Refrigeration Temperature Controller

Similar documents
Refrigeration Temperature Controller

USER MANUAL. Copyright Reserved Autonics Co., Ltd. iii

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

TK Series. High Function/High Performance PID Control.

Control output N Indicator - Without control output R Relay output + SSR drive output (4-digit) Set by touch switch

R Relay output S SSR drive output C Selectable current output or SSR drive output VAC 50/60Hz

TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information.

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

Series Temperature Controller Instruction Sheet

KPN Series. Features. Manual. Integrated device management program(daqmaster)

KPN Series. Features. Manual. Integrated device management program(daqmaster)

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

General Specifications

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None

KPN Series. Features. Manual. Software

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Series Digital Controller Instruction Sheet

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Temperature Controllers

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

02/11/2015

M1000 Alarm Annunciator

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Instruction manual Temperature Controller KT7

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

02/11/2015

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ECO N DATE DESCRIPTION OF CHANGE CHG

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Lift Station Level Controller

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

TEMPERATURE CONTROLLER

CLEANROOM MONITOR CR3A Network - Installation Instructions

RS485 MODBUS Module 8AI

F4 Process Controller Installation and Operation Guide

ER65 - Mini Rack Controller Electronic Refrigeration Line

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Installation Manual Tracker 221

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

SHIMADEN DIGITAL INDICATORS

Instruction manual for DIN rail mounting type indicating controller DCL-33A

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Dixell Installing and Operating Instructions release 7.0

SACE PR021/K SIGNALLING UNIT

DIGITAL INDICATOR JIR-301-M

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

I/A Series 716C 1/16 DIN Temperature Controller

Refrigerated air dryers

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

OVEN INDUSTRIES, INC.

DTSX200 Communications(Modbus) Guide

INSTRUCTION MANUAL Micro-computer based digital indicating controller

ER52 - Evaporator Controller

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Digital Heater Element Burnout Detector K8AC-H

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

IN NOURISHING SECURITY.

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Danfoss gas detection units

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

GCS-300 No.GCS31E

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Bottle cooler controllers Solutions for static, ventilated and open coolers

Thermometers and temperature controllers

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

AIS750 Series Alarm Annunciator

Instruction manual Micro-computer based digital indicating controller

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

EXD-SH1/2 Controller for EX/FX/CX with ModBus Communication Capability

Preface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I

MO n : 12JMC rév A

TraceNet ECM Series Control System

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Transcription:

TF3 eries Refrigeration Controller Features tandard installation size for refrigeration and air-cooling panels (W7.3 H28.2mm) Various compressor load current capacity: 5A, 16A, 2A Various user-friendly functions: - Defrost sync function: simultaneous defrost operation of multiple controllers (up to 6 units) - RTC (Real Time Clock) function: night mode operation and real-time defrost control - Built-in alarm function Remote monitoring of real-time temperature and output control (using TFD series remote display unit, sold separately) Communication output models available: R485 (Modbus RTU) Parameter configuration via PC (R485 communication) - DAQMaster software included (comprehensive device management software) IP65 protection structure (IEC standard): front panel only NEW Please read afety Considerations in operation manual before using. Manual Visit our website (www.autonics.com) to download user manual and communication manual. User manual describes for specifications and function, and communication manual describes for R485 communication (Modbus RTU protocol) and parameter address map data. Comprehensive Device Management Program (DAQMaster) DAQMaster is comprehensive device management program. It is available for parameter setting, monitoring, and user parameter group setting, parameter mask setting for only TF3 eries. Visit our website (www.autonics.com) to download user manual and comprehensive device management program. < Computer specification for using software > < DAQMaster screen > Item ystem Operating system Memory Hard disk VGA Others Minimum requirements IBM PC compatible computer with Intel Pentium Ⅲ or above Microsoft Windows 98/NT/XP/Vista/7/8/1 256MB or more More than 1GB of free hard disk space 124 768 or higher resolution display R-232 serial port (9-pin), UB port H-2

Refrigeration Controller Ordering Information TF 3 3 3 4 H T Option function 2 load capacity Power supply Output Number of input channels Digits Item No-mark T R 3 A 3 G 1 A H No option ynchronize defrost R485 communication RTC (real time clock) R485 communication+rtc (real time clock) 2A 1a contact 5A 1a contact 16A 1c contact 1 24VAC 5/6Hz, 12-24VDC 4 1-24VAC 5/6Hz 1CH 1 output 1CH, 3CH +Defrost or Auxiliary 2 (alarm/evaporator-fan) output 3 +Defrost+Auxiliary (alarm/evaporator-fan) output 1 1CH input (NTC or RTD) [temperature+digital input (DI)] 3CH input (NTC) 3 [inlet temperature+defrost temperature+ outlet temperature or digital input (DI)] 3 999 (3-digit) TF Refrigeration Controller (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power (J) Counters 1: Only for 1CH input, compressor output model (TF31-1 G). 2: Only for 3CH input model (TF33- - ). Option function is varied by compressor load capacity and contact. Option function load capacity & contact 5A 1a contact ynchronize defrost function R485 communication (TF33- A-) (TF33- A-T) 16A 1c contact - - RTC function - (TF33-3 H-R) R485 communication+ RTC function (TF33-3 - A-A) No option - (TF33- H) 3: Except compressor+defrost or auxiliary (alarm/evaporator-fan) output model (TF33-2 - ) Only for 3CH input, compressor+defrost+auxiliary (alarm/evaporator-fan) output model (TF33-3 - ) supports buzzer. (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units (O) ensor Remote Display Unit (TFD eries, old eparately) Remote display unit (TFD) displays current temperature or output status of TF3 at remote place. TFD cable is TFD-3: 3m, TFD-5: 5m. Connect the phone-jack of remote display unit (TFD) to the data loader port of TF3. This unit is dedicated for TF3 eries and it does not directly communicate with upper devices (PC, PLC, etc.) If TFD communication with TF3 error occurs, TFD flashes display component for 1 sec. Check the connection with TF3. (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware When connecting TFD to the data loader port of TF3, you cannot connect Autonics CM-U (UB to erial converter, sold separately). for communication. Use CM-U48I(UB to R485 converter, sold separately), CM-38I(R232C to R485 converter, sold separately). H-3

TF3 eries pecifications TF3 eries Model TF31- TF33- - Number of channels 1CH 3CH Power supply AC power 1-24VACᜠ 5/6Hz AC/DC power 24VACᜠ 5/6Hz, 12-24VDCᜡ Allowable voltage range 9 to 11% of rated voltage Power AC power Max. 8VA (1-24VACᜠ 5/6Hz) consumption AC/DC power Max. 5VA (24VACᜠ 5/6Hz), Max. 3W (12-24VDCᜡ) Display method 7 egment LED method (red) Character size (W H) 9.4 19.3mm NTC 5kΩ/1kΩ Input type RTD DPt1Ω - ampling period 5ms Display accuracy At room temp. (23 ±5 ): ±1 ±1 digit Out of room temp. range: ±2 ±1 digit Control output Remote display unit [TFD] Model TFD-3 TFD-5 Power supply 3.3VDCᜡ Power consumption Max. 1W Display method 7 egment LED method (red) Communication method erial (TTL Level), Half duplex Communication cycle 1ms Cable Ø2.5mm, 3m Ø2.5mm, 5m Vibration 1.5mm amplitude at frequency of 1 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Enviornment (COMP) 25VACᜠ 5A, 3VDCᜡ 5A, 1a / 25VACᜠ 16A, 24VDCᜡ 16A, 1c / 25VACᜠ 2A 1a Defrost (DEF) 25VACᜠ 1A, 24VDCᜡ 1A, 1a Auxiliary (AUX) 25VACᜠ 5A, 3VDCᜡ 5A, 1a Communication output - R485 communication output (Modbus RTU) Digital input Control method Hysteresis Relay life cycle (COMP) Contact input: max. 1kΩ, min. 1kΩ No contact input: residual voltage: max. 1V, leakage current: max. 1mA, outflow current: 4μA / control.5 to 5., 2 to 1 variable 5A 1a Mechanical: 5,, operations, Electrical: 5, operations (25VAC 5A) 16A 1c Mechanical: 2,, operations, Electrical: 3, operations (25VAC 16A) 2A 1a Mechanical: 1,, operations, Electrical: 1, operations (25VAC 2A) Defrost (DEF) Mechanical: 2,, operations, Electrical: 1, operations (25VAC 1A) Auxiliary (AUX) Mechanical: 5,, operations, Electrical: 5, operations (25VAC 5A) Memory retention Approx. 1 years (non-volatile memory method) Insulation resistance Min. 1MΩ (at 5VDC megger) Dielectric AC power strength AC/DC power Noise resistance Vibration Environ ment 3VAC 5/6Hz for 1 min (between all terminals and case, power and input circuit) 1VAC 5/6Hz for 1 min (between all terminals and case, power and input circuit) quare-wave noise by the noise simulator (pulse width: 1μs ) ±2kV R-phase and -phase 1.5mm amplitude at frequency of 1 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Ambient temperature -1 to 5, storage: -2 to 6 Ambient humidity 35 to 85%RH, storage: 35 to 85%RH Accessories Bracket: 2, NTC sensor (5kΩ): 1 Protection structure IP65 (front case) Approval Weight 1 Approx. 27g (approx. 15g) Ambient temp. -1 to 5, storage: -2 to 6 Ambient humi. 35 to 85%RH, storage: 35 to 85%RH Protection structure IP67 Approval Weight 1 Approx. 77g (approx. 48g) 1: The weight includes packaging. The weight in parentheses is for unit only. The weight is varied by model option. Environment resistance is rated at no freezing or condensation. H-4

Refrigeration Controller Connections Use crimp terminals of size specified below. c <Crimp terminal> Terminal number a b c General 1 to 4 4 to 6mm Max. 1.7mm Max. 3.7mm TF3 - H 5 to 1 6 to 8mm Max. 2.3mm Max. 4.5mm 5 to 6 6mm Max. 1.9mm Max. 4.mm TF3 - A 7 to 1 6 to 8mm Max. 2.3mm Max. 4.5mm TF3 - G 6 to 7 6 to 8mm Max. 2.3mm Max. 4.5mm General 11 to 12 6mm Max. 1.9mm Max. 4.mm a b TF31-1 G TF31- A (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders COMP OUT 25VAC 2A REITIVE LOAD COMP OUT 25VAC 5A 3VDC 5A REITIVE LOAD DEF OUT AUX OUT 25VAC 1A 25VAC 5A 24VDC 1A 3VDC 5A REITIVE REITIVE LOAD 1 LOAD 2 (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) NTC 5K/1K NTC 5K/1K (I) Rs / Power DPt1 ENOR DIGITAL INPUT TF31- H COMP OUT 25VAC 16A 24VDC 16A REITIVE LOAD DEF OUT 25VAC 1A 24VDC 1A REITIVE LOAD 1 OURCE 1-24VAC 5/6Hz, 24VAC 5/6Hz, 12-24VDC AUX OUT 25VAC 5A 3VDC 5A REITIVE LOAD 2 DPt1 ENOR DIGITAL INPUT OURCE 1-24VAC 5/6Hz, 24VAC 5/6Hz, 12-24VDC (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units NTC 5K/1K DPt1 ENOR DIGITAL INPUT OURCE 1-24VAC 5/6Hz, 24VAC 5/6Hz, 12-24VDC (O) ensor (P) witching Mode Power upplies TF33- A- 1 2 3 COM COMP OUT 25VAC 5A 3VDC 5A REITIVE LOAD DEF OUT AUX OUT 25VAC 1A 25VAC 5A 24VDC 1A 3VDC 5A REITIVE REITIVE LOAD 1 LOAD 2 TF33- H- 1 2 3 COM COMP OUT 25VAC 16A 24VDC 16A REITIVE LOAD DEF OUT 25VAC 1A 24VDC 1A REITIVE LOAD 1 AUX OUT 25VAC 5A 3VDC 5A REITIVE LOAD 2 (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices A+ B- NTC 5K/1K YNCHRIZE ENOR /R485 3 DIGITAL INPUT OURCE 1-24VAC 5/6Hz, 24VAC 5/6Hz, 12-24VDC NTC 5K/1K ENOR DIGITAL INPUT OURCE 1-24VAC 5/6Hz, 24VAC 5/6Hz, 12-24VDC 1: Only for compressor+defrost or auxiliary (alarm/evaporator-fan) output model (TF3-2 - ), compressor+defrost+auxiliary (alarm/evaporator-fan) output model (TF3-3 - ). 2: Only for compressor+defrost+auxiliary (alarm/evaporator-fan) output model (TF3-3 - ). 3: Only for synchronize defrost function model (TF33- A-), or R485 communication model (TF33- A-T/A). (T) oftware H-5

TF3 eries Dimensions TF3 eries 77 5.5 74.3 (unit: mm) 37.5 4.5 35 28 NTC sensor (5kΩ) Max. 5 AWG22 TPE lead wire Bracket 3.3 oldering 46 6±.2 4 Max. 15 5±1 12 2±5 23.9 Panel cut-out A ize eries A B C D (unit: mm) D TF3 Min. 1 1 Min. 55 7.3 +.7 28.2 +.5 B C TFD Min. 65 Min. 4 45.7 +.6 25.4 +.3 1. When connecting remote display unit (TFD), or CM-U, Min. 12 old eparately TFD 52 3 12 31.5 25 Communication converter CM-WF48 ( Wi-Fi to R485 UB wireless communication converter) CM-U48I (UB to R485 converter) Ø2.5, 3m or 5m CM-38I (R232C to R485 converter) CM-U (UB to erial converter) H-6

Refrigeration Controller Product Mounting (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors Unit Description 3 4 5 6 2 (-) driver 1 8 9 7 11 1 Insert the unit into a panel, fasten the bracket by pushing with tools with a (-) driver. 1. Present value (PV) display component (red): RUN mode: Displays present value (PV). etting mode: Displays parameter and setting value. 2. Deviation indicator ( : green, / : red): Displays deviation of present value (PV) based on setting value (V). PV deviation temperature More than 1.8 Within ±1.8 Less than -1.8 Deviation display indicator turns indicator turns indicator turns 3. (COMP) output indicator (green): Turns for compressor output. In case of compressor protection operation and output does not turn, it flashes. When operating compressor continuously, it turns for 2 sec, and turns for 1 sec. (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units 12 4. Defrost (DEF) output indicator (green): Turns for defrost output. Flashes for defrost delay operation. Turns for 2 sec and for 1 sec for manual defrost or Power defrost. 5. Evaporator-fan (FAN) output indicator (green): Turns for evaporator-fan output. Flashes for delay operation of evaporator-fan output. 6. Auxiliary (AUX) output indicator (green): Turns for alarm output. Flashes for delay operation of alarm output. 7. Unit indicator (red): Displays temperature unit set at temperature unit [UNT] of parameter 1 group. 8. (MODE) key: Used for entering parameter setting group, returning RUN mode, moving parameter or saving V. 9. (AUX) key: Used for entering V setting group or changing setting value. Hold the key over 3 sec to select active/inactive auxiliary output in RUN mode. 1. (DEF) key: Used for entering V setting group or changing setting value. Hold the key over 3 sec to execute/stop manual defrost in RUN mode. 11. (COMP) key: Used for entering V setting group, changing setting value, moving digits. Hold the key over 3 sec to active/inactive compressor output in RUN mode. When buzzer alarm occurs, press the key once to stop the sound. (Only for 3CH input, compressor+defrost+auxiliary (alarm/evaporator-fan) output model (TF33-3 - ) supports buzzer. Buzzer [BUZ] of parameter 1 group is set as []) 12. Data loader port: It is for displaying TF3 data at remote display unit (TFD) by connecting phone-jack. In other case, for connecting Autonics CM-U (UB/erial converter, sold separately), it is a PC loader port of serial communication for parameter setting or monitoring by PC. (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware H-7

TF3 eries Parameter Group Press any key among,, once RUN mode 2 sec P 1 P 1 P 1 When PW is valid When PW is valid When PW is valid V setting [V] aved automatically after 3 sec Display selection [DpT] Parameter user group [PAU] 2 Parameter 1 group [PA1] Monitoring time [MoT] 1.5 sec User parameter Input type [ ㅑ INT] 1.5 sec 1.5 sec Max. value [hpk] Min. value [lpk] 1.5 sec User parameter 1 to 29 Input sensor 2 / [2] Input sensor 3 selection [3] Virtual temperature rate [VtR] unit [UNT] Input correction 1 [Ib1] Input correction 2 [Ib2] Input correction 3 [Ib3] Delay display period [DsT] Defrost/auxiliary output [sda] Auxiliary output [AUX] Buzzer [BUZ] 1. [P] parameter appears only when password is set. The default password is []. If password is not valid, the password code appears. Press any key among the,, keys to return to password entering window. Press the (MODE) key to return to RUN mode. If you forget password, contact Autonics after checking password code. 2. It appears when setting user parameter group in the comprehensive device management program (DAQMaster). Press the (MODE) key after changing the setting to save the V. Hold the (MODE) key for 1.5 sec while in setting mode to move to the parameter group. Hold the (MODE) key for 3 sec while in setting mode to return RUN mode. Press the (MODE)key at the last parameter of each parameter group, it moves to that parameter group name. You can move to other groups with, keys. If there is no additional key operation within 3 sec after entering into setting mode, it will be automatically returned to RUN mode and previous setting value will be remained. The shaded parameters are displayed when user level [UR] of parameter 5 group is set as standard level [TD]. 3 sec 3 sec H-8

Refrigeration Controller (A) Photoelectric ensors 3sec (B) Fiber Optic ensors (C) Door/Area ensors Parameter 2 group [PA2] Parameter 3 group [PA3] Parameter 4 group [PA4] Parameter 5 group [PA5] (D) Proximity ensors (E) Pressure ensors Comp. output mode [OFT] Defrost method & operation [DEF] Defrost cycle [DIN] Real-time defrost cycle [rdi] Real-time defrost cycle 1: hour [DH1] Real-time defrost cycle 1: min [DM1]... Real-time defrost cycle 8: hour [DH8] Real-time defrost cycle 8: min [DM8] Defrost time [ ㅇ DET] Pump down delay time [PdD] Defrost end delay time [DrT] Defrost end temperature [EDT] Defrost hysteresis [dhy] Defrost when power [pde] Defrost delay when power / manual defrost [dde] Defrost group [dgr] Parameter copy [pdc] Prior defrost selection [dpr] Defrost time unit [ude] Alarm delay after defrost/ door open [AdD] display during defrosting [tde] Alarm operation mode [AL] Alarm option [AlT] Alarm high-limit deviation [AlH] Alarm low-limit deviation [AlL] Alarm hysteresis [ahy] Alarm delay time [a] Alarm delay time [aof] External alarm delay time [ead] Alarm output method [an] Evaporator-fan operation [fty] Evaporator-fan control temperature [ft] Evaporator-fan hysteresis [fhy] Evaporator-fan mode [FAN] Evaporator-fan start-up delay time [pdr] Current hour [CUH] 1.5sec 1.5sec 1.5sec 1.5sec Hysteresis [HY] Offset [OF] V high-limit [HV] V low-limit [LV] Night mode [nmd] Night mode V correction [nv] Night mode hysteresis [nhy] Night mode offset [nof] Night mode start hour [nh] Night mode start min [nm] Night mode end hour [neh] Night mode end min [nem] monitoring [emo] Comp. start-up delay time [DL] Comp. min. operation cycle [CYC] Comp. restart delay time [RDL] Comp. min. operation time [T] Comp. continuous operation [CC] Alarm delay time after continuous operation [AdC] Comp. operation cycle when sensor break [CLE] Comp. duty rate when sensor break [DUT] Current minute [CUM] Digital input [DI] Loop break alarm monitoring time [LBA] Comm. address [ADR] Comm. speed [BP] Comm. parity bit [PRT] Comm. stop bit [TP] Comm. response wait time [RwT] Comm. write [COW] User level [UR] V setting group lock [lv] Front key lock [ldk] PA group lock [lp] PA user group lock [lpu] PA 1 group lock [lp1] PA 2 group lock [lp2] PA 3 group lock [lp3] PA 4 group lock [lp4] PA 5 group lock [lp5] Password [PWD] (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware 3 sec 3 sec 3 sec 3 sec H-9

TF3 eries Parameter 1 Group 1. : Press any key among,, keys. 3 sec 'P 1 PW code appears at V display part for wrong PW When PW is wrong RUN mode Password input 2 sec When PW is correct + 1 time 'P After entering setting mode, hold the (MODE) key anytime for 3 sec to return to RUN mode. After entering setting mode, hold the (MODE) key anytime for 1.5 sec to go to the concerned group name. If you press the (MODE) key after changing the set value of the parameter the set value will be stored. haded parameters are for standard-level users, the others are for high-level users. (You can set the user level [UR] in parameter 5 group).) This parameter might not be displayed depending on other parameter settings or model specifications. Parameter 1 group PA1 Input type INT 2 Input sensor 2 / NsH NsL DpL etting range: Refer to input type and range. When changing input type, V, hpk, lpk, Ib1, Ib2, Ib3, HY, OF, HV, LV, nv, nhy, EDT, dhy, AlH, AlL, ahy, ft, fhy parameter values are reset. Input sensor 3 selection 3 DI T Appears only for 3CH input model. Virtual temperature rate VtR etting range: to 1% Appears only when input sensor 3 selection [INT] is set as [T]. unit UNT Input correction 1 Ib1?C?F When changing temperature unit, hpk, lpk, Ib1, Ib2, Ib3, HY, OF, HV, LV, nv, nhy, EDT, dhy, AlH, AlL, ahy, ft, fhy parameter values are reset. etting range: -4 to 4 / Input correction 2 Ib2 Input correction 3 Ib3 etting range: -4 to 4 / Appears only for 3CH input model. Delay display period DsT )5 etting range:.5 to 1. sec Defrost/ auxiliary output sda DEF AUX Appears only for compressor+defrost or auxiliary (alarm/evaporator-fan) output model. Auxiliary output AUX Buzzer BUZ FAN ALM Appears only for compressor+defrost or auxiliary (alarm/evaporator-fan) output model, compressor+defrost+auxiliary (alarm/evaporator-fan). Only for 3CH input, compressor+defrost+auxiliary (alarm/evaporator-fan) output model supports buzzer. H-1

Refrigeration Controller Parameter 2 Group 1. : Press any key among,, keys. 3 sec 'P 1 PW code appears at V display part for wrong PW When PW is wrong RUN mode Password input 2 sec 'P When PW is correct + 2 times Parameter 2 group PA2 After entering setting mode, hold the (MODE) key anytime for 3 sec to return to RUN mode. After entering setting mode, hold the (MODE) key anytime for 1.5 sec to go to the concerned group name. If you press the (MODE) key after changing the set value of the parameter the set value will be stored. haded parameters are for standard-level users, the others are for high-level users. (You can set the user level [UR] in parameter 5 group).) This parameter might not be displayed depending on other parameter settings or model specifications. (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders Comp. output mode OFT Hysteresis HY C 1 H When changing compressor output mode, CLE, DUT parameter values are reset. etting range: 1 to 5 (.5 to 5. ), 2 to 1 (2. to 1. ) (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power Offset OF etting range: to 5 (. to 5. ), to 1 (. to 1. ) (J) Counters V high-limit HV 99 etting range: (LV+1digit) to high-limit value of input type When changing V high-limit value and V > HV, V is reset as HV. (K) Timers (L) Panel V low-limit LV -4 etting range: low-limit value of input type to (HV-1digit) When changing V low-limit value and V < LV, V is reset as LV. (M) Tacho / peed / Pulse Night mode nmd Night mode V correction nv Night mode hysteresis nhy 1 1 TIN DI etting range: -2 to 2 (-2 to 2. )/ -5 to 5 (-5 to 5. ) etting range: 1 to 5 (.5 to 5. ), 2 to 1 (2. to 1. ) Appears for RTC function model or when digital input [DI] is set as [nmd]in parameter 5 group. Does not appear when night mode [nmd] is set as []. (N) Display Units (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels Night mode offset nof etting range: to 5 (. to 5. ), to 1 (. to 1. ) () Field Network Devices Night mode start hour nh Night mode start min. nm etting range: to 23 hour etting range: to 59 min Appears for RTC function model. Does not appear when night mode [nmd] is set as [, DI]. (T) oftware H-11

TF3 eries Night mode end hour neh Night mode end min. nem 8 etting range: to 23 hour etting range: to 59 min Appears for RTC function model. Does not appear when night mode [nmd] is set as [, DI]. monitoring emo 1 V etting range:, 1, 2, 3, V Comp. start-up delay time DL Comp. min. operation cycle CYC Comp. restart delay time RDL etting range: to 6 min Comp. min. operation time T Comp. continuous operation CC Alarm delay time after continuous operation AdC 2 etting range: () to 24 hour Comp. operation cycle when sensor break CLE etting range: to 1 min Comp. duty rate when sensor break DUT 5 etting range: to 1% H-12

Refrigeration Controller Parameter 3 Group 3 sec 'P 1 PW code appears at V display part for wrong PW When PW is wrong RUN mode Password input 2 sec 'P When PW is correct + 3 times Parameter 3 group PA3 Defrost method & operation DEF Defrost cycle DIN etting range: In case of compressor output model, below parameters of parameter 3 group do not appear. 1. : Press any key among,, keys. After entering setting mode, hold the (MODE) key anytime for 3 sec to return to RUN mode. After entering setting mode, hold the (MODE) key anytime for 1.5 sec to go to the concerned group name. If you press the (MODE) key after changing the set value of the parameter the set value will be stored. haded parameters are for standard-level users, the others are for high-level users. (You can set the user level [UR] in parameter 5 group).) This parameter might not be displayed depending on other parameter settings or model specifications. htm gtm htt gtt 4 etting range: to 24 hour/ to 1 min (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power Real-time defrost cycle rdi (J) Counters (K) Timers Real-time defrost cycle : hour DH Real-time defrost cycle : min DM etting range: to 23 hour, etting range: to 59 min, You can set up to 8 real-time defrost cycles: hour, min. (L) Panel (M) Tacho / peed / Pulse (N) Display Units Defrost time DET Pump down delay time PdD 3 ) etting range: 1 to 1 min/1 to 1 sec (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & Defrost end delay time DrT! etting range: min sec to 9 min 59 sec (R) Graphic/ Logic Panels () Field Network Devices Defrost end temperature EDT 4 etting range: -4 to 99, -4 to 212 (T) oftware Defrost hysteresis dhy 1 etting range: 1 to 5 (.5 to 5. ), 2 to 1 (2. to 1. ) H-13

TF3 eries Defrost when power pde Defrost delay when power /manual defrost dde etting range: to 6 min Defrost group dgr MA LV Parameter copy pdc Prior defrost selection dpr Defrost time unit ude HGH LOW Alarm delay after defrost/door open AdD 1 etting range: to 24 hour display during defrosting tde Parameter 4 Group 1. : Press any key among,, keys. 3 sec 'P 1 PW code appears at V display part for wrong PW When PW is wrong RUN mode Password input 2 sec 'P When PW is correct + 4 times After entering setting mode, hold the (MODE) key anytime for 3 sec to return to RUN mode. After entering setting mode, hold the (MODE) key anytime for 1.5 sec to go to the concerned group name. If you press the (MODE) key after changing the set value of the parameter the set value will be stored. haded parameters are for standard-level users, the others are for high-level users. (You can set the user level [UR] in parameter 5 group).) This parameter might not be displayed depending on other parameter settings or model specifications. Parameter 4 group PA4 etting range: In case of compressor output model, below parameters of parameter 4 group do not appear. Alarm operation mode AL AlD Alarm option AlT AlA AlB AlF etting range: AlA, AlB, AlC, AlD, AlE, AlF When changing alarm option, AlH, AlL, AhY parameter values are reset. H-14

Refrigeration Controller Alarm high-limit deviation AlH Alarm low-limit deviation AlL 139 139 etting range: -F.. to F. (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors Alarm hysteresis ahy 1 etting range: 1 to 5 (.5 to 5. ), 2 to 1 (2. to 1. ) (D) Proximity ensors (E) Pressure ensors Alarm delay time a (F) Rotary Encoders Alarm delay time aof etting range: to 6 min (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) External alarm delay time ead (I) Rs / Power Alarm output method an NO NC (J) Counters (K) Timers Evaporator-fan operation fty FAN DEF (L) Panel Evaporator-fan control temperature ft 4 etting range: -4 to 99, -4 to 212 (M) Tacho / peed / Pulse (N) Display Units Evaporator-fan hysteresis fhy Evaporator-fan mode FAN Evaporator-fan start-up delay time pdr 1! etting range: 1 to 5 (.5 to 5. ), 2 to 1 (2. to 1. ) EF1 EF2 EF5 etting range: EF1, EF2, EF3, EF4, EF5 etting range: min sec to 9 min 59 sec (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware H-15

TF3 eries Parameter 5 Group 3 sec 'P 1 PW code appears at V display part for wrong PW When PW is wrong RUN mode Password input 2 sec 'P PA5 When PW is correct + 5 times Parameter 5 group 1. : Press any key among,, keys. After entering setting mode, hold the (MODE) key anytime for 3 sec to return to RUN mode. After entering setting mode, hold the (MODE) key anytime for 1.5 sec to go to the concerned group name. If you press the (MODE) key after changing the set value of the parameter the set value will be stored. haded parameters are for standard-level users, the others are for high-level users. (You can set the user level [UR] in parameter 5 group).) This parameter might not be displayed depending on other parameter settings or model specifications. Current hour CUH Random hour etting range: to 23 hour Current minute CUM Random min etting range: to 59 min Appears only for RTC function model. Digital input DI ㅒ stp mdf etting range:, stp, dw, nmd, eal, edf, mdf Loop break alarm monitoring time LBA etting range: to 1 min Comm. address ADR 1 etting range: 1 to 99 Comm. speed BP ㅒ 96 192 48 etting range: 24, 48, 96, 192,384 Multiply V 1 to read. Comm. parity bit PRT N EVN ODD Comm. stop bit TP 2 1 Appears only for R485 communication model. Comm. response wait time RwT 2 etting range: to 99ms Comm. write COW EnA DsA H-16

Refrigeration Controller User level UR V setting group lock lv TD HGH (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors Front key lock ldk (D) Proximity ensors (E) Pressure ensors Parameter group lock lp Password PWD (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power Parameter Reset Hold + + keys for 5 sec to reset all parameters in memory to default value. et [INI] parameter to [YE] to reset all parameters. In case password function is, it is required to enter valid password to reset parameters. Password is also reset. (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware H-17

TF3 eries Front Panel Display When Power Is On When power supplies to the unit, whole display part flashes approx. 1 sec. The display part displays model specification (no. of input CHs, output, power supply, compressor load capacity, option function), flashes input type twice and the unit returns to RUN mode to operate. Model specification display is same as the unit model name. (E.g.: TF33-34A-A model) 1. Whole display part 2. eries 3. No. of input CHs/Output/Power supply 4. load capacity/ Option function 5. Run mode ensor input error Normal operation V etting You can set the temperature to control with the,, keys. et range is within V low-limit value [LV] to V high-limit value [HV]. E.g.) In case of changing V from 19 to 1 1 2 Press any key among the,, in RUN mode to enter into V setting mode. Last digit (1 digit) on V display part flashes. Press the key to move digit. (1 1¹ 1² 1³ 1 ) 3 4 Press the, key to raise or lower the set value. (9 ) Press the (MODE) key to save the set value. (If there is no additional key operations in 3 sec, the changed V is automatically saved.) Input type Decimal point Display method range ( ) range ( ) 1 N%H -4 to 99-4 to 212-4 to -2 NTC 5kΩ -4 to -2.1 N%L -19.9 to 99.9-19.9 to 99.9 Thermistor 1 to 212 (NTC) 1 N!H -4 to 99-4 to 212 RTD 1 Input Type and Range NTC 1kΩ DPt 1Ω.1 N!L -4 to -2-19.9 to 99.9-4 to -2-19.9 to 99.9 1 to 212 1 DpH -99 to 99-148 to 212.1 DpL -99 to -2 2-19.9 to 99.9-148 to 212 TF3 eries displays only 3 digits. If PV decimal number of shaded temperature range is out of 3 digit, TF3 does not display the numbers below decimal point. You can check it at the comprehensive device management program (DAQMaster) by communicating via PC. 1: Only for 1CH input model (TF31- ). 2: If PV with "-" sign is over 3 digits (e.g.: -99.9), the numbers below decimal point does not display. You can check it at the comprehensive device management program (DAQMaster) by communicating via PC. H-18

Refrigeration Controller Factory Default V setting [V] Parameter Factory default V Parameter 1 group [PAR1] Parameter group Parameter Factory default DpT 1 MoT - (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors Parameter Factory default Parameter Factory default Parameter Factory default INT NsH UNT?C AUX 2 Ib BUZ 3 DI DsT )5 VtR sda DEF (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders Parameter 2 group [PAR2] Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default OFT C nv 1 nem CC HY 1 nhy 1 emo AdC 2 OF nof DL CLE HV 99 nh CYC DUT 5 LV -4 ntm RDL nmd neh 8 T (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power (J) Counters ㅗ Parameter 3 group [PAR3] Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default DEF htm DET 3 pde ude HGH DIN 4 PdD ) dde AdD 1 rdi DrT! dgr tde DH EDT 4 pdc DM dhy 1 dpr (K) Timers (L) Panel (M) Tacho / peed / Pulse Parameter 4 group [PAR4] Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default AL AlD ahy 1 an NO FAN EF1 AlT AlA a fty FAN pdr! AlH 139 aof ft 4 AlL 139 ead fhy 1 Parameter 5 group [PAR5] Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default CUH Random hour ADR 1 RwT 2 ldk CUM Random min BP 96 COW EnA lp DI PRT N UR TD PWD LBA TP 2 lv (N) Display Units (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware H-19

TF3 eries Alarm (Except 1CH, Output Model: TF31-1 ) et both alarm operation and alarm option by combining. Alarm function is available for compressor+defrost or auxiliary (alarm/evaporator-fan) output model (TF3-2 - ). Also defrost/auxiliary output [sda] of parameter 1 group should be set as auxiliary [AUX], and auxiliary output [AUX] should be set as alarm [ALM]. In case of compressor+defrost+auxiliary (alarm/evaporator-fan) output model (TF3-3 - ), auxiliary output [AUX] of parameter 1 group should be set as alarm [ALM]. Alarm operation [AL] Mode Name Alarm operation Description - - No alarm output. H H AlD Deviation high, low-limit alarm H: alarm output hysteresis [ahy] PV -1 V PV 2 High-limit deviation [AlH]: et as 2, Low-limit deviation [AlL]: et as 1 If deviation between present value (PV) and setting value (V) is higher than high-limit or low-limit deviation V, alarm output turns. Alarm option [AlT] Mode Name Description AlA tandard alarm If it is an alarm condition, alarm output is. If it is a clear alarm condition, alarm output is. AlB Alarm latch 1 If it is an alarm condition, alarm output is and maintains status. AlC tandby sequence 1 AlD Alarm latch and standby sequence 1 AlE tandby sequence 2 AlF Alarm latch and standby sequence 2 First alarm condition is ignored and from second alarm condition, standard alarm operates. When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the second alarm condition, standard alarm operates. If it is an alarm condition, it operates both alarm latch and standby sequence. When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the second alarm condition, alarm latch operates. First alarm condition is ignored and from second alarm condition, standard alarm operates. When re-applied standby sequence 2 and if it is alarm condition, alarm output does not turn. After clearing alarm condition, standard alarm operates. Basic operation is same as alarm latch and standby sequence 1. It operates not only by power /, but also alarm set value, or alarm option changing. When re-applied standby sequence 2 and if it is alarm condition, alarm output does not turn. After clearing alarm condition, alarm latch operates. 1: To clear alarm, turn the power (also digital input [DI] is set as RUN/TOP [TP] and input is for pausing compressor output) or press the front key once. (press twice when buzzer is set) 2: Condition of re-applied standby sequence for standby sequence: Power, changing temperature, alarm settings, switching TOP mode to RUN mode (also digital input [DI] is set as RUN/TOP [TP] and input turns from for operation mode by releasing pause compressor output) H-2

Refrigeration Controller Functions protection This function is for preventing compressor from life cycle shortening or malfunction by overload and frequent / of compressor. As compressor protection settings, when compressor output does not, the front compressor (COMP) output indicator (green) is flashing. start-up delay time [DL] If power turns instantly from break-down or power, it delays start-up during the set time of compressor. etting range: to 6 (min) restart delay time [RDL] To prevent frequent compressor /, set compressor time after compressor turns. etting range: to 6 (min) min. operation time [T], compressor min. operation cycle [CYC] To prevent frequent compressor /, set min. operation time and min. operation cycle. etting range of compressor min. operation time: to 6 (min), etting range of compressor min. operation cycle: to 6 (min) Temp. start-up delay time min. operation cycle restart delay time min. operation cycle 2 restart delay time min. operation cycle restart delay min. operation time time (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power Comp. output V 1 1: When starting compressor, if present value (PV) is out of hysteresis range, compressor output does not turn and the compressor (COMP) output indicator is flashing during compressor start-up delay time. 2: When compressor delay is completed and it is within compressor min. operation cycle, compressor output does not turn and the compressor (COMP) output indicator is flashing. (The latest one has priority between compressor restart delay time and compressor min. operation cycle.) 3: When present value (PV) is out of hysteresis, compressor output does not turn and the compressor (COMP) output indicator is flashing during compressor restart delay time. 4: If present value (PV) is below the V, compressor output maintains status during compressor min. operation time. After compressor min. operation time, it turns. If compressor output does not turn due to compressor output condition or parameter settings for compressor protection, the compressor (COMP) output indicator is flashing. For more information about parameters for compressor prevention, refer to user manual. control when sensor break If normal temperature control is impossible due to sensor break, it controls compressor output by the set operation cycle and duty ratio to protect control object. Until error is cleared, operation cycle and duty ratio are applied repeatedly. When error is cleared, the compressor operates after completing the currently applied operation cycle and compressor restart delay time. operation cycle when sensor break [CLE] et compressor operation cycle when sensor break. et as [] and compressor output turns when sensor break. etting range: to 1 (min) duty ratio when sensor break [DUT] et compressor duty ratio when sensor break. etting range: to 1 (%) E.g.) When compressor operation cycle when sensor break [CLE] is set as 6 min and compressor duty ratio when sensor break [DUT] is set as 5%, compressor output has 6 min cycle and turns for 3 min and turns for 3 min. 2 3 4 output rate (5%) Operation cycle (6 min) Hysteresis Time (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware H-21

TF3 eries Defrost control (except 1CH, compressor output model: TF31-1 ) When operating a compressor for a long time, an evaporator and a freezer are freezing and thermal efficiency of compressor is decreased. For increasing thermal efficiency, defrost operation helps to remove frost or ice around of evaporator. et defrost cycle, time, and end temperature, etc to operate defrost (heater/hot-gas defrost). The front defrost (DEF) output indicator (green) turns during defrost output and it flashes during defrost delay operation. In case of compressor+defrost or auxiliary (alarm/evaporator-fan) output model (TF3-2 - ), defrost operation is available when defrost/auxiliary output [sda] of parameter 1 group is set as defrost [DEF]. Defrost method and operation [DEF] Parameter Defrost method Defrost operation htm gtm Heater defrost Hot-gas defrost Operates during the set defrost cycle/time htt heater defrost Operates when PV is lower than defrost end temperature during the set defrost cycle/time gtt Hot-gas defrost (only for 3CH input model (TF33- - )) Defrost cycle [DIN], defrost time [DET] et defrost cycle and time to operate defrost at every set cycle and during the set time. Defrost cycle setting range: to 24 (hour)/ to 1 (min) Defrost time setting range: 1 to 1 (min/sec) operation during defrost is varied by defrost method. In case of heater defrost, compressor output turns, and in case of hot-gas defrost, compressor output turns. Evaporator-fan operation is varied by evaporator-fan operation mode setting. In case of RTC function model (TF33-3 -R/A), defrost operates at every specific time. et real-time defrost cycle [rdi] of parameter 3 group as [] and 8 real-time defrost times are available to set. Defrost end temperature [EDT], Defrost hysteresis [dhy] (only for 3CH input model: TF33- - ) et defrost end temperature and defrost hysteresis from input sensor 2 (defrost temperature). When the measured temperature of defrost sensor is same as the set defrost end temperature, defrost operation is stopped. It is available when input sensor 2 / [2] is set as [] and defrost method and operation [DEF] is set as [htt] or [gtt]. Defrost end temperature setting range: -4 to 99 ( ) / -4 to 212 ( ) Defrost hysteresis setting range: 1 to 5 (1. to 5.) ( ) / 2 to 1 ( ) Manual defrost Execute defrost manually regardless of the set defrost cycle which consists of defrost method and operation setting. Hold the front key over 3 sec or, turn the digital input when digital input [DI] of parameter 5 group is set as [mdf] to operate defrost during the set defrost time. The front defrost (DEF) output indicator turns for 2 sec and turns for 1 sec during manual defrost. Hold the front key over 3 sec or turn the digital input during manual defrost, and the set defrost cycle re-starts. Defrost synchronization (only for synchronize defrost function model: TF33- A-, R485 communication model: TF33- A-T/A) When connecting over 2 units of TF3, defrost and compressor operation is able to synchronize via synchronize terminal/ R485 communication. It is available for synchronize defrost function model (TF33- A-), or R485 communication model (TF33- A-T/A). [etting Order] 1. Connect each other synchronize terminals or R485 communication terminals of the units which are synchronized for defrost. 2. et defrost cycle [DIN] same as among the units. (if error occurs, defrost cycle is the setting of each unit) 3. et defrost group [dgr] as 1 master unit [MA] and slave unit (s) (up to 5 units) [LA]. 4. According to defrost operation of Master, the defrost operation of slave (s) executes. (when changing the defrost parameters of master, defrost operations of slave (s) are also changed forcibly as same as the defrost operation of master via connected terminals. The defrost parameters of slave (s) are not changed.) Defrost operation by real-time defrost cycle is not able to synchronize. Defrost operation of master is prior to the compressor operation of slave. For more information about parameters for defrost operations, refer to user manual. H-22

Refrigeration Controller Evaporator-fan control (except 1CH, compressor output model: TF31-1 ) To improve the efficiency of cooling, install and control evaporator-fan at evaporator. It is available for compressor+defrost or auxiliary (alarm/evaporator-fan) output model (TF3-2 - ). Also defrost/ auxiliary output [sda] of parameter 1 group should be set as auxiliary [AUX], and auxiliary output [AUX] should be set evaporator-fan [FAN]. It is available for compressor+defrost+auxiliary (alarm/evaporator-fan) output model (TF3-3 - ). Also, auxiliary output [AUX] of parameter 1 group should be set as evaporator-fan [FAN]. Evaporator-fan operation [fty] Evaporator-fan operates by two control methods; [DEF] controls evaporator-fan by measured temperature from defrost sensor or [FAN] controls evaporator-fan by compressor/defrost operation. Evaporator-fan control temperature [ft] and hysteresis [fhy] When evaporator-fan operation [fty] is set as [DEF] controls (evaporator-fan is controlled by measured temperature from defrost sensor), and the temperature of defrost sensor is same as evaporator-fan control temperature [ft], evaporator-fan output turns. et evaporator-fan control temperature [ft] and evaporator-fan control hysteresis [fhy]. Evaporator-fan control temperature setting range: -4 to 99 ( ), -4 to 212 ( ) Evaporator-fan control hysteresis setting range: 1 to 5 (.5 to 5.) ( ), 2 to 1 ( ) Evaporator-fan operation mode [FAN] and evaporator-fan start-up delay time [pdr] When evaporator-fan operation [fty] is set as [FAN] for control by compressor/defrost operation, it is available to set [FAN] for evaporator-fan operation mode for compressor/defrost operation. Parameter EF1 EF2 EF3 EF4 EF5 Operation method When compressor operates, evaporator-fan also operates. When compressor operation is finished, evaporator-fan also operation turns. (except compressor operation for hot gas defrost) When compressor operates, evaporator-fan operates after the set evaporator-fan start-up delay time. When compressor operation is finished, evaporator-fan operation turns. (regardless of defroster operation) When power turns, evaporator-fan operates. When defroster operates, evaporator-fan stops. (regardless of compressor operation) Evaporator-fan operates only when operating compressor or defrost. Evaporator-fan stops when compressor and defroster stops. (for above zero temperature control) Evaporator-fan operates from power to power. (regardless of defroster operation of freezer. When door is open (digital input [DI] is set as RUN/TOP [TP] or door switch [dw]), evaporator-fan stops. If evaporator temperature is increased by defrost operation, warm air may flow into cooling system by evaporator-fan operation. et evaporator-fan start-up delay time [pdr] to prevent warm air inflow, and it may increase cooling efficiency. Evaporator-fan start-up delay time setting range:. to 9.59 ( min sec to 9 min 59 sec) (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse tart-up delay operation Defroster operation period Defroster operation operation Defroster operation period Defroster operation operation (N) Display Units (O) ensor Defrost cycle Defrost time Defrost end delay Defrost cycle Defrost time Defrost end delay Defrost cycle Defrost time (P) witching Mode Power upplies Defrost EF1 Evaporator-fan delay Evaporator-fan delay Evaporator-fan delay (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels EF2 () Field Network Devices EF3 (T) oftware EF4 EF5 Power : Output does not turn but the dedicated indicator flashes at the delay period (compressor, defrost, evaporator-fan). For more information about parameters for evaporator-fan control, refer to user manual. H-23

TF3 eries Digital input [DI] Digital input is available only for 3CH input model (TF33- - ). Also input sensor 3 selection [3] should be set as digital input [DI]. Parameter Function No digital input RUN/TOP TP Pauses compressor output. All output indicators turn. When digital input is, it controls normally after compressor restart delay time. Door switch dw By connecting freezer door switch and digital input contact, it controls compressor/defrost/evaporator-fan according the door status. - Digital input (door open):, defrost, evaporator-fan output turns - Digital input (door close): After 1 min, it returns the previous status of door open. (not applied compressor protection operations) Alarm occurs after the time of alarm delay after defrost/door open [AdD] of parameter 3 group. When operating compressor continuously, compressor start-up time is extended as long as the door open time. Night mode / nmd When digital input turns, night mode is active. External alarm 1 eal When digital input turns, alarm output turns forcibly. (except alarm is ) When external alarm delay time [ead] of parameter 4 group is set, alarm turns after the set time. Defrost / 1 edf When digital input turns and it is defrost operation condition, defrost output turns. Even though it is defrost operation condition, if digital input turns, defrost output turns also. Manual defrost 1 mdf When digital input turns, it executes manual defrost. 1: Except 1CH, compressor output model (TF31-1 ). Virtual temperature rate [VtR] (only for 3CH input model: TF33- - ) In case of 3CH input model (TF33- - ), input sensor 3 selection [3] of parameter 1 group is set as outlet temperature [T]. You can set virtual temperature rate. If the temperature of inlet and outlet is significantly different at freezer, virtual temperature helps to control temperature efficiently. Virtual temperature is designated by the rate of input sensor 1 (inlet temperature) and input sensor 3 (outlet temperature). There is virtual temperature calculation formula. [{1-virtual temperature rate} input sensor 1 temperature] + [virtual temperature rate input sensor 2 temperature] Virtual temperature (PV)= 1 If virtual temperature rate [VtR] is set as [], virtual temperature (PV)= input sensor 1. If virtual temperature rate [VtR] is set as [1], virtual temperature (PV)= input sensor 3 E.g.) If inlet temperature of input sensor 1 is, and outlet temperature of input sensor 3 is 1, set virtual temperature rate [VtR] as [5] and virtual temperature is 5 to control temperature. 5= etting range of virtual temperature rate: to 1 (%) Display selection [DpT] (only for 3CH input model: TF33- - ) You can select input sensor to display at present value (PV) display component in RUN mode. Parameter 1 2 3 V [{1-5} ]+ [5 1] 1 Description Displays PV of input sensor 1 (inlet temperature). Displays PV of input sensor 2 (defrost temperature). Displays PV of input sensor 3 (outlet temperature). Displays virtual temperature. Parameter mask This function is able to hide unnecessary parameters to user environment or less frequently used parameters in parameter group. You can set this in the comprehensive device management program (DAQmaster). Masked parameters are only not displayed. The setting value of masked parameters are applied. For more information, refer to DAQMaster user manual. Visit our web site (www.autonics.com) to download DAQmaster program and the user manual. Before applying mask After applying mask PA1 INT 2 3 VtR UNT PA1 INT 2 VtR The above is masking input sensor 3 selection [3], temperature unit [UNT] of parameter 1 group for 3CH input model (TF33- - ). H-24

Refrigeration Controller Parameter user group [PAU] This function is able to set the frequently used parameters to the user parameter group. You can quickly and easily set parameter settings. User parameter group can have up to 3 parameters in the comprehensive device management program (DAQMaster). For more information, refer to the DAQMaster user manual. Visit our web site (www.autonics.com) to download the DAQMaster program and the user manual. RUN mode (A) Photoelectric ensors (B) Fiber Optic ensors (C) Door/Area ensors PAU PA1 PA5 DsT HY nhy DEF DET ahy The above is setting user parameter group in the DAQMaster with delay display period [DsT] of parameter 1 group, hysteresis [HY], night mode hysteresis [nhy] of parameter 2 group, defrost method [DEF], defrost time [DET] of parameter 3 group, alarm output hysteresis [ahy] of parameter 4 group. Communication output It is for parameter setting and monitoring via external devices (PC, PLC, etc.). Interface Comm. protocol Modbus RTU Comm. speed 24, 48, 96, 192, 384 bps Connection type R485 Comm. response wait time 5 to 99 ms Application standard Compliance with EIA R485 tart bit 1-bit (fixed) Max. connection 31 units (address: 1 to 99) Data bit 8-bit (fixed) ynchronous method Asynchronous Parity bit None, Odd, Even Comm. method Two-wire half duplex top bit 1-bit, 2-bit Comm. distance Max. 8m It is not allowed to set overlapping communication address at the same communication line. Use twisted pair wire for R485 communication. Application of system organization Flashing in turn Description Troubleshooting ER 1 2 OPN When input sensor is break or sensor is disconnected. Check input sensor status. ER 1 LLL If the measured temperature of the dedicated sensor is lower than low-limit temperature among temperature setting range. If the measured temperature of the dedicated sensor is It clears when input is within the display range. ER 1 HHH higher than high-limit temperature among temperature setting range. ERR LBA Computer Error Display R232C/ UB/Wi-Fi Comm. converter B (-) A (+) R485 Even though input sensor is normal, freezer temperature does not change over 1. (1.8 ) during loop break alarm monitoring time [LBA]. Check the compressor and hold the + key at the same time for 3 sec. It clears when input is within the adequate range. 1: indicates input sensor number of error display priority which occurs error. Error display priority: ER1 (input sensor 1) ER2 (input sensor 2) ER3 (input sensor 3) ERV (virtual temperature) ERR 2: ERV (virtual temperature) is not applicable. Only for R485 communication output model. A (+) B (-) A (+) B (-) A (+) B (-) R485 DEVICE #1 Terminating resistance (1 to 12Ω) R485 DEVICE #2 R485 DEVICE #3 It is recommended to use Autonics communication converter; CM-WF48 (Wi-Fi to R485 UB wireless communication converter, sold separately), CM-U48I (UB to R485 converter, sold separately), CM-38I (R232C to R485 converter, sold separately). Please use twisted pair wire, which is suitable for R485 communication, for CM-WF48, CM-U48I and CM-38I. B (-) A (+) R485 DEVICE #31 (D) Proximity ensors (E) Pressure ensors (F) Rotary Encoders (G) Connectors/ Connector Cables/ ensor Distribution Boxes/ ockets (H) (I) Rs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / peed / Pulse (N) Display Units (O) ensor (P) witching Mode Power upplies (Q) tepper Motors & Drivers & (R) Graphic/ Logic Panels () Field Network Devices (T) oftware H-25