Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Similar documents
XP95 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE

XP95 Product Guide MAN 3037

SERIES 65 ENGINEERING PRODUCT GUIDE

Series 65 Product Guide MAN 3036

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

XP95 Sounder VAD Base

Analogue addressable devices

ENGINEERING PRODUCT GUIDE

The supplier and installer of the system should be approved by the local civil defence authority.

optical detector multisensor detector heat detector mounting bases product guide

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Product Guide MAN7030-2

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM

Evolution Analogue Addressable Fire System

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Apollo Accreditation. Need further information? Visit

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

HART XL High Sensitivity Smoke Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Elite-A Analog Addressable Fire Control Panels (2 or 4 Loops) (Apollo Protocol)

Fire & Security Products. Siemens Building Technologies Group

XP95/Series 90 Test Set

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

Conventional Smoke Detectors KFAPO

ALK-V PHOTOELECTRIC SMOKE SENSOR

The new detector from Rafiki

ECO N DATE DESCRIPTION OF CHANGE CHG

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Intellia Sounder Bases and Sounder Beacon Bases

Interface Modules for SENTRI

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

SOUNDER CONTROL MODULE SCM-AS4

Technical data sheet TDS0060

TrueAlarm Analog Sensing

HART XL High Sensitivity Smoke Detection

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

SAFETY INTEGRITY LEVEL MANUAL. IEC and IEC XP95 and Discovery SIL Approved Product Range

ZXSe Range Data Sheet

Consultant Specification AGILE Wireless Fire Detection System

Emergi-Lite Orbis detectors

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

IFD-E Flame Detector User Manual

HUM-M2 Humidity Sensor Module Description

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Flame Detector User Manual

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Danfoss gas detection units

S TEM PRODUCT SPECIFICATION

Solution F2. Fire Alarm Control Panels one step ahead.

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Reflective Optical Beam Smoke Detector User Guide

IFD-E Flame Detector User Manual

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Interface and EOL Modules 8

TrueAlarm Analog Sensing

Orbis IS Product Guide MAN 3041

P2267 NETWORK INTERFACE

Movement Detector GJD 300

4 wire conventional alarm system

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Touch Screen 1 loop Addressable Fire Alarm Panel

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

General Routing Interface

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Complete packages with Software and Controller

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Danfoss gas detection units

Apollo Test Set - User Manual 1. Apollo Test Set. User Manual

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

ALARMLINE ANALOGUE Linear Heat Detection System

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

intelligent solutions

Vega Devices.

Reflective Beam Smoke Detector

2000 Series Sensors Installation Guide

02/11/2015

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

NIDS Dust sensor ED-N-DS-1408

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

HOA0880-T51. Representative photograph, actual product appearance may vary.

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Actionpac 60/120 (LNS Standard)

LF /2. Fire Alarm Control Panel. Features:

RS Pro Infrared Temperature Sensor

Transcription:

TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who want to access the benefits of analogue systems without having to commit to complex design and commissioning. The XPlorer range comprises an optical smoke detector, two heat detectors and a manual call point. Two mounting bases are available for the detectors: a standard base and a remote LED driver base which is used if it is desired to connect a remote indicator LED. Detectors are supplied with either the standard or the LED driver base. An isolator is available to prevent the loss of entire loops in the event of a short circuit. An Output Unit is provided to switch external equipment. Apollo Fire Detectors Limited, part of the Halma plc group of companies, operates from one site at Havant, near Portsmouth, England. All departments Research and Development, Sales & Marketing, Operations and Finance are located there. Apollo applies the most modern production techniques and has invested in sophisticated manufacturing equipment to ensure consistent high quality of product and fast response to customer requirements. Key features Complete product range Proven digital protocol Simple system design Simple ordering Full LPCB approval Information in this guide is given in good faith, but Apollo Fire Detectors Limited cannot be held responsible for any omissions or errors. The company reserves the right to change specifications of products at any time without prior notice.

TABLE OF CONTENTS Features of the XPlorer Range 2 Application of XPlorer Detectors 2 Addressing and Communications 2 Optical Smoke Detector Operating principles 3 Electrical description 3 Environmental characteristics 4 Technical data 4 Heat Detector Operating principles 5 Electrical description 5 Environmental characteristics 5 Technical data 6 Manual Call Point Operating principles 7 Technical data 7 Output Unit Operating principles 8 Electrical considerations 8 Protocol bit usage 8 Mechanical construction 8 Technical data 8 page 1 Isolator Operating principles 9 Electrical description 9 Technical data 9 XPlorer Mounting Bases and XPERT cards 9 Maintenance of detectors 9 Approvals 9

page 2 Features of the XPlorer Range Entry level system: 63 detector addresses and 63 interface addresses. Robust Protocol: Digital protocol for error-free transmission Control Unit Interrogation and Command: 3 bits of command instruction and the 7- bit address are issued by the control equipment following an initiating pulse. Interrupt Warning: Notification that an XPlorer manual call point has been operated. Analogue Value Report: Smoke or heat level continually reported. Input Bits Reporting: XPlorer smoke and heat detectors confirm compliance with the output command bits. Automatic Type Identification: The device being interrogated reports what type of device it is. Address Confirmation: The 6-bit address of the detector or interface responding is confirmed back to the control unit. XPERT Card Addressing: For fast reliable installation and service. Unobtrusive Design: For elegant designs in modern buildings. Application of XPlorer Detectors The choice of detector from the XPlorer range follows the well established principles of system design. That is, the optimum detector type will depend on the type of fire risk and fire load, and the type of environment in which the detector is sited. For general use, smoke detectors are recommended since these give the highest level of protection. Where the environment is smoky or dirty under normal conditions, a heat detector may be more appropriate. It must be recognised, however, that any heat detector will respond only when the fire is well established and generating a high heat output. Addressing and Communications Each XPlorer device responds to interrogation and command from central control equipment. It communicates information on status, command bits, type and location to the control panel. A unique, patented XPERT card provides simple, user friendly and accurate identification of detector location whereby a coded card, inserted in the base, is read by any detector once it is plugged in. All the electronic components are in the detector but the location information is held in the base. The address card simplifies and speeds up installation and commissioning. Addressing errors during maintenance and service are eliminated. XPlorer detectors read the lower six bits of the address card, giving a range of 1 63 The XPlorer manual call point, the Output Unit and the Switch Monitor use DIL switch addressing. A range of compatible control equipment is available from many sources details are available from Apollo.

OPTICAL SMOKE DETECTOR Fig.1a XPlorer standard base wiring Fig.1b XPlorer LED driver base wiring XPlorer Optical Smoke Detector Part Number 59000-605 (with standard base) Part Number 59000-606 (with LED driver base) Operating Principles The XPlorer optical detector has a moulded selfextinguishing white polycarbonate case designed to allow free entry of smoke while minimising the effects of dust contamination. Stainless steel wiper contacts connect the monitor to the terminals in the mounting base. Within the case is a printed circuit board which on one side has the light proof labyrinth chamber with integral gauze surrounding the optical measuring system. The other side has the address capture, signal processing and communications electronics. An infrared light emitting diode (IR LED) within the optical chamber is arranged at an obtuse angle to a photodiode. The photo-diode has an integral daylight-blocking filter. The IR LED emits a burst of collimated light every photo-diode receives no light directly from the IR LED. When smoke enters the chamber it scatters light from the IR LED onto the photodiode in an amount related to the smoke characteristics and density. The photodiode signal is processed by the optical ASIC and passed to the A/D converter on the communications ASIC ready for transmission when the device is interrogated. Electrical Description The detector is designed to be connected to a two wire loop circuit carrying both data and a 17V to 28V DC supply. The detector is connected to the incoming and outgoing supply via terminals in the mounting base. Connection is polarity sensitive. (Figs 1a & 1b). the supply terminals a connection for a remote LED is provided. The remote LED is connected between the positive supply line of the base and the remote negative terminal. The negative connection incorporates a 4k3 limiting resistor to protect the loop from accidental short circuit remote wiring. The LED current should be limited to 4mA. When the device is energised the ASICs regulate the flow of power and control the data processing. The optical ASIC is controlled by the communications ASIC and pulses the IR LED. The signal from the photo-diode is processed by the optical ASIC and transferred to the A/D converter in the communications ASIC where it is then stored. When smoke enters the chamber the photo-diode signal increases. The information to the A/D converter is updated once per second. Whenever the device is interrogated this data is sent to the control equipment. The detector is calibrated to give an analogue value of 25±7 counts in clean air. This value increases with smoke density. A count of 55 corresponds to the calibrated alarm threshold. A remote LED driver base is second. In clear air the also available. In addition to Fig.2 Top section - XPlorer Optical Smoke Detector page 3

page 4 TECHNICAL DATA XP95 Optical Specifications are typical and given at 23 C and 50% relative humidity unless otherwise specified. Address Range: 1 63 (6 bits) Detector Type: Products of combustion (smoke) Detection Principle: Photo-electric detection of light scattered in a forward direction by smoke particles Chamber Configuration: Horizontal optical bench housing an infrared emitter and sensor arranged radially to detect forward scattered light Sensor: Silicon PIN photo-diode Emitter: GaAlAs Infra-red light emitting diode Sampling Frequency: 1 second Supply Wiring: Two wire supply, polarity sensitive Detector Terminal Functions: Supply positive and negative in and out connections (polarity sensitive). Remote indicator connection to LED driver base Supply Voltage: 17 to 28 Volts dc Quiescent Current: 340µA Duration of Power-up Surge Current: 1 second Maximum Power-up Time: (measured from application of power and protocol) 4 seconds for communications 10 seconds to exceed 10 counts 35 seconds for stable clean air value Storage Temperature: -30 C to +80 C Operating Temperature: (No condensation or icing) -20 C to +60 C Clean Air Analogue Value: 25±7 counts Alarm Level: 55 counts Alarm Indicator: Red light emitting diode (LED) Alarm LED Current: 2mA Remote LED Base Connection: 4.3kΩ connected to negative line Type Code: (210 43) 101 00 Sensitivity: Nominal threshold of 2.4% light grey smoke obscuration per metre Humidity: (No condensation) 0% to 95% relative humidity Wind Speed: Unaffected by wind Atmospheric Pressure: Insensitive to atmospheric pressure Electro-magnetic Compatibility: marked. A copy of the relevant declaration is available on request. IP Rating: 43 Dimensions: (diameter x height) Detector: 100mm x 39mm Detector in Base: 100mm x 47 mm Weights: Detector: 100g Detector in Base: 157g Materials: Detector Housing: White polycarbonate V-0 rated to UL 94 Terminals: Stainless Steel Vibration, Impact & Shock: technical To EN54 7:2000 data Environmental Characteristics The XPlorer optical smoke detector is unaffected by wind or atmospheric pressure and operates over the temperature range -20ºC to +60ºC.

HEAT DETECTOR Fig.4a Standard Heat Detector Fig.4b High Temperature Heat Detector XPlorer Heat Detector Part Number 59000-405 (with standard base) Part Number 55000-406 (with LED driver base) Operating Principles The XPlorer heat detectors have a low air flow resistance case made of self-extinguishing white polycarbonate. The devices monitor temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The response to heat increases of the standard heat detectors, Part Nos 59000-405 and 59000-406, enables the detector to be Fig.3 XPlorer Heat Detector utilised as an EN54 5:2000 A2S heat detector, which is equivalent to an EN54 5:1984 Grade 2 detector. (Fig 4a). A high temperature heat detector, Part No 59000-415 (with standard base) or 59000-416 (with LED driver base), which has similar characteristics at 25ºC but reaches a 55 count at 90ºC, is available for use in normal ambient temperatures of up to 55 C. This detector meets the requirements for a CS detector in EN54 5:2000. (Fig 4b). Electrical Description The detector is designed to be connected to a two wire loop circuit carrying both data and a 17V to 28V DC supply. The detector is connected to the incoming and outgoing supply via terminals in the mounting base. Connection is polarity sensitive. (Fig 2a) A remote LED driver base is also available. In addition to the supply terminals a connection for a remote LED is provided. The remote LED is connected between the positive supply line of the base and the remote negative terminal. The negative connection incorporates a 4.3kΩ limiting resistor to protect the loop from accidental short circuit remote wiring. The LED current should be limited to 4mA. When a device is energised the ASIC regulates the flow of power and controls the data processing. The thermistor provides an output over normal operating ranges that, in the case of the standard detector, is proportional to the external air temperature. This voltage output is processed in the A/D converter and stored by the communications ASIC. It is transmitted to control equipment when the device is interrogated. The detector is calibrated to give an analogue value of 25±5 counts at 25ºC. The high temperature heat detector operates in a very similar manner, but the 55 count alarm threshold indicates a temperature of 90 C. Environmental Characteristics XPlorer standard heat detectors operate over the range -20ºC to +70ºC. The high temperature heat detectors operate over the range -20ºC to +120ºC. The detectors are unaffected by atmospheric pressure. page 5

page 6 TECHNICAL DATA XPlorer Standard Heat Detector Specifications are typical and given at 23 C and 50% relative humidity unless otherwise stated. Address Range: 1 63 (6 bits) Detector Type: Fixed Temperature Heat Detection Principle: Temperature sensitive resistance Sensor: Single NTC Thermistor Sampling Frequency: Continuous Sampling Frequency: Continuous Supply Wiring: Two wire supply, polarity sensitive Detector Terminal Functions: Supply positive and negative in and out connections (polarity sensitive); remote indicator connection to LED driver base Supply Voltage: 17 to 28 Volts DC Quiescent Current: 300µA at 24V Power-up Surge Current: 1mA Duration of Power-up Surge Current: 1 second Maximum Power-up Time: 4 seconds Storage Temperature: -30 C to +80 C Min Continuous Operating Temperature: -0 C Min Operating Temperature (no condensation or icing): -20 C Application Temperature: Class EN54 5:2000 A2S typical 25ºC, max 50ºC Static Response Temperature ºC: Min Typ Max 54 58 62 Alarm Level Analogue Value: 55 Alarm Indicator: Red light emitting diode (LED) Alarm LED Current: 2mA Remote LED base connection: 4.3kΩ connected to negative line Type Code: (210 43) 110 00 Sensitivity: 25ºC to 90ºC: 1ºC/Count -20ºC returns 8 counts Humidity: (No condensation or icing) 0% to 95% relative humidity Wind Speed: Unaffected Atmospheric Pressure: Unaffected Vibration, Impact & Shock: To EN54-5:2000 Electro-magnetic Compatibility: marked. A copy of the relevant declaration is available on request. IP Rating: 53 Dimensions: (diameter x height) Detector: 100mm x 39mm Detector in Base: 100mm x 47mm Weights: Detector: 100g Detector in Base: 157g Materials: Detector Housing: White polycarbonate V-0 rated to UL 94 Terminals: Stainless Steel TECHNICAL DATA XPlorer High Temperature Heat Detector Specifications are the same as those for the standard temperature, apart from the following points: Detector Principle: Temperature sensitive resistance. Linear approximation designed to give 26 counts at 25ºC and 55 counts at 90ºC Type Code: (210 43) 110 01 Application Temperature: Class EN54 5:2000 CS typical 55ºC, max 80ºC Static Response Temperature C: Min Typ Max 84 90 96 Sensitivity: 25ºC to 90ºC: 2 17ºC/Count -20ºC returns 20 counts technical data

MANUAL CALL POINT TECHNICAL DATA Maximum Power-up Time: 4 seconds XPlorer Manual Call Point Alarm LED Current: 1mA Specifications are typical and apply at temperature 23ºC and relative humidity 50% unless otherwise stated. Normal Analogue Value: 16 Alarm Level Analogue Value: 64 XPlorer Manual Call Point (MCP) Part Number 59000-910 Operating Principles The XPlorer manual call point is designed for surface mounting and incorporates the call point assembly and a back box. The address of each call point is set at the commissioning stage by means of a six-segment DIL switch, giving a range of addresses from 64 to 126. A single alarm LED is provided on the call point. This LED is controlled, independently of the call point, by the CIE. Call points can be remotely tested from the control and indicating equipment by transmission of a single bit in the communications protocol. Call points respond by providing a value of 64 which corresponds to the alarm value. The CIE will recognise this response as a test signal and will not raise a general alarm. Address Range: 64 to 126 Call Point Type: Break Glass Weight: 190g Call Point Principle: Operation of a switch Alarm Indicator: Red Light Emitting Diode (LED) Type Code: (2 1 0 4 3) 1 1 1 1 1 Supply Wiring: Two-wire supply, polarity sensitive Loop connections: Flying leads with spade terminals Operating Voltage: 17-28V DC Quiescent Current: 270µA Power-up Surge Current: 650µA Electro-magnetic Compatibility: marked. A copy of the relevant declaration is available on request Temperature Range: Max. continuous operating: +60ºC Min. continuous operating: 0ºC Min. operating: -20ºC (no condensation/icing) Storage: -30ºC to +80ºC Humidity: 0 to 95% relative humidity (no condensation) Vibration, Impact and Shock: To pren54 11 IP Rating: 53 Dimensions: 87mm x 87mm x 52mm Materials: Housing: Red polycarbonate/abs page 7

OUTPUT UNIT XPlorer Output Unit Part Number 59000-810 TECHNICAL DATA Output Unit Address Range: 64 to 126 Operating Voltage: 17 28V DC Maximum current consumption at 24V: switch-on surge, max 100ms 3mA quiescent 720uA relay operated 2mA Relay output contact rating at 30V AC or DC, max: 1A (inductive or resistive) Relay output wetting at 10mV DC: 10µA Operating temperature: 20 C to +70 C Humidity(no condensation): 0 95% Shock Vibration GEI 1-052 Impact } Electro-magnetic Compatibility: marked. A copy of the relevant declaration is available on request. Dimensions and weight of Output Unit: 65mm x 45mm x 22mm 31g page 8 Operating Principles The XPlorer Output Unit provides a voltage-free, single pole, change-over relay output. The change-over contact is operated by an output bit. The Output Unit returns an analogue value of 16 under all conditions. Electrical Considerations The Output Unit is loop powered. The loop connections are polarity sensitive Protocol Bit Usage The control equipment transmits a 10-bit message to the Output Unit: The output (or forward command) bits from the control panel have the following function. Output bits 2 and 1 are not used. Output bit 0 controls the relay. When output bit 0 is set to logic 1 on two or more consecutive pollings, the relay changes state to the set condition. Bit 0 must be set to logic 1 as long as it is desired to keep the relay in its set state. The relay will remain latched in the set state until output bit 0 is set to logic 0 on two or more consecutive polls. Discontinuation of interrogation of its address will not affect the state set or not of the relay but removal of loop power will reset the relay. The seven bits which are then transmitted by the control panel correspond to the address (as set on the lower 6 bits of the DIL switch with an internal preset high bit) of the device to be polled. The 6 bits of the DIL switch give an addressable range of 64 to 126. A response message is then sent by the Output Unit to the control equipment: The interrupt bit is always set to logic 0 The analogue value bits are sent to return a preset value of 16 under all conditions. The input bits are not used by the Output Unit. The type bits are used to identify the type of unit responding. The type code of the Output Unit is 01000 (bits 2,1,0,4,3 respectively). The Output Unit sends seven bits of data to confirm its address. The alarm flag is not placed by the Output Unit. Mechanical Construction The Output Unit is normally supplied with screws for surface mounting. It is designed for indoor use only.

ISOLATOR XPlorer Isolator Part Number 59000-700 Operating Principles The XPlorer isolator senses and isolates short circuit faults on XPlorer loops. It is loop powered and polarity sensitive. Power and signals to the affected section are restored automatically when the fault is cleared. Electrical Description Under normal operating conditions, a low resistance is present between the L IN and L OUT terminals of the isolator, so that power and signals pass to the next device in the line. If a short circuit or abnormally low resistance occurs, the fall in voltage is sensed and the isolator isolates the negative supply in the direction of the fault. The XPlorer incorporates the same isolating circuitry as other Apollo isolating devices. For more information on isolation principles please refer to PIN sheet PP2090, Short circuit isolation in XP95 and Discovery fire detection systems. TECHNICAL DATA XPlorer Isolator Minimum Loop Operating Voltage in normal conditions: 17V DC Maximum Loop Operating Voltage: 28V DC Maximum Loop Current: 1A continuous 3A switching Maximum Load: 20 XPlorer detectors or equivalent Operating Temperature: 20 C to +60 C Storage Temperature: 30 C to +80 C Operating Humidity: 0 95% RH, non-condensing XPlorer Mounting Bases and XPERT Cards The XPlorer detectors all fit the XPlorer mounting base and LED driver base. Cable connections of up to 2.5mm diameter are made via captive cable clamps. There are three terminals on the standard mounting base and an additional two on the remote LED driver base. Universal address cards, known as XPERT cards are supplied with all bases. Consult the coding guide supplied with the bases to determine which pips are to be removed. The base has a one way only fit and detectors can be locked into the base by a locking screw with the aid of a small cross-point screwdriver. Maintenance of Detectors Apollo Fire Detectors has published a guide to the care, maintenance and servicing of Apollo products, PP2055, which is available on request. This guide outlines the maintenance routines recommended for optimum detector performance and the services available from Apollo s factory-based Service Department. Approvals XPlorer smoke and heat detectors comply with EN54 7:2000 and EN54 5:2000 respectively. Detectors also comply with EMC Directive 89/336/EEC and are CE marked. Each detector type is designed to be approved by approval and regulatory bodies worldwide, including LPCB in the UK. Detectors and manual call point are LPCB approved. page 9

PP2098/2001/Issue 1 Quality Systems Certificate No 010 Assessed to ISO 9001 36 Brookside Road, Havant, Hampshire PO9 1JR, UK. Tel: +44 (0)23 9249 2412. Fax: +44 (0)23 9249 2754. Email: TechSales@apollo-fire.co.uk Website: www.apollo-fire.co.uk