Moulded case circuit brakers

Similar documents
1.Application. 2.Main Technical Specifications B-10

Welcome to Hager Presentation

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

Drawing Submittal Package

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Drawing Submittal Package

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Circuit Breaker with Residual Current Protection (CBR)

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

Guide Specification Model CTG Automatic Transfer Switch

DGC-1000 DIGITAL GENSET CONTROLLER

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

VAMP 120 & 121. Arc flash detection units. Product picture

QA(13) - Series Miniature Circuit Breakers

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

DGC-500 DIGITAL GENSET CONTROLLER

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Sentry G3 Machinery Protection Monitor

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

OPERATING INSTRUCTIONS COP-F (ANSI 81O/81U)

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Variable Frequency Drive SERIES MP800 VFD

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Sentry G3 Machinery Protection Monitor

Annunciator Unit SACO 16 D1. Product Guide

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Carbon Monoxide Transmitter

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

M15051) INSTRUCTION MANUAL

Dr. Anton Poeltl, ABB PPHV, 5/19/2014 Condition Monitoring Approach Sensors, Methods, Data. ABB Month DD, YYYY Slide 1

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

ZXSe Range Data Sheet

Datasheet - MZM 100 ST-SD2PREM-A

DANFOSS OPTYMA PLUS INVERTER UNITS

Family of motor protection

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Datasheet - MZM 100 B ST2-SD2PREM-A

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

RSGD. Three phase AC motor soft starter. Benefits. Description

Annunciator unit. Application

Molded Case Circuit Breakers, Bulletin 140G

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

NGC-40 Advanced Heat-Tracing Control System

Datasheet - MZM 100 ST2-1P2PWREM-A

Frequently asked questions: Intelligent Transmitter Series

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Residual Current Devices

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Moulded Case Circuit breakers

Overload relays. General descriptions. Configuration of the front

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

CMD420 / CMD421 Series

I/O ZONE 560/583 USERS GUIDE

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

7SG17-Rho 3 Multifunction Protection Relays Answers for energy

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Tachometer/Hourmeter/Trip. Installation and Operation Manual

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ECO N DATE DESCRIPTION OF CHANGE CHG

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

DC POWER DISTRIBUTION BOARD

Product data sheet AIRWIN additional modules Accessories AIRWIN

Analog Annunciator Unit SACO 16 A3. Product Guide

Operation and use. Functions and characteristics

AIS750 Series Alarm Annunciator

STEAMPAK Series BurnerPAK BMS Burner Management Systems

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Ordering Key. Dielectric strength

Table of Contents. Protective Relays

Gas Controller Module GC-06

Transcription:

Moulded case circuit brakers

CONTENT Range 1 Protection Releases 2 Salient Features 5 Accessories 7 Widest Range 10 Time Current Characteristics 12 Overall Dimensions 14 SN4 SN3 SN2 SN1 3

RANGE SN1 Rated Current 20, 25, 32, 40, 50, 63, 80, 100 A Release Thermal-Magnetic SN2 Rated Current 63, 80, 100, 125, 160, 200, 250 A 40, 63, 100, 160, 250 Release Thermal-Magnetic Microprocessor SN3 Rated Current 320, 400, 500, 630 A 63, 160, 250, 400, 630 A Release Thermal-Magnetic Microprocessor SN4 Rated Current 800, 1000, 1250, 1600 A Release Microprocessor 4

PROTECTION RELEASES Thermal-Magnetic Release Features of Thermal-Magnetic Release Adjustable protection overload settings Adjustable protection short circuit settings True RMS sensing No contact with live parts Protection Overload Short circuit* Earth fault Settings 80% - 100% Ir 3-6 In External * Setting from 6-10 In available on request Microprocessor Release Features of RC10 Microprocessor Release Overload protection with Short circuit protection with selectable time delay Instantaneous over ride protection Earth fault protection with selectable time delay Port for release testing Push to trip button Power ON LED Self powered / Protection mode can be ON / OFF True RMS sensing In (A) RC10 Overload (Phase) From 63 to 1600 A Current setting, Ir (Ir = XIn) 0.4 to 1.0 in steps of 0.1 Time delay, tr (Inverse) Protection mode Current setting, In (Intrl = XIr) Current setting, Is (Is =Xlr) Time delay, ts Protection mode Overload (Neutral) Short Circuit 10 sec at 6 Ir On / Off 0.5 to 1.0 in steps of 0.25 Inverse 10 sec at 6 Intrl / Fixed 200ms On / Off 1.5, 4, 6 & 8 Ir 10 / 100 msec. On / Off Instantaneous Over ride Current setting, Ip 12 In upto 400 A 8 In for 630 to 1600 A Earth Fault Current setting, Ig 0.2 to 0.5 In steps of 0.1 Time delay, tg 100 / 200 msec Protection mode On / Off 5

PROTECTION RELEASE Microprocessor Release Features of RC20 - Communication Capable Power on LED Backlit LCD display Scroll buttons Push to trip button All features of RC10 release are incorporated Metering for current parameters Protection against unbalanced load / single phasing I²t protection Neutral protection Cold load protection User friendly navigation system Selfpowered MODBUS RTU protocol 6 RC20 Rated Current In A From 63 to 1600 A Overload (Phase) Current setting (A), Ir (Ir = xin) 0.4 to 1.0 in steps of 0.1 Current setting (A), Ir (Ir = xin) 3, 6, 10, 15, 30 at 6 Ir Protection mode On / Off Preset trip alarm setting 0.8 to 1.0 Ir in steps of 0.05 Thermal memory On / Off Overload (Neutral) Current setting (A), Ir 50%, 75%, 100% In Time delay tn(s) at 6 Ir As per overload Protection mode On / Off Preset trip alarm setting Intrl 0.8 to 1.0 Ir in steps of 0.05 Short Circuit Current setting (A), Is 1.5 to 8Ir in steps of 0.1Ir Time delay ts(ms) For - I²t OFF 20 to 200 in steps of 20 For - I²t ON 60 to 200 in steps of 20 Protection mode On / Off Preset trip alarm setting 0.8 to 1.0 times Is in steps of 0.05 Is Cold load pickup Enable / Disable Instantaneous Over ride Current setting (A), Ip 12In for 400 A 8In for 630 to 1600 A Earth Fault Current setting (A), Ig 0.2 to 0.5In steps of 0.1In Time delay(ms), tg 0.1, 0.2, 0.5, 1, 3sec. Preset trip alarm setting 0.8 to 1.0 Ig in steps of 0.05 Protection mode On / Off Cold load pickup Enable / Disable

Protection Release Additional Features of RC20 Current unbalance Current setting (A)x In 10% to 100%In in steps of 5% Time delay (s) 1 to 10 in steps of 0.5 Protection mode On / Off Cold load pickup Enable / Disable Temperature rise Alarm / Trip At 80 ºC / At 100 ºC Metering Current Phase, Neutral and Earth Display Backlit LCD Communication* Protocol MODBUS RTU Link used RS 485 Event records Pickup, Trip, Alarm current during last 5 trip Trip history upto 128 records Trip counter record Counts for total number of trips ComManager Software ComManeger is a solution to control & flow in your electrical systems. Salient Features Supports 32 devices User friendly Windows based software with GUI Robust networking Piracy protection through hardware lock Event recording Real time monitoring Historical trend of various parameters Snapshot of all parameters for all devices in the network Communication healthy signal on the frontend Complete data integrity * To establish communication with computer every MCCB with RC20 will require a communication module. 7

State - of - the - art technology Faster Tripping: The unique speed contact system accelerates the opening of contacts during short circuit. This ensures faster tripping an ultimate current limiting feature. The result-very low let-through, cut-off current and fault clearing time. This unique feature ensures that under short circuit conditions, the contacts open and latch even before the release gives a trip command to the mechanism. This avoids contact re-closing and bounce. Mechanical Anti-reclosing: The entire current carrying path is optimally designed to achieve very low watt loss. Low watt loss: Positive Isolation: The MCCB knob indicates the true position of the contacts. Double Insulation: The internal accessories are housed in insulated casings to ensure first level of insulation. When the front cover is opened for the fixing of internal accessories, the MCCB is totally insulated ensuring the double insulation. Marking: Marking ensures use of superior engineering plastic, meeting all requirements of flammability and glow wire test. 8

State - of - the - art technology Common Internal accessories: The internal accessories remain same across DN2 / DN3 / DN4 range* and they are easy to install click fit type. No side bias: Internal accessories can be mounted on the either side. LINE LOAD Terminal finger proofing: Front terminal plates conceal the terminals to prevent human contact thus achieving complete finger proofing. Terminal shrouding: Terminal shrouds cover spreader terminals preventing human contact with terminals. Release shrouding: Release is shrouded from the front thus preventing tampering by unauthorized person. Safer release adjustments: No live parts are in contact during release adjustments. No load line bias: Either side of MCCB terminal can be used as load or line. Common front adjustments for Protection release: Overload & short circuit setting can be adjusted from front using a common knob for all the poles. Visibility: Push to trip button and release ratings are visible even when release plate is fitted. * Except under voltage 9

Accessories Internal Accessories Range of MCCBs are offered with click-fit type, easily installable internal accessories. There is no need to open main cover and no live parts are accessed during installation. Any accessory can be fitted on any side enhancing flexibility. Auxiliary Contact List of Internal Accessories Auxiliary Contact 1 C/O Auxiliary Contact 2 C/O Trip Alarm Contact Auxiliary & Trip Alarm Contact Shunt Release Under Voltage Release MCCB with mid cover opene & Internal accessories fitted. External Accessories Rotary Operating Mechanism The rotary operating mechanism (ROM) for MCCBs are available in Direct & Extended versions. Direct rotary handle ( MCCB mounted ) These versions are available for the entire family of MCCBs. These ROMs can be supplied with key lock for SN2 and SN3 frames. Extended rotary handle ( Panel mounted ) 10 ROM mounts directly on MCCB without removal of midcover Door interlock in OFF condition with padlock feature Clear ON/OFF/TRIP indication Clear view of MCCB rating label with ROM mounted Direct access to push to trip button with ROM mounted IP 54 degree of protection with extended rotary handle Unique coupling to allow +/- 3mm tolerance Keylock version available Door interlock in ON position, with defeat facility Auto restoration of door interlock Extended rotary handle: Panel mounted

Accessories Electrical Operating Mechanism MCCB with Electrical Operating Mechanism Features Clear ON / OFF / TRIP indication Cover and Carriage Interlock - EOM will not operate if EOM cover is open EOM is not properly fixed on MCCB This ensures safe and reliable operation of EOM Manual operation possible Padlock facility for locking in OFF position Easy access to the release even with EOM mounted Applications Facilitates remote operation of MCCBs Facilitates use in process automation applications and auto change over schemes Technical Specifications Operating Voltage SN2 - MM (SN2-250), SN3 - MM (SN3-630) Operating Voltage 24, 48 VDC, 240 VAC Operating Time SN2 < 2.2 sec, SN3 < 3.3 sec Mechanical Interlock kit Features For 3 Pole & 4 Pole versions Suitable for SN2 & SN3 frames MIL with base plate 11

TYPE SN1-100 SN2-160/250 No. of Poles Rated Current Rated Operational Voltage Rated Insulation Voltage Rated Impulse withstand Voltage Rated Frequency Reference Ambient Temperature Utilisation Category Versions Rated Ultimate S.C. Breaking Capacity [at 415 V AC, 50 Hz] I n U e U i U imp I cu A V V kv Hz 0 C ka 3 16, 20, 25, 32, 40, 50, 63, 80, 100 415 690 6 50 / 60 40 A Standard 30 Standard SN2-160S, 250S 3/4 63, 80, 100, 125, 160, 200, 250 415 750 8 50/60 40 A High SN2-160H, 250H Extra High SN2-160L, 250L 35 50 70 Rated Service S.C. Breaking Capacity [at 415 V AC, 50 Hz] I cs ka 50% of I cu 100% of I cu DC Breaking Capacity [at 250 V, L/R + 15 msec] ka 15 25 35 12 Type of Release Current Rating Protection Terminal Capacity Dimensions Weight (Unpacked) Reference Standards A C C E S S O R I E S Internal External Overload Instantaneous Standard With Spreader Links Box Clamp 3 / 4 Poles Note: Any two internal accessories can be mounted at a time I n [cables] [link] [cables] [link] [Cu. Cable] W H D A 2 mm 2 mm 2 mm 2 mm 2 mm mm mm mm Kg Auxiliary Contact Trip Alarm Contact Auxiliary & Trip Alarm Contact Shunt Release Under Voltage Release Rotary Operating Mechanism Electrical Operating Mechanism Earth Fault Release Mechanical Interlock Plug-in / Draw-out unit Terminal Shrouds Spreader Links Box Clamp Key lock / Pad lock Thermal-Magnetic 16, 20, 25, 32, 40, 50, 63, 80, 100 Adjustable 0.8-1I n. 9I n 35 16 35 75 130 60 0.725 IEC 60947-2 / EN 60947-2 / IS 13947-2 1C/O or 2C/O 1C/O or 2C/O 1C/O + 1C/O 240-415 V ac 50 / 60 Hz 240 V ac 50 Hz X X X Thermal-Magnetic 63, 80, 100, 125, 160, 200, 250 0.8-1I n. 3-6I n / 6-10I n Adjustable 95 25 x 5 185 35 x 6 120 105 / 140 179 96 2.5 / 3.3 IEC 60947-2 / EN 60947-2 / IS 13947-2 1C/O or 2C/O 1C/O 1C/O + 1C/O 110-415 V ac 50 / 60 Hz,110-220 V dc 220-240 V ac 50 / 60 Hz Plug-in unit

SN3-400/630 SN4-800/1000 SN4-1250/1600 Standard SN3-400S, 630S 3/4 320, 400, 500, 630 High SN3-400H, 630H 3/4 800 415 415 750 750 8 8 50 / 60 50 / 60 40 40 A A Extra High Standard SN3- SN4-400L, 630L 800S, 1000S High SN4-800H, 1000H Standard SN4-1250S, 1600S 3/4 1250 415 750 8 50 / 60 40 A High SN4-1250H, 1600S 35 50 70 50 70 50 70 100% of I cu 100% of I cu 100% of I cu 15 25 35 25 35 25 35 Thermal-Magnetic Microprocessor Microprocessor Microprocessor 320, 400, 500, 630 63, 160, 250, 400, 630 800, 1000 1250, 1600 0.8-1I n. 3-6I n / 6-10 I n Adjustable For details go to page No. 2 For details go to page No. 2 For details go to page No. 2 120 185 185 27 x 15 2 x 185 2 x 40 x 15 2x 300 2 x 40 x 15 2 x 300 2 x 40 x8 240 2 x 60 x 15 2 x 60 x 15 140 / 183.5 280 280 266 111.5 370 139 370 139 5.5 / 7.2 6.0 / 7.8 15 / 16 15 / 16 IEC 60947-2 / EN 60947-2 / IS 13947-2 IEC 60947-2 / EN 60947-2 / IS 13947-2 IEC 60947-2 / EN 60947-2 / IS 13947-2 1C/O or 2C/O 1C/O or 2C/O 1C/O or 2C/O 1C/O 1C/O 1C/O 1C/O + 1C/O 110-415 V ac 50 / 60 Hz, 110-220 V dc 1C/O + 1C/O 110-415 V ac 50 / 60 Hz, 110-220 V dc 1C/O + 1C/O 110-415 V ac 50 / 60 Hz,110-220 V dc 220-240 V ac 50 / 60 Hz 220-240 V ac 50 / 60 Hz 220-240 V ac 50 / 60 Hz Inbuilt protection with Microprocessor release Draw - out unit Inbuilt protection with Microprocessor release X Draw - out unit Inbuilt protection with Microprocessor release X Draw - out unit X X X X X 13

new SN1 Finger proof shrouding : safe to use. Arc suction effect arc chutes - High Breaking Capacity Overload adjustment from top Front Push to Trip buttons Side by Side mounting possible Knob designed for better grip Current rating on the knob Colour indication of ON/TRIP/OFF Lockable shroud on the knob to prevent unauthorised access Double insulation for internal accessories Accessories Auxiliary Contacts Shunt Release Trip Alarm Contacts U/V Release Auxiliary Contacts Aux. + Trip alarm contact Rotary Operating Mechanism Box Clamp Spreader Links Pad Lock Rotary Operating Mechanism 14

Time - Current Characteristic Curves SN1-100 SN2-160/250 Thermal-Magnetic Release 6 8 SN3-400/630 15

Time - Current Characteristic Curves Microprocessor Release RC10 RC20 16

Overall Dimensions SN1-100 12.5 25 25 CABLE TERMINAL SCREW: M6 20 28.5 62.5 61.5 58 112 39 46 38 45 130 112 116 25.5 25 75 25 MCCB MOUNTING SCREW : M3-2Nos. 60 85 SUITABLE FOR 35 x 7.5 TOP HAT RAIL MOUNTING 61 30 2.5 46.5 76 Mounting & Door Cutout Details SN1 with Spreader Links 92 35 35 60 86.1 20 2 194.2 172.2 11 30.2 130 20 22 17

Overall Dimensions SN2-160/250 MCCB 142 16 A 111.5 121 104.2 82.7 ON TRIP OFF 234 266 77 224 78 43.5 43.5 26.5 183.5 140 B 43.5 43.5 SN2-160/250 3P with Spreader Links SN2-160/250 4P with Spreader Links 154 43 A 6 142 209.5 43 A 6 142 61 61 25 406 356 25 ON TRIP OFF 266 406 356 ON TRIP OFF 266 55.5 55.5 B 6 55.5 55.5 55.5 B 6 18

Overall Dimensions SN3-400/630 MCCB 119 96 35 35 27.5 ON TRIP 163 8 179 45 72.7 17.5 17.5 61 46 157 OFF 35 35 35 17.5 140 105 25.5 42 42 86 Mounting & Door Cut-out Details Terminal width = 25.5.mm SN3-400/630 3P with Spreader Links Type A B SN3-400 39 37 SN3-630 41 38 SN3-400/630 4P with Spreader Links 125 170 38 18 45 45 35 27.5 4 18 38 45 45 45 35 27.5 4 239 ON TRIP OFF 275 239 ON TRIP OFF 275 25.5 4 25.5 4 19

Overall Dimensions SN4-800/1000/1250/1600 MCCB 280 195.7 171 46 132.5 ON TRIP 370 105 326 106 OFF T 44 24 25 TYP TYP 46 139 68 68 SN4-800/1000/1250/1600 with Spreader Links 195 80 80 80 143 15 46 20 85 510 370 105 132.5 85 60 24 15 45 20

Rom Door CUT-out details Direct ROM door cut-out detail L5 17 L4 N L3 L2 L1 Type L1 L2 L3 L4 L5 SN1 96.5 58 52 44 37 SN2 122 96 63 53 66 SN3 156 121 87 78 82 Extended ROM door cut-out detail REFER PANEL CUT DETAILS L2 I 50 45 L3 I 76 N I 4 L1 L Type L1 L2 L3 L4 SN1 160 L1-119 7.5 69.5 SN2 202 L1-152 27 84 SN3 233 L1-183 39 122 SN4 302 L1-252 69 170 21

Overall Dimensions Overall Dimensions with EOM A B ON C TRIP OFF Type Dimensions in mm A B C For SN2 EOM 205 18 112.3 For SN3 EOM 226 46.5 147.3 22

NOTES 23

Iskra MIS, d. d. Ljubljanska c. 24a SI- 4000 Kranj, Slovenia Phone: +386 (0) 4 23 72 112 Fax: +386 (0) 4 23 72 109 www.iskra-mis.si