MANUAL. Type ETO2 Controller for ice and snow melting. Warmup Inc. The world s best-selling electric floor heating brand

Similar documents
Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

ETO 2 - Controller for ice and snow melting

57654C 02/11 (MBC) 2011 OJ Electronics A/S. Type ETR2 Ice and snow melting

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

IDEAL E-NERGY Thermostat Touch type User Manual

Type UDG, UCG, UTN, USG

MCD User Manual

/18 (JRK) MTD User Manual OJ Electronics A/S

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Programmable Interactive User Manual

USER MANUAL Comfort System4 TM

User Guide ems25plus. Page 1. Normal operation. Product interface

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

settings and adjustments

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

MTC User Manual

Roth Touchline. German quality since Quick and easy user manual 1/10

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Follett Performance Plus

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

Touch Thermostat Interactive User Manual

Installation Settings Guide

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

WLM2 WLTA WLTD WLTP WLCT2

Installer Manual KNX Touchscreen Thermostat

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Z100 Pioneer 2 Smart Thermostat Operating and Installation Manual

Sensor Control Panel

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

INSTRUCTION MANUAL. Matos Refrigerators / Freezers

Roth Touchline. German quality since User manual quick and easy guide 1/10

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Dryer Master DM510 Commissioning Guide

PARAGON Commercial Refrigeration Controls

SSV-DC user manual. Phason

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series

Pioneer Z100 Smart Thermostat Operating and Installation Manual

User's Guide. CTS6000 control panel

Portable Dryer Touch Screen Controls

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

OPERATING INSTRUCTIONS

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

intelligent controls for hydronic floor heating

TEMPERATURE CONTROLLER (STANDARD MODEL)

Installation and Operating Manual

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

RC-2000 Thermostat Installation Instructions

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Model: Edge-HC. 1 edge-hc

ST Wiring diagram. Product description. Four-stage controller. Order number

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

ComfortSense 7500 Thermostat. User Guide

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Safety & Installation Instructions

Accent User. Version. Rheem. PO Box 146, ABN:

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Technical Seminar HL-BD82S. Electric Built-In Oven. Panasonic Canada 2013

A WORLD OF COMFORT. Quick start guide. following control units and mounting parts: Control units EasyStart Remote, 12 /24 V

- Data Brochure Snow Detector & Melting Control 665

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Product Instructions. Basic Digital Snow Melt Control II. Applications. Features. Specifications

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Model 60200FR Gas Primary Control Data Sheet

Operating instructions V-ZUG-Home

Oakton TEMP 9500 Advanced Multiparameter Controller

Model: Available in: Sapphire Black and Glacier White. 1 Series

SOLO User Guide. Description. Installation. Programmable Dual Voltage Thermostat 240 V (120 V)

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

Quick Guide for SmartShaker 2

Safety & Installation Instructions

Keep your home snow and ice free with. WARMUP Outdoor Heating Solutions. From the world s best-selling electric floor heating brand

ComfortSense 7500 Commercial Thermostat. User Guide

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

B-40/B-41 Modulating Temperature Controller

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

Manual Vane Anemometer PCE-VA 20

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

NVENT NUHEAT HOME THERMOSTAT Operating Manual

Pioneer Z100 Smart Thermostat Operating and Installation Manual

Product Manual SZ1009

Vokèra OpenTherm 711 without external sensor connected

Memcom Emergency Telephone

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

CT224 Setup Tutorial

918TS Manual 1/26/09-1 -

Vokèra OpenTherm 711 with external sensor connected

Manitex Operation Manual

On initial power up the thermostat will guide you through set up procedure for the following:

Transcription:

MANUAL Type ETO2 Controller for ice and snow melting The world s best-selling electric floor heating brand @2011 Warmup Inc. G R E E N C O M F O R T Maximum comfort with low energy consumption

CONTENTS Glossary............................................. Page 2 Introduction........................................... Page 3 Startup............................................. Page 4 Operation............................................ Page 6 Main menu........................................... Page 6 Display texts........................................... Page 7 Application info......................................... Page 8 Settings............................................. Page 9 Offset calibration........................................ Page 13 Factory settings......................................... Page 14 Troubleshooting......................................... Page 15 Illustrations........................................... Page 69 GLOSSARY Zone 1, 2: Encoder button: ETOG-55: ETOR-55: ETF-744/99: Y/ : Afterrun: 2 Independent heating zones in which ice and snow can be melted. Button which can be turned or pressed to easily configure the settings. Ground sensor for detecting moisture and temperature. Gutter sensor for detecting moisture. Outdoor sensor for detecting temperature. Advanced 2-stage control of electric heating systems. The heat provided by the system, for a specified length of time, after the moisture/temperature signal has been eliminated by a heating cycle.

INTRODUCTION Type ETO2 is an electronic controller for fully automatic, economical ice and snow melting on outdoor areas and in gutters. Ice forms due to a combination of low temperature and moisture. ETO2 detects both temperature and moisture and the heating system will only be activated if a possibility of snow or ice is indicated by both parameters. An easily operated encoder button and backlit graphic display ensure quick and easy configuration and simple indication of temperature, status, etc. ETO2 is suitable for controlling electric heating cables in 1 or 2 zones. It also features advanced two-stage output control for economic operation. In hydronic mode, the supply sensor maintains the required supply water temperature while the system is active. When heat is demanded, the circulation pump is activated and the valve is opened 20% for 1 minute to let the system stabilise. The main pump is then activated. When there is no need for melting, the system activates the circulation pump for 1 minute every 15 minutes to check whether the return water temperature has dropped below the required idle temp. If this is the case, the system fully activates to increase the return water temperature to the required level. 3

STARTUP SELECT SCALE: CELCIUS FAHRENHEIT When ETO2 is switched on for the first time, Celsius or Fahrenheit must be selected. Turn the encoder button until the required temperature scale is highlighted. Then OK the selection by pressing the encoder button. SENSOR 1: ETOG ETOR SENSOR 2: OFF ETOG ETOR SENSOR 1 is shown on the display, allowing the type of sensor connected for input 1 to be selected: ETOG : Ground sensor ETOR : Gutter sensor + outdoor sensor Then OK the selection by pressing the encoder button. SENSOR 2 is then shown on the display, allowing the type of sensor connected for input 2 to be selected. If none sensor is connected for input 2, OFF must be selected. 4

OUTDOOR SENSOR: OFF ETF Select if outdoor sensor ETF is connected terminals 31-32. If none sensor ETF is connected, OFF must be selected. Press encoder button for OK. APPLICATION: ELECTRIC 1-ZONE ELECTRIC 2-ZONE ELECTRIC 2-STEP WATER BASED Select the application type by turning the encoder button and pressing OK. ELECTRIC 1-ZONE : 1 zone electric heating control/simple waterbased. ELECTRIC 2-ZONE : 2 zones individual electrical heating control/simple waterbased. ELECTRIC 2-STEP : Advanced 2-stage electric heating control (Y/Δ) for 1 zone. WATERBASED : 1 zone waterbased heating control with supply water control. Select the appropriate option and press OK. The system is now set up, and will begin operating fully automatically, in accordance with the pre-configured standard program, see FACTORY SETTINGS. Alternative settings can also be made, see SETTINGS. ZONE 1 HEAT OFF ZONE 2 HEAT OFF AFTERRUN 1 0.00 AFTERRUN 2 0.00 STANDBY OFF Status and afterheat data for zones 1 and 2 are now shown on the display. 5

OPERATION ETO2 is equipped with an easily operated encoder button (turn and press) and a display which describes the current situation. The display is backlit and is illuminated by pressing the encoder button (OK). The illumination is automatically switched off after 30 seconds. Press the encoder button and the main menu will be shown on the display. Turn the button to scroll through the options. Not all the options are shown on the display at once, but they can be accessed by turning the encoder button. Press OK to select a highlighted option. MAIN MENU ZONE 1 ZONE 2 SENSOR 1 SENSOR 2 MOIST 1 MOIST 2 OUT. TEMP SUPPLY W. RETURN W. ALARM SHOW INFO SETUP RESTART EXIT OFF OFF ##.# C ##.# C NO NO ##.# C ##.# C ##.# C NO 6

DISPLAY TEXTS ZONE 1 OFF Heating zone 1 active (ON) or inactive (OFF) ZONE 2 OFF Heating zone 2 active (ON) or inactive (OFF) SENSOR 1 ##.# C Sensor 1 (heated sensor) core temperature. Applies only when ETOG sensor is connected. NOTE: Not ambient temperature! SENSOR 2 ##.# C Sensor 2 (heated sensor) core temperature. Applies only when ETOG sensor is connected. NOTE: Not ambient temperature! MOIST 1 NO Sensor 1 moisture status. YES / NO / Blank. Blank will be shown if temperature is above Set Temp or the system is in Afterrun mode. MOIST 2 NO Sensor 2 moisture status. YES / NO / Blank. Blank will be shown if temperature is above Set Temp or the system is in Afterrun mode. OUT TEMP ##.# C Ambient outdoor temperature. Applies only when ETF sensor is connected. SUPPLY W. ##.# C Supply water temperature, only waterbased application RETURN W. ##.# C Return water temperature, only waterbased application 7

ALARM NO Fault message, fault type will be displayed. Red LED on front of unit will flash. APPLICATION INFO SHOW INFO APP: E. 1-ZONE Application type: electric or water-based heating SW VERSION 1.00 Software version SENSOR 1 SENSOR 2 SENSOR ETF EXIT ETOG OFF OFF Sensor type, sensor 1 Sensor type, sensor 2 ETF sensor connected Return to main menu 8

SETTINGS Please note that incorrect sensor setup may lead to poor or lacking ice and snow melting. Press OK and a submenu will be shown on the display. Select the parameter to be set and press OK. SETUP FORCE HEAT SELECT SCALE OFF C Manual start of forced heat. Press OK and select ON to start Forced heat. ETO2 controller will heat in the pre-programmed afterrun time, see AFTERRUN 1 and 2. Whether temperature is to be displayed in Celsius (C) or Fahrenheit (F) can be selected here. Select the required scale and press OK. Press OK to return to the SETUP menu. 9

SET TEMP 1 3.0C SET TEMP 2 3.0C Set temperature for Zone 1: The temperature at which the ice and snow melting system will become active can be set here. The temperature setting can be adjusted from +50 / -20 C (122 / -4 F). Set the required temperature and press OK. Set temperature for Zone 2: The temperature at which the ice and snow melting system will become active can be set here. The temperature setting can be adjusted from +50 / -20 C (122 / -4 F). Set the required temperature and press OK. OFF TEMP 1 OFF TEMP 2 OFF OFF The lowest operating temperature for Zone 1 can be set here. Below this temperature, the system will enter standby mode. The adjustment range goes down to -20 C/OFF (-3.9 F/OFF). OFF = no limit. To change the minimum cut-off temperature, press OK, turn the encoder button to the desired value and confirm with OK. The lowest operating temperature for Zone 2 can be set here. The adjustment range goes down to -20 C/OFF (-3.9 F/OFF). OFF = no limit. To change the minimum cut-off temperature, press OK, turn the encoder button to the desired value and confirm with OK. AFTERRUN 1 2:00 Afterrun time Zone 1 : An afterheat duration of between 0 and 18 hours can be set here. The system will continue to provide heat for the specified time after the moisture/temperature signal has been eliminated by a heating cycle. Use the encoder button to set the required afterrun time and press OK. 10

AFTERRUN 2 2:00 OFFSET T1 0.0C OFFSET T2 0.0C OFFSET OUT. 0.0C MIN WATER 5.0C MAX WATER 55.0C Afterrun time Zone 2 : An afterheat duration of between 0 and 18 hours can be set here. Use the encoder button to set the required afterrun time and press OK. Zone 1 temperature can be calibrated here. With ETOG-55 sensor, the temperature shown on the ETO2 display is always the core temperature of the sensor. For calibration, please see page 13. Zone 2 temperature can be calibrated here. With ETOG-55 sensor, the temperature shown on the ETO2 display is always the core temperature of the sensor. For calibration, please see page 13. Outdoor temperature can be calibrated here. The temperature, recorded by the ETF outdoor sensor, can be adjusted so that the exact temperature is displayed on ETO2. Measure the temperature beside the sensor using a thermometer. Adjust the necessary offset using the encoder button. Press OK. The minimum return water temperature can be set here. Set the required minimum temperature and press OK. This menu option is only available when water-based heating is used. The maximum supply water temperature can be set here. Set the required maximum temperature and press OK. This menu option is only available when water-based heating is used. 11

SENSOR HEAT MOIST CTRL SENSITIVITY AUTO ON NORM In auto mode, sensor heating is switched off during periods when snow melting is active. In special options or extreme cold weather the sensor heat can be selected on continuously. Select ON and press OK. The moist control on sensor can be switched off here. The termostat will only control snow and ice melting after the set temperature, see SET TEMP. Select OFF for switching off the moist control and press OK. Note that energy consumption/costs will rise with lacking moisture control. Sensor sensitivity can be adjusted in 5 steps: MIN - LOW - NORM - HIGH - MAX. To change sensitivity, press OK, turn the encoder button to the desired setting and confirm with OK. FACTORY RESET REINSTALL REINSTALL PASSWORD XXXX All ETO2 factory settings can be restored here. Selecting this option deletes all customised settings. Whether setup failure in startup menu, or new hardware connection has been done, The primare setup must be changed in STARTUP menu. Select PASSWORD and turn the encoder button to the factory code (1202) The controller will then return to the startup menu, see STARTUP. 12 EXIT Select this option and press OK to return to the main menu.

RESTART When changing the settings or require a new process start, the ETO2 can be restarted in this menu. RESTART Restart operation. Keeping your current settings. The ETO2 will go to the initial status display. OFFSET CALIBRATION If it is necessary to calibrate the temperature measured by the ETOG sensor, please follow the steps below: 1. Disconnect the sensor from terminals 11 and 12 (sensor heating) of the ETO2. 2. Wait a few hours until the sensor has acquired the same temperature as the ground. 3. Measure the real ground/sensor temperature and compare it with the temperature shown on the ETO2 display. 4. Program the offset for the sensor concerned to match the difference between the two temperatures (displayed/real). Adjust the necessary offset using the encoder button. Press OK. 5. Reconnect the sensor to terminals 11 and 12 of the ETO2. NOTE: With ETOG-55 sensor, the temperature shown on the ETO2 display is always the core temperature of the sensor. 13

FACTORY SETTINGS SETUP FACTORY SETTINGS OWN SETTINGS Application Electric Zone 1 ETOG Zone 2 OFF Select scale Celsius Afterrun time Zone 1 2.00 hours Afterrun time Zone 2 2.00 hours Temp. offset Zone 1 0.0 C / 0.0 F Temp. offset Zone 2 0.0 C / 0.0 F Temp. offset ETF 0.0 C / 0.0 F Temperature setpoint Zones 1+2 3.0 C / 37.4 F OFF temperature Zones 1+2 OFF Sensor heating Zones 1+2 AUTO Moisture control Zones 1+2 ON Sensitivity Zones 1+2 NORM Min. water temperature 5 C / 41 F Max. water temperature 55 C / 131 F 14

TROUBLESHOOTING By errors in the snow melting system, it is recommendable to check the setup of the ETO2. Activate the menu by pressing the adjustment knob, press SHOW INFO and readout the programmed application. By errors in the setup, activate REINSTALL with factory code 1202. Check that all connections are placed correctly, and that cables are fastened in the clamps. For more information on FAQ, see our website www.ojelectronics.com / support / FAQ - Snowmelting. Ice/snow does not melt Does the display show HEAT ON in zone 1 / 2? YES: o Wait 1-2 hours. o Check under the snow, if the snow is beginning to melt the system is OK. o Check heating cables for defects, bad connections, incorrect connections. o It is too cold for snow melting (power/m2) or undersized heating cables/ water heating system. 15

Does the display show HEAT ON in zone 1 / 2? NO: o The temperature is higher than SET TEMP. Adjust SET TEMP to higher temperature. o The snow around the ground sensor is melting/drifting snow has exposed the sensor. AFTERRUN time must be increased. Alternatively, FORCED HEAT can be activated. o Igloo effect around the sensor. The ground sensor has melted an insulated hollow under the snow. Activate FORCED HEAT or, alternatively, set MOIST SENSOR to OFF. o The temperature is lower than the OFF TEMP setting. Depending on dimensioning, the system has a lower temperature limit, at which the system can melt the snow. Try melting the snow with FORCE HEAT, before OFF TEMP is changed. The heat does not shut off after ice/snow melting o Afterrun time is too long reduce AFTERRUN time and activate RESTART in the menu. o Moisture detection in the ETOG/ETOR sensor is turned off set MOIST CTRL to ON in the menu. 16

If the ALARM button flashes red, one of the following errors has occurred. This can be displayed under the menu: ALARM. "RETURN TEMP LOW" "SUPPLY TEMP HIGH" "RETURN SENSOR" "SUPPLY SENSOR" "TEMP SENSOR 1" "TEMP SENSOR 2" "OUTDOOR SENSOR" "SENSOR HEATER" "FROST PROTECT" - Water temperature on return pipe is too low. - Water temperature on supply pipe is too high. - Return sensor defective. - Supply sensor defective. - Temperature sensor in ground or roof sensor 1 defective. - Temperature sensor in ground or roof sensor 1 defective. - Outdoor sensor defective. - Short circuit of heating element in ground or roof sensor. - Active frost protection due to low return temperature (waterbased systems only) 17

Fig. 1 ETOG-55 Installation Fig. 2 ETOR-55 Installation 69

Fig. 3 Electric 1-zone with ETOG-55 sensor Fig. 4 Electric 1-zone with ETOR-55 / ETF 70

Fig. 5 Electric 2-zone with ETOG, ETOR and ETF Fig. 6 ETOG-55 connections BR978A05c 2010 OJ Electronics A/S 71

Fig. 7 ETOR-55 connections Fig. 8 Electric heating cable connections 72

Fig. 9 Advanced 2-step with ETOG-55. 1/3 power on heating cables in afterrun. Fig. 10 Advanced 2-step connections. 1/3 power on heating cables in afterrun. BR978A04a 2010 OJ Electronics A/S 73

Fig. 11 Hydronic heating with mixing valve Fig. 12 Hydronic, simple application 74

Fig. 13 Hydronic mixing valve connection Fig. 14 Hydronic pump connection 75

Fig. 15 Connection of Stand by & forced heat FORCED CONTROL HEAT 76

Fig. 16 77

78

2011 Warmup Inc. 52 Federal Road - Unit 1F Danbury, CT 06810 Tel.: 1-888-927-6333 www.warmup.com