QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

Similar documents
QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

1022 R/T Remote Monitor

GAS MONITOR Model Model

RAM3 Remote Alarm Module

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Warranty Registration

! "! # Please read these installation and operating instructions completely and carefully before starting.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

M3050 Detector Operator s Manual

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

Warranty Registration

CMF, CMX & CMA series

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

INSTALLATION AND OPERATING INSTRUCTIONS

Model OEM-2 INSTRUCTIONS FOR USE

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

RK/ RK Combustible Gas Detector Operator s Manual

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Operation Manual. Rev. I SCC Self Contained Controller.

For the Safety of Your

Model 4001 Series Single Channel Controller

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Controllers. Instruction Manual WARNING

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

STATUS ALARM HISTORY ALARM RESET

Instruction Manual WARNING

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

MODEL QTS-8000 SERIES NON-INTRUSIVE CALIBRATION INDUSTRIAL TRANSMITTER/SENSOR

Macurco HD-11 Hydrogen Gas Detector

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

RK Carbon Monoxide Transmitter Operator s Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Gas Monitor 1A1 Series

PAD100-6DB & PAD100-4DB PAD100-PD

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

RK-02 Multi Point Detector Operator s Manual

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

3 Macurco Carbon Monoxide Detector CM-16A

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

RK CO 2 Transmitter Operator s Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

RK Combustible Gas Transmitter Operator s Manual

RK Multi Point Detector Operator s Manual

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

RK-05 Combustible Gas Transmitter Operator s Manual

RAM 50 Series Operation Manual

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

RK Carbon Monoxide Transmitter Operator s Manual

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Warranty Registration

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Steam Distribution. Installation Manual. Includes installation instructions for steam distributions ASD/BSD/CSD/RSD/SSD.

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Model 405 AIRGARD Fume Hood Monitor

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

OPERATION & MAINTENANCE MANUAL

Product Specifications Warning Light Control Cabinet

Incutrol/2 Regulator

Danfoss gas detection units

G.O.L.D. GAS OPERATIONS LEAK DETECTION USER MANUAL

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

RK Carbon Monoxide Transmitter Operator s Manual

CAUTION & SYMBOL DEFINITIONS:

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

EXAMPLES OF HOW TO ORDER

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Transcription:

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A 2Z0 PHONE: (613) 838-4005 FAX: (613) 838-4018 www.qelsafety.com email: QEL@QELsafety.com

GENERAL SPECIFICATIONS: MODEL NUMBER: SERIAL NUMBER: OPERATING RANGE: GAS TYPE ALARM SETTING LOW HIGH Carbon Monoxide 50 ppm/ve 100 ppm/ve Propane 10% LEL 20% LEL Ammonia 35 ppm 300 ppm Freon 500 ppm 1000 ppm Other SENSOR: Solid State Semiconductor Onboard Switch Setting: OFF ON 1. Low relay delay 2. High relay delay 3. Audio active on high alarm 4. Low relay active during fail 5. High relay active during fail 6. Buzzer i 21050-002-000-RB Product Rev F

TABLE OF CONTENTS 1. SPECIFICATIONS:...1 2. THEORY OF OPERATION:...2 3. INSTALLATION:...3 4. TURN-ON AND TROUBLE SHOOTING:...5 5. CALIBRATION PROCEDURE:...5 6. WARRANTY STATEMENT:...6 ii 21050-002-000-RB Product Rev F

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS 1. SPECIFICATIONS: Power Supply: 100 to 120VAC, 60Hz 8 Watts Relays: Audio Alarm: Two DPDT dry contacts 10 Amps @ 240 VAC/30 VDC Not-normally energized Field configurable time delays 85 db at 1 foot Panel Indicators: Power ON Green LED High Set point Red LED Low Set point Yellow LED Sensor Fail indication Red LED Sensor: Calibration: Expected Sensor Life: Environment: Solid State Semiconductor Recommended once per year. In excess of 5 years Temperature -30 C to 40 C Humidity 0 to 90 % non-condensing Recommended mounting height: Carbon Monoxide 4 to 6 feet above floor Propane 1 foot above floor Ammonia 9 to 18 below ceiling Freon 1 foot above floor Other Consult Factory Do not mount near fans or doors where high velocity drafts occur, or where clean air enters area. - 1-21050-002-000-RB

2. THEORY OF OPERATION: The QAS-101 series is a stand-alone hydrocarbon detector/controller designed for general-purpose applications. The QAS-101 series detects hydrocarbons and controls two relays (DPDT) that may be used to actuate fans, alarms, etc. An internal audio alarm will sound if the sensor fails and if a high alarm state exists (disable switch on board). Fail may, at the user's setting actuate either, or both relays. The sensor is a broad spectrum, economical, highly reliable sensor, with a practical life expectancy of five years minimum. The semiconductor material in the sensing element is heated to about 300 C. In the presence of a reactant gas a chemical reaction occurs at the surface, altering the quantity of Oxygen atoms adsorbed onto the surface of the semiconductor. This causes a change in the resistance of the material. The change in resistance is measured and compared to the set points to actuate relays. These sensors are 'broad spectrum' sensors in that they respond to virtually all hydrocarbons. They are also affected to a much lesser amount by humidity and temperature. The solid-state sensor responds to all components of vehicle exhaust. Although Carbon Monoxide is a major factor in vehicle exhaust, recent research has show that the unburnt fuel has long-term exposure hazards. With a sensor response relationship of 1 part CO signal to 3 parts hydrocarbon signal, we use a times 4 compensation factor for calibration gases when this sensor is used for vehicle exhaust e.g. 200 ppm CO calibration gas calibrates for 50 ppm CO in vehicle exhaust. This calibration ensures that the atmosphere remains clean of carbon monoxide and of fuel residuals. - 2-21050-002-000-RB

3. INSTALLATION: CO: Automobile-parking garages: Mount 4 to 6 feet above the floor. Bus and truck barns: Mount where vehicles exhaust upwards, it is often useful to mount the units on the ceiling. C3H8: Propane is heavier than air. Mount close to the floor and take note of any low points where gas may pool or collect. NH3: Mount at ceiling height. For high ceilings, two sensors are recommended, the second about 6 feet above the floor. Freon: Freon gases are heavier than air. Mount near the floor and take note of any low points where gas may pool or collect. Always try to mount the unit with sensor pointing downwards. Do not mount near fans or doors where high velocity drafts occur, or where clean air enters area. Most users will find it useful to have a time delay on fan starting of 5 to 10 minutes to prevent nuisance alarms. SENSOR INSTALLATION: 3-wire sensor. Shipped attached to the unit the sensor may be removed and placed remote from the unit. : Red to sensor '+' (Terminal 3) : Black to sensor '-' (Terminal 2) : Yellow to signal 'sig' (Terminal 1) Maximum loop resistance is 35 ohms for remote sensor placement (over 4000 ft for 16 AWG wires) - 3-21050-002-000-RB

FUNCTION CONTROL SWITCHES: The QAS-101 series has switches on the circuit board for controlling a number of functions: relay time delays, buzzer enable, relay actuation in case of sensor failure. 1. Low relay ON: immediate actuation OFF: 5 minutes delay 2. High relay ON: immediate actuation OFF: 10 minutes delay 3. Audio ON: audible alarm on high and fail OFF: audible alarm on fail only 4. Fail ON: fail operates low relay OFF: fail low relay disabled 5. Fail ON: fail operates high relay OFF: fail high relay disabled 6. Buzzer ON: enable OFF: disable The LED's will always turn on immediately, regardless of switch settings. RELAY WIRING: The relays are double pole, double throw, meaning that each relay is two relays in one. Each "side" having one normally open contact, and one normally closed contact arranged about a common center pin. - 4-21050-002-000-RB

4. TURN-ON AND TROUBLE SHOOTING: Upon unit power up, there is a characteristic turn-on cycle. As the sensor comes up to operating temperature and stabilizes, the signal may rise to high alarm before settling again to zero. This takes two or three minutes. (If relay time delays are turned on, this phase should pass without activating the relays). If the unit has been off for more than three days, it is best to wait three days before calibration to ensure that it has stabilized fully. If the unit has been off for only an hour or two wait at least an hour before calibrating. TEST SWITCH: Pressing the test switch on the circuit board will simulate a high alarm condition. This tests the LED and relay actuation. If time delay switches 1 and 2 are off, (time delay active) then the relays will activate after their proper delays. SENSOR FAIL DETECTION: The fail circuit detects when the sensor fails or connecting wiring is broken. The audio alarm will sound during fail, providing that switch 6 (audio enable) is on. Switches 4 and 5 may be turned on to cause the low and high relays respectively, to engage, during a fail condition. 5. CALIBRATION PROCEDURE: NOTE: Switching relays to delays mode (switches 1 and 2 off) during calibration prevents devices connected to the relay from switching on and off during calibration. a) The gas sample must be humidified by passing the gas through a small wet sponge or bubbler. QEL supplies a humidifying cap with its calibration kit, which should be wetted. NOTE: The humidifying cap can dry out quite quickly, and should be rewetted every 1/2 hour or so. b) The monitor must be powered up for three days minimum before calibration, to allow the sensor to stabilize. c) Calibrate low set point by applying the appropriate low gas to sensor and adjust low set point control potentiometer until low relay closes and the yellow LED comes on. Turning control potentiometer counter clockwise causes the LED to come on. If the relay doesn't close immediately when the LED comes on, check switch 1, as a delay may be active. d) Calibrate high set point by applying the appropriate high gas to sensor and adjusting high set point control potentiometer until the high relay closes and the red LED comes on. Turning the control potentiometer counter clockwise causes the LED to come. If the relay doesn't close immediately when the LED comes on, check switch 2 as a delay may be active. e) If power is lost momentarily integrity of the most recent calibration remains. If power is off for longer periods (days or weeks) the sensor must be allowed to stabilize for 2 days before calibration will be accurate. - 5-21050-002-000-RB

6. WARRANTY STATEMENT: The information contained in this manual is based upon data considered accurate; however, no warranty is expressed or implied regarding the accuracy of this data. All QEL equipment is warranted against defects in material and workmanship for a period of two years from date of shipment with the following exceptions: Electrochemical Sensors (Toxic) Catalytic Sensors (Combustible) Six Months One Year During the warranty period we will repair or replace, at our discretion, any components or complete units that prove, in our opinion, to be defective. We are not liable for consequential or incidental damage to auxiliary interfaced equipment. A returned material authorization number should be obtained from the factory prior to returning any goods. All return shipments must be shipped freight prepaid and a copy of the maintenance records should accompany the unit concerned. Warranty should be considered F.O.B. the factory. Labour and travel time are chargeable for any field site visits required for warranty work. LIMITED LIABILITY All QEL systems shall be installed by a qualified technician/electrician and maintained in strict accordance with data provided for individual systems in the form of installation/maintenance manuals. QEL assumes no responsibility for improper installation, maintenance, etc., and stresses the importance of reading all manuals. QEL shall not be responsible for any liability arising from auxiliary interfaced equipment nor any damage resulting from the installation or operation of this equipment. QEL s total liability is contained as above with no other liability expressed or implied, as the purchaser is entirely responsible for installation and maintenance of systems. This warranty is in lieu of all other warranties, expressed or implied, and no representative or person is authorized to represent or assume for QEL any liability in connection with the sales of our products other than that set forth herein. NOTE: Due to on-going product development, QEL reserves the right to change specifications without notice and will assume no responsibility for any costs as a result of modifications. For further information or assistance, contact: QUATROSENSE ENVIRONMENTAL LTD. 5935 Ottawa Street, PO Box 749 Richmond, Ontario K0A 2Z0 Tel: (613) 838-4005 Fax: (613) 838-4018 Email: QEL@QELsafety.com Web: www.qelsafety.com - 6-21050-002-000-RB