evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

Similar documents
EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Evolution Analogue Addressable Fire System

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

SOUNDER CONTROL MODULE SCM-AS4

Instruction Manual EVA-STB-RL

Touch Screen 1 loop Addressable Fire Alarm Panel

NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number

CONTENTS NBM-06 Bell (6") Page 1

Evolution Product Range

Instruction Manual EVA-PY

Instruction Manual EVA-DPH

Instruction Manual EVA-S6 Base

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Series 65 Product Guide MAN 3036

A Guide To BS Understanding the selection, spacing and siting of detectors

LPC3BSP65 & LPC3BDP65

EVA-SCM-SCI Sounder Control Module

LPCMPIRM65 & LPCMPIRDSI65

The EN54 Part 2 & 4 Fire System

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Intelligent addressable fire alarm control panel

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Fire Alarm Control Panel. System Maintenance and Log Book

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

2000W Ceramic Wall Heater with LED Display

LevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Analogue addressable devices

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Fire detection and alarm

360º Surface Mount Ceiling PIR Light Controller

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

OH720, OP720, HI720, HI722

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

IFD-E Flame Detector User Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Table of Contents. 1. Mounting Tips... 2

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - HW

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Integrated PIR detectors

IFD-E Flame Detector User Manual

optical detector multisensor detector heat detector mounting bases product guide

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Multifunctional Gate Box MGB. More than safety.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

MURELLE EV HE 25/55-30/55

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

SERIES 65 ENGINEERING PRODUCT GUIDE

Consultant Specification AGILE Wireless Fire Detection System

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Ceiling Microwave presence/absence detector 12-24V AC/DC

PA ma Loop Powered Level Preamplifier

HW3 Handwash Installation and Operating Instructions

RadioLINK Alarm Base. Instructions. Model: Ei168RC

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Type approval testing of miscellaneous smoke and heat detectors for marine applications

, ,

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

PREMIER PLATINUM INFRARED GAS SENSOR

DD205RF/TX Detector Installation Sheet

FIRE ALARM CONTROL PANEL FVC01-08

INSTRUCTION MANUAL (English version) Water still

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Heat Sensor Cable Alarm Units DT650L / DT950L

Laser Distance Sensor Type M Analog-Output

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

2400W Ceramic Tower Heater

Warnings, Safety Information and Guidance

MWS3 Ceiling Mount Microwave Occupancy Detector

Installation and Operation Manual

Euromixer Thermostatic Mixing Valves

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

Air Purification System. Instruction Book CLI-AP20

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

DT1101A / DT1102A / DO110xA Automatic fire detectors

Combi Eco Elite Range. User s Guide and Important Warranty Information

The EN54 Part 2, 4 and 13 Fire System

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Operating instructions for the radio heat detector GS412

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Tri-level Control HF Sensor

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Transcription:

Document No: Date: SEPT 2015 EV-H ANALOGUE ADDRESSABLE LPCB REF: 041h/01&02 and 842c/03&04 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2008 Hipley Street, Old Woking, Surrey, England, GU22 9LQ. UK Tel: +44 (0) 1483 769555 Fax: +44 (0) 1483 756686 Web Site: www.nittan.co.uk E-mail: sales@nittan.co.uk

Ref No: 1 of 6 05... The EV-H advanced analogue addressable heat sensor forms part of a brand new range of analogue addressable fire sensors from Nittan UK called. The EV-H together with the EV-PH, EV-P and EV-DP are all elegantly designed, low profile fire sensors which are aesthetically pleasing, thus enabling them to blend unobtrusively into modern working environments. The analogue addressable range all feature the very latest technological advancements such as ASIC design, increasing reliability and performance.... - BRINGING STYLE INTO FIRE DETECTION SYSTEMS Changes are subject to DCRN. Manual: EV-H Manual 000018

Ref No: 2 of 6 05 CONTENTS:- Section 1 - Introduction - Page 2 Section 2 - Sensor Models - Page 2 Section 3 - Base Models - Page 2 Section 4 - Installation - Page 3 Section 5 - Maintenance & Cleaning - Page 3 Section 6 - Specifications - Page 4 Section 7 - Environmental Parameters:- - Page 4 - Temperature - Page 4 - Humidity - Page 4 Section 8 - EMC - Page 4 Section 9 - Address Setting - Page 5 Section 10 - Connections - Page 6 Section 11 - Dimensions - Page 6 Section 12 - Heat Response Graph - Page 7 Section 1 - INTRODUCTION The EV-H is an attractively-styled, low profile heat sensor for use with Nittan '' protocol control panels. EV-H features: * Low profile, stylish appearance * Soft addressing * Low monitoring current * Supplied with protective dust cover * Patented OMNIVIEW TM 360 o LED fire alarm indicator * Remote indicator output * 'Base Control' auxiliary output * Compatible with UB-6-EV and STB-4SE-EV bases * Non-polarised terminals * Rate of rise operation for high sensitivity model EV-H-A1R * Static operation for high temperature model EV-H-CS * Room temperature information can be separately taken. Section 2 - SENSOR MODELS The EV-H heat sensor has two terminals for connection onto the two wire loop. The remaining terminals provide a switched current sink function which operates when the detector goes into alarm condition, suitable for the operation of an auxiliary function such as a remote indicator. Terminal 3 (RIL) is limited to 3mA. Terminal 2 (Base Control) is not current limited. Section 3 - BASE MODELS A variety of bases are available for use with the EV-H detectors. It is important to use the correct base for each application. The available base models are: i) UB-4 base: For standard use with EV-H series heat detector when auxiliary output not used. ii) UB-6-EV base: For standard use with EV-H series heat detector when auxiliary output not used. iii) STB-4SE-EV base: Similar to UB-6-EV base, except deeper.

Ref No: 3 of 6 05 Section 4 - INSTALLATION In normal use, the EV-H heat sensor will be installed at ceiling level. Pass the field wiring through the cable hole in the centre and from the rear of the base. Offer up and affix the base to the ceiling or conduit fitting with screws via the base mounting holes. Connect the field wiring to the base terminals, as detailed on page 6 making sure the wiring does not obstruct fitting of the sensor head. Fit the heat sensor head by inserting it into the base and turning clockwise until the notch in the sensor's rim aligns with base locking screw. The OMNIVIEW TM 360 o LED alarm indicator permits visibilty from any angle. Note: The address must be set before the sensor is fitted into place. Fit the plastic dust cover supplied over the sensor to keep out dust etc, until the system is commissioned. If the dust cover is not fitted and the environment is slightly dusty, such as when building work is being completed, for example, problems of false alarms are likely to occur unless cleaning of the sensor is undertaken. At commissioning, the dust cover should be removed and discarded. Routine Inspection i) Ensure the sensor head is secure and undamaged. ii) Check the heat entry apertures are in no way obstructed. iii) Ensure that the surface of the sensor's outer cover is clean. If there are deposits due to the presence of oil vapour, dust etc, then the sensor should be cleaned in accordance with the cleaning instructions detailed later in this manual. It may be advisable to ensure that such cleaning is conducted regularly in future. iv) Ensure that no equipment which may generate excessive heat has been installed in the vicinity of the sensor since the last routine inspection. If such equipment has been installed, then you should notify the Fire Safety Officer or other competent authority that its presence may cause false alarms. Operational Test The purpose of the Operational Test is to confirm the sensor s correct operation in response to a heat condition. NOTE: THE PLASTIC DUST COVER MUST BE RE- MOVED FROM THE SENSOR IN ORDER FOR THE SENSOR TO FUNCTION CORRECTLY. Note: When carrying out site testing of Analogue Addressable Evolution sensors, the CIE shall be set to test mode prior to beginning the tests. Section 5 - MAINTENANCE AND CLEANING Maintenance: The EV-H sensor is a high quality product engineered for reliability. In order to obtain optimum performance. periodic maintenance is required. If proper preventative maintenance is not carried out, there is a likelihood of malfunction, including false alarms. Servicing: Servicing of the system should be carried out in accordance with the requirements of BS 5839 Part 1, Fire Detection and Alarm Systems for Buildings: Code of Practice for System Design, Installation and Servicing. The maintenance procedures described below, should be conducted with the following frequency: One month after installation: Every 6 months: Every 12 months: Routine Inspection and every 3 months thereafter. Operational Test. Functional Test and Cleaning. All above frequencies of maintenance are dependent on ambient conditions. i) Take any necessary precautions at the control panel to limit the sounding of the alarm sounders/bells and any fire service summoning device. ii) Test the sensor with heat from a warm air gun designed for heat sensor testing (e.g. 'No Climb - Solo' heat sensor tester). Check that the sensor gives an alarm condition within 10-20 seconds depending upon the sensor grade and the applied air temperature. Check that the LED indicator on the sensor illuminates. N.B. Hot air blowers sold for paint stripping, soldering pipes etc. generate sufficient heat to damage the sensor and should not be used for testing heat sensors. iii) After the sensor has given the alarm condition, reset the sensor from the control panel. It may be necessary to allow a short time to elapse before resetting the sensor, to allow any residual heat from the test to disperse. iv) Before proceeding to the next sensor, ensure that the sensor just tested does not re-operate due to the presence of residual heat.

Ref No: 4 of 6 05 Functional Tests: The functional test checks the sensors operation. These sensors may be returned to our factory for Functional Testing. Section 7 - ENVIRONMENTAL PARAMETERS Temperature Considerations: Over the range from -10 o C to +55 o C Cleaning: Note: The sensor head should NOT be disassembled. i) Carefully remove the heat sensor from its base. ii) Use a soft, lint-free cloth, moistened with alcohol for sticky deposits, to clean the plastic cover. iii) Using a soft bristle brush (e.g. an artist's paintbrush) carefully brush between the vanes and thermistor in a linear motion away from the apertures on the plastic case. iv) Ensure that no debris is left on or around the thermistor once cleaning is complete. v) If the unit needs further cleaning or is damaged or corroded, please return the complete sensor to Nittan UK. for service. Section 6 - SPECIFICATIONS Model Reference: - EV-H-A1R EV-H-CS Humidity: Relative Humidity of up to 95%, measured at 50 O C, non condensing. Section 8 - EMC Installation The installation shall be in accordance with the regulations either of the approval body for an approved system, or otherwise, to the national code of practice/ regulations for the installation of the fire alarm system, e.g. BS 5839 part 1. Electromagnetic Compatibility (EMC) On a site where there is an unusually high level of potential electrical interference, e.g. where heavy currents are being switched or where high levels of R.F. are prevalent, care then must be taken in the type and routing of cables. Particular care should be given to the separation of zone wiring from the cable carrying the interference. Computer Reference: - EV-H-A1R - F15N82200 EV-H-CS - F15N82201 Sensitivity: - EV-H-A1R: Rate of rise with 62 o C fixed level. EV-H-CS: Static 83 o C. Section 9 - ADDRESS SETTING Use EV-AD2 Programmer for setting the address of all devices prior to installation. Sensor Type: Thermistor of low thermal mass Operating Current: - 200 amps fire alarm (LED on) 5.2mA Standard: - EN54 Part 5:2000 Mass: - 118g (excluding base) Charging Time: - 20 seconds Ambient Temperature Range: - -10 o C to +55 o C (A1R) -10 o C to +80 o C (CS) IP Rating: - 42

Section 10 - CONNECTIONS RIL must be LED type + RIL Max. current through 3 = 3mA @ 24V d.c. Ref No: 5 of 6 05 Base 3 Control 3 2 2 1+ 6 1 6 _ UB-6-EV base STB-4SE-EV base Auxiliary terminal RIL current limited to 3mA. Base control is not current limited as the auxiliary equipment provides the limiting. If the +ve supply for the auxiliary equipment is taken from the EV loop, care must be taken to not cause corruption of the EV protocol by excessive current draw. Section 11 - DIMENSIONS 15mm 43mm 104mm

Ref No: 6 of 6 05 Section 12 - HEAT RESPONSE GRAPH EV-H Rate of Rise Response (degree C/Min) 100 20 10 5 3 90 80 70 CS 1deg/m 60 3deg/m 5deg/m 50 10deg/m 1 A1R 20deg/m 40 L Limit A1 U Limit A1 30 L Limit Others U Limit Others 20 10 0 0 5 10 15 20 25 30 35 40 45 50 Response Time (Minutes)