Operation Manual ler SMS Air Conditioner Remote Control Controller Model No.: SR-001 Please read these instructions before operating your product and retain them for future reference. The images shown in this manual are for illustrative purpose only.
Thank you for purchasing our product. This smart unit is not only a remote controller of your air conditioner/heat pump, but also a remote monitor of your room temperature. All operations are based on GSM network SMS (Short Message Service) platform, thus you can do remote control/monitoring anywhere and anytime. It also provides a prompt, economic pre-warning method on high/low temperature and power dump. While your room temperature is too high/low, or the power supply is off/resumed, it will automatically send you an alarm message. Please take a while to read this manual, then follow the instructions to finish your settings. After that, just relax and enjoy it!
Hardware introduction Front view Back view How to use the keypad : Return key, to cancel an operation or delete a number; : Equals to OK key; : Factory reserved, equals to call up key. : Power on /off
Installation Insert a SIM card (GSM card only, typically 3.0V), install the Lithium-ion battery, then press the power key (hold the key above 3 seconds) to initialize the system. Keep waiting several seconds until it access your local GSM network, the start-up software interface displays as below: Press OK or key to enter main menu, then choose Settings, it will display 3 submenues: User List,Temp. Alarm,and Power Alarm. Set up an user list. It is a necessary step to start up all built-in functions. Manually input 1~3 mobile phone no.(s) including the area code. ( DO NOT input the SIM card No. of the system itself), only the registered phone no.(s) can access the system and get the pre-warning messages. Don t forget the phone no. prefix!
Country Area a Code Phone No. Prefix Denm ark 45 45 or 0045 Sw eden 46 46 or 0046 Norw ay 47 47 or 0047 Ice land 354 354 or 00354 Finland 358 358 or 00358 China 86 86 or 0086 Enable the firewall. We strongly recommend you to select this key. If you choose Disable, system will lose its security protection features, that means everybody can control your air conditioner by sending SMS command via mobile phone) Enter Temp. Alarm submenu, set the temperature for Freeze Alarm and Heat Alarm. The temperature value will be a trigger for pre-warning, once your room temperature reaches your set point, you will get an alarm message. Settings--Temp. Alarm-- Freeze alarm, set a temperature between 1~10 degree C (such as 9.2 degree C), then Enable the Freeze Alarm ( This means once your room temperature drops to 9.2 degree C, you will get an alarm message)
Enter Temp. Setting submenu, the default temperature value for Freeze Alarm is 8 degree C,Press Edit key to input a new value,the temperature span is within 1 ~10. Settings-- Temp. Alarm--Heat alarm, set a temperature between 26~46 degree C (such as 31.5 degree C),then Enable the Heat Alarm ( This means once your room temperature reaches 31.5 degree C, you will get an alarm message) Enter Temp. Setting submenu. the default temperature value for Heat Alarm is 32 degree C, Press Edit key to input a new value, The temperature span is within 26 ~46, Enable Power alarm Settings--Power alarm, select the "Enable" button, (This means once the city power is off/resumed, you will get an alarm message ).
This unit works by intelligently learn the infrared signals from a certain remote controller of air conditioner. Enter IR Codes submenu, input the IR (Infrared) codes. This is a necessary step to remotelly control your Air Conditioner. IR codes-- Code learning, one by one input 1~6 IR codes to the system, (For simple operation, just input 2 or 4 common codes is OK); Once you see a note "Point your remote controller at me, then press a proper button", Immediately use your handheld remote controller to "Shoot" the unit, it will automatically capture the IR code and store it into the memory. The operation need to be finished within 3 seconds, otherwise you will get a Fail feedback. Reception of IR codes can be checked by pressing TEST key after Code Learning is finished. If an infrared reception sound (such as beep) from the air conditioner can be
heard, it indicates the IR codes has been successfully received. IR codes-- Code test, one by one test the IR codes you have input to the system. Command List Users can compose short message command to do remote control/monotoring. Status Status command : System will check its surrounding environment and feedback the real time room temperature, GSM signal strength, power supply status; *01* *01* command : System will transmit Code 1 to Air conditioner, then feedback a Set OK message; *02* *02* command : System will transmit Code 2 to Air conditioner, then feedback a Set OK message; *06* *06* command : System will transmit Code 6 to Air conditioner, then feedback a Set OK message; Specifications: GSM 900 / DCS1800MHz dual frequency Infrared signal transmitting distance: 10m Power supply: DC 5.0V power adapter Lithium-ion battery: 3.7V 1000mAh Recharge limited voltage: 4.2V In door use only.