OPERATING MANUAL. for the modular heat presses. Secabo TC5 SMART and TC7 SMART

Similar documents
OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7 PREMIUM

Nautilus 4050 Heat Press. User Manual

MANUAL. for heat press. Secabo TC2

MANUAL. for heat presses. Secabo TC5 and TC7

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD12

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

MANUAL. for membrane base plates. 45cm x 45cm and 47cm x 57cm

CONNECTED HEAT PRESSES TC SMART SERIES

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

HOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

Installation and user manual

HOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

DC200 Digital Dispenser Operating Manual

EHA Hoffmann International GmbH

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Digital Knight 16x20 Automatic Digital Swinger

Dryer Controller M720

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Model PT-05 Model PT-06

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

for Ultima-Tig and for Ultima-Tig-Cut

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Refrigerated air dryers

Instruction manual. Version heat press. BluePRESSLine CAP. Version / 13

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

User Manual. Dryer Controller M720

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

POLYMIX PX-IG 2000 Operating Instructions

Goldpress 4+ OPERATING, MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4+ MACHINE

Crimping machine RC AS Operating instructions

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instruction manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Wireless Rain Gauge with Indoor Temperature

QUICK USER GUIDE. Alarm Control Panel

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

IDEAL E-NERGY Thermostat Touch type User Manual

INSTRUCTION MANUAL P Heating and 1 Cooling

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

Model: Available in: Sapphire Black and Glacier White. 1 Series

Control solutions Biofloor

Smart thermostat with Humidification/De-humidification control

USERS MANUAL FOR GAS BOILERS

Programmable Interactive User Manual

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Alarm System SECURE AS 302

Smart Thermostat. User Guide

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Model: Available in : Sapphire Black and Glacier White. 1 Series

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

status AW1 Plus WiFi Alarm System User Manual

TDS 20 R / TDS 30 R / TDS 50 R

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

User instructions DHP-AT

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

EN Glass Jug Blender

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

RAE Systems. Using the MeshGuard. Protection Through Detection

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Installation and Operating Manual

OPERATING INSTRUCTIONS

MULTI-CHANNEL IN-OUT CABLE FREE THERMO-HYGROMETER

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

Visit for more technical information and downloads.

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Portable Air Conditioner

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Weather Forecast RF Wall Clock with Romote Thermometer Model: JMR818WF. User Manual

Wiser Air User Interface Guide. Thermostat

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

VK902 Compact Combination Microwave Oven Installation, Use and Maintenance

SCHMIDT LED Measured Value Display MD Instructions for Use

Important safety instructions

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Electronic Pellet Burner Controller NPBC-V3M

ADT Pulse Mobile App Nest Thermostat

Joto Automatic Mug Press Manual Model No.: E-HP-JMP-AUTO

Lyric T6 & T6R Smart Thermostat

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

GE JB400 Steam Clean Range. Range Models: JB400DP1WW JB400DP1BB JB400SPSS

Transcription:

OPERATING MANUAL for the modular heat presses Secabo TC5 SMART and TC7 SMART Congratulations on the purchase of your Secabo heat press! Please read this operating manual carefully to ensure a smooth production launch with your new device. Any type of reproduction of this operating manual requires the written permission of Secabo GmbH. Modifications to and errors in the technical data and/or product characteristics are reserved. Secabo GmbH accepts no liability for any direct or indirect damages resulting from the use of this product. Version 1.0 (05/01/2017) 1

Safety Precautions Please read the information and safety precautions carefully prior to first commissioning of the device! Never reach inside the heat press with your hands when it is connected to the power supply, especially if it is switched on and heated up danger of burns! Never open the casing and do not make any modifications to the unit yourself. Should it be necessary to open the heat plate cover upon explicit request by Secabo's customer service team, it is recommended you wear respiratory protection and only touch the insulation wool located therein using gloves. Possible disposal of the insulation wool should only be done inside a closed bag. Ensure that neither liquids nor metal objects reach the inside of the heat press. Make sure you use a grounded wall socket. Keep in mind that a heat press may only be operated using a wall socket equipped with a ground fault circuit interrupter. Disconnect the heat press from the power supply when it's not in use. Always ensure that the heat press is out of reach of children during operation and never leave the device unsupervised when switched on. Make sure the unit is only used in dry rooms. If you cannot comply with one or more of the aforementioned safety rules, or if you are unsure as to whether you're in compliance with all of the points, please contact our technical support. 2

Items included Mechanical base of the heat press heat press base Heat plate and base plate HP5-38cm x 38cm or HP7-40cm x 50cm depending on the model Controller box HPC01 C13 Cold device cable Size 5 Allen key for M6 inner hexagonal screws Spanner 13 for M8 hexagon screws 3

Machine description a. Main switch b. Liquid Crystal Display (LCD) c. Control panel with buttons and rotary push setter d. Hand wheel for pressure adjustment e. Press lever f. Heat plate cover and heat plate g. Base plate h. Button for manually opening the press i. IEC socket and internal connections (not depicted) 4

Installation and Commissioning Safely set up the base frame heat press base of the TC5 SMART or TC7 SMART heat press on a sturdy table. Open the press lever at the heat press base in such a manner that it points steeply upwards. Position the heat plate HP5 or HP7 - depending on the model - in front of the connecting flange below the press lever on the heat press base at a slant and thread the 4 outer screws heads into the keyhole grooves on the flange plate. Carefully tighten the screws using the included Allen key. Attention: As long as the screws are not properly tightened, the heat plate may fall down! Risk of injury! Lift the supplied base plate over the heat press base's socket and thread the screw heads of the hexagon screws through the keyhole grooves on the black adapter plate at the bottom side of the heat plate. 5

Tighten the 4 Allen screws using the supplied size 13 spanner. Position the controller box at the upper rear center of the base frame of the TC5 SMART or TC7 SMART heat press and let the studs at the controller box slide into the slots on the heat press base. Securely tighten the hand nuts. Attach the small 6-pin plug from the rear side of the heat press base to the appropriate socket on the outer right side of the controller box. 6

Attach the large 5-pin plug from the surface of the heat plate to the appropriate socket on the right outer side of the controller box. Plug the supplied C13 cold device cable into the back of the controller box and connect it to a safety socket, which must be equipped with a grounded connection, protection via fuse and ground fault circuit interrupter. The TC5 SMART or TC7 SMART heat press is now ready for use. 7

Controller components and operation Display components and their meaning Area for time setting and countdown when press is closed 8

Area for time setting and activity indicator of the pre-press feature Icon for the Bluetooth connection General indicator for fault or error Area for temperature indicator for target temperature and actual temperature Indicator: Heat plate's heating active Indicator: Press is done heating up Indicator: Press is currently heating up or cooling down. If below the set temperature, up arrow will flash. Indicator for management of memory slots Counter for counting the performed press operations How to use the controller Setting the temperature: Briefly press, the symbol in the display starts flashing. The value in the display changes from the current ACTUAL value to the TARGET value, which can now be set. Turn clockwise to increase the TARGET temperature, counterclockwise to decrease. 9

Press the rotary knob or press to store the set value. If no input occurs for 5 seconds, input mode ends automatically. Pressing exits input mode, the set value is not applied and the display returns to the current ACTUAL value. Temperature-related indicators: is activated whenever the heater is running. During the warm-up phase, every 10s an estimated remaining warm-up time scrolls across the display for 3s instead of the current temperature. is activated when the CURRENT temperature corresponds with the TARGET temperature, allowing for a certain deviation of X. Arrow up is activated when the temperature is rising (if below TARGET temperature, arrow is blinking), arrow down is activated when the temperature is dropping, e.g. during a transfer or if the heat plate is still hotter than the set target temperature. is generally activated in the event of faults or errors, and when there is a significant deviation between TARGET and CURRENT temperature (value outside of a range that allows for pressing). Setting the time: push briefly, symbol in the display flashes. Turning the rotary knob clockwise increases time, counter-clockwise decreases. Press the rotary knob or press store value. If no input occurs for 5 seconds, input mode ends automatically. Pressing to will exit the input mode, the display will return to its original value. 10

Configuring pre-pressing: Briefly pressing activates pre-pressing for the following press operation using the preset time, and is deactivated again upon completing the press operation. When activated, the Time+Pre symbol will light up in the lower part of the display with the corresponding time indicator. This will count down to 0 while pressing, whereupon the symbol and time switched off again. Holding activates the setting mode for the PRE time analog with time setting: Symbol in the display flashes. Turning the rotary knob clockwise increases time, counter-clockwise decreases. Press the rotary knob or press no input occurs for 10s, input mode ends automatically. Pressing input mode, the display will return to its original value. to store value. If will exit the Pre-pressing can be activated permanently from the settings menu. More information below. Saving to and loading from memory slots: Press and hold rotary knob in the default state. flashes. The number corresponding with the memory slot is shown below the disk. This indicator rises by one when turning the rotary knob clockwise. Each stored temperature value and time / PRE time value is also displayed at the top. If memory slot is blank, dashes are displayed for temperature and time / PRE time. To retrieve a stored value, confirm the selected value in the display by briefly pressing the rotary knob. The stored values are now displayed, flashes. is deactivated and no longer To save the current values (to blank or currently used memory slots), first push and hold the rotary knob ( flashes), then select the desired memory slot, then hold the knob until the values and symbols flash briefly. The values are now both, saved and loaded, 11

no longer flashes, the memory mode has been exited. Setting tier: Press. You generally navigate through the setting tiers according to the following scheme: Rotate knob - scroll through the settings. Press knob - dive into current setting. Rotate knob - choose values within the setting. Press knob - store value and exit from the setting. You may press to return to the parent tier if no action is to be taken in the subordinate tier. The following eight menu items are available in the setting tier. 1. Auto Prepress Enable / Disable a permanent pre-pressing. 2. Bluetooth Enable / Disable Bluetooth. 3. Bluetooth PIN You can use the rotary knob to save your individual PIN, which the app will then prompt you to enter. The default PIN from factory is 255, which is automatically recognized and used by the app. 4. Warning signal Enable / Disable the warning signal before opening the press. 5. Sleep Mode Setting the time interval in minutes, after which the press enters the Sleep Mode. In addition, the temperature the press should be cooled down to when in Sleep Mode can also be set. To completely disable Sleep Mode, set the time value to "0". 12

The active Sleep Mode can be exited at any time by pressing any button or by actuating the press lever. The press will then restore the previously set parameters. 6. Auto Off Setting the time interval in minutes, after which the press completely turns off the heating. To completely disable Auto Off Mode, set the time value to "0". The active Auto Off Mode can be exited at any time by pressing any button or by actuating the press lever. The press will then restore the previously set parameters. 7. Language Setting the menu language. 8. Unit Configuring the temperature unit. Celsius or Fahrenheit are possible. Resetting the counter: Press the button for 2s, display flashes briefly, values are set to 0. Pair heat press with mobile device Press the key on the controller Enable Bluetooth: Use the wheel to scroll to the Bluetooth ON/OFF setting and press the wheel once. Now turn the wheel again to set Bluetooth to ON and confirm again by pressing the wheel. Setting the Bluetooth PIN: Use the wheel to scroll to the Bluetooth PIN setting and press the wheel once. Now turn the wheel again to set the desired Bluetooth PIN and confirm again by pressing the wheel. The default PIN is 255. Press the Settings button on the controller to exit the Settings menu Download the Secabo Smart Transfer App to your mobile phone and start it. The first time you start the app, you will receive a brief introduction that will help you understand the features and benefits of the app. After the introduction, a dialog opens, which will assist you with connecting the press to the app. The app automatically searches for Secabo Smart heat presses in the area. Please make sure that Bluetooth is activated on your smartphone. Simply select the respective heat press from the list to connect to it. If you have changed the Bluetooth PIN on the heat press, the app will prompt you to enter it in the app. 13

The heat press is now connected and ready for use. Controlling the heat press via Secabo Smart Transfers app To learn how to control your Secabo TC SMART Transfer Press via the Secabo Smart Transfer App, please refer to the app introduction as well as the help pages within the app. Second setting tier for operational key figures and service Press and hold the Settings button to enter the second tier of the settings. Here you can retrieve helpful data and counter readings by turning the rotary knob. 1 Service Tag 2 Firmware version 3 Serial number of the controller 4 Long-term counter press operations 5 Operating hours counter in hours 14

Operation of the heat press Performing transfers Turn on the heat press via the main switch. The press will now heat up to the set temperature. Please refer to previous chapters to learn how to change the settings on the controller. Once the press has heated up, you can proceed with the first transfer. The clock starts counting as soon as the press is closed with the press lever. 3 seconds before the set time elapses, a warning signal is sounded (if activated in the settings), then the press opens automatically. You can adjust the contact pressure by turning the large hand screw at the top of the press to increase or decrease the distance the lever travels. Turning the knob clockwise increases the pressure, while turning it counterclockwise decreases it. No settings can be changed during the press operation. With each completed press operation, the value indicated by the counter increases by one, as soon as the specified time has fully elapsed. Note: Please keep in mind that it takes some time for the press to cool off after it is switched off. 15

Maintenance and cleaning All maintenance work must be carried out with the press switched off and cooled off, no exceptions! First, remove the plug from the wall socket. Only perform maintenance work after consultation with our technical support team. The press should be cleaned regularly using a soft cloth and a mild household cleaner to remove adhesive residues, dust, etc. Do not use scouring sponges, solvents or gasoline! 16

Recommended times and temperatures These values should only be considered as guideline values, may vary depending on the material and must be checked before pressing. Material Temperature Pressure Press duration Flock film 170 C - 185 C low-medium 25s Flex film 160 C - 170 C medium-high 25s Sublimation flex 180 C - 195 C medium-high 10s - 35s Sublimation on mugs 200 C medium-high 150s - 180s Sublimation on tiles 200 C high 120s - 480s (depends on the thickness of the material) Sublimation on puzzles Sublimation on mouse pads Sublimation on garments Sublimation on metal plates 200 C low-medium 25s 200 C medium 20s - 40s 200 C medium-high 30s - 50s 200 C high 10s - 50s (depends on the thickness of the material) Important note: You should perform your own tests with the respective transfer materials and carrier media prior to each production. The aforementioned values, as well as any manufacturer specification merely serve as indications. Washing resistance and behavior during the transfer must be determined by performing your own tests. No guarantee can be derived from the recommended values. It is always the user's responsibility to determine and apply the correct settings for his specific conditions. Note on garment finishing processes: After the press operation, garments must cool off before any carrier media can be pulled off the transfer material. The hot glue in the transfer material doesn't develop its adhesive strength until cooled off. If the glue does not stick in 17

its cold state, this may indicate that the pressing procedure was too cold or too short. 18

Technical data Heat press Secabo TC5 SMART Secabo TC7 SMART Type automatically opening modular clam press Working area size 38cm x 38cm 40cm x 50cm Max. opening angle 40 Max. temperature 220 C Max. preset time Max. working pressure Pressure setting 999s 250g/cm² Height-adjustment of the heat plate via hand wheel Power supply 230V / 50Hz - 60Hz, 1.8kW 230V / 50Hz - 60Hz, 2.0kW Environment + 5 C - +35 C / 30% - 70% relative humidity Weight 32kg 38kg Weight with packaging Closed dimensions (W x H x D) Open dimensions (W x H x D) Heat press base and controller box: 21.5kg Heat plate and base plate 17.6kg 41cm x 57cm x 73cm 41cm x 93cm x 67cm Heat press base and controller box: 21.5kg Heat plate and base plate 23.5kg 43cm x 57cm x 75cm 43cm x 93cm x 74cm 19

Declaration of conformity - Statement of Conformity We hereby declare under our sole responsibility that the product referred to in "technical data" complies with the provisions of the following directives and standards: We herewith declare under sole responsibility that the under technical data mentioned product meet the provisions of the following EC Directives and Harmonized Standards: EC directives / EC directives: 2006/95/EC Low Voltage Directive 2006/95/EC Low Voltage Directive 98/37/EC Directive on machinery (2006/42/EC from 12/29/2009) 98/37/EC Directive on machinery (from 2009-12-29: 2006/42/EC) Standard / Standard: EN 60204-1:2006 Technical documents at / Technical documents at: Secabo GmbH, Hochstatt 6-8, 85283 Wolnzach, Germany Dipl. Ing. Fabian Franke Dipl. Ing.(FH) Bernhard Schmidt 20