ARGUS Smoke Detectors. The next generation. Safety and security electronics

Similar documents
½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

Protecting you and your home

SMOKE User Manual. NE v2.0

Mounting Instructions for Genius Hx

Alarm System SECURE AS 302

PACK TRAVEL INSTRUCTION MANUAL

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

DANGER DETECTORS 2016 RANGE

Consultant Specification AGILE Wireless Fire Detection System

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

X-Series Smoke and Heat Alarms

Operating instructions for the radio heat detector GS412

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Synco living. Train the Trainer. Mounting Safety Devices. August 2007 Page 1/11 Train the Trainer - August 2007

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Synco living. Train the Trainer. Commissioning Safety & Security. Spring 2008 Page 1/21 Train the Trainer - Spring 2008

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Radio fire warning panel SRC 3000

SecuriFire SecuriLine extended board B5-DXI2

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

User Manual 120/240/300 Outdoor Motion Detector

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

The new detector from Rafiki

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

ICH110. Climate Chamber. Product specification

ARGUS movement detectors

ICH260C. Climate Chamber. Product specification

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

ICH750L. Climate Chamber. Product specification

OH110, OP110, HI110 Automatic fire detectors

ICP450. Compressor-cooled incubator. Product specification

Line Smoke Detector LRMX

Operating Instructions Version 1.2

Contents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

THE BELLMAN & SYMFON WAY Visit technical training

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

OPERATING INSTRUCTIONS. G214 Software - Version 4

Operating instructions for the wireless smoke alarm detector type: GS558

SMOKE & HEAT DETECTOR

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Analogue addressable devices

Synova TM product catalog.

OH720, OP720, HI720, HI722

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Contents. Most Trusted and Best Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm.

RMS-I-DE-01 Smoke Detector

PLEASE READ THIS USER GUIDE CAREFULLY

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

Description. Optex Incorporated

FLAME AMPLIFIER MODULE 3001

Carephone 52 Security You Can Feel

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Accessories for Alarm Systems in the Protect Series. Instruction Manual en/en

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

User guide. for smoke detector

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

BM Programming Module. For the heating engineer Installation instructions

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Smoke Alarm User s Manual

Series 65 Product Guide MAN 3036

Digital Thermometer with Ice Alert and Clock

Air Comfort. Installation instructions (English) A

SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

>WIRELESS> ALARM SYSTEM CR200

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

Remote alarm unit Art. Nr.:

DUR-4047 WIRELESS RADIO UNIVERSAL SMOKE OPTICAL DETECTOR

Fireray 2000 Linear Smoke Detector

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Chromatographic Air circulated Refrigerator, two-door TC 603

FCP 320/FCH 320 Conventional Automatic Fire Detectors

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group

Standard detectors. General information. Product Sheet Detec on

Conductive Leakage detectors of the Leckstar range

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

Assembly and operating instructions Ice detector EM for open spaces and gutter heating

5000 INSTALLATION GUIDE

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

PLEASE READ THIS USER GUIDE CAREFULLY

CONTROL DEVICE SLIDETRONIC HD

RE46C190 3V Photo Smoke Detector IC

Microchip Technology overview of the RE46C180 Programmable Ionization Smoke Detector IC.

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

PolyGard 2-channel Gas Controller MGC-03

Wireless Interlink Smoke Alarm + 10 Year Life

LaserFOCUS VLF-250 Engineering Specification

Transcription:

ARGUS Smoke Detectors The next generation Safety and security electronics

2 Argus Smoke Detectors The next generation 10.2015 Safety and security electronics

Powerful new functions The new ARGUS Smoke Detectors have additional functions which have been specially optimised for different areas of application. All models have features such as pollution compensation, self-test of smoke detection, and the hush function. Pollution compensation Over the years, more and more foreign particles enter the smoke chamber, where they can impair the functioning of the detector. To prevent false alarms, the smoke detector automatically adjusts its alarm threshold accordingly. Hush function In some situations, a lot of smoke or dust will be expected. The push of a button switches the smoke detection function to hush mode for approximately 9 minutes, preventing any undesired alarm. Alarm memory The alarm memory indicates whether an alarm was triggered in your absence. With the alarms being saved for 24 hours, the function provides enough time to identify the cause and to react accordingly. Self-test of smoke detection Regular self-tests of the smoke detection function provide protection from an unnoticed failure. If a fault occurs during the test, the smoke detector will indicate it with both an acoustic and a visual signal. Low battery signal When the service life of the battery has been exceeded, the smoke detector issues a regular alarm tone at least 30 days before failure allowing a replacement in time. For the ARGUS Basic the alarm tone can be muted temporarily using the snooze function. The ARGUS Advanced and Radio feature a suppressed mode which can be activated 3x for 8 hours each. Radio networking The ARGUS Radio Smoke Detectors can be connected easily via interference-free radio frequency. If a smoke detector triggers an alarm it will forward the signal to all the other detectors in its network, which will then issue an alarm as well. This ensures that all persons in the apartment or house will be warned in good time. 1. Dust protection foil 2. Mounting base 3. 10-year battery 4. LED function button 5. Pollution compensation 6. Smoke chamber with protection grid 7. Dust protection grid Safety and security electronics 10.2015 The next generation Argus Smoke Detectors 3

ARGUS smoke detector ARGUS Smoke Detector Single FD BOSEC 9195 carton, polar white MTN5470-2119 Battery-powered smoke detector for early detection of smouldering fires and open fires with development of smoke indoors. The power supply is from a permanently installed lithium battery that has a service life of at least 10 years. The smoke detectors function according to the light scattering principle (Tyndall effect) and detect smoke particles in the ambient air. If there is an excessive concentration, they signal an alarm for the people present in the form of a loud alarm tone (approx. 85 db(a)) and LED signal. ARGUS smoke detectors with Q-Label! Q-Label tested according to vfdb Directive 14-01 for use according to DIN 14676. Surface-mounted installation with screws A dust-protection foil protects the smoke detector against drilling dust after installation. Functions: Function button: Activating functions, functional test LED and signal tones: Display of alarms, status and malfunctions Hush function: Manual increase in the response sensitivity (to avoid triggering an alarm when smoke or dust is expected to be created). Self-test of smoke detection: regular self-test of the smoke chamber with error display Pollution compensation: Control of the response threshold to avoid false alarms Battery failure signal: warning before end of battery life Functional principle: Scattered light (Tyndall effect) Detection type: smoke Response sensitivity: according to EN 14604 Power supply: Lithium battery Battery life: 10 years Device service life: 10 years Battery failure signal: min. 30 days, every 45 seconds Loudness of signalling device: 85 db(a) at 3 m distance Optical display: red LED Operating temperature: 0 C to +60 C Dimensions (with mounting base): 112x49 mm (Ø x H) Accessories: Sealing pin for ARGUS smoke detector MTN547000 Contents: Screws and plugs. Mounting base. Dust-protection foil. Language: English. French. Spanish. Portuguese. Dutch. Czech. Slovak. Hungarian. 4

ARGUS Smoke Detector Basic FD BOSEC 9195 carton, polar white MTN5471-2119 Battery-powered smoke detector for early detection of smouldering fires and open fires with development of smoke indoors. Wire networking by separate twin-core line (SELV) In networked smoke detectors, the smoke detector that detects smoke activates an alarm (local alarm) and forwards the alarm signal to all smoke detectors in the network which then also activate an alarm (remote alarm). The power supply is from a permanently installed lithium battery that has a service life of at least 10 years. The smoke detectors function according to the light scattering principle (Tyndall effect) and detect smoke particles in the ambient air. If there is an excessive concentration, they signal an alarm for the people present in the form of a loud alarm tone (approx. 85 db(a)) and LED signal. ARGUS smoke detectors with Q-Label! Q-Label tested according to vfdb Directive 14-01 for use according to DIN 14676. Surface-mounted installation with screws A dust-protection foil protects the smoke detector against drilling dust after installation. Functions: Function button: Activating functions, functional test LED and signal tones: Display of alarms, status and malfunctions Hush function: Manual increase in the response sensitivity (to avoid triggering an alarm when smoke or dust is expected to be created). Self-test of smoke detection: regular self-test of the smoke chamber with error display Pollution compensation: Control of the response threshold to avoid false alarms Battery failure signal: advance warning before the end of the battery life, can be suppressed manually for 8 hours Alarm memory: Storing a local alarm and display via LED Functional principle: Scattered light (Tyndall effect) Detection type: smoke Response sensitivity: according to EN 14604 Power supply: Lithium battery Battery life: 10 years Device service life: 10 years Battery failure signal: min. 30 days, every 45 seconds Loudness of signalling device: 85 db(a) at 3 m distance Optical display: red/yellow LED Networking: max. 40 smoke detectors Cable: e.g. J-Y(St)Y 2x2x0.8 mm Cable length total: max. 500 m Cable length between two smoke detectors: max. 25 m Operating temperature: 0 C to +60 C Dimensions (with mounting base): 112x49 mm (Ø x H) Accessories: Sealing pin for ARGUS smoke detector MTN547000 Note: It is also possible to network with existing ARGUS Connect smoke detectors by wire. With pipe cabling systems a gasket must be installed on site between the ceiling and the smoke detector. Contents: Screws and plugs. Mounting base. Dust-protection foil. Language: English. French. Spanish. Portuguese. Dutch. Czech. Slovak. Hungarian. 5

ARGUS Smoke Detector Duo FD BOSEC 9195 carton, polar white MTN5472-2119 Battery-powered smoke detector for early detection of smouldering fires and open fires with development of smoke indoors. Wire networking by separate twin-core line (SELV) In networked smoke detectors, the smoke detector that detects smoke activates an alarm (local alarm) and forwards the alarm signal to all smoke detectors in the network which then also activate an alarm (remote alarm). The power supply is from a permanently installed lithium battery that has a service life of at least 10 years. The smoke detectors function according to the light scattering principle (Tyndall effect) and detect smoke particles in the ambient air. If there is an excessive concentration, they signal an alarm for the people present in the form of a loud alarm tone (approx. 85 db(a)) and LED signal. ARGUS smoke detectors with Q-Label! Q-Label tested according to vfdb Directive 14-01 for use according to DIN 14676. Surface-mounted installation with screws A dust-protection foil protects the smoke detector against drilling dust after installation. Functions: Function button: Activating functions, functional test LED and signal tones: Display of alarms, status and malfunctions Hush function: Manual increase in the response sensitivity (to avoid triggering an alarm when smoke or dust is expected to be created). Self-test of smoke detection: regular self-test of the smoke chamber with error display Pollution compensation: Control of the response threshold to avoid false alarms Battery failure signal: advance warning before the end of the battery life, is initially suppressed automatically for 3x8 hours Alarm memory: Storing a local alarm and display via LED Heat detection: Fire detection by increase in heat (in hush mode) Functional principle: Scattered light (Tyndall effect) Detection type: Smoke or heat Response sensitivity: according to EN 14604 Power supply: Lithium battery Battery life: 10 years Device service life: 10 years Battery failure signal: min. 30 days, every 45 seconds Loudness of signalling device: 85 db(a) at 3 m distance Optical display: red/yellow LED Networking: max. 40 smoke detectors Cable: e.g. J-Y(St)Y 2x2x0.8 mm Cable length total: max. 500 m Cable length between two smoke detectors: max. 25 m Operating temperature: 0 C to +60 C Dimensions (with mounting base): 112x49 mm (Ø x H) Accessories: Sealing pin for ARGUS smoke detector MTN547000 Note: It is also possible to network with existing ARGUS Connect smoke detectors by wire. With pipe cabling systems a gasket must be installed on site between the ceiling and the smoke detector. Contents: Screws and plugs. Mounting base. Dust-protection foil. Language: English. French. Spanish. Portuguese. Dutch. Czech. Slovak. Hungarian. 6

ARGUS Smoke Detector RF Duo FD BOSEC 9195 carton, polar white carton, aluminium MTN5480-1119 MTN5480-1160 Battery-powered radio smoke detector for early detection of smouldering fires and open fires with development of smoke indoors. Radio networking with integrated radio module Wire networking by separate twin-core line (SELV) In networked smoke detectors, the smoke detector that detects smoke activates an alarm (local alarm) and forwards the alarm signal to all smoke detectors in the network which then also activate an alarm (remote alarm). The power supply is from a permanently installed lithium battery that has a service life of at least 10 years. The smoke detectors function according to the light scattering principle (Tyndall effect) and detect smoke particles in the ambient air. If there is an excessive concentration, they signal an alarm for the people present in the form of a loud alarm tone (approx. 85 db(a)) and LED signal. ARGUS smoke detectors with Q-Label! Q-Label tested according to vfdb Directive 14-01 for use according to DIN 14676. Surface-mounted installation with screws A dust-protection foil protects the smoke detector against drilling dust after installation. Functions: Function button: Activating functions, functional test LED and signal tones: Display of alarms, status and malfunctions Hush function: Manual increase in the response sensitivity (to avoid triggering an alarm when smoke or dust is expected to be created). Self-test of smoke detection: regular self-test of the smoke chamber with error display Pollution compensation: Control of the response threshold to avoid false alarms Battery failure signal: advance warning before the end of the battery life, is initially suppressed automatically for 3x8 hours Alarm memory: Storing a local alarm and display via LED Functional principle: Scattered light (Tyndall effect) Detection type: Smoke or heat Response sensitivity: according to EN 14604 Power supply: Lithium battery Battery life: 10 years Device service life: 10 years Battery failure signal: min. 30 days, every 45 seconds Loudness of signalling device: 85 db(a) at 3 m distance Optical display: red/yellow LED Networking: max. 40 smoke detectors Cable: e.g. J-Y(St)Y 2x2x0.8 mm Cable length total: max. 500 m Cable length between two smoke detectors: max. 25 m Radio frequency: 868 MHz Radio range: max. 30 m indoors, max. 100 m outdoors Radio operating elements: DIP switch for addressing/grouping Operating temperature: 0 C to +60 C Dimensions (with mounting base): 112x49 mm (Ø x H) Accessories: Sealing pin for ARGUS smoke detector MTN547000 System relay FM for ARGUS Smoke Detectors MTN5493-3190 Note: It is also possible to network with existing ARGUS Connect smoke detectors wirelessly or by wire. With pipe cabling systems a gasket must be installed on site between the ceiling and the smoke detector. Contents: Screws and plugs. Mounting base. Dust-protection foil. Language: English. French. Spanish. Portuguese. Dutch. Czech. Slovak. Hungarian. 7

ARGUS Accessories smoke detector, NF version for France Sealing pin for ARGUS smoke detector black MTN547000 For direct display of smoke detector manipulation. When the smoke detector is removed, a sealing pin inserted into the mounting base breaks. To be completed with: ARGUS Smoke Detector Single MTN5470-2119 ARGUS Smoke Detector Basic MTN5471-2119 ARGUS Smoke Detector Duo MTN5472-2119 ARGUS Smoke Detector RF Duo MTN5480-1119/-1160 ARGUS smoke detector Connect MTN548020/61 ARGUS smoke detector Connect 230 V MTN548520/61 ARGUS smoke detector 230 V MTN547520/61 ARGUS smoke detector Basic MTN547020 ARGUS smoke detector Basic Longlife MTN547120 Contents: 1 PU = 50 sealing pins System relay FM for ARGUS Smoke Detectors MTN5493-3190 The relay is connected to ARGUS smoke detectors and thus acts to forward a smoke alarm to external alarm devices. Depending on the smoke detector, this must be connected either via a separate core in the 230V mains network or per radio. The relay is powered with mains voltage and has a floating make contact for the external alarm device. You can connect for example the following alarm devices: horns, warning lights, vibration cushions for the deaf, or KNX binary inputs. These devices must have their own power supply. Suitable for installation in a size 60 installation box. Supply voltage: AC 230 V Contact type: Make contact, floating (SELV) Switching current: AC 230 V, µ 4 A / DC 24 V, µ 2 A Connecting terminals: for 2.5 mm 2 Dimensions: 44 x 50 x 34 mm (WxHxD) To be completed with: ARGUS Smoke Detector RF Duo MTN5480-1119/-1160 ARGUS smoke detector Connect MTN548020/61 ARGUS smoke detector Connect 230 V MTN548520/61 ARGUS smoke detector 230 V MTN547520/61 8

Index MTN5470-2119 4 MTN5471-2119 5 MTN5472-2119 6 MTN5480-1119 7 MTN5480-1160 7 MTN5493-3190 8 MTN547000 8 9