Flo-Rite-Temp Instantaneous Steam/Water Heater

Similar documents
Flo-Rite-Temp Instantaneous Steam/Water Heater

WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE

Flo-Rite-Temp Installation and Operation Manual IOM-780-N

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

High Capacity Instantaneous Steam Fired Water Heater

Pump & Trap Combinations

David Cronin-Ohio Valley Area Manager. Heat Transfer, Controls & Instrumentation, Metering.

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Economical and simplified solutions that offer quality and optimum steam trap service.

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Packaged Steam Fired Water Heater

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Packaged Semi-Instantaneous Steam Fired Water Heater

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

In-Line Air Separators

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

SECTION PLUMBING EQUIPMENT

Air Conditioning Inspections for Buildings Condensers

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

HEAT EXCHANGER FORMULAS & EXAMPLE

Design and Construction Standards SECTION PLUMBING EQUIPMENT

EZ Plate Instantaneous

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Chapter 2.3: Steam System

Silhouette. Feedwater Heater. Boiler Feedwater

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Drum Level Instrumentation and

SECTION PLUMBING EQUIPMENT

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Intelligent System Solutions Steam Air Hot Water

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Semi-Instantaneous Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

heat interface units A BOILER WITHOUT A FLAME

Automatic Temperature Controller (ATC)

Tankless On Demand Electric Water Heater

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

Tepid Water Delivery System

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Hydronic Product & Application Catalog

Documento Descargado desde:

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Drum Level Instrumentation and. The ASME Boiler Code Requirements. Presented by: Jim Kolbus. Topics

Liquid Drainers LIQUID DRAINERS

Commercial Semi-Instantaneous Water Heaters

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

INFINITY FLUIDS CORPORATION

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Thermal Fluid Heaters

TEMPERATURE CONTROLLERS

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

TECHNICAL. Series 18. Pump Packages

Thermostatic mixing valves with replaceable cartridge for centralized systems

Exciting Swiss temperature control technology, distributed in North America exclusively by...

Heat Transfer Packages

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

WATER HAMMER something that never should occur in a steam system

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

GOLD Plus 30/40/60/80

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

An Approach to Energy Efficiency: A Focus on an Increased Operational Efficiency, Natural Resource Conservation and Carbon Footprint Reduction

Transcription:

Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems are error-driven and rely upon an outlet or downstream thermostatic temperature-sensing device to detect a temperature change requirement and then modulate the steam to effect the heat exchange in an attempt to recover the heater set-point. Feedback systems are reactive, and a significant concern is their speed of response to system and application temperature control requirements. Tank-Type Steam/Water Heaters (feedback) Tank-type steam/water heaters typically include a temperature sensing element or coil immersed in a storage vessel with a separate, remote steam control valve. As a function of their integral and often significant storage capability, the poor response times often associated with the relationship of temperature-sensing device and steam control valve are less of an issue. Tank-Type Steam/Water Heaters are a less attractive option because: They consume a large amount of valuable mechanical-room real estate. They have been identified as amplification and colonization points for Legionella bacteria. They have significant leak potential over time. Tank repair is difficult, and tank replacement often requires mechanical room/building structural modifications. They consume energy to heat and maintain what is effectively a reserve hot water supply. They require separate steam control valves, which require ongoing maintenance. They require thermostatic element/sensors,which have shown a tendency to wear and eventually rupture under a heavy cycle load. They are slow to recover and may run out of hot water during peak load periods. Tankless Instantaneous Steam/Water Heaters are a less attractive option because: Lag time from message (thermostat) to action (control valve) creates thermal lag and a resulting temperature swing. Modulating steam supply can cause condensate evacuation issues, resulting in damage from water hammer and tube bundle corrosion. A cycling phenomenon during low- or no-demand periods will cause premature wear to the thermostatic element. Thermostats typically fail in an open position, making overheated, scald-temperature water available to the system. High-maintenance feedback systems with large storage tank may leak, corrode or rupture a thermostatic control. Tankless Instantaneous Steam/Water Heaters (feedback) Tankless instantaneous steam/water heaters, often referred to as shell and tube heat exchangers, do not include hot water storage capacity. These models will rely upon either an outlet or downstream temperature-sensing element with a separate steam control valve. Feedback instantaneous systems may suffer from lag time, tube bundle corrosion and problems with thermostatic element deterioration. 4

Semi-Instantaneous Steam/Water Heaters (feedback) Semi-instantaneous steam/water heaters typically include lower-capacity storage, with an integral steam control valve to deliver the heat exchange through an internally positioned element or coil. Semi-Instantaneous Steam/Water Heaters are a less attractive option because: Poor low-flow temperature control creates an accumulation tank requirement. Accumulation tank creates recovery-time issues at peak demand. Heating element/coil in generation/accumulation tank is susceptible to failure and cross contamination. Accumulation tanks have been identified as amplification and colonization points for Legionella bacteria. Although a lower-cost option, semi-instantaneous steam/water heaters are a higher-maintenance selection. Semi-instantaneous steam/water heaters have a shorter service life before replacement than other choices. Flo-Rite-Temp Instantaneous Steam/Water Heaters (feed-forward) Flo-Rite-Temp feed-forward instantaneous steam/water heaters offer a simple yet time-proven alternative to traditional feedback instantaneous, semi-instantaneous and tank-type steam-heating methods. Semi-instantaneous water heaters are subject to poor recovery time at peak demand, inadequate low-flow temperature control and shorter service life. By eliminating the temperature sensing feedback element and relying upon the actual hot water system demand requirement within the system or application, feed-forward systems respond rapidly and are extremely accurate. Flo-Rite-Temp Feed-Forward Instantaneous Steam/Water Heater is a more attractive option because: The constant, non-modulating steam pressure within the shell eliminates cycling wear and tear. The system demand or flow feed-forward activation eliminates the requirement for either steam control valve or thermostatic control device. Flo-Rite-Temp delivers a consistent outlet temperature (+/-4 F of set-point) with no thermal lag and resulting temperature swing. Flo-Rite-Temp is extremely safe because the mixing unit will position to cold water flow upon failure of the primary operating component. Flo-Rite-Temp instantaneous steam/water heaters can easily do the work of a storage tank unit many times its size at lower installed cost and with minimum maintenance. Even the largest capacity Flo-Rite-Temp requires only 7 square feet (0.63 m 2 ) of floor space. 285 5

The Flo Rite Temp instantaneous Steam/Water heater has a unique feed forward design which features a differential pressure diaphragm actuated mixing unit integral to a shell and tube heat exchanger. The Flo Rite Temp mixing unit manages the water flow through the heat exchanger based upon downstream hot water demand and eliminates the requirement for a modulating steam control valve. Operating on constant low pressure (2-15PSI) steam, the Flo Rite Temp mixing unit supplies water to the heat exchanger where it is overheated and then returned to the mixing unit for proportional re-mixing with cold water to a pre-set outlet temperature. Speed of response The differential pressure diaphragm within the mixing unit rapidly responds to a change in system demand and significantly reduces the lag times typically associated with feed back/modulating steam control valve systems. Failure Safe The Flo Rite Temp mixing units diaphragm actuated design can be described as "failure safe" because in the event of a diaphragm failure the mixing unit will fail with a cold bias and will not allow hot water to exit the heat exchanger. Outlet temperature set-point adjustment Automatic air venting Integral diaphragm actuated mixing unit eliminates intermediate pipework Scaling and fouling is reduced because the internal control valves/seats and moving parts are only exposed to cold water Differential pressure diaphragm rapidly responds to a change in system demand and significantly reduced the lag time 286 6

Temperature Control and User Safety Capable of controlling outlet temperatures +/- 4F, this principal of operation offers the additional relevant benefit of reducing the waterborne bacterial content of the water during the overheating process. In addition, with no water storage requirement, Flo Rite Temp water heaters are a sensible selection as a component of a broader system design initiative for Legionella risk reduction. Ease of Maintenance Accessible "non helical" admiralty brass straight tubes inside the carbon steel shell available mechanical cleaning and visual inspection. Non modulating constant steam pressure ensures condensate drainage and removes the potential for water hammer damage and corrosion. There in no steam control valve to maintain and typically no supplemental condensate return equipment required. How Flo-Rite-Temp Scores on Key Benefits Flo-Rite-Temp Feed- Forward Storage Tank Feedback Tankless Instantaneous Feedback Saves space Yes No Yes Saves energy Yes No Yes Eliminates temp. swings Yes Yes No Eliminates thermal lag Yes Yes No Ensures accurate control Yes Yes No Designed with straight tubes for easy cleaning Yes No No Eliminates potential health hazard of standing water Yes No Yes Fails cold for safety Yes No No Eliminates thermostatic control Yes No No Ease of Installation No storage tank, small footprint, access via a standard doorway and pre-piped packaged solutions reduce installation time, space and expenditure. Straight tubes for easy cleaning and easy removal Removable tube bundle cover/cap eases maintenance inspection and mechanical cleaning Constant steam pressure drains condensate which reduces tube bundle corrosion and water hammer issues. Floating head reduces tube stress 287 7

L Tube Bundle Removal Distance D 1 F 3/4" NPT A 1/4" NPT H 3 G E C 2 J M Model 665 and 8120 Valve B K Model 415 and 535 profile shown; 665 and 8120 profile shows that connections for water inlet and outlet are on opposite sides of the valve body. Dimensions A B C D E F G H J K L M Model in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm 415 54 1,372 4-1/2 114 7-1/2 190 7 178 4-1/2 114 3-5/16 84 3 76 7 178 6 152 6-1/4 159 50 1,270 7-1/2 190 535 67-1/2 1,715 5-1/4 133 8-5/8 219 9 229 5-9/16 141 4 102 3-11/16 94 7-7/8 200 7 178 7-1/2 191 62 1,575 9 229 665 82 2,083 5-3/4 146 10-3/8 264 10-3/8 264 6-5/8 168 4-5/8 117 4-9/16 116 9-1/4 235 8 203 8-3/4 222 74 1,880 11 280 8120 85 2,159 5-3/4 146 11-3/4 299 12 305 8-5/8 219 6 152 8-7/8 225 9-1/2 241 8 203 9-1/2 241 74 1,880 12-3/8 314 Connections and Weights Connections Model 1 2 3 Weight in (mm) in (mm) in (mm) lb kg 415 1 (25) NPT 3/4 (20) NPT 2 (50) NPT 133 60 535 1-1/2 (40) NPT 1 (25) NPT 2-1/2 (65) NPT 235 107 665 2 (50) NPT* 1-1/4 (32) NPT 3 (80) NPT 358 162 8120 3 (80) NPT* 2 (50) NPT 4 (100) 150# ANSI 585 265 *665 and 8120 connections for water inlet and outlet are on opposite sides of the valve body. Specifications Application Steam Supply Water Supply Maximum Water Pressure Pressure Pressure Drop Steam to Water 2-15 psig (0.14-1.0 bar) 20-150 psig (1.4-10.3 bar) 10 psig (0.7 bar) NOTE: Reusable insulation wraps available. Materials Body Valve Valve Seats Diaphragm (415) 303 Stainless Steel (415/535) Viton GF Bronze w/teflon Inserts 303 Stainless Steel Reinforced (535/665/8120) Brass (665/8120) Brass w/nomex Fiber NOTE: Units are NSF-61 certified. Heat Exchanger Shell Carbon Steel ASTM SA 106-B ASME U Stamped Heat Exchanger Tubes 5/8" 16 BWG Admiralty Brass Tube Sheets Brass Tube Bundle End Cap Brass 8 All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 291

Steam In TVS Trap PRV Thermostatic Air Vent CIP Connection Heated Water By-Pass Supply Water Flo-Rite-Temp Unit Setting Temperature Gauge Thermal Loops Drain Trap Water Heater Installation Detail The Flo-Rite-Temp models indentified in the submittal table below are provided, as standard, with an steam trap and thermostatic air vent (shaded). All other items indicated, are shown for water heater installation detail only. For pre-piped packaged Flo-Rite-Temp water heater assemblies, refer to pages 14-26. For submittal drawing refer to: Model 415 Single Wall S5640 Model 415DW Double Wall S5641 Model 535 Single Wall S5642 Model 535DW Double Wall S5643 Model 665 Single Wall S5644 Model 665DW Double Wall S5645 Model 665SS Stainless Steel S5646 Model 8120 Single Wall S5647 Model 8120DW Double Wall S5648 Model 8120SS Stainless Steel S5649 1 9