BURGLAR, BALLISTIC, BLAST & FIRE RESISTANT SYSTEMS

Similar documents
ETEM SECURITY. for private and professional use

NOVOLAY secure. PYRANOVA secure. Special glass types with outstanding safety properties

Nor ms & Standards. Security standards: Protection against forced entry, ballistic and blast attacks, fire, smoke. Building physical requirements

DORTEK. Comprehensive range of certified high-security doors

DORTEK. Comprehensive range of certified high-security doors

G4S ACADEMY STANDARDS COMPARISON KEY

Steel Door Series S4. Certified Protection against Forced Entry, Fire, Ballistic and Blast Attacks. Protecting Lives and Property. Worldwide.

A new standard of burglar resistance EN 1627:2011 took force in Europe more security for your premises

Contents EN :2006+A2:2016 (E)

Protect human life against hazards at refineries and other sensitive. Complete cabin protected against blast, gas, fire and smoke

Transaction Windows and Security Entrances

SECURE & BEAUTIFUL

G4S ACADEMY BALLISTIC ATTACK MANAGEMENT SOLUTIONS

GUIDELINIE ECB S R10. March European Certification Body GmbH

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Security systems Protecting people and property

Annex of the certificate (Page 1/7) Accreditation Scope

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

FACADE OF SECURITY. Blast Resistance. Ballistic Resistance. Forced Entry Resistance. Fire Resistance. Jewish school and Jewish sport center, Vienna

Schueco Fire and Smoke Protection Systems

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

General test 74 Thermal properties 75 Fire windows 75 Sound reduction 76 Safety 76 CWCT accreditation 77 Resistance to forced entry (SBD) 78

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

CERBERUS DOORS E V E R Y PA R A D I S E N E E D S A H E L L O F A D O O R! 1

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Gallery. IS We hope you enjoy browsing thorough them as much as we have enjoyed making them. IMPREGNABLE SECURITY DOORS 71

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

AMPLIMESH SECURITY DOOR & WINDOW SCREENS

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

protects and secures.

ROLLER SHUTTER SOLUTIONS AS UNIQUE AS YOUR VISION. RollUp Serranda (Pty) Limited 0860 ROLLUP ( )

Risk Levels Intensify

THE 7 TYPES OF ENTRANCE FRAUD. Security Matters. How People Cheat Their Way In QUICK GUIDE AK-47 ATTACKS REDUCING SHRINKAGE

Forced Entry and Ballistic Defense

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Security Glass Solutions. Complete certified glass solutions designed for your application

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

Security. ModuSec. Introduction... 1 Walls... 2 Doors... 3 Locks... 5 Windows... 6

Window Types. TD-005 July 29, Window Types 101. Casement / Projected

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

PRODUCT CATALOGUE 2012

PRESS RELEASE

KEEP THE FIRE FROM SPREADING

Fire and Security Products and Services

DRAFT EUROPEAN STANDARD pren NORME EUROPÉENNE EUROPÄISCHE NORM April English version

Factory installed door organizer provides added storage for pistols, magazines and other gear. NEW

ROCHÉ SYSTEMS. Designer, manufacturer & installer of high quality physical security, awning & glass room solutions. COMMERCIAL

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

QRs GUN-SHOT DETECTION SYSTEM (GDS)

VdS 5478en : (01) Windows

Mechanically operated locks and locking plates

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

SHIELD SECURITY DOORS

Fire Protection. Intumescent fire and smoke seals for door assemblies

TUFFAK Sheet Products Guide

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Arlo Robot Base Kit (#28960)

BLAST AND PRESSURE-RESISTANT PRODUCTS. A wide range of blast- and pressure-resistant door and fixed window systems. AN ISO 9001 CERTIFIED COMPANY

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

The following checklists are to be used during an aerodrome RFFS inspection/ audit.

Fire Protection. Fire-resistant Glass Range. Pilkington Pyrostop. Pilkington Pyrodur

Annex of the certificate (Page 1/5) Accreditation Scope

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

An affiliate company of AR Challenges, Ltd. ISRAEL

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

High Security Locking. Product Catalogue

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Guide to interpreting Markings for Single Axis Fire Doors Hinges

ACTIVE FIRE CURTAINS INTISI7

The all-in-one airlock. Models: SkySas BA9S, SkySas BA9L. Manual Attack Resistance. Recyclable product. Ballistic Resistance.

PYRAN PYRANOVA NOVOLAY secure PYRANOVA secure

Shutters Measuring and Ordering Guide

Electromagnetic Locking Devices Performance Requirements

CCTV Camera Systems and Project Engineering

Fire Safety Fire Resistant Building Components

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Downlight ENCORE DL6 15W 2700K

Specifying Security Hardware for Doors

fire protection glass

The information provided in this presentation is to be considered Law Enforcement Sensitive

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

TIP FOR PR MAINTENANCE OS WORKSHOPS

LIST OF PUBLISHED STANDARDS

Security Glazing for Schools

Security Glazing for Schools

SVENSK STANDARD SS-EN 1522

SVENSK STANDARD SS-EN 1523

Entrance Control Range

Transcription:

BURGLAR, BALLISTIC, BLAST & FIRE RESISTANT SYSTEMS

PRESIDENTIAL PAVILLION, CONGO AIRPORT Arch. LUFTHANSA CONSULTING BALLISTIC RESISTANT CLASS BR7

2 Premium Partner for Safety Glazing Systems GLASSCON GmbH is a leading engineering and contracting company operating globally through subsidiaries and local partners. We specialize in bespoke façade solutions providing a complete line of custom architectural products to meet complex designs for glazing systems and curtain walling. GLASSCON offers solutions against a wide range of threat levels as part of our innovative security product range. Our solutions have been designed to deliver high-level protection against manual attack, ballistic, blast and fire threats and have been independently tested and certified by accredited testing institutes in accordance with the current European (EN) standards.

3 Safety At the Top of the List The world has changed. As safety concerns continue to rise, there s a growing demand for protection of people and property in both commercial and residential buildings. Managing threat scenarios requires simultaneous protection against forced entry, ballistic and blast attacks as well as fire hazards.

4 ΒURGLAR PROOF GLAZING SYSTEMS Burglar resistant systems have been certified in accordance with the EN 1627:2011 and EN 356:2000 standards. GLASSCON offers a range of solutions for doors, windows and curtain walls designed to resist actions of force by manual attack. Test methods for classification of the burglar resistance of security frame and glazing include static and load tests as well as manual attacks, which depending on the attacking time and force to which the samples are subjected, obtain classifications from RC1 to RC6, P1A to P5A and P6B to P8B. Key Features Internal or external use Increased mechanical strength and durability Slim sightlines and large expanses of glass Excellent anti-uv characteristics CE marking Options: thermal insulation, soundproofing, fire protection Applicable standards & classification levels EN 1627: 2011 Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Requirements and classification. EN 356: 2000 Glass in building. Security glazing. Testing and classification of resistance against manual attack. Classification Buglar proof glazing system Class RC1 Opportunistic burglars will try to break windows or doors using physical force, kicking, using their shoulders, levering or pulling outward. Class RC3 Burglars will try to break open, closed and secured windows or doors with RC2 tool plus additional use of a second screwdriver and a crowbar. Class RC2 Opportunistic burglars will try to break open, closed and secured windows or doors with the additional use of simple tools, such as a screwdriver or pliers. Class RC4 Experienced burglars also use saws and impact tools, such as an axe, a chisel, a hammer or a battery-powered driller. Class RC5 Experienced burglars also use electric tools, such as a drill, a compass or reciprocating saw and an angle grinder with a maximum disc diameter of 125 mm. Class RC6 Experienced burglars also use electric power tools, such as a drill, a compass or reciprocating saw and an angle grinder with a maximum disc diameter of 250 mm.

5 The Lower Resistance Level (Anti-Vandalism) ΒΑLL DROP TEST Class No of Strikes Drop height (m) Impact Energy (Joules) P1A 3 1.5 181 P2A 3 3 362 P3A 3 6 724 P4A 3 9 1.086 P5A 9 9 3.258 Ball weight 4,1Kg Requirement: To pass test, the ball must not penetrate the glass The Higher Resistance Level (Instrusion Deterrence) HAMMER AND AXE TEST Class P6B P7B P8B Number of blows 30 to 5O blows 51 to 7O blows More than 70 blows

6 ΒALLISTIC RESISTANT - BULLET PROOF GLAZING SYSTEMS Bullet resistant systems have been certified in accordance with the EN 1063:2000 and EN 1522:1999 standards. GLASSCON offers a range of bulletproof solutions for doors, windows and curtain walls that meet the requirements of protection from attacks by handguns, rifles and shotguns. Test methods for classification of the bullet resistance of glass and glass/plastic composites include firing tests which, depending on the caliber of the weapon used and the appearance or not of splinters on the protected part, obtain different classifications, from FB1 to FB7, BR1 to BR7 and SG1 to SG2. Key Features Internal or external use Increased mechanical strength and durability Slim sightlines and large expanses of glass Excellent anti-uv characteristics CE marking Options: thermal insulation, soundproofing, fire protection Applicable standards & classification levels EN 1063:2000 Glass in building. Security glazing. Testing and classification of resistance against bullet attack EN 1522:1999 Windows, doors, curtain walling, shutters and blinds. Bullet resistance. Requirements and classification Classification Ballistic resistant - Bullet proof glazing systems Safety System Class Glass Level FB1 BR 1 Gun Bullet Test Conditions Type Caliber Type Weight (g) Shooting Range (m) Bullet Speed (m/s) No. of Shots at 120 mm.22 LR LB/RN 2.6 10 360 ±10 3 FB2 BR 2 9X19 Para FJ/SC 8.0 5 400 ±10 3 Hand Gun FB3 BR 3.357 Magnum FJ/CB/SC 10.2 5 430 ±10 3 FB4 BR 4.44 Magnum FJ/FN/SC 15.6 5 440 ±10 3 FB5 BR 5 5.56X45 mm SS 109 FJ/PB/SCP1 4.0 10 950 ±10 3 FB6 BR 6 Assault Rifle 7.62 X 51 mm FJ/PB/SC 9.5 10 820 ±10 3 FB7 BR 7 7.62 X 5 mm (AP) FJ/PB/HC1 9.8 10 830 ±10 3 SG 1 12/70 Brenneke LB 15.6 10 420 ±10 1 Shotgun SG 2 12/70 Brenneke LB 15.6 10 420 ±10 3

8 ΒLAST RESISTANT GLAZING SYSTEMS Blast resistant systems have been certified in accordance with the EN 13123:2004 and EN 13541:2012 standards. GLASSCON offers a wide range of solutions for doors, windows and curtain walls against blast threat levels as part of our innovative security product range. Test methods for classification of the blast resistance of frame and glazing include tests that submit samples to various pressure levels to obtain different classification levels from EXR1 to EXR5 and ER1 to ER4. Key Features Internal or external use Increased mechanical strength and durability Slim sightlines and large expanses of glass Excellent anti-uv characteristics CE marking Options: thermal insulation, soundproofing, fire protection Applicable standards & classification levels EN 13123-2:2004 Windows, doors, and shutters. Explosion resistance. Requirements and classification. Range test EN 13541: 2012 Glass in building. Security glazing. Testing and classification of resistance against explosion pressure Classification Blast resistant safety systems Class Load mass (kg) Firing distance Load height (mm) EXR 1 3 5 500 ±50 EXR 2 3 3 500 ±50 EXR 3 12 5.5 800 ±50 EXR 4 12 4 800 ±50 EXR 5 20 4 800 ±50 Classification Blast resistant glazing Class Max pressure of reflected shock wave Pv (kpa) Specific positive impulse I (kpa. ms) Duration of positive pressure phase t (ms) ER 1 50 Pv 100 370 I 900 20 ER 2 100 Pv 150 900 I 1.500 20 ER 3 150 Pv 200 1.500 I 2.200 20 ER 4 200 Pv 250 2.200 I 3.200 20

9 FIRE RATED & SMOKE PROOF GLAZING SYSTEMS Fire safety systems have been certified in accordance with the EN 1634-3:2004 and EN 13501-2:2003 standards. GLASSCON offers complete fire protection solutions for doors, windows and curtain walls with fire resistance and smoke proofing properties. Test methods for classification of the fire resistance of doors and screening include fire tests that depending on the system s ability to withstand fire exposure and heat radiation to the non-fire side, obtain different classification levels from E to EI. Key Features Internal or external use Increased mechanical strength and durability Slim sightlines and large expanses of glass Excellent anti-uv characteristics CE marking Options: thermal insulation, soundproofing Applicable standards & classification levels EN 1634-3:2004 Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware. Smoke control test for door and shutter assemblies EN 13501-2: 2003 Fire classification of construction products and building elements. Classification using data from fire resistance tests, excluding ventilation services Classification Fire rated & smoke proof glazing systems Class E EW EI Time (min.) 30 45 60 90 120 30 45 60 90 120 30 45 60 90 120 Doors Sliding Doors Curtain walls Minimal frame E Class Integrity Prevents the spread of flames, toxic gases and smoke to the non-fire side. EW Class Integrity & Low Radiation Prevents the spread of flames and controls the heat radiation transmission to the non-fire side. EI Class Integrity & Insulation Prevents the spread of flames and the heat radiation transmission to the non-fire side. Fire rating Smoke resistant

GLASSCON GmbH 2017

GLASSCON GmbH Mergenthalerallee 77, 65760 Eschborn, Germany +49(0)61967889560 sales@glasscon.com www.glasscon.com Certified / Approved by: