DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Similar documents
The technical and dimensional data reported in this manual may be modified in view of any product improvement.

Galletti Hydronic indoor units

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Fan coil units with centrifugal fan

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Galletti. FLAT fan coil units.

Fan coil units with centrifugal fan. Fan coils with inverter BRUSHLESS motor. Fan coil units with centrifugal fan. Units for air conditioning system

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

technical data Fan coil unit FWB small duct unit

Blower-YEFB-020-3R-1maxVel

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

Fan coil units with centrifugal fan and BLDC motor

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

QTS SELECTION TECHNICAL BOOKLET

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Conditioning your ambient, maximising your comfort.

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

KPSW CONSOLE TERMINAL UNIT

Conditioning your ambient, maximising your comfort.

Fan Coil Range HYDRONIC TERMINALS

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

LOW STATIC HYDRONIC DUCTED UNIT

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

UCS UCS/M UCS/H UCS900

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

SIGMA PRISMA LOW BODY CONCEALED

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

FAN COIL UNITS LASER / LOW BODY / CONCEALED

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

INDEX. Main components 3. General features and description of the components 4

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AQUASNAP JUNIOR 30RHV

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

A NEW BEGINNING IN FAN COIL HISTORY

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

TopVent Design Handbook

Technical documentation Fan coil unit

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

The Sabiana. of Fan Coil

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

UniTrane Ductable Units D-line and B-Line

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Halton CHB Active chilled beam with boost function for bulkhead installation

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

High temperature air-to-water heat pumps

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Fan coils with Inverter Brushless motor (EC) Universal and floor installation FCZI_U

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Fan coil unit KL. Wall unit Ceiling unit

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Brochure EX

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

E U R O V E N T CERTIFIED PERFORMANCE

VERTICAL WATER RECESSED TERMINAL UNIT

CASSETTE UNIT. Comfort Circle

YFCN Fan Coil Unit centrifugal fan

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

HIWARM COMPACT kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

BRISE. Super-power for heating, cooling and ventilation.

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

NEW GREEN TECHNOLOGY

Transcription:

Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system 4 4-pipe system Ducted Centrifugal fan Multi speed motor Heat exchanger up to 4 rows Reversible water connections ABS centrifugal fans Can be integrated into the ERGO Incorporable ioniser The Ductimax ducted unit has been conceived for air conditioning interiors where the installation of highperformance medium-head units with reduced overall dimensions is required. The range features models with air flows of from to 00 m /h. The heat exchanger enables Ductimax to be used under a whole variety of operating conditions. The weight-bearing structure in fact houses a - or 4-row exchanger which can be combined with an additional - or -row exchanger for exceptional performance even with low temperature differentials. The heat exchangers can be optimized for centralized applications such as district cooling. Ductimax is designed for horizontal ceiling installation. The main condensate drip tray is situated inside the structure of the unit and is at a positive pressure relative to the drain outlet to facilitate condensate drainage. A wide range of wall-mounted controllers is available, including controllers of an electromechanical type and microprocessor controllers with display. The use of MYCOMFORT MEDIUM and LARGE or EVO enables Ductimax to be connected to ERGO. Heating elements complete with safety devices are available to supplement the hydronic system. The action of the G air filter can be combined with an air ionisation system. available versions DM xx0 DS DM xx DS DM xx DS Unit for -pipe systems Unit for 4-pipe systems equipped with an additional -row exchanger for the hot water circuit Unit for 4-pipe systems equipped with an additional -row exchanger for the hot water circuit The structure makes it possible to combine a wide range of accessories on the air intake and outlet sides so as to obtain the optimal configuration of the unit. 86 galletti.com VM6600087-0

DUCTIMAX - 8 kw MAIN COMPONENTS Structure Heat exchanger Built from galvanised steel sheet, heat and sound insulated by means of Class self-extinguishing panels. Reduced height to facilitate installation in a horizontal position in a false ceiling. The structure incorporates a drip tray and condensate drain outlet. Electric motor Single-phase asynchronous multi-speed electric motor with permanently connected capacitor and thermal protector, mounted on vibration-damping supports. High efficiency and 4 rows heat exchanger made with copper piping and aluminium fins blocked to pipings by mechanical expansion, provided with brass manifolds and air vent valve. The heat exchanger usually comes with water connections mounted on the left, but it can be turned by 80. High-efficiency heat exchangers optimized for district cooling applications are available on request. Fans Double suction centrifugal fans made with ABS or aluminium, with statically and dynamically balanced forward-curving blades, directly coupled to the electric motor. Air filter Washable air filter, made of acrylic fibre, filtration class G or G, applied on the air intake; may be pulled out from below. Hydronic indoor units - DUCTIMAX ACCESSORIES ELECTROMECHANICAL CONTROL PANELS CD Recess wall-mounted speed selector CDE Wall-mounted speed selector TD Wall-mounted speed selector, thermostat and summer/winter selecting switch TDC Wall-mounted speed selector and thermostat TD4T Wall-mounted speed selector, thermostat and summer/winter selecting switch for or 4-pipe systems with valves TC Thermostat for minimum water temperature in heating mode, mounted on the heat exchanger TA Ambient thermostat TA Ambient thermostat with summer/winter selecting switch KP Power interface for connecting in parallel up to 4 fan coils to one controller MICROPROCESSOR ELECTRONIC CONTROL PANELS MCBE MyComfort base electronic controller with display MCME MyComfort medium electronic controller with display MCLE MyComfort large electronic controller with display DIST MyComfort controller spacer for wall mounting EVODISP Evo Clock Remote display EVOVOARD EVO 0V circuit board LED50 Recess wall-mounted electronic controller with display CO (B-G-W) Plate for LED50, white W (RAL 70), grey G (RAL 900), black B (RAL 9005) MCSWE Water sensor for EVO, MYCOMFORT BASE, MEDIUM, LARGE, and LED 50 microprocessor controllers MCSUE Humidity sensor for EVO, MYCOMFORT MEDIUM and LARGE microprocessor controller PLENUM AND AIR INLET AND OUTLET CONNECTORS PMA PMAC PAF RD Uninsulated air outlet/intake plenum with Ø 00 mm collars Insulated air outlet/intake plenum with Ø 00 mm collars Uninsulated front air intake plenum with Ø 00 mm collars Straight uninsulated air inlet/outlet connector RDC R90 R90C MAFO Straight insulated air inlet/outlet connector 90 uninsulated air inlet/outlet connector 90 insulated air inlet/outlet connector Air intake module with G4 undulated filter CONNECTION HOSES AND PLUGS TFA TFM TP Uninsulated hose Ø 00 mm Insulated hose Ø 00 mm Plastic plug Ø 00 mm AIR OUTLET AND INTAKE DUCTS CA CAF CM Air intake duct with honeycomb grille Air intake duct with honeycomb grille and G filter Insulated air outlet duct, with -way grille AIR OUTLET AND INTAKE GRILLES GM GA Aluminium air outlet grille with -row fins, with frame Aluminium air intake grille, with frame MOTOR DRIVEN ON/OFF AND MODULATING VALVES VK ON-OFF -way motor driven valve (0V and 4V actuator), with hydraulic kit for standard and DF heat exchanger VK Modulating -way motor driven valve (4V actuator), with hydraulic kit for standard and DF heat exchanger KV ON-OFF -way motor driven valve (0V and 4V actuator), with hydraulic kit for standard and DF heat exchanger KVM Modulating -way motor driven valve (4V actuator), with hydraulic kit for standard and DF heat exchanger ACCESSORIES VRC Auxiliary external drip tray. RE Additional heating element for installation on board the unit, complete with safety devices KSC Condensate drainage pump VM6600087-0 galletti.com 87

Duct unit DUCTIMAX Rated technical data DM DS 0 40 0 40 Fan speed min med max min med max min med max min med max 4 6 4 6 5 7 5 7 Air flow E m /h 8 46 76 8 46 76 7 75 4 7 75 4 Available static pressure Pa 5 50 6 5 50 6 9 50 77 9 50 77 Power supply V-ph-Hz 0--50 Power input (E) W 4 57 8 4 57 8 4 06 4 06 Total cooling capacity () kw,,78,98,8,97,8,0,97,8,9,8,64 Sensible cooling capacity () kw 0,77,8,4 0,80,6,5 0,9,4,70 0,96,5,84 Water flow l/h 9 06 8 0 8 74 8 40 8 74 4 Water pressure drop () kpa 5 6 7 8 6 8 4 8 Heating capacity () kw,,8,9,7,8,64,60,8,8,69,64, Water flow l/h 94 4 5 0 49 89 8 5 48 48 89 47 Water pressure drop () kpa 4 5 6 7 5 6 7 0 row DF heating capacity () kw,56,4,8,56,4,8,79,9,69,79,9,69 row DF Water flow l/h 7 98 09 7 98 09 58 09 8 58 09 8 row DF Water pressure drop () kpa 4 4 row DF heating capacity () kw,6,50,78,6,50,78,6,8 4,5,6,8 4,5 row DF Water flow l/h 9 06 9 06 7 5 9 7 5 9 DF row DF Water pressure drop () kpa 7 8 7 8 4 8 4 8 Standard coil - number of rows n 4 4 Total sound power level db(a) 6 48 5 6 48 5 6 50 58 6 50 58 Inlet + radiated sound power level db(a) 4 46 50 4 46 50 4 48 56 4 48 56 Outlet sound power level db(a) 49 49 47 55 47 55 DM DS 0 40 40 440 Fan speed min med max min med max min med max min med max 6 7 6 7 4 7 4 7 Air flow E m /h 94 60 40 94 60 40 05 5 65 05 5 65 Available static pressure Pa 4 50 6 4 50 6 7 50 76 7 50 76 Power supply V-ph-Hz 0--50 Power input (E) W 4 47 06 4 47 06 76 4 9 76 4 9 Total cooling capacity () kw,47,6,6,60,77,07,00,,87,7,9 4,64 Sensible cooling capacity () kw,05,77,97,0,9,4,50,5,00,65,75,7 Water flow l/h 5 407 0 74 475 56 4 569 66 407 67 796 Water pressure drop () kpa 5 5 7 9 8 6 4 8 Heating capacity () kw,88,59,5,9,69,7,78 4,40 5,,8 4,47 5, Water flow l/h 8 479 56 8 497 547 4 569 66 407 67 796 Water pressure drop () kpa 5 6 6 7 7 9 4 9 row DF heating capacity () kw,8,5,75,8,5,75,8 4,6 4,8,8 4,6 4,8 row DF Water flow l/h 09 0 8 09 0 8 8 8 4 8 8 4 row DF Water pressure drop () kpa 4 4 4 4 6 7 6 7 row DF heating capacity () kw,0 5, 5,70,0 5, 5,70 4,6 7,0 8,0 4,6 7,0 8,0 row DF Water flow l/h 74 7 500 74 7 500 400 66 706 400 66 706 DF row DF Water pressure drop () kpa 6 7 6 7 5 0 5 0 Standard coil - number of rows n 4 4 Total sound power level db(a) 6 5 58 6 5 58 9 5 60 9 5 60 Inlet + radiated sound power level db(a) 4 50 56 4 50 56 7 50 58 7 50 58 Outlet sound power level db(a) 49 55 49 55 5 47 56 5 47 56 88 galletti.com VM6600087-0

DUCTIMAX - 8 kw Rated technical data DM DS 50 540 60 640 Fan speed min med max min med max min med max min med max 6 7 6 7 Air flow E m /h 7 687 760 7 687 760 4 70 8 047 70 8 Available static pressure Pa 50 6 50 6 40 50 60 40 50 60 Power supply V-ph-Hz 0--50 Power input (E) W 76 67 9 76 67 9 5 80 5 80 Total cooling capacity () kw, 4,9 4,8,54 4,95 5,4 6,6 6,97 7,5 7, 7,80 8,4 Sensible cooling capacity () kw,70,6,58,79,50,8 4,7 5,9 5,6 5,04 5,54 5,99 Water flow l/h 96 75 88 46 850 99 09 97 9 40 4 Water pressure drop () kpa 7 8 0 6 8 0 6 Heating capacity () kw,05 5,66 6,6,8 6,04 6,59 7,94 8,65 9,8 8,59 9,40 0, Water flow l/h 96 75 88 46 850 99 09 97 9 40 4 Water pressure drop () kpa 6 7 8 0 5 6 9 row DF heating capacity () kw,86 5,86 6,8,86 5,86 6,8 7,5 7,64 7,96 7,5 7,64 7,96 row DF Water flow l/h 8 55 544 8 55 544 66 670 699 66 670 699 row DF Water pressure drop () kpa 8 6 8 8 6 8 5 7 5 7 row DF heating capacity () kw 5,05 8,68 9,5 5,05 8,68 9,5,4,0,5,4,0,5 row DF Water flow l/h 44 760 84 44 760 84 999 056 098 999 056 098 DF row DF Water pressure drop () kpa 6 6 8 6 6 8 6 8 0 6 8 0 Standard coil - number of rows n 4 4 Total sound power level db(a) 9 55 60 9 55 60 59 6 69 59 6 69 Inlet + radiated sound power level db(a) 7 5 58 7 5 58 57 60 67 57 60 67 Outlet sound power level db(a) 5 5 56 5 5 56 55 58 65 55 58 65 Hydronic indoor units - DUCTIMAX () Water temperature 7- C, air temperature D.B. 7 C, W.B. 9 C (47% relative humidity) () Inlet water temperature 50 C, water flow rate same as in cooling mode, air temperature 0 C () Water temperature 70 / 60 C, air temperature 0 C (4) Sound power measured according to standards ISO 74 and ISO 74 (E) EUROVENT certified data VM6600087-0 galletti.com 89

Duct unit DUCTIMAX Dimensional drawings DUCTIMAX - 4 4.5 C 5 D 5 4.5 0 89.5 0 89.5 C A 5 D 5 7 E 7 60 575 A 7 E 7 07 07 95 6 4 5 499 4 4 6 05 86 9 79 50 6 5 5.5 05 86 9 79 60 575 95 6 5 499 4 6 50 6 5 40 5.5 00 DUCTIMAX 0-40 0-40 0-40 40-440 A 757 757 967 967 C 677 677 887 887 D 648 648 858 858 E 70 70 9 9 / / / / / / / / Ø 7 Ø 7 Ø 7 Ø 7 LEGEND Standard heat exchanger water connections Additional heat exchanger water connections Condensate drainage 90 galletti.com VM6600087-0

DUCTIMAX - 8 kw Dimensional drawings DUCTIMAX 5-6 4.5 9.5 0 4.5 9.5 0 7 7 096 5 066 5 77 7 7 685 096 5 066 5 77 7 7 685 6 8 6 8 0 06 4 68 597 50 86.5 09 09 06 4 68 597 50 86.5 60 60 09 09 60 60 Hydronic indoor units - DUCTIMAX 0 9 8 9 5.5 5.5 8 40 40 00 00 DUCTIMAX 50-540 60-640 /4 /4 /4 /4 Ø 7 Ø 7 LEGEND Standard heat exchanger water connections Additional heat exchanger water connections Condensate drainage VM6600087-0 galletti.com 9