All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Similar documents
CP+ Gas & Oil Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

PT Radiant Heater Range

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

BENSON.... Variante3 Fired Unit Heaters...

NVxEA External Gas Unit Heater

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

HEM Heat Exchange Modules

BENSON HEATING INSTALLATION OPERATION AND SERVICING MANUAL

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

RHC GAS FIRED HEATING COILS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

PREEVA air handling unit

BENSON VARIANTE 2 RANGE

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

VPC Gas Cabinet Heater Range

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

RHC & RHCE gas fired heating coils

Sirius FS. Working towards a cleaner future

BENSON OIL UNIT HEATER 2 RANGE

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

BENSON VARIANTE 2 RANGE

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

pressurejetrange Buccaneer GTE, Falcon GTS, Harrier GTS, Viceroy GTS, Viscount GTS, Vanguard L Pressure jet boilers kW

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

BENSON GAS UNIT HEATERS

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

BENSON LINEAR RADIANT TUBE

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Gas-fired unit heaters for indoor installation

CPx Gas & Oil Cabinet Heater Range

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

... UDSA - UDSBD Gas fired unit heaters...

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

NVx Suspended Gas Unit Heater

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

BENSON CABINET HEATER

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

CAST IRON ATMOSPHERIC BOILERS

AMBIRAD.... Vision Radiant Tube Heating Systems...

Pressure Jet Boilers. Pressure Jet Range. Commercial Heating Solutions.

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

RS/UHC / UF RS/UHC-2 / 2UF

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Heat Exchanger models

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Cast Iron Boilers. G Series ( kW)

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

AB RANGE GAS FIRED ROOM SEALED AIR CURTAIN INSTALLATION AND OPERATING MANUAL

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

HEC - High Efficiency Condensing Heaters. Warming the workplace. 12kw to 1000kw Efficiency of up to 109% Nett High/Low or Fully Modulating Heater

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)


Pressurisation units & expansion vessels

Warm Air Cabinet Heaters

INSTALLATION & SERVICING MANUAL FOR BENSON PV TUBULAR CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

INSTALLATION & SERVICING MANUAL FOR BENSON GAS FIRED CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Xcell 270 Longlife DC wholehouse heat recovery unit

SKYPAK II, 3 Ton Series, gives you a

Domestic & Commercial Fans

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Direct Fired air handling unit

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

VORTEX BLUE OIL RANGE

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

VORTEX BLUE OIL RANGE

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR VARIANTE² BI DIRECTIONAL NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Boiler Product Range

1. GENERAL SAFETY RULES

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

GAS FIRED AIR CURTAIN AB 175, AB 225

Transcription:

All Heaters Part L2B Compliant Technical Data External Oil and Gas Cabinet Heaters For Models EVD Vertical Ducted EHD Hortizontal Ducted

Range & Configuration Vertical Forced Draught Oil and Gas 29 kw to 81 kw Horizontal Forced Draught Oil and Gas 58 kw to 81 kw Specification Cabinet: Machine punched and folded to form a robust monocoque cabinet with access to the burner and controls compartment via a front located access door. For added weather protection all external panels are manufactured from electro-zinc plated steel and then finished with stove hardened epoxy powder coat with a durable Kestrel Grey paint finish. All cabinets are IP44 rated. Heat Exchanger: The combustion chamber/ heat exchanger assembly has been designed to combine optimum thermal efficiency with extended service life. Manufactured from 04/16 stainless steel each fabricated assembly comprises of a drum type combustion chamber coupled to a tubular heat exchanger. Burner: All oil and gas fired cabinet heaters have been carefully matched with a fully automatic packaged pressure jet oil or forced draught gas burner. Oil fired cabinet heaters are complete with factory fitted fire valve and oil filter. Models 1200 and 100 oil and 100 gas are fitted as standard with high/low burners. High/low and modulating gas burners are available as an option for models 200 and above. Efficiency: Each heater within the range has been designed and developed with fuel efficiency in mind and efficiencies exceed the mandatory requirements of CE legislation. Additionally for the United Kingdom market all heater efficiencies are compliant with the needs of Part L2B of the 2006 Building Regulations whilst most models within the range have also been rated to meet the criteria necessary for inclusion into the Enhanced Capital Allowance (ECA) scheme. Fuel: Oil heaters are design to operate on Class D light distillate gas oil having a maximum viscosity of 4.5 c.st at 20 o C (5 sec Redwood at 100 o F). Forced draught gas heaters can be specified to operate on either natural gas (G20) or Lpg Propane (G1). Most oil fired models can be operated on kerosene. Fan: Air movement is provided by either a single or duplex forward curved blade dynamically balanced centrifugal fan assembly complete with double inlet rotors. Fans on models 100-00 are powered by integral motors whilst all others employ pulley and belt drive arrangements. Air Distribution: Air is discharged through a duct outlet spigot located on the top face of a vertical heater and on the left hand or right hand end of a horizontal heater. Generally return air to the heaters is via a duct spigot located on either the left hand or right hand side of a vertical heater (a rear located spigot is an option for certain vertical models) or, for horizontal heaters, return air entry is on the opposite end of the heater to the duct outlet spigot. However heaters can, as an option, be fitted with fresh air inlet louvres. Controls: Benson cabinet heaters are supplied ready for fully automatic operation and are complete with both safety and comfort controls. Each heater is fitted with a safety overheat thermostat as well as a time and temperature control system. Two alternative control options are available. As standard, heaters are offered with a digital time switch, mechanical day temperature and frost protection thermostats. Alternatively heaters may be specified with an optimised control that includes a secure entry code facility, an optimised digital time switch with override facility, electronic day thermostat and frost protection thermostat. Unless otherwise specified the controls for both vertical and horizontal external heaters are housed within a console for remote mounting. Inter-connecting wiring between heater and remote consoles is by others. All heaters have the facility of fan only operation for summer air movement. Testing, Approvals & Certification: Benson Heating is accredited with ISO 9001 quality assurance certification certificate number FM1492. All gas fired heaters have been type tested by an independent notified body and conform to CE requirements. Each heater is inspected and test fired prior to despatch. Guarantee: Benson cabinet heaters are provided with a comprehensive package of guarantees covering both the appliance and the combustion chamber/heat exchanger, which has the further benefit of an extended guarantee. For sales within the United Kingdom the guarantee includes a whole appliance twelve months parts and labour guarantee supported by a further twelve months parts only guarantee whilst the combustion chamber/heat exchanger assembly has a ten year time related warranty. For cabinet heaters supplied to overseas markets please refer to the relevant country documentation. All guarantees are subject to terms and conditions.

Specification External Vertical & Horizontal Cabinet Heaters EVD/EHD Model 100 125 150 200 250 00 400 500 600 700 800 1000 1200 100 Vertical Only Vertical & Horizontal Output kw 29 6 4 58 7 86 117 12 177 205 25 284 50 81 ECA Approved Airflow m /s 0.61 0.71 0.71 1.0 1.9 1.9 2.15 2.65.11.40 4.2 4.86 6.88 6.88 Airside Data Fan Standard Pa 75 100 100 125 100 100 17 150 175 188 125 175 250 250 Static Up-rated Pa n/a n/a n/a n/a n/a n/a 175 200 225 225 188 225 n/a n/a Electrics Standard V/ph/hz 20/1/50 415//50 Optional V/ph/hz n/a 415//50 20/1/50 n/a Height mm 1665 1665 1665 1915 1915 1915 2040 2040 2140 2140 2125 2125 2712 2712 EVD Width mm 660 660 660 660 660 660 740 740 916 916 1100 1100 1244 1244 Overall Depth mm 1165 1165 1165 140 140 140 1590 1590 2200 2200 2400 2400 2550 2550 Dimensions Length mm n/a n/a n/a 1960 1960 1960 2085 2085 2185 2185 2170 2170 2757 2757 EHD Width mm n/a n/a n/a 1661 1661 1661 1801 1801 2456 2456 2676 2676 2816 2816 Height mm n/a n/a n/a 750 750 750 80 80 1006 1006 1440 1440 1590 1590 Flue Diameter mm ø 125 125 125 150 150 175 175 175 200 200 225 225 250 250 Combustion Air Spigot mm ø 125 125 125 125 125 125 150 150 150 150 150 150 150 150 Noise Level dba 62 64 64 67 67 67 69 70 72 72 7 74 74 74 Nett Weight EVD kg 20 20 20 280 280 280 80 80 595 610 720 75 1200 1200 HVD kg n/a n/a n/a 00 00 00 400 400 625 640 750 765 1240 1240 Note Where heaters are selected for the UK Enhanced Capital Allowance (ECA) scheme then they must be specified with CP4 controllers All models have efficiency levels which meet with the minimum efficiency requirements of UK Part L2B Building Regulations Air handling data is assessed at room ambient conditions Overall heater height excludes flue and cowl - for more detailed dimensions refer to dimensions page Overall dimensions model EHD include base frame. Noise levels are for units with both inlet and outlet ductwork attached and measured m from appliance

Installation Installation Standards: Benson oil and gas fired external cabinet heaters must be installed and commissioned by a competent person and in accordance with Benson s installation and commissioning instructions, relevant local and national standards, Codes of Practice, and any requirements of Local Authorities, Fire Officer or insurers. Siting: The position chosen for the heater will need to take account of the following points - External cabinet heaters are specifically designed for external location and must be positioned on a flat, level and noncombustible surface. Care should always be taken to ensure that any base, platform or structural steelwork supporting the heater is structurally adequate and that there is both access and provision for maintenance purposes. Care should be taken to ensure that the recommended clearances are maintained and that there is sufficient space for the connection of discharge and/or return ductwork or, if fitted, that there is sufficient clearance for the passage of air to the fresh air inlet weather louvre. Consideration should be given to the location of the appliance so that the flue exit point does not discharge exhaust gases beneath or adjacent to doors, windows, building overhangs or in passageways. So far as controls are concerned siting will often depend upon the type selected. Where controls have in-built or remote temperature sensors then consideration should be given to ensure that the sensor is located in a position which adequately reflects the working zone serviced by the heater. Sensors should not be located in areas subject to cold draughts. In case of doubt relating to any aspect of heater or control siting please consult with Benson. Air Supply: External cabinet heaters are designed specifically for outdoor location and as such obtain necessary combustion air directly from an external source. Care should be taken to ensure that the combustion air inlet louvre or combustion air duct (if fitted) is not modified, repositioned, damaged or in anyway restricted. Flues: External cabinet heaters are supplied complete with a flue kit which permits the free discharge of flue gases directly to atmosphere. For particular applications it may be possible to extend the flue to enable the point of discharge to be repositioned. However should this be necessary then the diameter of flue must not be less than stated in the data sections of this brochure. In the event that it is necessary to extend the flue then the route and exit point needs to be selected carefully and it is recommended that the installer consult the installation and commissioning instructions or Benson before commencing installation. Further Information: The foregoing is given for guidance purposes. More detailed information can be found within the relevant installation, commissioning and servicing instructions or alternatively contact Benson. Oil & Gas Pipework: The oil and gas supply pipework should be sized and installed with due regard to all relevant standards and legislation, flow rates and the maximum/minimum inlet pressure requirements of both oil and gas fired heaters. Isolating gas cocks, oil line gate valves and service unions should be provided for each heater. 4

Installation Data External Vertical & Horizontal Cabinet Heaters EVD/EHD Model 100 125 150 200 250 00 400 500 600 700 800 1000 1200 100 Vertical Only Vertical & Horizontal Fuel Oil BSP/Rc 8 ⅜ 8 ⅜ 8 ⅜ Connection Gas BSP/Rc ½ ½ ½ ½ ½ ½ ¾ ¾ 1 1¼ 1¼ 1¼ 1½ 2 Minimum Gas Inlet Nat Gas mbar 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 Pressure Lpg mbar 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 Oil l/h. 4.2 5.0 6.6 8.6 10.0 1.6 15.2 20. 24.1 27.1.0 7.5 44.5 Fuel Consumption Nat Gas m /h. 4.2 5.1 6.7 8.5 10.1 1.6 15. 20.2 24. 27.0.0 40.7 45.8 Lpg m /h 1. 1.7 2.0 2.6.4 4.0 5.4 6.0 8.0 9.6 10.7 1.0 16.1 18.1 20/1/50 Motor kw 0.55 0.55 0.55 0.99 0.99 0.99 1.50 2.20 n/a n/a n/a n/a n/a n/a FLC amp.2 4.8 4.8 6.0 7.2 7.2 12.0 14.0 n/a n/a n/a n/a n/a n/a Electrics 415//50 Motor kw n/a n/a n/a 1.0 1.0 1.0 1.5 2.2.0.0 4.0 5.5 n/a n/a FLC Amp n/a n/a n/a 2.2 2.2 2.2.6 5.2 6.5 6.5 8.4 11.0 n/a n/a 415//50 Motor kw n/a n/a n/a n/a n/a n/a 2.2.0 4.0 4.0 5.5 7.5 11.0 11.0 Up-rated Fan FLC Amp n/a n/a n/a n/a n/a n/a 5.2 6.5 8.4 8.4 11.0 14.0 24.0 24.0 Flue Diameter mm ø 125 125 125 150 150 175 175 175 200 200 225 225 250 250 Combustion Air Spigot mm ø 125 125 125 125 125 125 150 150 150 150 150 150 150 150 Front mm 500 500 500 500 500 500 600 600 600 900 900 900 900 900 EVD Side mm 150 150 150 150 150 150 150 150 150 150 400 400 500 500 Installation Rear mm 700 700 700 1000 1000 1000 1200 1200 1500 1500 2000 2000 2000 2000 Clearances Front mm n/a n/a n/a 500 500 500 600 600 600 900 900 900 900 900 EHD Top mm n/a n/a n/a 150 150 150 150 150 150 150 400 400 500 500 Rear mm n/a n/a n/a 1000 1000 1000 1200 1200 1500 1500 2000 2000 2000 2000 Nett Weight EVD kg 20 20 20 280 280 280 80 80 595 610 720 75 1200 1200 HVD kg n/a n/a n/a 00 00 00 400 400 625 640 750 765 1240 1240 Note Fuel consumption and output figures based upon gross calorific values as - Class D light distillate fuel oil @ 7.9 MJ/l Natural gas (G20) @ 7.78 MJ/m Lpg Propane (G1)@ 95.65 MJ/m Electrics details in bold refer to standard configurations, other configurations optional Clearances refer to heaters with standard return air louvre arrangements Models 1200 and 100 have an up-rated fan motor as standard 5

Dimensions External Vertical Cabinet Heaters EVD Model 100 125 150 200 250 00 400 500 600 700 800 1000 1200 100 A All mm 1620 1620 1620 1870 1870 1870 1995 1995 2095 2095 2080 2080 2667 2667 B All mm 660 660 660 660 660 660 740 740 916 916 1100 1100 1244 1244 C All mm 1165 1165 1165 140 140 140 1590 1590 2200 2200 2400 2400 2550 2550 D All mm 408 408 408 5 5 5 5 5 510 510 505 505 797 797 E All mm ø 125 125 125 150 150 175 175 175 200 200 225 225 250 250 F All mm 85 85 85 984 984 984 968 968 1068 1068 1054 1054 172 172 G All mm 570 570 570 64 64 64 714 714 890 890 1000 1000 1086 1086 H All mm 570 570 570 770 770 770 950 950 1120 1120 1450 1450 165 165 J All mm 640 640 640 690 690 690 770 770 945 945 110 110 120 120 K All mm 522 522 522 702 702 702 904 904 1078 1078 1145 1145 1150 1150 L All mm 48 48 48 427 427 427 542 542 692 692 654 654 796 796 6 Notes Side return air inlet spigot shown is optional and can be left hand or right hand side. Side must be specified at time of order Rear return air inlet spigot is optional and is available for certain models - details on request

Dimensions External Horizontal Cabinet Heaters EHD Note Heater shown is with airflow right to left. Left to right airflow optional - to be specified at time of order. Model 200 250 00 400 500 600 700 800 1000 1200 100 A All mm 1870 1870 1870 1995 1995 2095 2095 2080 2080 2667 2667 B All mm 660 660 660 740 740 916 916 150 150 1500 1500 C All mm 140 140 140 1590 1590 2200 2200 2400 2400 2550 2550 D All mm 5 5 5 5 5 510 510 505 505 797 797 E All mm ø 150 150 175 175 175 200 200 225 225 250 250 F All mm 984 984 984 968 968 1068 1068 1054 1054 172 172 G All mm 64 64 64 714 714 890 890 1000 1000 1086 1086 H All mm 770 770 770 950 950 1120 1120 1450 1450 165 165 J All mm 570 570 570 640 640 725 725 665 665 675 675 K All mm 1585 1585 1585 1725 1725 280 280 2600 2600 2740 2740 L All mm 1806 1806 1806 195 195 205 205 2020 2020 2610 2610 7

www.bensonheating.com Ludlow Road Knighton Powys LD7 1LP Telephone (main) + 44 (0)1547 52854 Facsimile (main) + 44 (0)1547 52099 Telephone (sales) + 44 (0)1547 529245 Facsimile (sales) + 44 (0)1547 529195 e.mail information@bensonheating.co.uk sales@bensonheating.co.uk exportsales@bensonheating.co.uk Benson Heating is a division of the Benson Group of Companies Limited Guarantees and warranties subject to terms and conditions. It is the policy of Benson Heating to pursue a programme of continuous development. We therefore reserve the right to change models, types, specifications and prices without prior notice. Details are believed to be correct but do not form the basis of any contract or guarantee. All orders accepted subject to our standard Conditions of Sale, copy available on request. November 2007