: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision air conditioner. 20 models available, 2 versions for a wide selection opportunity. EER up to 4,47. On/off scroll compressors. Single and double refrigerant circuit. R410A Refrigerant charge. rotary compressor (size E1, E2). AC plug-fans (size E3, E4, E5, E6, E7, E8). OVER and UNDER versions. Suitable for indoor installation. MAIN BENEFITS Units with single and double refrigerant circuits. Availability of remote condensers with axial fans (TEAM MATE series) and with plug fans (TEAM MATE PF series). High EER. Availability of EC plug-fans. Availability of electronic expansion valves. Availability of electric heater. Availability of steam humidifier. Availability of hot water heating coil. Availability of extra circuit heating coil. Complete set of optional accessories: filters, plenum, panels, stand. Easily of maintenance. INDOOR INSTALLATION The machines are designed for indoor installation. REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEAM MATE series) or plug-fans (TEAM MATE PF series). WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 70%RH maximum relative humidity. 1 9 6 3 2 0 1 3 fiftycoolyears RCGROUP SpA G_ITC_RCW8.4 65
MAIN COMPONENTS FRAMEWORK Base in aluminium extrusion, painted with epoxy powders. Colour RAL 9005; Frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals for the panels. Colour RAL 9005; Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour RAL 7016 hammered; Panels insulated with polyurethane foam and seals to ensure air tight. Hinged front panels with quick release removal system. Total front access for routine maintenance. Removable lateral and back side panels. Air flow OVER version: - Air intake from the front through honeycomb type grille and air delivery from the top. Air flow UNDER version: - Air intake from the top and air delivery from the bottom. Compartment for electrical panel on unit front for direct access to control and regulation devices; FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN 779-2002). Air filters access: OVER version - Frontal access for all machines UNDER version - For machines size E1 E2 E3 frontal access - For machine size E4 E5 E67 E7 E8 access from upper side IT Cooling ELECTRICAL PANEL In accordance with EN60204-1 norms, suitable for indoor installation, complete wit: Main switch with door lock safety on frontal panel;. Magnetothermic switches for supply fans. The supply fans equipped with EC electric motor and don t require contactors. Transformer for auxiliary circuit and microprocessor supply. Terminals: OUTLETS - Voltage free deviating contact for General Alarm 1 - Voltage free contact for supply fans status. INLETS - Emergency unit stop with signalling on display (external alarm). - External enabling. Power supply 400/3/50+N. CONTROL SYSTEM Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes: Built-in clock for alarms date and time displaying and storing; Built-in memory for the storing of the intervened events (up to 100 events recorded); Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BACnet for Ethernet (SNMP- TCP/IP), BACnet for MS/TP). The electronic cards are optional accessories; Main components hour-meter; Non-volatile Flash memory for data storage in case of power supply faulty; Menu with protection password; LAN connection (max 15 units). ON / OFF COMPRESSORS SECTION Units size E1 and E2: Rotary vane compressors for R410A refrigerant 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. Units size E3, E4, E5, E6, E7 and E8 Scroll rotary compressors with spiral profile optimized for R410A refrigerant. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Rubber supports. COOLING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Frame in galvanized steel or peralluman. Condensate tray in peralluman with PVC flexible discharge pipe. Temperature sensors on air intake with control and regulation functions. Temperature sensors on air delivery with function of temperature display. REFRIGERANT CIRCUIT Components for each refrigerant circuit: Mechanical expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Liquid receiver with accessories. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410A refrigerant charge and lubricant oil. Valves on gas delivery and liquid return for coupling to remote air cooled condenser. 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. TO BE MATCHED WITH REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEAM MATE series) or plug-fans (TEAM MATE PF series). FANS SECTION The fan section is contained within the machine and includes: Centrifugal fans with backward curved blades with wing profile, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Impeller in composite material exempt from rust formation. AC type electric motor with fixed speed. Fan guard with rubber support (UNDER version) TEAM MATE TEAM MATE PF 66 G_ITC_RCW8.4 RCGROUP SpA 19632013 fiftycoolyears
IT Cooling COMMON OPTIONAL ACCESSORIES TEAM MATE remote condenser TEAM MATE PF remote condenser 213 - Team Mate electrical power supply by internal unit 810 - Floor stand Hmax=350 mm 811 - Floor stand Hmax=450 mm 812 - Floor stand Hmax=510 mm 215 - Disposal F5 efficiency air filter 832 - Air supply plenum with F6 filters 833 - Air supply plenum with F7 filters 835 - Air supply plenum with F9 filters 836 - Air supply plenum with sound absorber Air discharge plenum with frontal and lateral grilles Air discharge plenum with frontal grille 761 - Air supply plenum with 5 closed sides 808 - Sandwich panels 945 -Air return plenum with Free Cooling damper 405 - Extra-Circuit system 514 - Water heater + 2 way valve 321 - Steam humidifier 1015 - Incresed umidifier 865 - Phases sequence relay 310 - Electric heater 1014- Increased electrical heater 909 - Clogged filters alarm 911 - Water presence alarm 913 - Additional water sensor (kit) 860 - T/rH sensor on air return 866 - T/rH external sensor 867 - T/rH remote sensor 610 - Noise deading cup on compressor 606 - Compr. power factor capacitor - 0,9 260 - Liquid solenoid valve 220 - Electronic expansion valve 101 - EC fan 923 - RC-Com MBUS/JBUS Serial board 926 - LON Serial board 931 - BACnet Ethernet - SNMP - TCP/IP Serial board 932 - BACnet MS/TP Serial board 1011 - Double serial interface 958 - Emergency microprocessor supply 863 - Remote terminal shared 930 - Remote graphic terminal kit 962 - Kit modem GSM 957 - Plantwatch without modem RC CLOUD PLATFORM E2 E3 E4 E5 E6 E7 E8 - - - OPTIONAL ACCESSORIES - OVER VERSION ONLY 848 - Condensate discharge system (kit) 807 - Blind frontal pannel 831 - Plenum with frontal grille and sound absorber 805 - Bottom panel H0 H1 H2 H3 H4 H5 H5 OPTIONAL ACCESSORIES - UNDER VERSION ONLY Air return plenum with sound absorber 848 - Condensate discharge system (kit) 849 - Condensate discharge system 843 - Motorized damper with frame H0 H1 H2 H3 H4 H5 H5 - - - - - - - available accessory; - not available accessory 19632013 fiftycoolyears RCGROUP SpA G_ITC_RCW8.4 67
TECHNICAL DATA MODEL IT Cooling 007 P1 009 P1 011 P1 014 P1 016 P1 020 P1 022 P1 026 P1 032 P1 037 P1 041 P1 COOLING CAPACITY (1) Total Sensible SHR / Unit power input Supply fans n. Air flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Air filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FLA) A Unit starting current (LRA) A Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) n. TEAM MATE TEAM MATE PF Refrigerant connections Gas delivery ODS Ø Liquid return ODS Ø Hydraulic connections - Condensate discharge F Ø MODEL COOLING CAPACITY (1) Total Sensible SHR / Unit power input Supply fans n. Air flow m 3 /h Nominal external static pressure Pa Fans max external static pressure Pa Compressors Quantity n. Air filters n. Efficiency Refrigerant Refrigerant charge (2) Gas circuits n. Power supply (**) Max operating current (FLA) A Unit starting current (LRA) A Energy efficiency indexes (1) EER / Sound pressure level - ISO 3744 (3) On air delivery Under/Over On air intake Over Irradiated Over On air intake Under On front side Under Net weight Over Net weight Under Remote condenser (4) n. TEAM MATE TEAM MATE PF Refrigerant connections 68 E1 E1 E1 E2 E2 E3 E3 E3 E4 E4 E4 7,3 8,8 10,2 13,5 14,5 19,7 21,7 25,8 31,9 36,0 40,7 7,0 8,4 9,7 12,8 13,8 18,8 20,6 24,3 30,4 33,0 38,8 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,94 0,95 0,92 0,95 1,73 2,16 2,62 3,39 3,78 4,41 5,34 6,55 7,42 8,35 9,78 2500 2700 2800 4000 4200 5700 6100 6400 8450 8450 10350 20 20 20 20 20 20 20 20 20 20 20 180 130 110 100 55 310 240 190 20 20 20 rotary rotary rotary rotary rotary scroll scroll scroll scroll scroll scroll 1 1 1 1 1 2 2 2 2 2 2 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A 3,2 3,2 3,2 3,4 3,4 4,0 4,0 4,0 5,7 5,7 8,6 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 6,1 7,0 7,2 8,5 9,1 15,4 18,8 20,1 22,2 25,7 30,4 33,3 40,3 37,5 54,5 54,5 66,9 77,9 103,9 130,9 141,9 122,0 4,22 4,07 3,89 3,98 3,84 4,47 4,06 3,94 4,30 4,31 4,16 58,0 59,6 60,4 62,6 63,6 63,5 65,0 66,0 72,0 75,1 71,2 49,8 50,2 51,9 51,3 53,0 53,9 57,7 55,1 57,8 58,9 58,8 40,2 41,4 42,4 40,4 41,7 42,4 45,5 44,0 48,6 51,3 49,4 50,1 52,3 52,3 50,5 52,0 52,5 55,2 54,3 58,9 61,4 59,7 40,9 42,1 43,2 41,3 42,9 43,4 46,3 45,1 49,6 52,0 50,5 220 221 228 260 265 300 305 305 410 415 427 230 231 238 270 275 320 325 325 420 425 437 M 11 M 11 M 11 M 14 M 17 M 25 M 25 M 30 M 35 M 45 M 45 T 11 T 11 T 11 T 14 T 21 T 24 T 24 T 33 T 38 T 44 T 44 12 12 12 16 16 16 16 22 22 22 22 12 12 12 12 12 16 16 16 16 16 22 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 045 P1 039 P2 048 P2 055 P2 062 P2 075 P2 082 P2 092 P2 102 P2 D D D D D D D D E4 E5 E5 E6 E6 E7 E7 E8 E8 44,3 36,5 47,1 54,5 61,3 74,6 81,3 89,9 102,0 40,5 34,1 42,9 51,9 58,4 71,1 76,2 81,4 89,6 0,91 0,93 0,91 0,95 0,95 0,95 0,94 0,91 0,88 10,78 8,59 11,69 13,20 14,77 17,68 19,59 21,56 25,37 1 1 1 2 2 2 2 2 2 10350 8750 10850 15000 15600 20000 20000 20900 20900 20 20 20 20 20 20 20 20 20 20 20 20 137 70 20 20 20 20 scroll scroll scroll scroll scroll scroll scroll scroll scroll 1 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 3 3 3 3 4 4 5 5 G4 G4 G4 G4 G4 G4 G4 G4 G4 R410A R410A R410A R410A R410A R410A R410A R410A R410A 8,6 9,0 9,0 9,8 9,8 16,2 16,2 17,4 17,4 1 2 2 2 2 2 2 2 2 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 36,7 27,8 35,7 40,1 44,3 53,7 60,9 73,5 79,8 144,0 78,7 94,0 123,0 152,0 168,6 151,0 179,0 216,0 4,11 4,25 4,03 4,13 4,15 4,22 4,15 4,17 4,02 71,2 75,2 74,1 71,8 72,6 72,3 72,3 74,7 74,7 57,6 59,0 59,2 58,5 60,3 60,6 61,3 62,6 63,4 48,0 51,5 50,5 48,7 49,9 50,7 51,0 53,0 53,3 59,9 61,6 60,8 59,0 60,1 61,0 61,3 63,3 63,6 50,8 52,1 51,4 49,7 50,9 51,8 52,2 54,1 54,4 435 520 530 610 630 688 695 785 785 435 530 540 620 640 745 750 845 845 M 50 M 25 M 25 M 30 M 35 M 45 M 45 M 50 M 60 T 58 T 24 T 33 T 33 T 38 T 38 T 58 T 58 T69 Gas delivery ODS Ø 22 2x16 2x16 2x22 2x22 2x22 2x22 2x22 2x22 Liquid return ODS Ø 22 2x16 2x16 2x16 2x16 2x22 2x22 2x22 2x22 Hydraulic connections - Condensate discharge F Ø 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CAPACITY DOES NOT CONSIDER THE SUPPLY FAN MOTOR THERMAL LOAD 1. Characteristics referred to entering air at 24 C-45%RH; 45 C condensing temperature. 2. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 3. Noise level at 1 meter in free field (external static pressure 50 Pa) 4. For matching to other remote air cooled condensers please refer to RC WORLD selection program (**) The remote condenser has separated power supply G_ITC_RCW8.4 RCGROUP SpA 19632013 fiftycoolyears
IT Cooling TECHNICAL DATA - OPTIONAL ACCESSORIES Electric heater Capacity Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity Electric heater Capacity Humidifier Steam capacity /h Power input Extra circuit coil (1) Total cooling capacity Sensible cooling capacity Heating coil (2) Heating capacity 007 P1 009 P1 011 P1 014 P1 016 P1 020 P1 022 P1 026 P1 032 P1 037 P1 E1 E1 E1 E2 E2 E3 E3 E3 E4 E4 5,1 5,1 5,1 5,1 5,1 6,0 6,0 6,0 9,0 9,0 1,0 1,0 1,0 1,0 1,0 2,0 2,0 2,0 3,0 3,0 3 3 3 3 3 3 3 3 8 8 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 6,0 6,0 10,4 11,0 11,3 16,7 17,4 23,7 25,0 25,8 35,8 35,8 9,6 10,0 10,3 15,3 15,7 21,8 22,7 23,5 32,7 32,7 22,9 24,1 24,7 33,6 34,7 48,8 51,1 52,7 75,1 75,1 041 P1 045 P1 039 P2 D 048 P2 D 055 P2 D 062 P2 D 075 P2 D 082 P2 D 092 P2 D 102 P2 D E4 E4 E5 E5 E6 E6 E7 E7 E8 E8 9,0 9,0 13,5 13,5 13,5 13,5 18,0 18,0 18,0 18,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 8 8 8 8 8 8 8 8 8 8 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 6,0 41,5 41,5 42,4 50,0 61,1 61,1 94,2 94,2 105,0 105,0 37,7 37,7 36,8 44,2 55,4 55,4 80,0 80,0 87,1 87,1 86,2 86,2 85,0 98,8 131,0 134,0 160,0 160,0 175,0 175,0 1. Characteristics referred to entering air at 24 C 50%RH with chiller water at 7/12,5 C and 0% glycol 2. Characteristics referred to entering air at 20 C with hot water at 75/60 C 19632013 fiftycoolyears RCGROUP SpA G_ITC_RCW8.4 69
IT Cooling DIMENSIONS (mm) DIMENSIONS (mm) a b c E1 650 675 1925 E2 785 675 1925 E3 1085 775 1925 E4 1305 930 1980 E5 1630 930 1980 E6 1875 930 1980 E7 2175 930 1980 E8 2499 930 1980 c a b 70 G_ITC_RCW8.4 RCGROUP SpA 19632013 fiftycoolyears