HIGH EXPANSION INTUMESCENT SEALANT Prevents the spread of smoke and fire

Similar documents
FIRE TUBE Fire protection for process pipes and structural steel

GLUE Fire resistant adhesive for FIREPRO fire protection systems

FIREPRO SoftSeal System

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

MECHANICAL FIRE STOPPING SOLUTIONS

Fire Protection. Intumescent fire and smoke seals for door assemblies

EUROPEAN TECHNICAL ASSESSMENT

ELECTRICAL FIRE STOPPING SOLUTIONS

An introduction to Part L insulating pipes and ducts

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

EUROPEAN TECHNICAL ASSESSMENT

BlazeMaster Fire Sprinkler Systems

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

THE HOME OF REACTIVE PROTECTION SYSTEMS

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire resistance test on fire collars protecting a concrete slab penetrated by services

FireFighter Antifreeze

An introduction to Part L Insulating pipes and ducts

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

EUROSPRINT NEXT TECHNICAL DATA SHEET

FireFighter Antifreeze

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

ALTURA 619 EXTRA TECHNICAL SHEET

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

Roadware MatchCrete Clear. Standard Product Data Sheet

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

PRODUCT SPECIFICATION DRAWING Hydroflame Pro Series Sleeves

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Regulatory Reform (Fire Safety) Order 2005

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

Loss Prevention Standards

RG1,5SA Self Adhesive

WORLDWIDE CABLE EXPERTS

30 Minute Firedoor. 30 minute firedoor

Arma-Chek D THE DURABLE PRE-COVERED ARMAFLEX SYSTEM TO WITHSTAND MECHANICAL STRESS

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

Product Data Sheet. Astro Strip

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

FIRESTOP INSPECTION. Dr. Selina LIN. Technical Manager August 01, FS Inspection 1

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

F O C U S D O O R C L O S E R S

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

Fire Collars for Floor Wastes Understanding BCA Compliance Options

Two (2) Side Rail Cable Tray

SOLDERING EQUIPMENT AND ACCESSORIES CHEMICAL PRODUCTS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Protective & Marine Coatings Europe, Middle East, Africa & India

CHAPTER 8 CHIMNEYS AND VENTS

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Pot Belly Black. Overview. Suitable Surfaces

Shared Services Partnership

Dyna-Form Air. Alternating Pressure Relief Overlay System

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

EN Storage of gas cylinder

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

CERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:

Abrasion Resistance of Fluoropolymer and polyester Coatings

Roofing Adhesive SARNACOL 2172 Spray

INSET LIVE FUEL EFFECT GAS FIRE

An Overview of Extinguishing Systems for Computer Equipment

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

Intumescent Fire Seals

Rytons Boiler, Stove and Fire Ventilators

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

B-LINE SERIES. Product brochure. Firestop

Life Safety and Fire Resistant Glazing Systems

Easy-action Door Closer DORMA TS83

Civil engineering Fibertex Geotextiles

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

This place covers: Devices, apparatus and methods to prevent fires from happening, and to fight or contain active fires.

Visqueen Vapour Control Tapes


Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

UK Direction BS7671 BS 8492 BS /01/2018

PROLAQ. New product for Cleaning solution for water & solvent based paints, varnishes & inks MAKING GREEN WORK.

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

Transcription:

HIGH EXPANSION INTUMESCENT SEALANT Prevents the spread of smoke and fire

FIREPRO HIGH EXPANSION INTUMESCENT SEALANT FIREPRO High Expansion Intumescent Sealant is an easy to apply water based acrylic emulsion sealant containing graphite. It reacts to temperatures above 135 C which is used to reinstate the Integrity and insulation rating of compartment walls and floors where penetrated by combustible and non-combustible materials. 2

Advantages Simple solution for sealing cables, combustible pipes and metal pipes with combustible insulation Suitable for both walls and floors Compatible with cpvc pipes Tested in multiple substrates Description ROCKWOOL FIREPRO High Expansion Intumescent Sealant is water based acrylic sealant containing graphite. In the event of a fire the active components provide a high volume expansion and pressure seal closing off the void left by combustible materials. ROCKWOOL FIREPRO High Expansion Intumescent Sealant is supplied in 310ml cartridges. Applications FIREPRO High expansion Intumescent Sealant is comprehensively tested for a wide range of applications which include: Combustible pipes Cables (single cables or bunches of cables) Metal pipes insulated with combustible insulation Other permanent services 3

Performance Standards and approvals FIREPRO High Expansion Intumescent Sealant has been tested to BS EN 1366-3: 2009 and BS EN 1366-4: 2006 +A1:2010 and classified to EN 13501-2, providing up to 4 hours fire protection in joints up to 30mm. FirePro High Expansion Intumescent Sealant has been CE marked against ETAG026-2. FBC System Compatible indicates that this product has been tested, and is monitored on an ongoing basis, to assure its chemical compatibility with FlowGuard Gold, BlazeMaster and Corzan pipe and fittings. FBC, FlowGuard Gold, BlazeMaster and Corzan are licensed trademarks of The Lubrizol Corporation or its affiliates. FIREPRO High Expansion Intumescent Sealant is third party accredited through IFC and Certifire. This product has been authorised for use in LUL surface and sub-surface premises when installed in accordance with this datasheet - please refer to the LUL Approved Product Register website www.lu-apr.co.uk for specific details. LUL Ref. 2454. Table 1 2 hour dry wall (min. 120mm thick) Table 2 Wall with Single 50mm FIREPRO Ablative Coated Batt Service Penetration Diameter (Ø) Wall Thickness Annular Space (mm) Depth (mm) Classification Cables 21 N/A 20 25Ф EI 120 U/C PVC Pipes ⱡ 40 3 10 25Ф EI 120 U/C PVC Pipes ᴪⱡ 125 7.4 16 25Ф EI 120 U/C HDPE 63 7.2 20 25Ф EI 120 U/C HDPE 90 9.2 12.5 25Ф EI 120 U/C ABS 90 6 12.5 25Ф EI 120 U/C Copper / Steel Pipe with Armaflex 32mm CS Copper / Steel Pipes with Armaflex 16mm CS Service Penetration 60 0.8-14.2 20 25Ф E 120/EI 90 U/C 15 0.8-7 15 25Ф EI 120 U/C Diameter (Ø) Wall Thickness Annular Space (mm) Depth (mm) Classification PVC Pipes ⱡ 125 7.4 20 50 EI 30 U/C Multi Layer Composite Pipes 110 10 20 50 E45 EI30 U/C 500mm perforated cable tray* N/A N/A 20 50 EI 30 Medium Cables* 47 N/A 20 50 EI 45 Table 3 Masonry Wall (min. 150mm thick) with Double 50mm FIREPRO Ablative Coated Batt Service Penetration Diameter (Ø) Wall Thickness Annular Space (mm) Depth (mm) Classification PVC Pipes ⱡ 125 7.4 20 25Ф EI 120 U/C Multi Layer Composite Pipes 110 10 20 25Ф EI 120 U/C 500mm perforated cable tray* N/A N/A 20 25Ф EI 120 Medium Cables* 47 N/A 20 25Ф EI 120 4

Table 4 Rigid Floor (min. 150mm thick) Service Penetration Diameter (Ø) Wall Thickness Annular Space (mm) Depth (mm) Electrical Cables ɸ 80 N/A N/A 25 E120 Non Sheathed Electrical Cables ɸ 24 N/A N/A 25 E180 Telecom Cables bundled ɸ up to 21 N/A N/A 25 E180 Copper / Steel Pipe with Armaflex 32mm CS ɸ Copper / Steel Pipe with Armaflex 16mm CS ɸ Classification 159 14.2 20 25 EI 120 U/C 41 14.2 20 25 E240/ EI 60 U/C PP Pipes ɸⱡ 110 10.7 20 25Ф EI 120 U/C PP Pipes ɸⱡ 50 2.1 20 25Ф EI 240 U/C PE Pipe ɸⱡ 40 4.1 20 25Ф EI 240 U/C PE Pipe ɸⱡ 125 11.4 20 25Ф EI 90 U/C PVC Pipe ɸⱡ 40 2 20 25Ф EI 240 U/C PVC Pipe ɸⱡ 114 8.1 20 25Ф EI 120 U/C Table 5 Rigid Floor (min. 150mm thick) with Double 50mm FIREPRO Ablative Coated Batt Service Penetration Diameter (Ø) Wall Thickness Annular Space (mm) Depth (mm) Classification PVC Pipe ⱡ 50 7.4 20 25Ф EI 120 U/C PVC Pipe ⱡ 125 7.4 20 25Ф EI 120 U/C Multi Layer Composite Pipes 110 10 20 25Ф E120/EI 60 U/C 500mm perforated cable tray* N/A N/A 20 25Ф EI 120 Medium Cables* 47 N/A 20 25Ф EI 120 Multi Service as follows (installed centrally in aperture) PE Pipe ɸⱡ 125 7.6 N/A 25Ф 60 Pipe with Cables ɸ 21 N/A N/A 25Ф E120/EI 90 U/C E120/EI 90 U/C Table 6 Linear Joints Service Penetration Diameter (Ø) Wall Thickness Annular Space (mm) Depth (mm) Classification pvc Pipe ϖ 50 7.4 20 25Ф EI 120 U/C Key to tables ⱡ = See assessment for other pipe sizes and wall thicknesses within field of application. *C= All cables coated with 2mm DFT (Dry Film Thickness) of Firepro RW = Rigid Wall ACB = Ablative Coated Batt CS = Continuous Sustained Ф = Applied to both faces of seal = Applied to upper face only ᴪ = Use RW4 as backing material, minimum 30mm deep. ɸ = Use RWA45 as backing material, minimum 100mm deep. ϖ = Use PE backing rod 5

Technical information Product information Property Form Cartridge size Curing system Description Ready to use thixotropic paste 310ml Specific gravity 1.5 Extrusion rate SAG Open time Tack free time Curing time Shore (A) hardness 50 Water based 350g/min 3min 30mins 60mins 3 to 5 days Solids >80% Application temperature range +4 C to +35 C Service temperature range -15 C to 70 C Shelf life Up to 12 months when stored in unopened cartridges under cool, dry conditions. Avoid Extreme Temperatures Installation All surfaces must be clean and sound, free from dirt, grease and other contamination. Prepare joint by cleaning as previously detailed and insert backer if required. Cut nozzle to the desired angle and gun firmly into the joint to give a good solid fill to the required depth. Strike off the sealant flush with the joint sides within five minutes of application, before surface skinning occurs. A small amount of shrinkage will occur on curing. If a flush finish is required, fill the joint slightly proud of the surface to allow for shrinkage. Important information The sealant is not intended for application on bituminous substrates or substrates that can exude certain oils and plasticizers or solvents. The sealant is not recommended for submerged joints or areas exposed to high abrasion. The sealant is not suitable for food contact or medical applications. 6

Specification clauses FirePro High Expansion Intumescent Sealant is associated with the following NBS clauses: E40: Designed joints in in-situ concrete 530 Sealant F30: Accessories/sundry items for brick/block/stone walling - 610 Movement joints with sealants L10: Windows/rooflights/screens/louvres 790 Fire resisting frames L20: Doors/shutters/hatches 820 Sealant joints P12: Fire stopping systems 395 Sealant-One part fire resistance acrylic Disclaimers This product should only be utilised for applications as outlined in the relevant ROCKWOOL product datasheet and in accordance with the relevant ROCKWOOL Fire Resistance Testing. Additionally, the product must be installed in accordance with the current ROCKWOOL guidelines. For further information please visit www.rockwool.co.uk or contact our Technical Solutions Team on 01656 868490. Supporting information For further information relating to any aspect of the FirePro range, please refer to the applicable ROCKWOOL standard details at www.rockwool.co.uk or contact the ROCKWOOL technical solution team on 01656 868490 or technical.solutions@rockwool.co.uk. 7

Sustainability As an environmentally conscious company, ROCKWOOL promotes the sustainable production and use of insulation and is committed to a continuous process of environmental improvement. All ROCKWOOL products provide outstanding thermal protection as well as four added benefits: Fire resistance Acoustic comfort Sustainable materials Durability Environment Made from a renewable and plentiful naturally occuring resource, ROCKWOOL insulation saves fuel costs and energy in use and relies on trapped air for its thermal properties. ROCKWOOL insulation does not contain (and has never contained) gases that have ozone depletion potential (ODP) or global warming potential (GWP). ROCKWOOL is approximately 97% recyclable. For waste ROCKWOOL material that may be generated during installation or at end of life, we are happy to discuss the individual requirements of contractors and users considering returning these materials to our factory for recycling. Health & Safety The safety of ROCKWOOL stone wool is confirmed by current UK and Republic of Ireland health & safety regulations and EU directive 97/69/EC:ROCKWOOL fibres are not classified as a possible human carcinogen. A Material Safety Data Sheet is available and can be downloaded from www.rockwool.co.uk to assist in the preparation of risk assessments, as required by the Control of Substances Hazardous to Health Regulations (COSHH). Interested? For further information, contact the Technical Solutions Team on 01656 868490 or email technical.solutions@rockwool.co.uk Visit www.rockwool.co.uk to view our complete range of products and services. Copyright ROCKWOOL April 2018. 8

Notes 9