Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS

Similar documents
S AGE E NGINEERING A SSOCIATES, LLP

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required.

Appendix B. Facilities Assessment Report

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Florence High School / Middle School Page 1 of 3 Florence, WI

PLAN REVIEW SUBMITTAL GUIDE

GARCIA GALUSKA DESOUSA Consulting Engineers

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

Massachusetts School Building Authority

SIGNIFICANT CHANGES TO MINOR WORK AND ORDINARY MAINTENANCE

PLATTEVILLE MIDDLE SCHOOL

DEERFIELD SCHOOL DISTRICT REFERENDUM Committed to Excellence and Equity in Educating Our Students

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE DEPARTMENT LEDYARD, CT

GARCIA GALUSKA DESOUSA Consulting Engineers

ARCHITECTURAL ASSESSMENT

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

GARCIA GALUSKA DESOUSA Consulting Engineers

Mechanical System Description

NYC Department of Education

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

Facility Improvements

Ashland School District Facility & Capacity Assessment Report 2005

NYC Department of Education

NYC Department of Education

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

NYC Department of Education

NYC Department of Education

NYC Department of Education

Rental Housing Inspection Guide

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING

DMTF: Specific Building Recommendations

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

NYC Department of Education

NYC Department of Education

NYC Department of Education

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

NYC Department of Education

Agustin Lara Elementary Academy

NYC Department of Education

NYC Department of Education

Siemens Building Technology MEP Existing Conditions

Axiom Property Inspections

NYC Department of Education

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

NYC Department of Education

CHAPTER 7 ALTERATIONS LEVEL

Vanilla Box Design Criteria

4. Plumbing fixtures. a) The plumbing fixtures are from the original building. They are appear old and not to comply with ADA requirements.

NYC Department of Education

NYC Department of Education

NYC Department of Education

NORTH CAROLINA. Downloaded (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided:

NYC Department of Education

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

NYC Department of Education

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

Josefa Ortiz De Dominguez Elementary School

NYC Department of Education

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

Electrical Inspection Special Electrical

NYC Department of Education

Electrical Information

NYC Department of Education

NYC Department of Education

Inside Out Home Inspections

Appendix E: Photo Documentation

NYC Department of Education

NYC Department of Education

Edward Jenner Elementary Academy of the Arts

SITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL)

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

Calmeca Academy of Fine Arts and Dual Language

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan

NYC Department of Education

12 W. MIACOMET RD. NANTUCKET ISLAND

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

NYC Department of Education

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

NYC Department of Education

Plan Review Check List Fire Alarm System

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

DRAFT. Widen Elementary School Site Summary 74,523 SF. Introduction

NYC Department of Education

NYC Department of Education

NYC Department of Education

RE: Clark East Tower Renovations DATE: November 16, 2015 Ypsilanti, Michigan

Transcription:

EXISTING MECHANICAL CONDITIONS SUMMARY The items listed below are based on our site visit on Nov 10, 2016. Our review is based on current conditions and anticipated future use of these building. In the context of current mechanical code references, we used 2009 International Energy Code (IECC). NFPA31, 90A, 90B and 96 are also referenced where applicable. Minimum required ventilation requirements are from the 2009 International Mechanical Code. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS Mechanical / HVAC: Heating system is hydronic (hot water) baseboard with finned tube radiation around the perimeter. Boiler is standard efficiency propane fired boiler located on the second floor. There are three zones two on the first floor one on the second, zoning is by pumps. There is no mechanical ventilation in the building. The bathroom does have an exhaust fan that appears to be operational. Plumbing: Plumbing fixtures appear to be ADA compliant. There are no drinking fountains in the building. There is a 40 Gallon propane fired water heater in the second floor mechanical space to heat domestic water. Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS Replace boiler with propane condensing high efficiency unit. New boiler can be located in the same location as the existing boiler. Replace exhaust fan in all bathroom as a minimum. Install heat recovery ventilation for entire building. ELECTRICAL SYSTEMS Power Distribution: The electrical service that serves the building is overhead from a pole mounted transformer voltage is 120/240V single phase. The main panel is a Federal Pacific 100A main breaker panel located in the front exterior wall. Utility meter is located at side of the building. Much of the wiring and electrical distribution equipment (panel) in the building has exceeded its service life and is in poor condition. All electrical wiring in the original portion of the building should be replaced. Receptacles: The quantity of outlets is insufficient for a modern office space, additional receptacles need to be added around the room to facilitate power needs for technology. Town Office Building November 21, 2016 1

General Lighting: The lighting is a combination of T12 fluorescent. The majority of the lighting could be upgraded to more energy efficient LED type. These types of fixtures will save on relamping costs and energy usage costs. Exit and Egress Lighting: There are very few emergency lights in the building. There are fluorescent exit signs at the main exits but more are needed to comply with current codes. Emergency battery lighting needs to be added to the facility to meet NFPA 101 Life Safety Code on the interior and exterior. Existing exit signs should be replaced and supplemented to meet NFPA 101 Life Safety Code. Fire Alarm System: The fire alarm devices in this building are connected back to a central panel located in the Annex Building. There are horn/strobes located throughout the facility but does not comply with current NFPA and ADA codes. Additional devices need to be added to bring the system up to current NFPA and ADA codes. ELECTRICAL SYSTEMS RECOMMENDATIONS Replace all original wiring and receptacles with new. Replace panel Install new LED lighting. Install code required emergency and exit signs. PHOTO DOCUMENTATION Exterior back wall pack light. Town Office Building November 21, 2016 2

Electrical meter Window AC unit Boiler with zone pumps Town Office Building November 21, 2016 3

Propane fired Water heater Exhaust ductwork from bathroom exhaust fan Telephone backboard Town Office Building November 21, 2016 4

EXISTING MECHANICAL CONDITIONS SUMMARY The items listed below are based on our site visit on Nov 10, 2016. Our review is based on current conditions and anticipated future use of these building. In the context of current mechanical code references, we used 2009 International Energy Code (IECC). NFPA31, 90A, 90B and 96 are also referenced where applicable. Minimum required ventilation requirements are from the 2009 International Mechanical Code. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS Mechanical / HVAC: Heating system is hydronic (hot water) baseboard with finned tube radiation around the perimeter. Boiler is standard efficiency propane fired boiler. There is no mechanical ventilation in the building. The bathroom does have an exhaust fan that appears to be operational. Plumbing: Plumbing fixtures are generally old, in poor condition and non-ada compliant. The building has a well and the pneumatic tank located in the boiler room. There are no drinking fountains in the building. There is a 40 Gallon electric water heater in the mechanical room in the back of the building for heat domestic water. Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS Replace boiler with propane condensing high efficiency unit. New boiler can be located in the same location as the existing boiler. Replace exhaust fan in all bathroom as a minimum. Install heat recovery ventilation for entire building. Replace all plumbing fixtures with ADA compliant fixtures. ELECTRICAL SYSTEMS Power Distribution: The electrical service that serves the building is overhead from a pole mounted transformer 120/240V single phase 100A main breaker panel located in the storage room. Utility meter is located at side of the building. Much of the wiring and electrical distribution equipment (panel) in the building has exceeded its service life and is in poor condition. All electrical wiring in the building should be replaced. Annex November 21, 2016 1

Receptacles: The quantity of outlets is insufficient for a modern office space, additional receptacles need to be added around the room to facilitate power needs for technology. General Lighting: The lighting is a combination of T12 fluorescent. The majority of the lighting could be upgraded to more energy efficient LED type. These types of fixtures will save on relamping costs and energy usage costs. Exit and Egress Lighting: There are very few emergency lights in the building. There are fluorescent exit signs at the main exits but more are needed to comply with current codes. Emergency battery lighting needs to be added to the facility to meet NFPA 101 Life Safety Code on the interior and exterior. Existing exit signs should be replaced and supplemented to meet NFPA 101 Life Safety Code. Fire Alarm System: There is a fire alarm system in the building the fire alarm panel is located in the storage room. Fire alarm system consists of Silent knight 5207 panel that serves the site (including Annex, Town Hall and Library) and there is an exterior annunciator used for fire department response on this building. There are horn/strobes located throughout the facility but does not comply with current NFPA and ADA codes. Additional devices need to be added to bring the system up to current NFPA and ADA codes. ELECTRICAL SYSTEMS RECOMMENDATIONS Replace all original wiring and receptacles with new. Replace panel Install new LED lighting. Install code required emergency and exit signs. PHOTO DOCUMENTATION Propane Tank For all buildings Annex November 21, 2016 2

Overhead service Overhead Service Meter Annex November 21, 2016 3

Existing Federal Pacific panel Burnham Boiler Pneumatic Pressure Well tank Annex November 21, 2016 4

Domestic Water heater Fire alarm annunciator South side looking back towards Library Annex November 21, 2016 5

EXISTING MECHANICAL CONDITIONS SUMMARY The items listed below are based on our site visit on Nov 10, 2016. Our review is based on current conditions and anticipated future use of these building. In the context of current mechanical code references, we used 2009 International Energy Code (IECC). NFPA31, 90A, 90B and 96 are also referenced where applicable. Minimum required ventilation requirements are from the 2009 International Mechanical Code. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS Mechanical / HVAC: Heating system is propane fired furnaces ducted into the areas. One standard efficiency furnace serves the majority of the building that has an associated AC unit ducted into the basement that is changed over in summer. There is a newly installed high efficiency unit located in the most recent addition in the basement children s area. Neither system provides mechanical ventilation in the building. The bathroom does have an exhaust fan that appears to be operational. Plumbing: Plumbing fixtures are ADA compliant with the exception of the flush handle on the toilet is located on the wrong side of the tank. There is a 6 Gallon electric water heater in the basement to heat domestic water. Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS Replace one furnace with propane condensing high efficiency unit. New unit can be located in the same location as the existing furnace. Replace exhaust fan in all bathroom as a minimum. Install heat recovery ventilation for entire building. Replace all plumbing fixtures with ADA compliant fixtures. ELECTRICAL SYSTEMS Power Distribution: The electrical service that serves the building is overhead from a pole mounted transformer 120/240V single phase 200A main breaker panel located in the basement. Utility meter is located at side of the building. Receptacles: The quantity of outlets is insufficient for a modern office space, additional receptacles need to be added around the room to facilitate power needs for technology. General Lighting: The lighting is a combination of T12 fluorescent. The majority of the lighting could be upgraded to more energy efficient LED type. These types of fixtures will save on relamping costs and energy usage costs. Library November 21, 2016 1

Exit and Egress Lighting: There are emergency lights in the building. There are exit signs at the main exits but more are needed to comply with current codes. Emergency battery lighting needs to be added to the facility to meet NFPA 101 Life Safety Code on the interior and exterior. Existing exit signs should be replaced and supplemented to meet NFPA 101 Life Safety Code. Fire Alarm System: The fire alarm devices in this building are connected back to a central panel located in the Annex Building. There are horn/strobes located throughout the facility but does not comply with current NFPA and ADA codes. Additional devices need to be added to bring the system up to current NFPA and ADA codes. ELECTRICAL SYSTEMS RECOMMENDATIONS Install new LED lighting. Install code required emergency and exit signs. PHOTO DOCUMENTATION Exterior electrical meter Library November 21, 2016 2

Exterior ducted AC unit Flexible Ducts into basement Radon Fan Library November 21, 2016 3

Exterior Bulkhead Standard Efficiency Furnace original portion of the building Basement ductwork Library November 21, 2016 4

Winter /summer changeover operational sheet Electrical panel Sewer exit in basement Library November 21, 2016 5

Domestic water heater in basement Security and Fire alarm wiring in basement Radon Piping in Basement Library November 21, 2016 6

Lighting original portion Kitchenette Standard ungrounded outlet Library November 21, 2016 7

Exit and emergency lighting ADA Toilet flush handle on wrong side of tank ADA compliant sink Library November 21, 2016 8

Security panel Typical horn strobe Library November 21, 2016 9

Subpanel in basement of addition Newly installed High Efficiency furnace children s area. Library November 21, 2016 10

EXISTING MECHANICAL CONDITIONS SUMMARY MECHANICAL / PLUMBING / SPRINKLER SYSTEMS Mechanical / HVAC: Empire Propane Fired wall heater located on the first floor Plumbing: None Sprinkler: None ELECTRICAL SYSTEMS Power Distribution: 100A, 120/240 New panel General Lighting: Mostly incandescent lighting, track head for displays. Fire Alarm System: None RECOMMENDATIONS None PHOTO DOCUMENTATION UPPER FLOOR LIGHTING Historical Society Building November 21, 2016 1

Upper Floor exit lighting Electrical panel Propane fired Heater Historical Society Building November 21, 2016 2

EXISTING MECHANICAL CONDITIONS SUMMARY MECHANICAL / PLUMBING / SPRINKLER SYSTEMS Mechanical / HVAC: None Plumbing: None Sprinkler: None ELECTRICAL SYSTEMS Power Distribution: Appears to be all newly rewired circuit from Town Hall wiring is new MC cable. General Lighting: New Motion activated T8 fluorescent. Fire Alarm System: None RECOMMENDATIONS None PHOTO DOCUMENTATION TYPICAL RADIATOR: Knox Box Hobo Barn November 21, 2016 1

Front Exterior flood light Motion detector activated lights Hobo Barn November 21, 2016 2