3.8 3.7 2. 4.2 4.1 4.1 4. 3.9 4. 4.7 4.7 4.6 4.5 4.3 6. 5. 4.9 4.8 4.7 4.6 8. 5. 4.9 4.8 4.7 4.6 1. 5. 4.9 4.8 4.7 4.6 12. 5. 4.9 4.8 4.7 4.6 14. 5. 4.9 4.8 4.7 4.6 15. 3.9 3.8 3.7 3.6 3.5 13. 4.2 4.1 4. 3.9 3.8 11. 4.5 4.4 4.3 4.2 4.1 1. 4.6 4.5 4.4 4.3 4.2 8. 4.9 4.8 4.7 4.6 4.5 6. 5.1 5. 4.9 4.8 4.6 4. 5.1 4.9 4.8 4.7 4.5 2. 5.2 5.1 5. 4.9 4.7. 5.4 5.5 5.4 5.2 5.1 2. 5.8 5.7 5.6 5.4 5.3 4. 6.5 6.4 6.3 6.1 6. 6. 6.9 6.7 6.6 6.4 6.3 8. 6.9 6.7 6.6 6.4 6.3 1. 6.9 6.7 6.6 6.4 6.3 12. 6.9 6.7 6.6 6.4 6.3 14. 6.9 6.7 6.6 6.4 6.3 TC: Total Capacity [kw] SHC: Sensible Heat Capacity [kw] 24

Air to Air Heat exchanger with DX-coil Type 1-4. Dimension MMD-VN2HEXE Attention 1. Duct size (Nominal diameter): ø2 2. The above dimensions do not include the thickness of the insulation material on the unit body. 25

Air to Air Heat exchanger with DX-coil Type MMD-VN82HEXE Attention 1. Duct size (Nominal diameter): ø2 2. The above dimensions do not include the thickness of the insulation material on the unit body. 26

Air to Air Heat exchanger with DX-coil Type MMD-VN12HEXE Attention 1. Duct size (Nominal diameter): ø2 2. The above dimensions do not include the thickness of the insulation material on the unit body. 27

Air to Air Heat exchanger with DX-coil Type 1-5. Wiring Diagram MMD-VN2HEXE, MMD-VN82HEXE, MMD-VN12HEXE Code CN*** F1 F2 FM1 FM2 DAM TRA TOA TSA TFA TCJ, TC1, TC2 Parts name Connector Fuse (Printed circuit board) Fuse (Motor) Air supplying motor Air exhausting motor Damper motor TRA sensor TOA sensor TSA sensor TFA sensor Indoor coil sensor Code Parts name TB1 Terminal block (Power source) TB2 Terminal block (Communication) TB3 Terminal block (External output) TS1 Float switch PMV Pulse modulating value SW71 Dip switch 43F11, 43F12 Relay for air supplying motor 43F21, 43F22 Relay for air exhausting motor RY71, RY72 Relay for air supplying motor RY74, RY75 Relay for air exhausting motor 1. The dotted line represents a wire procured locally, and the dashed line represents an option sold separately. 2. represents a terminal block, represents a connection terminal, represents a connector on the printed circuit board and represents a short circuit connector. 3. represents a protective earth. 4. represents a printed circuit board. 5. Using a no voltage a-contact input of the external input (option), the following operations are available. Between 1 and 2: Selecting the remote controller operation (Invalid/Valid) Between 1 and 3: Adjusting the fan speed (/) Between 1 and 5: Operation (ON/OFF) Use a microcurrent contact (DC12V, 1mA). In addition, ON/OFF operation is possible when using a voltage of DC12V or 24V. 6. Orange wire () is connected as factory default. To switch to Extra, connect black wire s connector instead of orange. 28

Air to Air Heat exchanger with DX-coil Type 1-6. Fan Characteristics MMD-VN2HEXE MMD-VN82HEXE 23V, Hz 3 3 er limit air volume : 33m /h, Upper limit air volume : 6m /h 3 Standard air voleme : m /h Standard air voleme : 8m /h 3 3 er limit air volume : 48m /h, Upper limit air volume : 96m /h 3 External static pressure [Pa] 4 3 3 2 2 1 Temperature exchange efficiency Enthalpy exchange efficiency (heating) Enthalpy exchange efficiency (cooling) Extra 8 7 6 4 3 Exchange efficiency [%] External static pressure [Pa] 4 3 3 2 2 1 Temperature exchange efficiency Enthalpy exchange efficiency (heating) Enthalpy exchange efficiency (cooling) Extra 8 7 6 4 3 Exchange efficiency [%] 1 2 1 2 1 1 1 2 3 4 6 7 Air flow [m 3 /h] 2 4 6 8 1, Air flow [m 3 /h] MMD-VN12HEXE 3 Standard air voleme : 9m /h 3 3 er limit air volume : 64m /h, Upper limit air volume : 114m /h 4 8 External static pressure [Pa] 3 3 2 2 1 Enthalpy exchange efficiency (heating) Temperature exchange efficiency Enthalpy exchange efficiency (cooling) Extra 7 6 4 3 Exchange efficiency [%] 1 2 1 2 4 6 8 1, 1,2 Air flow [m 3 /h] 29

Air to Air Heat exchanger with DX-coil Type 1-7. Sound Characteristics (NC Curve) Model name Power supply (phase/hz/v) Sound pressure level (db) Extra MMD-VN2HEXE Under from body 1.5m 37.5 36.5 34.5 MMD-VN82HEXE 1 phase / Hz / 22V-24V 41. 4. 38. 1.5m MMD-VN12HEXE 43. 42. 4. Measuring point MMD-VN2HEXE 9 MMD-VN82HEXE 9 8 Extra 8 Extra Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 2 NC-2 NC-2 1 1 63 125 2 1 2 4 8 Octave band center frequency (Hz) 63 125 2 1 2 4 8 Octave band center frequency (Hz) MMD-VN12HEXE 9 8 Extra Octave band sound pressure level (db) 7 6 4 3 2 1 NC-7 NC-6 NC- NC-4 NC-3 NC-2 63 125 2 1 2 4 8 Octave band center frequency (Hz) 3

Air to Air Heat exchanger with DX-coil Type Model name Power supply (phase/hz/v) Sound pressure level (db) Extra MMD-VN2HEXE SA 39.5 39. 37. MMD-VN82HEXE 1 phase / Hz / 22V-24V 45 44.5 44.5 4.5 1.5m Measuring point MMD-VN12HEXE 47. 47. 45. MMD-VN2HEXE 9 8 Extra MMD-VN82HEXE 9 8 Extra Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 Octave band sound pressure level (db) 7 6 4 3 NC-7 NC-6 NC- NC-4 NC-3 2 NC-2 2 NC-2 1 1 63 125 2 1 2 4 8 Octave band center frequency (Hz) 63 125 2 1 2 4 8 Octabe band center frequency (Hz) MMD-VN12HEXE 9 8 Extra Octave band sound pressure level (db) 7 6 4 3 2 1 NC-7 NC-6 NC- NC-4 NC-3 NC-2 63 125 2 1 2 4 8 Octave band center frequency (Hz) 31

Notice: Toshiba is committed to continuously improving its products to ensure the highest quality and reliability standards, and to meet local regulations and market requirements. All features and specifications are subject to change without prior notice. Air to Air Heat exchanger Type Databook Dec, 211 First Edition