Balance of Plant Maintenance

Similar documents
Predictive Maintenance Training

ANSI/NETA Standards Update

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

DISTRIBUTION OPERATIONS AND MAINTENANCE

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

Property risk solutions

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

Electrical Safety Compliance: NFPA 70E

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

Maintenance Best Practices & Intervals for Substation Equipment. Presented by: Paul Schlies, President/CEO Energis High Voltage Services, Inc.

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

EFCOG BEST PRACTICE # 203. Best Practice Title: Risk Assessment / Operation of Overcurrent Protection Devices

NFEC FIRE SAFETY SEMINAR Krish Mysore

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

The safe way to verify the absence of voltage.

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

NFPA 70E Edition Update

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

How to reduce exposure to arc flash hazards

PROTECTING AGAINST ARC FLASH HAZARDS

SEL Arc-Flash Solutions

Becoming a NETA Accredited Company

SEL Arc-Flash Solutions

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

PGR-8800 TECHNICAL FAQ

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

Part 1 General Part 2 Indenter modulus Part 4 Oxidation Induction methods Accepted by IEC and IEEE for publication Published in September 2011

Engineering Design & Testing Corp./EDT Engineers, P.C.

NEMA Applications Guide

NFPA 70E Elevates Safety. with Heightened Risk Awareness

NECA. Standard for Electrical Safety in the Workplace

Electrical Hazards and NFPA-70E: Protecting Your Employees

SolarPower Europe O&M Task Force

The evolution of level switches and detectors

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

ELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE 2017

Distribution Control Center Operator Training

SECTION SECURITY TESTING AND COMMISSIONING

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

6/23/ National Electrical Contractors Association and Intec, Inc.

Subject: Fire Protection Impairment Program Reference: NFPA (see bottom of page 5) Effective Date: August 2014 Distribution All YC Employees

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

Arc Flash Protection Training - NFPA 70e Electrical Safety

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

Monitoring of Electrical Equipment Failure Indicators and Alarming

Safety Meeting Topic #37 NFPA 70E What is it?

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

What Utility Analytics means to Exelon

Electrical Energy department

Portable Equipment. Equipment with electrical components suitable to be moved by a single person without mechanical aids.

NECA S System Approach to Electrical Safety for NFPA 70E

NFPA 70E Electrical Safety & Arc Flash Training

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

ELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE Setting the Standard Energizing the Future

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

UNDERSTANDING 2015 CHANGES TO NFPA 70E

CHAPTER 20 SERVICE EQUIPMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Pro Board Assessment Methodology Matrices for NFPA 1001

Guide to Transmission Equipment Maintenance

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

COMMERCIAL INDUSTRIAL OIL & GAS POWER GENERATION MOTOR CONTROL PLC PROGRAMMING EMERGENCY RESPONSE

UNDERSTANDING 2015 CHANGES TO NFPA 70E

26 of 128 9/23/2014 9:25 AM

Fire System Impairment Policy

PART 8 - Miscellaneous Services 3rd Revised Sheet 1 SECTION 8 - Other Miscellaneous Services Replacing 2nd Revised Sheet 1

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

Electrical Preventive Maintenance (EPM) Program

SECTION ISOLATED POWER SYSTEMS

Electrical Safety Requirements

Relay Performance Index for a Sustainable Relay Replacement Program

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Rapid Intervention Team

Hard rock mining solutions

Installation, Operation & Service Manual

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Transcription:

Balance of Plant Maintenance Planning AWEA Project Performance & Reliability Workshop Mike Moore Discuss Some Statistics Key Learning Objectives Discuss Maintenance Planning Generator Breakers Power Cables Oil Filled Transformers Collector Substation Standards Challenges for the Wind Industry 1

Historical Electric Losses by Asset Type Source: Factory Mutual Global (1991 2000) Equipment Number Gross $ Millions Transformers 1,000 492 Cable/Wiring/Bus 893 362 Switchgear/Circuit Breakers 602 254 Generators 174 166 Motors 580 145 Misc. Electrical Apparatus 261 49 TOTAL 3,510 1,467 Reliability Lingo The ability of a system to perform and maintain its functions in routine circumstances, as well as hostile or unexpected circumstances. Acceptance for Service Testing performed on a system, lots of manufactured mechanical/electrical parts, or products prior to its placement into service to verify it is safe for placement into service and will operate per its intended design. 2

Lingo Preventive Maintenance Care and servicing by personnel for the purpose of maintaining equipment and facilities in satisfactory operating condition by providing for systematic inspection, detection, and correction of incipient failures either before they occur or before they develop into major defects. Lingo Predictive Maintenance (PdM) techniques help determine the condition of in-service equipment in order to predict when maintenance should be performed. This approach offers cost savings over routine or time-based Preventive Maintenance, because tasks are performed only when warranted. 3

Generator Breaker Periodic Maintenance (Weekly/Monthly/Annually) Connections -Grounding& Conductors Mechanical Operation Infrared Inspections Ultrasound Inspections Generator Breaker Periodic Maintenance (Every Two Years) Connections -Grounding& Conductors Mechanical Operation Electrical Testing Over-Current Protective Devices Insulation Resistance Contact Resistance Control Device Operation 4

Generator Step-Up Transformer Periodic Maintenance (Monthly/Quarterly/Annually) Connections - Grounding & Conductors Mechanical Operation of Oil Immersed Switches Infrared Inspection Oil/Headspace Leaks Headspace/Nitrogen Blanket Electrical l Testing Control Devices Insulating Oil Sampling & Analysis Oil Quality DGA Generator Step-Up Transformer Periodic Maintenance (Every Three Years) Connections - Grounding & Conductors Oil/Headspace Leaks Electrical Insulation Testing Power Factor/Dissipation Power Factor Turns Ratio (TTR) Winding Resistance Insulation Resistance Insulating Oil Sampling & Analysis Oil Quality DGA Furanic Compounds 5

Collector Power Cables Periodic Maintenance (Annually) Connections -Grounding& Conductors Bends/Radius Exposed Terminations Visual Inspection Infrared Inspection On-Line Partial Discharge Sampling Ultrasound Inspection Collector Power Cables Periodic Maintenance (Every Three Years) Connections -Grounding& Conductors Bends/Radius Terminations Electrical Testing *Very Low Frequency (VLF) Tan Delta Power Factor/Dissipation Power Factor Off-Line Partial Discharge 6

Collector Substation Periodic Maintenance (Weekly/Monthly/Quarterly) Connections - Grounding & Conductors Event Recorders Collector Terminations Station Batteries Station Service Transformers Oil Levels Winding Temperatures Oil Temperatures Headspace/Nitrogen Blanket Arresters/Bushings MV/HV Breaker Operations Outdoor Bus/Structures Collector Substation Periodic Maintenance (Annually) All Previous Inspections (Weekly/Monthly/Quarterly) Electrical Test Infrared Inspection On-Line Partial Discharge Sampling Ultrasound Inspection Battery Testing/Load-bank Protective Relay Testing / Electrical Operation of Devices NERC/FERC Compliance Testing & Maintenance Insulating Oil Sampling & Analysis (Transformer & Tap changer) Oil Quality DGA 7

Collector Substation Periodic Maintenance (Every Three Years) All Previous Inspections (Weekly/Monthly/Quarterly) Electrical Test All Previous Inspections (Annuals) Medium /High Voltage SF6 Circuit Breaker Testing & Maintenance Main Substation Transformer Testing & Maintenance NERC/FERC Compliance Testing & Maintenance Insulating Oil Sampling & Analysis (Transformer & Tap changer) Oil Quality DGA *Furanic Compounds (Transformer Only) Standards & Program Development Develop maintenance programs off of national consensus standards to bring credibility and reliability to the program. IEEE 902-1998 (Yellow Book) Guide for Maintenance, Operation and Safety of Industrial and Commercial Power Systems NFPA 70B Recommended Practice for Electrical Equipment Maintenance ANSI/NETA MTS-2007 International Electrical Testing Association s Maintenance Testing Specifications Approved American National Standard (ANSI) Annex B -Offers guidelines for the frequency of maintenance tests 8

Standards & Program Development Develop maintenance programs off of national consensus standards to bring safety to the program. NFPA 70E Standard for Electrical safety in the Workplace Chapter 2 Safety Related Maintenance Practices Write a safety-or reliability-based electrical acceptance testing plan for all new equipment to ensure that installation meets applicable codes, standards and safely operates as designed by the manufacturer Develop an electrical maintenance plan for existing and service-aged electrical equipment that evaluates and trends insulation systems, mechanical operation and over-current protective devices for proper operation Standards & Program Development Develop maintenance programs off of national consensus standards to bring safety to the program. (cont.) NFPA 70E Standard for Electrical safety in the Workplace Chapter 2 Safety Related Maintenance Practices Institute practices like First Trip to give site managers a real world look at equipment operating speeds Validate all over-current protective devices with the most recent coordination study settings 9

Challenges for Wind Energy Wind energy equipment and systems presents unique hazards for electrical work: Extreme heat/cold Mechanical hazards Multiple power sources Worker fatigue Personnel challenges Elevated Working High incident energy at many locations in the collector Questions? Mike Moore Phone: 888-SHERMCO www.shermco.com 10