DATA SHEET 01 VX 200 Z Ultra-flat, central compact ventilation unit with heat recovery, flexible application, for use in apartments, offices and many more. Druckschrift-Nr: DB VX 200 Z - 03.16 OUT SUP optional OUT SUP SL EX SUP OUT EX OUT EX optional Function Ventilation Filtering free cooling Heating Night cooling freie Heating Features Compact dimension energy-saving components integrated, motorized flaps flexible application easy, variable mounting quieter and condensation-free operation effective moisture protection Customized connection possibilities as standard Special features extremely compact and flat design (approx. 200 mm) for easy installation within false ceilings volume flow constant EC fans to compensate of wind loads, air duct installations and filter contamination low weight and smart construction allow mounting with only one person Summer night cooling, (with optional bypassflap unit free heating and free cooling on desire motorized Ventomaxx flap system "ASF" for the closure of fresh- and exhaust air path frost protection of HRC optionally via secondary air mixture or optional preheating integrated humidity sensor and intelligent control for a condensation - free operation in conjunction with Secondary air mixture or with preheating; thus can be complex and cost-intensive Condensate pipes are not required false ceiling heights can thus also be reduced.
VX 200 Z COMPACT VENTILATION 02 For small to medium air requirements Ventomaxx has developed the small central air handling unit VX 200 Z for a flexible way to the varied application for the air supply of living rooms, study rooms, offices, bistros, libraries or individual floors and smaller building wings. This can be used in different regions as well as in rural regions with high plant pollen volumes and conurbations. Whisper-quiet operation ensures fresh air supply, in a very quiet environment and with the supplied accessories also during the night rest. The product series VX 200 Z is designed for the most diverse applications, it can be used in new construction or retrofitted in existing buildings. The VX 200 Z concept is a decentralized solution with the advantages of central ventilation. The prefabricated solutions allow the installation of the device even during renovation without great planning effort. It is a unique, semi-central ventilation unit for decentralized placement with central use for a shortened, hygienically optimal channel guidance. A shortened, hygienically optimal channel guidance. It can be connected to any pipe / duct system. The ventilation system ensures an optimal supply of fresh air with very good sound insulation properties, while at the same time ensuring high moisture and mold protection for all living areas. A wide range of accessories and various regulations round off the product series and guarantee a tailor-made planning for a tailor-made solution concept. VX-Control-CS with room control unit with LCD display humidity and temperature dependent step switching 2-stage preheater 1-stage reheater Door / window contact connectable Operating hours counter fault indicator Filter monitoring VX-Control-CC as VX-Control-CS but with additional CO2-dependent step switching Night cooling Party-Function holyday function Frost protection Air ways VX200 Control accessories Infrared remote control Multisensor (motion, Infrared, temperatur) WIFI-Adapter APP-control BACnet-Connection to a BMS
VX 200 Z COMPACT VENTILATION 03 Product description The VX 200 Z is a semi-central ventilation unit for supply and exhaust ventilation. It is equipped with a highly efficient heat recovery system which removes heat from the room and returns it to the supply air. Optional asseccories elektrial pre- and reheater Bypass-flap units sound insulated wall ducts (SDL) Exterior wall facade connections The "ceiling" version is specially designed for installation in false ceilings underneath the raw ceiling and the connection to a customer-supplied air distribution system. Thanks to the extremely compact and flat design with acoustically and thermally optimized housing made of EPP (extruded polypropylene), the VX200 Z is equally suitable for new construction and renovation projects. The supply air can be cleaned with a filter up to filter class F7. EC fans ensure an acoustically and energetically optimized operation. The materials used and the construction meet the hygiene requirements of VDI 6022. Control system The control is integrated in the housing. The operation is carried out by means of simple switch technology manually, automated via various room thermostats with integrated sensors for temperature, humidity, movement, and Co2, infrared remote control or APP. The bus connection to a building control system is also possible. Multiple units can be combined into a control zone and thus space-saving higher amounts of air are realized. Type comparison Unit types Equipment Monting Condensate free Bypass function (optional) VX 200 Z-0 without flaps only Wall no yes VX 200 Z-S1 VX 200 Z-S2 VX 200 Z-H0 VX 200 Z-HS1 VX 200 Z-HS2 with Secundary air function, with supply air flap with Secundary air function, with supply and exhaustair flap with preheater, without flaps with Secundary air function, with preheater, supply air flap as befor, but with supply and exhaustair flap
MOUNTING TYPES 04 Possible mounting options The VX200 can be used as a central (Z) or decentralized ventilation unit (D). For a simplified illustration of the various types of mounting, the decentralized version was shown below. Both the assembly with on-site housing, without caising (for example, in the false ceiling or in a cabinet) and in decentralized design with factory mounted casing, e.g. For free mounting on the ceiling, on balustrades, etc. Deviating special installation situations are on request also possible. We recommend the installation by means of Ventomaxx sound dampers on the wall or under the rough ceiling to avoid the transmission of body borne sound. The fixing of the VX200 Z / D is realised by means of a mounting plate on the back of the unit on a load-bearing wall or rough ceiling. When mounting in a skylight, the VX200 Z / D must be stably suspended from the ceiling and must not be pushed away from the skylight when the façade is pressed. horizontal mounting under the window vertical mounting Ceiling mounting D (dezentral) next to the window free under the ceiling in band arrangement next to the window D (dezentral) in skylight on perimeter walls under windows with a suitable covering case Z (central) in an on-site panelling Z (central) in false ceiling
CONNECTION VARIATIONS 05 Possible mounting options According to the type of mounting (horizontal, vertical or ceiling mounting) the connection possibilities are shown below. Special variants, e.g. The combination with and without connection sockets are possible in consultation The external air intake always takes place in the area of the blue border, the exhaust air outflow always within the red border. Depending on the requirements, there is a large number of connections, with or without DN125 connection. The insulation of the respective connection piece if necessary is provided by the customer,. There are 4 different connection openings in the external air box, one of which can be used as an external air connection and a second as an optional secondary air connection if flaps are installed in the unit. If the flaps are installed, the outside and the secondary air connections must be arranged at right angles to each other. The type of connection is always selected for the side of the outside air intake, the exhaust air outlet is already mirrored in the factory. horizontal mounting vertical mounting ceiling mounting FOL Supply FOL EXH S FOL without connecting piece without connecting piece HA1 HA2 VA1 VA2 without connecting piece DA1 DA2 with connecting piece HK1 HK2 with connecting piece VK1 VK2 with connecting piece DK1 DK2 DK3 DK4 The main connections are marked with dark gray arrows. The optional connectors are marked with light gray arrows.
TECHNICAL DATA 06 Technical Data VX 200 Z Series / device version Delivery air volume Fan power consumption max. air volume Bemessungsspannung Mains frequency I (max.) VX 200 Z 3 3 30 m/h up to 180 m/h 3 at 120 m/h ~ 79 W 3 up to 200 m/h 230 V 50 Hz 4 A protection class IP 00 Subject to technical modifications. Pictures and information without obligation. ambient temperature 10 40 C Heat recovery rate 91 % Heat exchanger design Filter (G4; F7 optional) Housing room side Housing dimensions HxWxD Cross -counterflow AirStatic G3 Connector connection diameter DN 125 Wight Fitting location We would be pleased to provide further data and drawings on request. EPP-foam/ black ca. 204 x 1077 x 560 mm ca. 15 kg Wall/Ceiling * Leistungsangaben beziehen sich auf 5 Haupt-Stufen, weitere Stufen sind als * Performance data refer to 5 main stages, further stages ** Messflächenschalldruckpegel, can be selected as intermediate Lpf stages Messung im Abluftbetrieb ** Measuring surface sound pressure level, Lpf measurement in exhaust mode Rosenheim Notice Ventomaxx International GmbH Herzog Georg Platz 4 84028 Landshut Phone Fax WEB E-Mail +49 2361 499450 +49 2361 499456 www.ventomaxx-international.com info@ventomaxx-international.com