Advanced Ultraviolet Burner Controller

Similar documents
AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C. Advanced Ultraviolet Burner Controller

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

BC-R10 Series. Burner Controllers

General Specifications

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

UV Flame Supervision System

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

24 VAC Intermittent Pilot Gas Ignition Control

DIGITAL BURNER CONTROLLER DBC2000 SERIES

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Eclipse 90 UV Scanner Model A Version 1

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Digital Heater Element Burnout Detector K8AC-H

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

Buzzer Unit. TAN-5000 Series. Operating Manual

ISOLATOR SGI SGIW INSTRUCTION MANUAL

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

DIGITAL INDICATOR JIR-301-M

MBCE-110/230UV Flame Sensor Module

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

C Note! LGI16... Burner Controls. Building Technologies

BGH Series Hot Surface Ignition Control

Instruction manual Temperature Controller KT7

Instruction manual for DIN rail mounting type indicating controller DCL-33A

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

E3M-V. Mark Sensor. Applications

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

Operator: Save these instructions for future use!

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Fireye FLAME SCANNERS

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

24 VAC Direct Spark Gas Ignition

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Furnace Gas Monitor SD Operating Manual (PT2-163)

Eclipse Self-Check UV Scanner

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

EUROFLAT SERIES TYPES C... S... M...

Smart Transmitter/ Gas Detector Head

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

Two-Channel Gas Controller

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Distributed By: M&M Control Service, INC

Rules for Intruder Alarm Systems

Flame Safeguards LFE10. Building Technologies HVAC Products

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

250mm dia straight pipe length SP4 SP3. Air volume

Model Number Structure

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Public Safety DAS Annunciator Panel

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Model 3300 Technical Support and Installation Manual

Universal fault annunciator for panel mounting

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Analog Room Pressure Monitor RPC Series

EUROBOX SERIES TYPES CM... SM... MM...

TEMPERATURE CONTROLLER

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

Instruction manual Micro-computer based digital indicating controller

M2500 Engine Controller Installation Manual

GCS-300 No.GCS31E

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

InBio X60 Series Access Control Panel User Manual

7800 SERIES RM7888A Relay Module

Smart Transmitter/Gas Detector Head SD-1GH. Operating Manual (PT2-169)

INSTRUCTION MANUAL Micro-computer based digital indicating controller

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

VM-704B & VM-704 Temperature Monitor Module Manual

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

SHIMADEN DIGITAL INDICATORS

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

02/11/2015

02/11/2015

Smart transmitter/ Gas Detector Head SD-1. Operating Manual (PT2-160)

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Operator: Save these instructions for future use!

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

Operator: Save these instructions for future use!

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Ultrasonic Reflective Sensor

Transcription:

No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication Function are used for continuous or batch operation and have a dynamic self-checking function. These controllers are used in combination with the AUD300C Advanced Ultraviolet Flame Detector or AUD00C Explosion- Proof Advanced Ultraviolet Flame Detector. By driving the shutter of the AUD300C or AUD00C flame detector, the controller continuously checks the tube unit and flame detection circuit and monitors combustion. If somehow a problem develops in the flame detection circuit of the AUD300C, AUD00C, AUR300C, or AUR30C, the controller turns off the relays without fail in order to secure the safety of the system. The AUR30C, which is equipped with an RS- communication function, can be used in many applications in combination with a PC or display unit. AUR300 AUR30 Features When any abnormality exists at the startup of operation, the start-check relay is not energized, ensuring safety by not generating a signal to the main valve or flame output. Operation status can be confirmed by LED displays (power, shutter, start check and flame). Flame signal output (0 to V DC) is provided as a standard function. This is useful for burner adjustment and flame status control. A special loader (Smart Loader Package) for configuring the AUR30C from a PC is available (for the AUR30 only). The operation of the K3 relay (ON when an event* occurs, when flame voltage high or low limit is exceeded, or when maintenance cycle is due; or synchronous operation with relays K1 or K) can be specified using the Smart Loader Package (with the AUR30 only). With the RS- communication function, monitored trend data (flame voltage, shutter cycle, K1 K3 relay operation), maintenance data, and playback data (event history) can be displayed on a PC using the Smart Loader Package (with the AUR30 only). * In the case of the AUR30C, false flame, false discharge, frame ground short circuit, flame voltage drop, etc., are called events. The various settings are preset. Precautions for equipment instrumentation When designing facilities that include combustion safety equipment, take the safety directives listed below into careful consideration. Safety Engineering Directives for Industrial Heating Furnace Combustion Equipment (Health, Labor and Welfare Ministry) General Safety Code for Industrial Combustion Furnaces (= JIS B 1) Safety Engineering Directives for Industrial Gas Combustion Equipment (The Japan Gas Association) Safety Guidelines for Gas Boiler Combustion Equipment (The Japan Gas Association) Important safety points 1. Directly connect the load to this device.. Structure the interlock so that power to the load is directly turned off. 3. Use the start check circuit during startup (do not short out the start contact input).. Do not make a manual operation circuit or other bypass circuit for any load.. Use redundant shutoff for both the main valve and pilot valve. Precautions for system design Use an external circuit for the purge function (this device does not have a purge function). 1

Specifications General specifications Item Compatible flame detector Flame failure response time (3 V flame voltage) Flame voltage output Flame voltage range (at rated voltage, room temp, and humidity) Recommended flame voltage Rated power supply voltage Allowable voltage range Power consumption Dielectric strength Insulation resistance Induced thunderbolt surge Service life AUD300, AUD00 Nominal 1. s (max. s), Nominal 3 s (max. s) (selectable by model number) 0 V DC Flame establishment: 1. to.0 V DC Flame-out detection: 0.0 to 0. V DC Stable.0 V DC or more 0 V AC or 00 V AC at 0/0 Hz to 1 % of rated power supply voltage W max. (with AUD300C/00C) 100 V AC 0/0 Hz 1 min or 0 V AC 0/0 Hz 1 s Application points: Between ground and primary terminals 1 to (except 9 to ) 0 MΩ min. by a 00 V DC megger Measurement points: Between ground and primary terminals 1 to (except 9 to ) kv, 1./0 μs (JEC-17: 7 Ω min. surge impedance) The surge absorber listed hereunder must be connected between the power supply terminal (No.1 terminal) and the ground. Recommended surge absorber: Part No. 39019-001 7 years or 0,000 cycles (operation cycles of each relay) Ambient temperature 0 to +0 C Storage temperature 0 to +70 C Ambient humidity 90 % RH at 0 C max. (without condensation) Vibration resistance.9 m/s max., to Hz for hours each in X, Y and Z directions Mounting posture Wall mounting (vertical or horizontal mounting) Color White Mass Approx. 1. kg Communication specifications (only AUR30C) Item Communication level RS- compliant Transmission line connection Multipoint (up to 1 slave stations for 1 master station) Communication method Half-duplex Synchronization method Start-stop Transmission control Polling-selecting method (CPL communications format) Maximum cable length 00m Transmission line 3-wire system Transmission speed error 0.1 % Terminating resistor Built in. Do not attach an external resistor. Transmission speed 00, 00, 900, 1900 bps Data length bits Stop bits 1 or Parity bit Even parity or no parity Model selection table Basic No. AUR300C AUR30C Function Flame response Power supply Additional processing 1 Advanced ultraviolet burner controller Nominal 1. s (max. s) 3 Nominal 3 s (max. s) 1 0 V AC 00 V AC Advanced ultraviolet burner controller with communication function 00 No additional processing D0 T0 DT Inspection certificate provided Tropicalization treatment applied Tropicalization treatment applied and inspection certification provided

AUR300C part names Mounting holes : locations Install the product with M screws. Indicators Details on indicators Name Color POWER Green Lit when power supply is ON SHUTTER Green Lit when shutter is closed START CHECK Green Synchronous with K1 relay (start check) FLAME Green Synchronous with K relay (flame detection) SHUTTER (G) 1 1 UV SENSOR (F) 11 11 0-V + 9 9 Terminals for connecting an AUD300C or AUD00C Advanced Ultraviolet Flame Detector : Connect an AUD300C or AUD00C. Use M screws. K3 K1 K 7 7 3 3 Input/output terminals : Connect the power and various output signals. Use M screws. 1 1 Chassis ground connection : This is also used as a mounting hole. The coating has been removed to provide a good connection. Terminal assignments Terminal No. Electrical rating AUD300C/00C Shutter (white) DC V 10 ma *1 AUD300C/00C Shutter (white) 1 AUD300C/00C G-terminal (yellow) 11 AUD300C/00C F-terminal (blue) Flame voltage output (-) 0 V DC * 9 Flame voltage output (+) K3 relay output * 3 3 A 0 V 7 K3 relay output * 3 (cosφ=1) Flame output (K1, K) A 0 V (cosφ=1) Common contact output K relay (N.C. flame relay ) A 0 V(cosφ=1) 3 Start input Power supply (R) high-voltage side 0/00 V AC 1 Power supply (S) ground side 0/0 Hz *1 : Shutter does not have polarity. * : Use a measuring instrument with an input impedance of 0 KΩ or more. To connect this device, use IV lead wires of 0.7 mm no longer than m. *3 : Operation is the same as for the K relay. (However, since a start-checking function is not provided, do not use for combustion control, but only for combustion monitoring.) These terminals cannot be used for abnomal state output. 3

AUR30C part names Mounting holes : locations Install the product with M screws. Details on indicators Name Color POWER Green Lit when power supply is ON SHUTTER Green Lit when shutter is closed Indicators and communication terminal START CHECK Green Red Synchronous with K1 relay (start check) Blinks when an event occurs. SHUTTER (G) 1 UV SENSOR (F) 11 1 11 Terminals for connecting an AUD300C or AUD00C Advanced Ultraviolet Flame Detector : Connect an AUD300C or AUD00C. Use M screws. FLAME Green Orange Red Synchronous with K relay (flame detection) The color depends on the flame voltage. Green :. V min. Orange : 1. to. V Red : Less than 1. V Off when the K relay is off. 0-V + 9 9 K3 K1 K 7 7 3 3 Input/output terminals : Connect the power and various output signals. Use M screws. 1 1 Chassis ground connection : This is also used as a mounting hole. The coating has been removed to provide a good connection. Terminal assignments Terminal No. Electrical rating AUD300C/00C Shutter (white) DC V 10 ma *1 AUD300C/00C Shutter (white) 1 AUD300C/00C G-terminal (yellow) 11 AUD300C/00C F-terminal (blue) Flame voltage output (-) 0 V DC * 9 Flame voltage output (+) K3 relay output * 3 3A 0 V(cosφ=1) *1 : Shutter does not have polarity. * : Use a measuring instrument with an input impedance of 0 KΩ or more. To connect this device, use IV lead wires of 0.7 mm no longer than m. *3 : For the K3 relay, various outputs upon the occurrence of an abnormal state can be specified using the loader. With the default settings, the K3 relay turns on when an event occurs (specifically, when K turns off because of false discharge). 7 K3 relay output * 3 Flame output (K1, K) A 0 V(cosφ=1) Common contact output K relay (N.C. flame relay) A 0 V(cosφ=1) 3 Start input Power supply (R) high-voltage side 0/00 V AC 1 Power supply (S) ground side 0/0 Hz

Switch layout and function The AUR30C has a station address setting switch for communications, and also reset switches. These switches are located behind the protective plate of the AUR30C display. To set a station address or to reset events or values, pull the upper part of the plate toward you to remove it from the peg, and slide the plate upward. Switch layout S: Reset selection switch This DIP switch is used to select what to reset. S3: Reset switch This switch is used in combination with the S reset selection switches to clear the current maintenance cycle settings and to reset events. S1: Rotary switch for setting a station address A station address for RS- communication can be selected from 0 to F (1 addresses). Loader jack RS- communication connector Events or current values are reset by pressing the S3 switch. What is reset depends on on/off state of the S DIP switches. S 1 3 Events What is reset by pressing the S3 switch The current value of the item specified in maintenance cycle setting 1 The current value of the item specified in maintenance cycle setting The current value of the item specified in maintenance cycle setting 3 The current value of the item specified in maintenance cycle setting : ON : OFF Multiple S switches can be ON at the same time. For example, if the S3 reset switch is pressed with S-1 and S-3 set to ON, the current value of the items specified for maintenance cycles 1 and 3 will be cleared. All S switches are set to OFF at the factory.

Wiring Monitoring of burner flame Manual ignition (intermittent pilot) AUR300C, AUR30C AUR300C, AUR30C Advanced UV detector AUD300C/00C white white yellow blue 1(G) 11(F) Shutter driving circuit Flame amplifying circuit SHUTTER LED K driving circuit K RS- communication LOADER * white SG DB DA Advanced UV detector AUD300C/00C white yellow blue 1(G) 11(F) Shutter driving circuit Flame amplifying circuit SHUTTER LED K driving circuit K RS- communication LOADER SG DB DA * Measuring instrument 0 V DC + 9 Flame voltage output circuit K3-1 Microprocessor FLAME LED START CHECK LED Measuring instrument 0 V DC + 9 Flame voltage output circuit K3-1 Microprocessor FLAME LED START CHECK LED Combustion lamp output (K3) Combustion lamp output (K3) Flame output Common contact output 7 K1-3 K- Main valve Start switch SW 7 K1-3 K- High-voltage side (H) Power supply (G) Ligh-voltage side K Start contact NC 3 (R) 1(S) Start check circuit K1- K1 K-1 K1-1 POWER LED Power circuit High-voltage side (H) Power supply (G) Ligh-voltage side Ignition transformer Pilot valve Limit Stop switch Start check circuit K1- K1 3 (R) 1(S) K-1 K1-1 POWER LED Power circuit * : Only AUR30C Handling Precautions If the power supply circuit has a high potential side (H) and low potential side (G), connect the high potential side (H) to terminal (R) and the low potential side (G) to terminal 1 (S). If necessary, connect a device for overload protection to the power supply.

Dimensions AUR300 AUR30 (Unit : mm) 9.1 0 37 0 37 -R -R Free terminal screw M SHUTTER SHUTTER (G) 1 UV SENSOR (F) 11 1 11 3 9 1 (G) 1 UV SENSOR (F) 11 1 11 3 9 1 0-V + 9 9 0-V + 9 9 K3 K3 7 7 7 7 K1 K1 K K 3 3 3 3 1 1 1 1 1. 1. 7. 1. 7. 1. Chassis ground (commonly used as mounting screw) 7

Cautions Do not install the flame relay in the following locations: Near the following chemicals or where their vapors are present: ammonia, sulfur, chlorine, ethylene compounds, acid, or any other corrosive gases. Locations subject to water spray Locations subject to continuous vibration Before wiring, be sure to turn the power off. Touching terminals by mistake while the power is on may damage the device or result malfunction, or electrical shock. After completing wiring, be sure to check all wiring connections. Incorrect wiring may damage the device or result in malfunction. In particular, as the flame detector (11(F)-1(G) terminals) has polarity, a reversed connection of F and G will result in the malfunction of the detector tube unit. Use a dedicated packing case when transporting or storing this detector. Do not bundle the power leads together with the flame detector signal lead wires, nor place them in the same conduit. Use independent cables. Do not short-circuit the start input (terminals and 3) to operate the device by turning the power supply on or off. This interferes with the device s start-checking function. This device must be grounded with a resistance less than 0 Ω according to the technical standards for electrical facilities. Be sure to ground the device. Make sure that the ignition transformer high-voltage cables are properly connected in order to prevent faulty contacts. If there is a poor contact, radio frequency waves may be generated, resulting in errors from radio interference. Install the ignition transformer directly onto a metal part electrically connected to the burner. Protection against induced lightning surge is not provided in this device. When adding surge protection, connect the protection device between terminal No.1 and the ground. Recommended surge absorber: Part No. 39019-001. Turning the power supply on and off quickly may result in malfunction. Wait an interval of approx. 3 s before turning the device on or off again. Electricity may remain in No.11 (F) terminal even after the power supply is turned off. Touching the terminal within 1 min after the power has been turned off might result in electric shock. Do not touch the No.11 (F) terminal soon after the power has been turned off. Please read Terms and Conditions from the following URL before ordering and use. https://www.azbil.com/products/factory/order.html Specifications are subject to change without notice. 1-1- Kawana, Fujisawa Kanagawa 1- Japan https://www.azbil.com/ () 1st edition: Jun. 00 th edition: Nov. 01 No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.