Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system 4 4-pipe system Ducted Centrifugal fan Multi speed motor Heat exchanger up to 4 rows Reversible water connections ABS centrifugal fans Can be integrated into the ERGO Incorporable ioniser The Ductimax ducted unit has been conceived for air conditioning interiors where the installation of highperformance medium-head units with reduced overall dimensions is required. The range features models with air flows of from to 00 m /h. The heat exchanger enables Ductimax to be used under a whole variety of operating conditions. The weight-bearing structure in fact houses a - or 4-row exchanger which can be combined with an additional - or -row exchanger for exceptional performance even with low temperature differentials. The heat exchangers can be optimized for centralized applications such as district cooling. Ductimax is designed for horizontal ceiling installation. The main condensate drip tray is situated inside the structure of the unit and is at a positive pressure relative to the drain outlet to facilitate condensate drainage. A wide range of wall-mounted controllers is available, including controllers of an electromechanical type and microprocessor controllers with display. The use of MYCOMFORT MEDIUM and LARGE or EVO enables Ductimax to be connected to ERGO. Heating elements complete with safety devices are available to supplement the hydronic system. The action of the G air filter can be combined with an air ionisation system. available versions DM xx0 DS DM xx DS DM xx DS Unit for -pipe systems Unit for 4-pipe systems equipped with an additional -row exchanger for the hot water circuit Unit for 4-pipe systems equipped with an additional -row exchanger for the hot water circuit The structure makes it possible to combine a wide range of accessories on the air intake and outlet sides so as to obtain the optimal configuration of the unit. 86 galletti.com VM6600087-0
DUCTIMAX - 8 kw MAIN COMPONENTS Structure Heat exchanger Built from galvanised steel sheet, heat and sound insulated by means of Class self-extinguishing panels. Reduced height to facilitate installation in a horizontal position in a false ceiling. The structure incorporates a drip tray and condensate drain outlet. Electric motor Single-phase asynchronous multi-speed electric motor with permanently connected capacitor and thermal protector, mounted on vibration-damping supports. High efficiency and 4 rows heat exchanger made with copper piping and aluminium fins blocked to pipings by mechanical expansion, provided with brass manifolds and air vent valve. The heat exchanger usually comes with water connections mounted on the left, but it can be turned by 80. High-efficiency heat exchangers optimized for district cooling applications are available on request. Fans Double suction centrifugal fans made with ABS or aluminium, with statically and dynamically balanced forward-curving blades, directly coupled to the electric motor. Air filter Washable air filter, made of acrylic fibre, filtration class G or G, applied on the air intake; may be pulled out from below. Hydronic indoor units - DUCTIMAX ACCESSORIES ELECTROMECHANICAL CONTROL PANELS CD Recess wall-mounted speed selector CDE Wall-mounted speed selector TD Wall-mounted speed selector, thermostat and summer/winter selecting switch TDC Wall-mounted speed selector and thermostat TD4T Wall-mounted speed selector, thermostat and summer/winter selecting switch for or 4-pipe systems with valves TC Thermostat for minimum water temperature in heating mode, mounted on the heat exchanger TA Ambient thermostat TA Ambient thermostat with summer/winter selecting switch KP Power interface for connecting in parallel up to 4 fan coils to one controller MICROPROCESSOR ELECTRONIC CONTROL PANELS MCBE MyComfort base electronic controller with display MCME MyComfort medium electronic controller with display MCLE MyComfort large electronic controller with display DIST MyComfort controller spacer for wall mounting EVODISP Evo Clock Remote display EVOVOARD EVO 0V circuit board LED50 Recess wall-mounted electronic controller with display CO (B-G-W) Plate for LED50, white W (RAL 70), grey G (RAL 900), black B (RAL 9005) MCSWE Water sensor for EVO, MYCOMFORT BASE, MEDIUM, LARGE, and LED 50 microprocessor controllers MCSUE Humidity sensor for EVO, MYCOMFORT MEDIUM and LARGE microprocessor controller PLENUM AND AIR INLET AND OUTLET CONNECTORS PMA PMAC PAF RD Uninsulated air outlet/intake plenum with Ø 00 mm collars Insulated air outlet/intake plenum with Ø 00 mm collars Uninsulated front air intake plenum with Ø 00 mm collars Straight uninsulated air inlet/outlet connector RDC R90 R90C MAFO Straight insulated air inlet/outlet connector 90 uninsulated air inlet/outlet connector 90 insulated air inlet/outlet connector Air intake module with G4 undulated filter CONNECTION HOSES AND PLUGS TFA TFM TP Uninsulated hose Ø 00 mm Insulated hose Ø 00 mm Plastic plug Ø 00 mm AIR OUTLET AND INTAKE DUCTS CA CAF CM Air intake duct with honeycomb grille Air intake duct with honeycomb grille and G filter Insulated air outlet duct, with -way grille AIR OUTLET AND INTAKE GRILLES GM GA Aluminium air outlet grille with -row fins, with frame Aluminium air intake grille, with frame MOTOR DRIVEN ON/OFF AND MODULATING VALVES VK ON-OFF -way motor driven valve (0V and 4V actuator), with hydraulic kit for standard and DF heat exchanger VK Modulating -way motor driven valve (4V actuator), with hydraulic kit for standard and DF heat exchanger KV ON-OFF -way motor driven valve (0V and 4V actuator), with hydraulic kit for standard and DF heat exchanger KVM Modulating -way motor driven valve (4V actuator), with hydraulic kit for standard and DF heat exchanger ACCESSORIES VRC Auxiliary external drip tray. RE Additional heating element for installation on board the unit, complete with safety devices KSC Condensate drainage pump VM6600087-0 galletti.com 87
Duct unit DUCTIMAX Rated technical data DM DS 0 40 0 40 Fan speed min med max min med max min med max min med max 4 6 4 6 5 7 5 7 Air flow E m /h 8 46 76 8 46 76 7 75 4 7 75 4 Available static pressure Pa 5 50 6 5 50 6 9 50 77 9 50 77 Power supply V-ph-Hz 0--50 Power input (E) W 4 57 8 4 57 8 4 06 4 06 Total cooling capacity () kw,,78,98,8,97,8,0,97,8,9,8,64 Sensible cooling capacity () kw 0,77,8,4 0,80,6,5 0,9,4,70 0,96,5,84 Water flow l/h 9 06 8 0 8 74 8 40 8 74 4 Water pressure drop () kpa 5 6 7 8 6 8 4 8 Heating capacity () kw,,8,9,7,8,64,60,8,8,69,64, Water flow l/h 94 4 5 0 49 89 8 5 48 48 89 47 Water pressure drop () kpa 4 5 6 7 5 6 7 0 row DF heating capacity () kw,56,4,8,56,4,8,79,9,69,79,9,69 row DF Water flow l/h 7 98 09 7 98 09 58 09 8 58 09 8 row DF Water pressure drop () kpa 4 4 row DF heating capacity () kw,6,50,78,6,50,78,6,8 4,5,6,8 4,5 row DF Water flow l/h 9 06 9 06 7 5 9 7 5 9 DF row DF Water pressure drop () kpa 7 8 7 8 4 8 4 8 Standard coil - number of rows n 4 4 Total sound power level db(a) 6 48 5 6 48 5 6 50 58 6 50 58 Inlet + radiated sound power level db(a) 4 46 50 4 46 50 4 48 56 4 48 56 Outlet sound power level db(a) 49 49 47 55 47 55 DM DS 0 40 40 440 Fan speed min med max min med max min med max min med max 6 7 6 7 4 7 4 7 Air flow E m /h 94 60 40 94 60 40 05 5 65 05 5 65 Available static pressure Pa 4 50 6 4 50 6 7 50 76 7 50 76 Power supply V-ph-Hz 0--50 Power input (E) W 4 47 06 4 47 06 76 4 9 76 4 9 Total cooling capacity () kw,47,6,6,60,77,07,00,,87,7,9 4,64 Sensible cooling capacity () kw,05,77,97,0,9,4,50,5,00,65,75,7 Water flow l/h 5 407 0 74 475 56 4 569 66 407 67 796 Water pressure drop () kpa 5 5 7 9 8 6 4 8 Heating capacity () kw,88,59,5,9,69,7,78 4,40 5,,8 4,47 5, Water flow l/h 8 479 56 8 497 547 4 569 66 407 67 796 Water pressure drop () kpa 5 6 6 7 7 9 4 9 row DF heating capacity () kw,8,5,75,8,5,75,8 4,6 4,8,8 4,6 4,8 row DF Water flow l/h 09 0 8 09 0 8 8 8 4 8 8 4 row DF Water pressure drop () kpa 4 4 4 4 6 7 6 7 row DF heating capacity () kw,0 5, 5,70,0 5, 5,70 4,6 7,0 8,0 4,6 7,0 8,0 row DF Water flow l/h 74 7 500 74 7 500 400 66 706 400 66 706 DF row DF Water pressure drop () kpa 6 7 6 7 5 0 5 0 Standard coil - number of rows n 4 4 Total sound power level db(a) 6 5 58 6 5 58 9 5 60 9 5 60 Inlet + radiated sound power level db(a) 4 50 56 4 50 56 7 50 58 7 50 58 Outlet sound power level db(a) 49 55 49 55 5 47 56 5 47 56 88 galletti.com VM6600087-0
DUCTIMAX - 8 kw Rated technical data DM DS 50 540 60 640 Fan speed min med max min med max min med max min med max 6 7 6 7 Air flow E m /h 7 687 760 7 687 760 4 70 8 047 70 8 Available static pressure Pa 50 6 50 6 40 50 60 40 50 60 Power supply V-ph-Hz 0--50 Power input (E) W 76 67 9 76 67 9 5 80 5 80 Total cooling capacity () kw, 4,9 4,8,54 4,95 5,4 6,6 6,97 7,5 7, 7,80 8,4 Sensible cooling capacity () kw,70,6,58,79,50,8 4,7 5,9 5,6 5,04 5,54 5,99 Water flow l/h 96 75 88 46 850 99 09 97 9 40 4 Water pressure drop () kpa 7 8 0 6 8 0 6 Heating capacity () kw,05 5,66 6,6,8 6,04 6,59 7,94 8,65 9,8 8,59 9,40 0, Water flow l/h 96 75 88 46 850 99 09 97 9 40 4 Water pressure drop () kpa 6 7 8 0 5 6 9 row DF heating capacity () kw,86 5,86 6,8,86 5,86 6,8 7,5 7,64 7,96 7,5 7,64 7,96 row DF Water flow l/h 8 55 544 8 55 544 66 670 699 66 670 699 row DF Water pressure drop () kpa 8 6 8 8 6 8 5 7 5 7 row DF heating capacity () kw 5,05 8,68 9,5 5,05 8,68 9,5,4,0,5,4,0,5 row DF Water flow l/h 44 760 84 44 760 84 999 056 098 999 056 098 DF row DF Water pressure drop () kpa 6 6 8 6 6 8 6 8 0 6 8 0 Standard coil - number of rows n 4 4 Total sound power level db(a) 9 55 60 9 55 60 59 6 69 59 6 69 Inlet + radiated sound power level db(a) 7 5 58 7 5 58 57 60 67 57 60 67 Outlet sound power level db(a) 5 5 56 5 5 56 55 58 65 55 58 65 Hydronic indoor units - DUCTIMAX () Water temperature 7- C, air temperature D.B. 7 C, W.B. 9 C (47% relative humidity) () Inlet water temperature 50 C, water flow rate same as in cooling mode, air temperature 0 C () Water temperature 70 / 60 C, air temperature 0 C (4) Sound power measured according to standards ISO 74 and ISO 74 (E) EUROVENT certified data VM6600087-0 galletti.com 89
Duct unit DUCTIMAX Dimensional drawings DUCTIMAX - 4 4.5 C 5 D 5 4.5 0 89.5 0 89.5 C A 5 D 5 7 E 7 60 575 A 7 E 7 07 07 95 6 4 5 499 4 4 6 05 86 9 79 50 6 5 5.5 05 86 9 79 60 575 95 6 5 499 4 6 50 6 5 40 5.5 00 DUCTIMAX 0-40 0-40 0-40 40-440 A 757 757 967 967 C 677 677 887 887 D 648 648 858 858 E 70 70 9 9 / / / / / / / / Ø 7 Ø 7 Ø 7 Ø 7 LEGEND Standard heat exchanger water connections Additional heat exchanger water connections Condensate drainage 90 galletti.com VM6600087-0
DUCTIMAX - 8 kw Dimensional drawings DUCTIMAX 5-6 4.5 9.5 0 4.5 9.5 0 7 7 096 5 066 5 77 7 7 685 096 5 066 5 77 7 7 685 6 8 6 8 0 06 4 68 597 50 86.5 09 09 06 4 68 597 50 86.5 60 60 09 09 60 60 Hydronic indoor units - DUCTIMAX 0 9 8 9 5.5 5.5 8 40 40 00 00 DUCTIMAX 50-540 60-640 /4 /4 /4 /4 Ø 7 Ø 7 LEGEND Standard heat exchanger water connections Additional heat exchanger water connections Condensate drainage VM6600087-0 galletti.com 9