NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Similar documents
COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

NEXT DL NEXT DL. rcgroupairconditioning

next p dw next p dw rcgroupairconditioning

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

next evo cw next evo cw rcgroupairconditioning

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

PYXIS U PYXIS U. rcgroupairconditioning

nemo a hp rcgroupairconditioning R410A

unico pf unico pf rcgroupairconditioning

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

pyxis u pyxis ua NEW rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

kw COOLING kw HEATING

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

i-next DX kw FULL INVERTER direct expansion air conditioners for IT Cooling. To be matched with remote air-cooled condenser. rcitcooling.

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

next DX.U.S* 052.Z2.H6.DC

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

21,8 222 kw COOLING 25,2 236 kw HEATING

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

KELVIN Clim F497. Kelvin air conditioning

rcgroup.it Flooded evaporator Refrigerant charge HFO1234ze, GWP<1 Low noise Minimum starting current EER up to 5,41 ESEER up to 9,10

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

kw. technicalcatalogue

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

2013 Product Range Precision Air Conditioners (CRAC)

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

frigo turbo FL Chillers

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

YORK Close Control units

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Chilled Water Precision Air Conditioner for Critical Application

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

CHAPTER 6 CONDENSING UNITS

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Aquaflair. Residential and Industrial Cooling Systems

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

LZA High efficiency air to water heat pumps with HP compressor

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Aquaflair TRAC-TRAF-TRAH

DATATECH. Precision air conditioners for technological environments 6 220

RC GROUP. MULTIPLO.A.STD/ELN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans R407C. SCROLL compressors kw

Air cooled industrial chillers

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

EDPAC International Close Control Air Conditioning Products E


YORK YC-P Series Close Control Air Conditioners

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

GLIDER_. air cooled liquid chilled chillers / heat pumps

TECNAIR LV C series Close control air conditioners

Transcription:

: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision air conditioner. 20 models available, 2 versions for a wide selection opportunity. EER up to 4,47. On/off scroll compressors. Single and double refrigerant circuit. R410A Refrigerant charge. rotary compressor (size E1, E2). AC plug-fans (size E3, E4, E5, E6, E7, E8). OVER and UNDER versions. Suitable for indoor installation. MAIN BENEFITS Units with single and double refrigerant circuits. Availability of remote condensers with axial fans (TEAM MATE series) and with plug fans (TEAM MATE PF series). High EER. Availability of EC plug-fans. Availability of electronic expansion valves. Availability of electric heater. Availability of steam humidifier. Availability of hot water heating coil. Availability of extra circuit heating coil. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTALLATION The machines are designed for indoor installation. REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEAM MATE series) or plug-fans (TEAM MATE PF series). WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 70%RH maximum relative humidity. 1 9 6 3 2 0 1 3 fiftycoolyears RCGROUP SpA G_ITC_RCW8.4 65

MAIN COMPONENTS FRAMEWORK Base in aluminium extrusion, painted with epoxy powders. Colour RAL 9005; Frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals for the panels. Colour RAL 9005; Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour RAL 7016 hammered; Panels insulated with polyurethane foam and seals to ensure air tight. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. Air flow OVER version: - Air intake from the front through honeycomb type grille and air delivery from the top. Air flow UNDER version: - Air intake from the top and air delivery from the bottom. Compartment for electrical panel on unit front for direct access to control and regulation devices; FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN 779-2002). Air filters access: OVER version - Frontal access for all machines UNDER version - For machines size E1 E2 E3 frontal access - For machine size E4 E5 E67 E7 E8 access from upper side IT Cooling ELECTRICAL PANEL In accordance with EN60204-1 norms, suitable for indoor installation, complete wit: Main switch with door lock safety on frontal panel;. Magnetothermic switches for supply fans. The supply fans equipped with EC electric motor and don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General Alarm 1 - Voltage free contact for supply fans status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N. CONTROL SYSTEM Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes: Built-in clock for alarms date and time displaying and storing; Built-in memory for the storing of the intervened events (up to 100 events recorded); Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BACnet for Ethernet (SNMP- TCP/IP), BACnet for MS/TP). The electronic cards are optional accessories; Main components hour-meter; Non-volatile Flash memory for data storage in case of power supply faulty; Menu with protection password; LAN connection (max 15 units). ON / OFF COMPRESSORS SECTION Units size E1 and E2: Rotary vane compressors for R410A refrigerant 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. Units size E3, E4, E5, E6, E7 and E8 Scroll rotary compressors with spiral profile optimized for R410A refrigerant. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel or peralluman. Condensate tray in peralluman with PVC flexible discharge pipe. Temperature sensors on air intake with control and regulation functions. Temperature sensors on air delivery with function of temperature display. REFRIGERANT CIRCUIT Components for each refrigerant circuit: Mechanical expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410A refrigerant charge and lubricant oil. Valves on gas delivery and liquid return for coupling to remote air cooled condenser. 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. TO BE MATCHED WITH REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEAM MATE series) or plug-fans (TEAM MATE PF series). FANS SECTION The fan section is contained within the machine and includes: Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Impeller in composite material exempt from rust formation. AC type electric motor with fixed speed. Fan guard with rubber support (UNDER version) TEAM MATE TEAM MATE PF 66 G_ITC_RCW8.4 RCGROUP SpA 19632013 fiftycoolyears

IT Cooling COMMON OPTIONAL ACCESSORIES TEAM MATE remote condenser TEAM MATE PF remote condenser 213 - Team Mate electrical power supply by internal unit 810 - Floor stand Hmax=350 mm 811 - Floor stand Hmax=450 mm 812 - Floor stand Hmax=510 mm 215 - Disposal F5 efficiency air filter 832 - Air supply plenum with F6 filters 833 - Air supply plenum with F7 filters 835 - Air supply plenum with F9 filters 836 - Air supply plenum with sound absorber Air discharge plenum with frontal and lateral grilles Air discharge plenum with frontal grille 761 - Air supply plenum with 5 closed sides 808 - Sandwich panels 945 -Air return plenum with Free Cooling damper 405 - Extra-Circuit system 514 - Water heater + 2 way valve 321 - Steam humidifier 1015 - Incresed umidifier 865 - Phases sequence relay 310 - Electric heater 1014- Increased electrical heater 909 - Clogged filters alarm 911 - Water presence alarm 913 - Additional water sensor (kit) 860 - T/rH sensor on air return 866 - T/rH external sensor 867 - T/rH remote sensor 610 - Noise deading cup on compressor 606 - Compr. power factor capacitor - 0,9 260 - Liquid solenoid valve 220 - Electronic expansion valve 101 - EC fan 923 - RC-Com MBUS/JBUS Serial board 926 - LON Serial board 931 - BACnet Ethernet - SNMP - TCP/IP Serial board 932 - BACnet MS/TP Serial board 1011 - Double serial interface 958 - Emergency microprocessor supply 863 - Remote terminal shared 930 - Remote graphic terminal kit 962 - Kit modem GSM 957 - Plantwatch without modem RC CLOUD PLATFORM E2 E3 E4 E5 E6 E7 E8 - - - OPTIONAL ACCESSORIES - OVER VERSION ONLY 848 - Condensate discharge system (kit) 807 - Blind frontal pannel 831 - Plenum with frontal grille and sound absorber 805 - Bottom panel H0 H1 H2 H3 H4 H5 H5 OPTIONAL ACCESSORIES - UNDER VERSION ONLY Air return plenum with sound absorber 848 - Condensate discharge system (kit) 849 - Condensate discharge system 843 - Motorized damper with frame H0 H1 H2 H3 H4 H5 H5 - - - - - - - available accessory; - not available accessory 19632013 fiftycoolyears RCGROUP SpA G_ITC_RCW8.4 67

TECHNICAL DATA MODEL IT Cooling 007 P1 009 P1 011 P1 014 P1 016 P1 020 P1 022 P1 026 P1 032 P1 037 P1 041 P1 COOLING CAPACITY (1) Total Sensible SHR / Unit power input Supply fans n. Air flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Air filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FLA) A Unit starting current (LRA) A Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) n. TEAM MATE TEAM MATE PF Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø MODEL COOLING CAPACITY (1) Total Sensible SHR / Unit power input Supply fans n. Air flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Air filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FLA) A Unit starting current (LRA) A Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) n. TEAM MATE TEAM MATE PF Refrigerant connections 68 E1 E1 E1 E2 E2 E3 E3 E3 E4 E4 E4 7,3 8,8 10,2 13,5 14,5 19,7 21,7 25,8 31,9 36,0 40,7 7,0 8,4 9,7 12,8 13,8 18,8 20,6 24,3 30,4 33,0 38,8 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,94 0,95 0,92 0,95 1,73 2,16 2,62 3,39 3,78 4,41 5,34 6,55 7,42 8,35 9,78 2500 2700 2800 4000 4200 5700 6100 6400 8450 8450 10350 20 20 20 20 20 20 20 20 20 20 20 180 130 110 100 55 310 240 190 20 20 20 rotary rotary rotary rotary rotary scroll scroll scroll scroll scroll scroll 1 1 1 1 1 2 2 2 2 2 2 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 3,2 3,2 3,2 3,4 3,4 4,0 4,0 4,0 5,7 5,7 8,6 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 6,1 7,0 7,2 8,5 9,1 15,4 18,8 20,1 22,2 25,7 30,4 33,3 40,3 37,5 54,5 54,5 66,9 77,9 103,9 130,9 141,9 122,0 4,22 4,07 3,89 3,98 3,84 4,47 4,06 3,94 4,30 4,31 4,16 58,0 59,6 60,4 62,6 63,6 63,5 65,0 66,0 72,0 75,1 71,2 49,8 50,2 51,9 51,3 53,0 53,9 57,7 55,1 57,8 58,9 58,8 40,2 41,4 42,4 40,4 41,7 42,4 45,5 44,0 48,6 51,3 49,4 50,1 52,3 52,3 50,5 52,0 52,5 55,2 54,3 58,9 61,4 59,7 40,9 42,1 43,2 41,3 42,9 43,4 46,3 45,1 49,6 52,0 50,5 220 221 228 260 265 300 305 305 410 415 427 230 231 238 270 275 320 325 325 420 425 437 M 11 M 11 M 11 M 14 M 17 M 25 M 25 M 30 M 35 M 45 M 45 T 11 T 11 T 11 T 14 T 21 T 24 T 24 T 33 T 38 T 44 T 44 12 12 12 16 16 16 16 22 22 22 22 12 12 12 12 12 16 16 16 16 16 22 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 045 P1 039 P2 048 P2 055 P2 062 P2 075 P2 082 P2 092 P2 102 P2 D D D D D D D D E4 E5 E5 E6 E6 E7 E7 E8 E8 44,3 36,5 47,1 54,5 61,3 74,6 81,3 89,9 102,0 40,5 34,1 42,9 51,9 58,4 71,1 76,2 81,4 89,6 0,91 0,93 0,91 0,95 0,95 0,95 0,94 0,91 0,88 10,78 8,59 11,69 13,20 14,77 17,68 19,59 21,56 25,37 1 1 1 2 2 2 2 2 2 10350 8750 10850 15000 15600 20000 20000 20900 20900 20 20 20 20 20 20 20 20 20 20 20 20 137 70 20 20 20 20 scroll scroll scroll scroll scroll scroll scroll scroll scroll 1 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 3 3 3 3 4 4 5 5 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410A R410A R410A R410A R410A R410A R410A R410A R410A 8,6 9,0 9,0 9,8 9,8 16,2 16,2 17,4 17,4 1 2 2 2 2 2 2 2 2 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 36,7 27,8 35,7 40,1 44,3 53,7 60,9 73,5 79,8 144,0 78,7 94,0 123,0 152,0 168,6 151,0 179,0 216,0 4,11 4,25 4,03 4,13 4,15 4,22 4,15 4,17 4,02 71,2 75,2 74,1 71,8 72,6 72,3 72,3 74,7 74,7 57,6 59,0 59,2 58,5 60,3 60,6 61,3 62,6 63,4 48,0 51,5 50,5 48,7 49,9 50,7 51,0 53,0 53,3 59,9 61,6 60,8 59,0 60,1 61,0 61,3 63,3 63,6 50,8 52,1 51,4 49,7 50,9 51,8 52,2 54,1 54,4 435 520 530 610 630 688 695 785 785 435 530 540 620 640 745 750 845 845 M 50 M 25 M 25 M 30 M 35 M 45 M 45 M 50 M 60 T 58 T 24 T 33 T 33 T 38 T 38 T 58 T 58 T69 Gas delivery ODS Ø 22 2x16 2x16 2x22 2x22 2x22 2x22 2x22 2x22 Liquid return ODS Ø 22 2x16 2x16 2x16 2x16 2x22 2x22 2x22 2x22 Hydraulic connections - Condensate discharge F Ø 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CAPACITY DOES NOT CONSIDER THE SUPPLY FAN MOTOR THERMAL LOAD 1. Characteristics referred to entering air at 24 C-45%RH; 45 C condensing temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. For matching to other remote air cooled condensers please refer to RC WORLD selection program (**) The remote condenser has separated power supply G_ITC_RCW8.4 RCGROUP SpA 19632013 fiftycoolyears

IT Cooling TECHNICAL DATA - OPTIONAL ACCESSORIES Electric heater Capacity Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity Electric heater Capacity Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity 007 P1 009 P1 011 P1 014 P1 016 P1 020 P1 022 P1 026 P1 032 P1 037 P1 E1 E1 E1 E2 E2 E3 E3 E3 E4 E4 5,1 5,1 5,1 5,1 5,1 6,0 6,0 6,0 9,0 9,0 1,0 1,0 1,0 1,0 1,0 2,0 2,0 2,0 3,0 3,0 3 3 3 3 3 3 3 3 8 8 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 6,0 6,0 10,4 11,0 11,3 16,7 17,4 23,7 25,0 25,8 35,8 35,8 9,6 10,0 10,3 15,3 15,7 21,8 22,7 23,5 32,7 32,7 22,9 24,1 24,7 33,6 34,7 48,8 51,1 52,7 75,1 75,1 041 P1 045 P1 039 P2 D 048 P2 D 055 P2 D 062 P2 D 075 P2 D 082 P2 D 092 P2 D 102 P2 D E4 E4 E5 E5 E6 E6 E7 E7 E8 E8 9,0 9,0 13,5 13,5 13,5 13,5 18,0 18,0 18,0 18,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 8 8 8 8 8 8 8 8 8 8 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 41,5 41,5 42,4 50,0 61,1 61,1 94,2 94,2 105,0 105,0 37,7 37,7 36,8 44,2 55,4 55,4 80,0 80,0 87,1 87,1 86,2 86,2 85,0 98,8 131,0 134,0 160,0 160,0 175,0 175,0 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at 75/60 C 19632013 fiftycoolyears RCGROUP SpA G_ITC_RCW8.4 69

IT Cooling DIMENSIONS (mm) DIMENSIONS (mm) a b c E1 650 675 1925 E2 785 675 1925 E3 1085 775 1925 E4 1305 930 1980 E5 1630 930 1980 E6 1875 930 1980 E7 2175 930 1980 E8 2499 930 1980 c a b 70 G_ITC_RCW8.4 RCGROUP SpA 19632013 fiftycoolyears