MUD TRAPS MUD TRAPS. Standard version (to install in consolidated sand) Reinforced version (to install in sand)

Similar documents
EuroPEK Oil Separator

Web:

NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it.

SMALLBORE PIPEWORK GREASE TRAPS SEPTIC TANKS / CESS PITS INTERCEPTORS

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

Homeowners Guide to Stormwater BMP Maintenance

CITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS

CHAPTER 10 TRAPS AND INTERCEPTORS

Tree Pits Construction Guide

Just The Basics: Illicit Discharge. What does it mean to me?

Uridan. Product Information. Uridan Waterless Urinals. Technical Details On Reverse Of Page

ACO Construction & Building Products

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section.

NZTIWF TECHNICAL GROUP

Roadware MatchCrete Clear. Standard Product Data Sheet

Preventing Storm Water Pollution: What We Can Do

StormStation TM Data Sheet

EuroPEK Roo Oil Separator

Preventing Storm Water Pollution

Preventing Storm Water Pollution

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

SOP 6: Erosion and Sedimentation Control SOP 6: EROSION AND SEDIMENTATION CONTROL

Procedural guide to the self-monitoring of trade waste pre treatment devices

SMALL PROJECTS SIMPLIFIED APPROACH

FATS, OIL AND GREASE (FOG) PROGRAM

Permeable Interlocking Pavers

ECOJET GREASE LEVEL SENSOR

Green Infrastructure Overview

INSTALLATION AND OPERATING INSTRUCTIONS

Who Needs BIG DIPPER?

MiniPEK sand, oil and fuel trap Installation, use and maintenance instructions

Cisterns To Collect Non-Potable Water For Domestic Use 1

Sewer & Storm Drain Systems

92 Minnesota Stormwater Manual

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

Water filtering system for optician

YOUR PRESSURE SEWER SYSTEM

Rain Gardens. A Welcome Addition to Your Landscape

CIRCULATORY AGITATION SYSTEMS FOR CONCRETE DAIRY MANURE STORAGE TANKS

Houses ALASKA BUILDING RESEARCH SERIES HCM N B I : A

5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

Air and dirt in closed systems

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps

DUKE UNIVERSITY CONSTRUCTION & DESIGN STANDARDS

Your Pressure Sewer System. A Homeowner s Guide

Fat, oil and grease is known as FOG in the drainage industry.

RAINWATER FILTERS AND REUSE OF RAINWATER

Operating instructions

F.O.G. 2/8/2013. Frequently Asked Questions. Defining Fats, Oils, & Grease (FOG)

Trade Waste in the Food Industry

Appendix D - Technical Design Criteria for BMPs

Low Flow Rates Low Filtration Sandy Soils Medium Flow Rates Medium Filtration Clayey Soils [1] High Flow Rates High Filtration Polluted Soils

CHAPTER 8 APPURTENANCES

What is Rainwater harvesting?

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4

SET A NATURAL EXAMPLE. Green roofs on small areas in the private sector

Lesson 2: Stormwater Best Management Practices (BMPs)

POND Construction. Perry L. Oakes, PE State Conservation Engineer Natural Resources Conservation Service

Sustainable Stormwater Management through Green Infrastructure. Jersey City Public School #5

Portable Pressure Washer

Domestic Water Tank Cleaning Machine

Installation, Operation, and Maintenance Manual. ASP HDPE Package Sewage Treatment Plants

Green Infrastructure and Low-Impact Development Technologies

Best Environmental Management Practices

Dry Ice Blasting Frequently Asked Questions

Infiltration basin under normal conditions, with generous grassed area for water soakage (Source: WSUD in the Sydney Region)

WH101F & WR101F Typical Installation Instructions & Warranty Information. Simplex Station

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

SIMPLIFIED APPROACH TO STORMWATER MANAGEMENT FOR SMALL PROJECTS

Gas Instantaneous Water Heater

Product Application Sheets

Outdoor cleaning products

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

Pureblast Dry Ice Cleaning Equipment

Residential Stormwater Credit Application

Electrostatic Precipitator

Design of Precast Concrete Grease Interceptors

INTRODUCTION TO GREEN INFRASTRUCTURE HOW WE CAN PROTECT OUR COMMUNITIES AND OUR WATERS Maywood Public Library Bergen County, New Jersey

Grease Interceptors and Oil Separators

Residential Stormwater Credit Application

20 gal per person per day.

SUBMERSIBLE DIRTY WATER PUMP

HS Series Installation & Operating Instructions RadonAway

2.1.4 Roof Downspout Rain Gardens

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

Name. There are three main types of soils called textures. They are: sand, silt, and clay. Sand has the largest particles and clay has the smallest.

INSTRUCTION MANUAL KETTLE

COOKING GREASE ITS EFFECT ON OUR WATER INFRASTRUCTURE

TABLE OF CONTENTS HOW AIRBORNE CONTAMINATION IS REMOVED 3 DIMENSIONS 4 SPECIFICATIONS 6 PLANNING THE INSTALLATION 7 ASSEMBLY & INSTALLATION 10

Home owner s manual Pressure sewerage system

Modular Grease Trap MGTA

Operating Instructions

2015 UPC Chapter 8 Indirect Wastes RV

Capillary Action Subsurface Irrigation

Protect Stormwater Quality Project and Site Management Training for General Contractors. Presenter Becky Pearson Professional Civil Engineer

Transcription:

MUD TRAPS MUD TRAPS Standard version (to install in consolidated sand) Reinforced version (to install in sand)

Table of contents What is a mud trap 3 Advantages 3 Characteristics 3 Functioning 3 Installation requirements 7 Maintenance 8 Warranty 8 Other documents 8 Boralit Mud traps - Version 2018 Belgium - English 2

WHAT ARE MUD TRAPS? What is the function of a mud trap? A mud trap is a system in the sewers, which serves to perceptible dirt from the waste water. This prevents certain undesirable substances clog or damage the sewer system. ADVANTAGES: Easy to install because of its light weight Tanks are easy to clean because nothing sticks on PE. So entering the tank is not necessary. Guarantied watertight Now possibility that roots grow trough the tank. The tank is corrosion resistant. The reinforced horizontal septic tanks equipped with 2 lifting eyes. Equipped with a plastic cover that must be replaced by a steel ore plastic cover that meets the legislation. All tanks have a welded riser. CHARACTERISTICS A mud trap removes sediments (sand, mud, grit, settable solids, ) from the wastewater. The installation of a sediment collector may be necessary in the following circumstances and may be used together with a hydrocarbon and / or grease trap separator: In garages, car-washes, car parks,... These are places where there is always a chance that hydrocarbons might be discharged. In hotels, restaurants, bars, schools, butchers, caterers,.. These are places where there is always a change that vegetable or animal fats might be discharged along with other sediment. When there is a chance that sediments might enter an installation, causing blockage. A mud trap or grease trap can be obligatory, please consults your national and / or local legislation and environmental regulations. The minimum volume of the mud trap: In combination with a hydrocarbon separator: Class 1 (slightly polluted water): 100 x the flow of the separator e.g. brand dealer. Class 2 (polluted water): 200 x the flow of the separator, e.g. car washes. Class 3 (heavily polluted water): 300 x the flow of the separator, e.g. cleaning of farming. In combination with a grease trap: 40 liters per second of the grease trap, e.g. grease trap 10 l/s, mud trap = 400 liter. The mud trap has been designed in accordance with the EN 1825-1 standard and meets with the following demands: Liquid surface: 0,25 m² per liter per second Retention time: 3 minutes Performance: 92% All are equipped with an adaptable riser. Please contact our technical service to help with the calculation of the right mud trap. FUNCTIONING The water loaded with sediment enters the tank by means of an anti-splash jet-nozzle. Because the sediment has a higher density (it is heavier) than the water in the tank, it starts to settle down. The water that flows out of the separator is nearly sediment-free. Boralit Mud traps - Version 2018 Belgium - English 3

Mud traps Standard version 300, 500 and 850 liter SV300 SV500 SV850 Installation in 15 cm consolidated sand 300 liter 1,5 l/s mud trap - 830 mm (C) 760 mm (B) 1.550 mm (A) in 915 mm (E) out 875 mm (G) 35 kg Price - C01 674,15 Installation in 15 cm consolidated sand 500 liter 3 l/s mud trap - 1.100 mm (C) 760 mm (B) 1.550 mm (A) in 915 mm (E) out 875 mm (G) 55 kg Price - C01 818,76 Installation in 15 cm consolidated sand 850 liter 6 l/s mud trap - 1.500 mm (C) 1.050 mm (B) 1.550 mm (A) in 915 mm (E) out 875 mm (G) 90 kg Price - C01 1.085,07 Boralit Mud traps - Version 2018 Belgium - English 4

Reinforced version 1.100, 1.600, 2.400, 3.300 and 6.000 liter SV1100 SV1600 SV2400 1.100 liter 1,5 l/s mud trap - 1.180 mm (C) 1.180 mm (C) 1.910 mm (A) in 1.250 mm (E) out 1.200 mm (G) 61 kg Price - C01 831,14 1.600 liter 3 l/s mud trap - 1.290 mm (C) 1.290 mm (C) 2.250 mm (A) in 1.500 mm (E) out 1.450 mm (G) 71 kg Price - C01 1.029,33 2.400 liter 6 l/s mud trap - 2.350 mm (C) 1.350 mm 1.850 mm (A) in 1.220 mm (E) out 1.180 mm (G) Diameter in/out 125 mm (F) 110 kg Price - C01 1.625,12 Boralit Mud traps - Version 2018 Belgium - English 5

SV3300 SV6000 Options 3.300 liter 10 l/s mud trap - 2.390 mm (C) 1.610 mm 2.210 mm (A) in 1.450 mm (E) out 1.400 mm (G) Diameter in/out 160 mm (F) 180 kg Price - C01 1.981,85 6.000 liter 20 l/s mud trap - 2.400 mm (C) 2.070 mm 2.470 mm (A) in 1.850 mm (E) out 1.800 mm (G) Diameter in/out 200 mm (F) 270 kg Price - C01 2.805,56 Plastic pedestrian cover Boralit: KDB C Level alarm: Gray 700 mm 700 mm 145 mm Diameter opening 590 mm 20 kg Price C05 137,49 - KANA 3: SAND SET 1000. Gives a signal when the installed level is reached. Type Price C05 Kana 3 2.977,60 GSM module: sends an sms when an alarm message occurs on the KANA alarm Type Prijs C05 GSM module 240,00 Boralit Mud traps - Version 2018 Belgium - English 6

INSTALLATION PROCEDURES, MAINTENANCE AND WARRANTY The client acknowledges to have received a copy of this and agrees. The installation requirements should be read FIRST BEFOR placement. In the event of loss by the customer of the installation requirements the customer must always ask for a new copy of the installation requirements at Boralit nv, or download them from the Boralit Web site. INSTALLATION PROCEDURES IN CONSOLIDATED SAND They apply to the standard tanks. Always install the facility as closely as possible to the contamination source to prevent the feeder pipe from clogging and causing blockages (excepted for rainwater tanks). Prepare a pit that is at least: 15 to 20 cm broader than the tank 15 to 20 cm deeper than the distance between the height of the inlet and the bottom of the tank. See to it that all groundwater or rainwater that might be present in the pit is pumped out before pouring consolidated sand into the pit. The bottom of the pit must be covered by at least 15 cm of consolidated sand of 150 Kg/m³ (*). Level (with a builder s level) the grease trap in the pit so the inlet is at the proper height to connect to the house drainpipe. Fill the grease trap with water and connect both the inlet and outlet. Provide with correct and sufficiently large ventilation according to the type of unit and always with a minimum of 50 mm. Backfill the pit round the unit with at least 15 cm of consolidated sand of 150 Kg/m³ (*). Always introduce small amounts of consolidated sand, slightly press the sand to prevent distortion of the unit. Put at least 10 cm of consolidated sand of 150 Kg/m³ (*) on top of the grease trap. Install the PE-risers, which can be obtained from Boralit, on the unit until ground level is reached, and put the cover on (the grease traps must remain easily accessible for inspection and cleaning). In case vehicles might drive in the immediate surroundings of the installation, a sufficiently strong concrete slab must be installed. The concrete slab should not rest on the tank and should divert the pressure to the ground that has not been disturbed. (*) Please contact us in case of a temporary high groundwater level, and also if the tank becomes more deeply embedded in the ground than is permitted by the PE-riser. INSTALLATION PROCEDURES IN REGULAR SAND They apply to the reinforced tanks. Follow above instructions and If there is no groundwater, the consolidated sand can be replaced by regular sand. Please contact us if the tank becomes more deeply embedded in the ground than is permitted by the PE-riser. The PE covers are only temporarily. They do not have a safety lock and can not stand the weight of persons or vehicles who might pass by. Make sure you get Boralit covers, to increase the security of persons or vehicles who cross the installation. Boralit Mud traps - Version 2018 Belgium - English 7

MAINTENANCE The storage capacity is limited. That means that the installation must be empetyed regulary when the installation is saturated. We advice to check the installation regularly and to remove all mud and sediment. If the tank has collected too much dirt, it has to be cleaned and refilled with water. WARRANTY We offer a 10-year warranty on all our tank products as far as evident manufacturing faults are concerned. Failure to comply with installation procedures and guidelines voids warranty. 2-year warranty on all parts. The general sales and warranty conditions of Boralit count. OTHER DOCUMENTS These documents are also available: - Range mud traps. - Manual for alarm KANA 3 Boralit Mud traps - Version 2018 Belgium - English 8