TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Similar documents
TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

TREO SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

Service Manual & Installation Manual

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

Кондиционеры Mitsubishi Heavy

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

DAEWOO SERVICE MANUAL DSC-1245FL DSC-1285FL DSC-1285FLH. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No CONTENTS

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

Floor-Standing Type(E Series)

Service Manual. Inverter air conditioner TAC-18CHSA/JAI. Models CONTENTS. 1. Important Notice

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

MSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-FH25VE2 MSZ-FH35VE2 MSZ-FH50VE2 INDOOR UNIT. No. OBH623. Models

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

SERVICE MANUAL INDOOR UNIT. No. OBH788

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE MANUAL INDOOR UNIT

Technical Manual of AUX Air Conditioner CONTENTS. Product Specification...1. Refrigeration Diagram...3. Introductions of Installation.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

1 Summary and features. Service Manual. Model QSVMI-09A QSVMI-12A QSVMI-18A

Operating Functions Temperature Parameters

Air Conditioner CONTENTS CS-E9DKEW CU-E9DKE CS-E12DKEW CU-E12DKE. Order No: MAC C2

BTU Units WORKING PROGRAM MANUAL

SRK20ZFX-S, 25ZFX-S, 35ZFX-S, 50ZFX-S

Service Manual & Installation Manual

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE INDOOR UNIT. No. OBH623. Models SPLIT-TYPE AIR CONDITIONERS

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SERVICE MANUAL MS-GF20VA MS-GF25VA MS-GF35VA MS-GF50VA MS-GF60VA MS-GF80VA INDOOR UNIT. No. OBH621 REVISED EDITION-A. Models

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Part 3 Troubleshooting

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

II PCV1 Features

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE MANUAL MSZ-HM09NA MSZ-HM12NA MSZ-HM15NA MSZ-HM18NA MSZ-HM24NA INDOOR UNIT. No. OBH746 REVISED EDITION-B. Models

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

DESIGN & TECHNICAL MANUAL

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

Air Conditioner CONTENTS

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Ductless Split Air Conditioner

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

Mobile Type Air Conditioner

ENG. Service manual SPLIT WALL MOUNTED TYPE: KASI K26Vi, K26Vo KASI K35Vi, K35Vo KASI K50Vi, K50Vo KASI K70Vi, K70Vo

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

DESIGN & TECHNICAL MANUAL

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )

1. OPERATION RANGE 1 2. SPECIFICATION 2 3. INSTALLATION 6 4. ELECTRICAL DATA 7 5. CONTROL MODE TROUBLE SHOOTING CHECKING COMPONENTS 27 8

FLOOR CONSOLE / UNDER CEILING DUAL type

C&H NORDIC Commercial 4 SERVICE MANUAL

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models

Room Air Conditioner CONTENTS CS-E18CKE CU-E18CKE CS-E21CKE CU-E21CKE. Order No. MAC C2

CASSETTE type INVERTER MULTI AIR CONDITIONER

3. INDOOR UNIT OPERATION

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MSZ-DM25VA - E1, ER1 MSZ-DM35VA - E1, ER1 INDOOR UNIT. No. OBH750. Models

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

SPLIT TYPE AC AND MULTI SPLIT AC SERVICE MANUAL

WORKING PROGRAM. Heating dehumidifying cooling T 27

Air Conditioner Service Manual

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

Ductless Split Air Conditioner

SERVICE MANUAL KFR-7002GW

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

2. Mobile Air-conditioner (KY-32)

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

DESIGN & TECHNICAL MANUAL

YC ON-OFF SERIES. Service Manual

Transcription:

TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 6 4. WIRING DIAGRAM 4 5. EXPLOSION VIEW 20 6. PARTS LIST 28

IMPORTANT NOTICE This service manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use. The information, specifications and parameter are subject to change due to technical modification or improvement without any prior notice. The accurate specifications are presented on the nameplate label. How to order spare parts To have your order filled promptly and correctly, please furnish the following information:. Model No. with Indoor or Outdoor 2. No. in the Explosion View 3. Part Name 4. The quantity you ordered 2

Technical Specifications Model No. TAC-07CS/K TAC-07CHS/K TAC-09CS/K TAC-09CHS/K Type Cooling Only Heating Pump Cooling Only Heating Pump Control type Remote Remote Remote Remote Rated cooling capacity Btu/h 7,000 7,000 9,000 9,000 Rated heating capacity Btu/h N/A 7,500 N/A 9,500 EER for cooling Btu/h.w 9.6 9.6 9.6 9.6 COP for heating W/W N/A 2.8 N/A 2.8 Moisture removal Liters/h 0.8 0.8 0.8 0.8 High db(a) 36 36 36 36 Indoor noise level at cooling Med. db(a) 32 32 32 32 Low db(a) 29 29 29 29 Outdoor noise level db(a) 50 50 50 50 Electrical Data Power supply Voltage Range Rated current Rated input 220-240V~/50Hz V Cooling A 4.2 4.2 4.2 4.2 Heating A N/A 4. N/A 4. Cooling W 895 895 900 900 Heating W N/A 880 N/A 880 Refrigerating System Refrigerant/Charge Gram R22/700g R22/700g R22/700g R22/700g Type Rotary Rotary Rotary Rotary Compressor Model ------------------ ----------------- ------------------ ------------------ LRA A ------ ------- ------ ------ MFG ----------------- ----------------- ---------------- ----------------- Evaporator Louver fin and Grooved tube type ( 7) Condenser Corrugated fin and Grooved tube type ( 9.53) Expansion device Capillary tube Defrosting system Microcomputer controlled reverse system Fan System Indoor air circulation m 3 /h 430 430 430 430 Indoor fan type Cross flow Cross flow Cross flow Cross flow Indoor fan speed H/M/L Cooling rpm 000/950/900 000/950/900 000/950/900 000/950/900 Heating rpm N/A 970/900/800 N/A 970/900/800 Dry rpm 900 900 900 900 Sleep rpm 650 650 650 650 Indoor fan motor output W 2 2 2 2 Outdoor air circulation m 3 /h --- --- --- --- Outdoor fan type Propeller fan Propeller fan Propeller fan Propeller fan Outdoor fan speed rpm 895 895 895 895 Outdoor fan motor output W 3 3 3 3 Connections Refrigerant coupling Flare type Connecting Pipe Gas Inches 3/8 3/8 3/8 3/8 Liquid Inches /4 /4 /4 /4 Connecting Wiring Size Core number Drainage Pipe O.D 6mm Others Suitable area m 2 2~9 2~9 2~9 2~9 Net dimensions Indoor mm 70 250 79 70 250 79 70 250 79 70 250 79 (W x H x D) Outdoor mm 600 500 232 600 500 232 600 500 232 600 500 232 Net weight Indoor kg 7.5 7.5 7.5 7.5 Outdoor kg 25 25 25 25 Packing dimensions Indoor mm 805 325 270 805 325 270 805 325 270 805 325 270 (W x H x D) Outdoor mm 745 352 542 745 352 542 745 352 542 745 352 542 Gross weight Indoor kg 0 0 0 0 Outdoor kg 28 29 28 29 Loading Capacity 40 /40 HC 32/280/38 32/280/38 32/280/38 32/280/38 3

Model No. TAC-2CS/K TAC-2CHS/K TAC-8CS/K TAC-8CHS/K Type Cooling Only Heating Pump Cooling Only Heating Pump Control type Remote Remote Remote Remote Rated cooling capacity Btu/h 2,000 2,000 8,000 8,000 Rated heating capacity Btu/h N/A 2,800 N/A 9,000 EER for cooling Btu/h.w 9.2 9.2 8.8 8.8 COP for heating W/W N/A 2.65 N/A 2.65 Moisture removal Liters/h.0.0.0.5 High db(a) 38 38 42 42 Indoor noise level at cooling Med. db(a) 36 36 40 40 Low db(a) 32 32 36 36 Outdoor noise level db(a) 52 52 58 58 Electrical Data Power supply Voltage Range Rated current Rated input 220-240V~/50Hz V Cooling A 5.6 5.6 9.6 9.6 Heating A N/A 5.9 N/A 9.0 Cooling W 270 270 200 200 Heating W N/A 335 N/A 970 Refrigerating System Refrigerant/Charge Gram R22/870g R22/870g R22/700g R22/700g Type Rotary Rotary Rotary Rotary Compressor Model ------------------ ----------------- ------------------ ------------------ LRA A ------ ------- ------ ------ MFG ----------------- ----------------- ---------------- ----------------- Evaporator Louver fin and Grooved tube type ( 7) Condenser Corrugated fin and Grooved tube type ( 9.53) Expansion device Capillary tube Defrosting system Microcomputer controlled reverse system Fan System Indoor air circulation m 3 /h 530 530 800/850 800/850 Indoor fan type Cross flow Cross flow Cross flow Cross flow Indoor fan speed H/M/L Cooling rpm 50/060/900 50/060/900 300/200/00 300/200/00 Heating rpm N/A 50/060/900 N/A 300/200/00 Dry rpm 900 900 840 840 Sleep rpm 650 650 900/000 900/000 Indoor fan motor output W 2 2 25 25 Outdoor air circulation m 3 /h --- --- --- --- Outdoor fan type Propeller fan Propeller fan Propeller fan Propeller fan Outdoor fan speed rpm 860 860 820 820 Outdoor fan motor output W 55 55 90 90 Connections Refrigerant coupling Flare type Connecting Pipe Gas Inches /2 /2 /2 /2 Liquid Inches /4 /4 /4 /4 Connecting Wiring Size Core number Drainage Pipe O.D 6mm Others Suitable area m 2 6~28 6~28 30~40 30~40 Net dimensions Indoor mm 770 250 79 770 250 79 036 33 204 036 33 204 (W x H x D) Outdoor mm 700 255 540 700 255 540 760 255 540 760 255 540 Net weight Indoor kg 8.0 8.0 4 4 Outdoor kg 3 32 42 43 Packing dimensions Indoor mm 863 325 270 863 325 270 03 395 280 03 395 280 (W x H x D) Outdoor mm 803 380 595 803 380 595 863 376 605 863 376 605 Gross weight Indoor kg 0 0 9 9 Outdoor kg 34 35 44 45 Loading Capacity 40 /40 HC /238/276 /238/276 90/88/28 90/88/28 4

Model No. TAC-24CS/K TAC-24CHS/K Type Cooling Only Heating Pump Control type Remote Remote Rated cooling capacity Btu/h 24,000 24,000 Rated heating capacity Btu/h N/A 26,000 EER for cooling Btu/h.w 9.0 9.0 COP for heating W/W N/A 2.55 Moisture removal Liters/h 2.2 2.2 High db(a) 47 47 Indoor noise level at cooling Med. db(a) 44 44 Low db(a) 40 40 Outdoor noise level db(a) 58 58 Electrical Data Power supply Voltage Range Rated current Rated input 220-240V~/50Hz V Cooling A 3 3 Heating A N/A 3.8 Cooling W 2600 2600 Heating W N/A 2800 Refrigerating System Refrigerant/Charge Gram R22/2500g R22/2500g Type Rotary Rotary Compressor Model ------------------ ----------------- LRA A ------ ------- MFG ----------------- ----------------- Evaporator Louver fin and Grooved tube type ( 7) Condenser Corrugated fin and Grooved tube type ( 9.53) Expansion device Capillary tube Defrosting system Microcomputer controlled reverse system Fan System Indoor air circulation m 3 /h 000 000 Indoor fan type Cross flow Cross flow Indoor fan speed H/M/L Cooling rpm 300/200/00 300/200/00 Heating rpm N/A 300/200/00 Dry rpm 000 000 Sleep rpm 000 000 Indoor fan motor output W 35 35 Outdoor air circulation m 3 /h --- --- Outdoor fan type Propeller fan Propeller fan Outdoor fan speed rpm 850 850 Outdoor fan motor output W 0 0 Connections Refrigerant coupling Flare type Connecting Pipe Gas Inches 5/8 5/8 Liquid Inches 3/8 3/8 Connecting Wiring Size Core number Drainage Pipe O.D 6mm Others Suitable area m 2 35~48 35~48 Net dimensions Indoor mm 036 33 204 036 33 204 (W x H x D) Outdoor mm 890 307 660 890 307 660 Net weight Indoor kg 6 6 Outdoor kg 57 60 Packing dimensions Indoor mm 03 395 280 03 395 280 (W x H x D) Outdoor mm 990 405 705 990 405 705 Gross weight Indoor kg 20 20 Outdoor kg 63 65 Loading Capacity 40 /40 HC 66/42/62 66/42/62 Note: The technical specifications is only reference. 5

Operation Details Remote controller Remote controller The remote controller transmits signals to the system. ON/OFF button Used to start and stop operation when pressed. 5 2 8 4 FEEL COOL DRY FAN HEAT SLEEP TIMER MODE SLEEP TIMER ON TMIER OFF AUTO HIGH MID LOW SWING FAN SWING ON/OFF 3 7 6 2 3 4 5 6 TIMER button Used to select TIMER operation. UP button (TOO COOL button) Used to increase the set room temperature and time. DOWN button (TOO WARM button) Used to decrease the set room temperature and time. SLEEP button Used to set or cancel sleep mode operation. VANE control button Used to adjust airflow direction. 7 8 FAN SPEED control button Used to select the indoor fan motor speed: Auto, High, Mid and Low. MODE button Used to select the type of operation mode: Feel, Cooling, Dry, Fan and Heating(Only for Heat Pump). Note: Each mode and relevant function will be further specified in following pages. Remote Control The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of Heat or Cool on LCD of the remote controller. User can preset the remote controller type depending on the air conditioner type you have purchased as follows: Press any button when the arrowhead flashes on the front of Cool, Cooling Only is set. Press any button when the arrowhead flashes on the front of Heat, Heat Pump is set. If you don t press any button within 0 seconds, the remote controller is preset as Heat Pump automatically. Note : If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller. 6

Elctronic Controller. Safety Control () Time Delay Safety Control TCL Air Conditioner Service Manual 3 minutes delay for compressor---the compressor is ceased for 3minutes to balance the pressure in the refrigeration cycle in order to protect the compressor. 2 minutes delay for 4-way valve---the 4-way valve is ceased for 2 minutes to prevent the refrigerant-gas abnormal noise when the HEATING operation is OFF or switch to the other operation mode. 20 seconds delay for indoor fan--- When the assistant thermistor turns off, the indoor fan operates in low speed for 20 seconds to release the heat of indoor unit. (2) Indoor Pipe Temperature Sensor Frost Prevention Control When the indoor pipe temperature sensor reads 0 or below for 5 minutes, the indoor pipe temperature sensor frost prevention control starts. The compressor and outdoor fan stop and indoor fan operates at high speed for 3 minutes. After that, if the indoor pipe temperature sensor reads less than 5 this control prolonged until the indoor pipe temperature sensor reads 5 or more. (3) High Temperature Protection Control During HEATING operation, the outdoor fan motor and compressor are controlled by the indoor pipe temperature to prevent the high temperature of compressor. Outdoor fan OFF: 52 Outdoor fan ON:48 Compressor OFF:62 Compressor ON:48 2. I Feel Mode Operation () When the I Feel mode is selected, the operation mode and initial set temperature are determined by the initial room temperature at start-up of the operation except to turn off the air conditioner and operates it again. (2) If the mode is change to I Feel mode from other mode, the I Feel mode doesn t operate until compressor stop for more than 3 minutes. Mode Initial room temperature Initial set temperature COOLING DRY HEATING for Heat Pump Type FAN for Cooling Only Type 26 or more 20 to 25 Less than 20 24 8 23 In the I Feel mode, when the controller receives the up or down single of temperature, the set temperature can adjust by upper or lower. The biggest you can adjust by 2 upper or lower. 3. COOLING Mode Operation () When the COOLING mode is selected without setting temperature, the system will set the set temperature at 26 automatically with the AUTO FAN speed. (2) When selecting the COOLING mode operation, the system will operate according to the setting by the remote controller and the operation is as following: 7

Room Temp. Set TEMP. Set TEMP. Time More than 2 min More than 2 min More than 2 min More than 2 min More than 2 min Indoor Fan Set Speed Set Speed Set Speed Set Speed Set Speed Compressor ON OFF ON OFF ON Outdoor Fan ON OFF ON OFF ON 4. DRY Mode Operation () The system for DRY operation used the same refrigerant circle as the cooling circle. (2) When the system operates in DRY mode,at first it operates in cooling mode at 8 for 3 minutes, and then, the system operates in cooling mode with low speed that regards the temperature of the room temperature sensor reads decrease 2 as the set temperature. During the course of this, the fan speed setted operation is failing but the vane motor can be controlled. 5. HEATING Mode Operation (Only available for Heat Pump) () When the HEATING mode is selected without setting temperature, the system will set the temperature at 23 automatically with the AUTO FAN speed. (2) When selecting the HEATING mode operation, the system will operate according to the setting by the remote controller and the operation is as following: Set Temp. Set Temp. Room Temp. Time More than 2 min More than 2 min More than 2 min More than 2 min More than 2 min Compressor ON OFF ON OFF ON Outdoor fan ON OFF ON OFF ON (3) In HEATING mode, the indoor fan motor is controlled by Cold Air Prevention Control. (4) Cold Air Prevention Control The function is intend to prevent cold air from being discharged when the heating operation starts or when defrosting. The indoor fan speed will be controlled as following: The vane angle is at the angle C(00 ). Indoor Pipe Temperature 34 30 27 25 23 OFF UL Set Speed UL OFF UL 8

(5) Defrost Defrosting of the outdoor heat exchange is controlled by the microprocessor with detection by the defrost sensor. Defrost starting conditions When the conditions of a) or b) is satisfy, the defrosting operation starts. a) Under the heating operation, the compressor cumulative operation time exceeds 50 minutes and the temperature of the outdoor defrost sensor reads lower than 8 b) Under the heating operation, the compressor cumulative operation time exceeds 50 minutes, if the indoor pipe temperature sensor reads lower than 40 continuously for 2minutes. Note: If haven t the outdoor pipe temperature sensor that use the condition b) to defrost, against use the condition a). Defrost terminating conditions When the condition c) or d) is satisfy, the defrosting operation stops. c) The outdoor defrost sensor reads 5 or more. d) The defrosting time exceeds 0 minutes. Defrosting time chart Outdoor Fan ON OFF ON Revering Valve ON OFF ON Compressor Relay ON OFF ON OFF ON 39S 5S Defrost Count MAX 2min 9S 5S t (6) Assistant Thermistor Function Assistant thermistor is add the thermitor of the electricity to rise the heating capacity automatically not effected by the signal of the remote controller about assistant thermistor ON/OFF buttons. ) When the condition all of A~G are satisfy, the assistant thermistor opens. A. Under the heating operation, the compressor operates over than 3 minutes. B. The indoor fan operates in normal. C. The system operates not in defrosting. D. The assistant thermistor turn off over than 30 seconds. E. The set temperature is 3 or more than the room temperature. F. The room temperature sensor reads less than 22. G. The indoor pipe temperature reads 43 or less. 2) When one of the conditions of A~E is satisfy, the assistant thermistor is off. A. The compressor is turned off. B. The room temperature sensor reads 24 or more. C. The indoor pipe temperature sensor reads 48 or more. D. The indoor fan is stopped. 6. FAN mode operation 9

The indoor fan motor always turns on at the set speed and the vane motor turns on at the set fattle. 7. 4-way Valve contro HEATING ON COOLING/DRY OFF The 4-way valve reverses for 5 seconds right before start-up of the compressor as following chart: COOLING/DRY HEATING Compressor 4-way Valve Outdoor Fan 5s 5s 8. SLEEP mode When the SLEEP button is pressed, the SLEEP mode is selected as following: The indoor fan speed is set at the super low speed. When selecting COOLING/DRY operation with SLEEP mode, the set temperature will be raised by hour later and by 2 2 hour later. When selecting HEATING operation with SLEEP mode, the set temperature will be dropped by hour later and 2 2hour later. After the System operates in SLEEP mode for 8 hours, it will stop automatically. 9. Fan motor control () Rotational frequency feedback control The indoor fan motor is equipped with a rotational frequency sensor, and outputs signal to the microprocessor to feedback the rotational frequency. Comparing the current rotational frequency with the target rotational frequency, the microprocessor adjusts fan motor electric to make the current rotational frequency close to the target rotational frequency. With this control, when the fan speed is switched, the rotational frequency changes smoothly. (2) When the rotational frequency feedback signal has not output for 5 seconds (or when the microprocessor can t detect the signal for 5 seconds), the fan motor is regarded locked-up. Then the electric current to the fan motor is shut off. 0 seconds later, the electric current is applied to the fan motor again. During the fan motor lock-up, the POWER indicator lamp flashes on and off to show the fan motor abnormality. 0. Auto Fan Speed Control () When the auto fan speed is selected, the indoor fan motor speed is automatically controlled by the room temperature and the set temperature. (2) In COOLING mode, the indoor fan motor operates as following: Fan Speed Hi Me Lo Room temperature minus set temperature: 2 4 (3) In HEATING mode, the indoor fan motor operates as following; Fan Speed Hi Mi Lo Room temperature minus set temperature 2 4 0

. Auto Vane Operation control () Vane motor drive The unit is equipped with a stepping motor for the vane. The rotating direction, speed, and angle of the motor are controlled by pulse signal transmitted from indoor microprocessor. (2) Positioning The vane is once pressed to the vane stopper below to confirm the standard position and then set to the desired angle. The positioning is decided as follows: When the ON/OFF button is pressed. When the vane control is change from AUTO to MANUAL. When the SWING is finished. When the test run starts. When the power supply turns ON. (3) The auto vane changes as follows by pressing the VANE CONTROL button. (4) VANE AUTO mode In vane auto mode, the microprocessor automatically determines the vane angle and operation to make the optimum room-temperature distribution. (5) SWING mode When presses the SWING button, the vane swings. 2. TIMER Operation () To activate the air conditioner at the desire time, follow the procedure specified below(the remote control and air conditioner are switched off): Press the Timer button. Select the desired mode by pressing the Mode button. Select the desired temperature by pressing the button (only possible when the cool or heat mode is selected). Select the ventilator speed (low, medium or high) or automatic mode (only possible when the feel, Cool or Heat mode is selected) by pressing the Fan button. The ventilator always operates in the Auto mode when the Dry mode is selected. Select Swing or no Swing by pressing the Swing button. Press the Timer button ( h flashes). Use the button to select the time at which the air conditioner must activate (between 0 and 0 hours can be set at every half hour-between 0 and 24 hours can be set at every hour). Press the Timer button ( h stops flashing) and the preset time appears in the display. Press the Timer button again to delete the selected data from the memory. Note: If no buttons are pressed during the programming of the timer function, the remote control will switch off automatically are after 0 seconds. (2) To switch the air conditioner off at the desired time, follow the procedure specified below (the remote control and air conditioner are switched off): Press the Timer button. Use the button to select the time at which the air conditioner must deactivate (between 0 to 0 hours can be set at every half hour-between 0 to 24 hours can be set at every hour). Press the Timer button ( h stops flashing), and the preset time will appear in the display. Press the Timer button again to delete the selected data from the memory. Note: If no buttons are pressed during the programming of the timer function, the remote control will switch off automatically after 0 seconds. Note: if h is flashing and you press the ON/OFF/RUN button once, the preset temperature will appear in

the display. You can now adjust the temperature with the button. Press the Timer button again to display the time, which can now also be adjusted. If the Timer button is pressed again, the data is stored and the remaining time(that the air conditioner will be in operation) will appear in the display. Pressing the ON/OFF/RUN button instead of the Timer button deactivates the remote control. Note: check that the TIMER INDICATOR on the indoor unit lights up after the timer has been set. Press the Timer function to check the settings in the display. 3. EMERGENCY-TEST Operation When the EMERGENCY Operation switch is pressed once, COOLING mode is selected and if in 3 seconds the EMERGENCY Operation switch is pressed again, HEATING mode is selected. Then pressed once again, the unit is switch off. When the remote controller is missing, has failed or the batteries run down, press the EMERGENCY Operation switch on the front of the indoor unit. The unit will start. The first 30 minutes of operation will be the test run operation. The operation is for servicing. The indoor fan runs at high speed and the system is in continuous operation. The thermostat is ON and the timer is reset to normal. After 30 minutes of test run operation the system shifts to AUTO COOLING/HEATING mode, and the indoor fan runs in automatic speed. The operation continues unit the EMERGENCY operation switch is pressed or a button on the remote controller is pressed, the normal operation will start. NOTE: Do not press the EMERGEMCY Operation switch during normal operation. 4.AUTO RESTART Function (Option) When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan speed are memorized by the indoor electric control PCB. The AUTO RESTART function sets to work the moment power has restored after power failure. Then, the unit will restart automatically. 5. Failure Display and Handling a) The failure of the resistance of heat sensitive: When the resistance of heat sensitive reads the temperature is lower than 50 or over than 0 that judge the heat sensitive is bad. b) The Outdoor Protection Control When the system checks the signal from outdoor of the voltage is 0V, the system delay second to start for check the signal again, if checks the signal of the voltage is 0V too, that the system not to star, or operates on normal. c) Failure Display When the controller is failure, the buzzer will voice long for three times, and displays the failure from the failure lamp. d) Failure Code If have the digital pipe that display the failure code for digital pipe, or display for the run lamp. Type of failure The lamp flash Display of digital pipe The failure of room temperature sensor Once/cycle E The failure of indoor pipe temperature sensor Twice/cycle E2 Outdoor protection function 5 times/cycle E5 The failure of indoor fan 6 times/cycle E6 e) Failure Handling When the room temperature sensor or the indoor pipe temperature sensor is failure, the system will be shut off, the compressor will be OFF, and the outdoor fan and the indoor fan will be OFF. The system doesn t receive the signal of remoter controller except the signal of shut off it. When the failure eliminated, the controller can operate in normal mode. before this, presses the ON/OFF to start the system, and it will operate in COOLING or HEATING for 30 minutes, and follows shut off. During 2

this, it displays the failure and the protection is failing. You must be give the electric again to operate it. In the failure, you can operate the FAN mode. When the outdoor protects in the COOLING or DRY, the outdoor unit stops, the indoor fan operates in set speed ; and in the HEATING, the outdoor unit stops, the assistant thermistor stops, the indoor fan operates in cold air prevention control. The system doesn t receive the signal of remoter controller except the signal of shut off it. When the system check the voltage is 220V and the delay control is finished, it operates at normal again. When the indoor fan motor is failure, the compressor is stopped, the outdoor fan and indoor fan is stopped and display the failure. The system doesn t receive the signal of remoter controller except the signal of shut off it. f) Display Of The Control In the display board the lamp from left is the POWER lamp (Red), the SLEEP lamp(yellow), the TIMER lamp(yellow), the RUN lamp(green). (7) When gives the control electric, the buzzer voices a long for 0.3 second per cycle. 3

Wiring Diagram TCL Air Conditioner Service Manual Mode No.: TAC-07CS/K, TAC-09CS/K, TAC-2CS/K INDOOR UNIT transformer Display PCB TH Room Temp.Sensor TH2 Pipe Temp.Sensor CN CN2 CN8 CN6 CN5 PCB P2- P2-2 N.O. 4 K COM 3 CN4 CN3 Power supply evaporator N Outdoor Unit Vane Motor M M protector Fan Motor Indoor Unit OUTDOOR UNIT N White Black Compressor CM C R(M) White S Red Protector Compressor Capacitor Orange Fan Capacitor M Indoor Unit Outdoor Unit Fan Motor 4

WIRING DIAGRAM MODEL: TAC-07CHS/K,TAC-09CHS/K, TAC-2CHS/K INDOOR UNIT: Transformer Display PCB TH Room Temp. sensor TH2 Pipe Temp. sensor CN8 CN6 CN CN2 PCB P2- P5 P4 P2-2 NO 4 K COM 3 CN5 CN4 CN3 YLW/GRN Yellow Red YLW/GRN Evaporator N 3 2 Power Supply YLW/GRN Yellow Red N 3 2 Outdoor Unit M Vane Motor M Protecter Fan Motor Indoor Unit OUTDOOR UNIT 4-way Vane Compressor (White) Red Yellow 2 3 N White Black Protecter Orange CM C R(M) S Red M Compressor Capacitor Fan Capaciter Indoor Unit Outdoor Unit Fan Motor 5

Mode No.: TAC-8CS/K INDOOR UNIT To The Outdoor L N Transformer N N L White PCB AC(N) N.O Relay COM Display PCB 2 3 4 5 4 3 2 5 4 3 2 Fan Motor FM SM SM Vane Motor Room Temp. Sensor Pipe Temp. Sensor OUTDOOR UNIT N White Black Compressor CM C White R(M) S Red Protector Compressor Capacitor Orange Fan Capacitor M Indoor Unit Outdoor Unit Fan Motor 6

WIRING DIAGRAM MODEL: TAC-8CHS/K INDOOR UNIT: To The Outdoor Unit Red Yellow White Red Yellow To O.P.T P4 P5 AC(N) P2- P3 P Relay CN8 Display PCB PCB CN2 CN CN3 P9- P9-2 CN5- CN5-2 CN7 CN6 Transformer FM Fan Motor SM SM Vane Motor Room Temp. Sensor Pipe Temp. Sensor OUTDOOR UNIT: (White) Red Yellow 2 3 N Valve Coil White Black CN7 JUNCTION TH3 JUNCTION Indoor Unit Outdoor Unit Compressor CM C R(M) S Red Inside/Outside Compressor Protecter Capacitor Orange M Fan Motor Fan Capaciter 7

Mode No.: TAC-24CS/K INDOOR UNIT Transformer To Outdoor Unit White N L White N.O COM AC(N) Relay PCB 2 3 4 5 4 3 2 5 4 3 2 FM Fan Motor SM SM Vane Motor Display PCB Room Temp. Sensor Pipe Temp. Sensor OUTDOOR UNIT White To Power Supply To Indoor Unit N L L N White Red White Fan Capacitor C Yellow Red FM Relay Fan Motor White Red Conpressor Capacitor C2 C S R CM Conpressor Motor 8

TCL Air Conditioner Service Manuel WIRING DIAGRM MODEL: TAC-24CHS/K INDOOR UNIT: FM SM SM OUTDOOR UNIT: YLW/GRN White Red Yellow YLW/GRN To Power Supply To Indoor Unit 2 3 N L L N White Red Valve Coil YLW/GRN O.P.T Junction Fan Capacitor C Relay Yellow Red FM Fan Motor Compressor Capacity White YLW/GRN Red C2 C S R FM Compressor Motor 9

TAC Air Conditioner Service Manual EXPLOSION VIEW Model: TAC-07CS/K, TAC-07CHS/K, TAC-09CS/K, TAC-09CHS/K, TAC-2CS/K, TAC-2CHS/K INDOOR UNIT: 3 2 6 5 4 28 29 7 27 8 26 9 0 25 24 3 2 23 22 2 20 4 9 7 6 5 8 20

INDOOR UNIT TAC-8CS/K, TAC-8CHS/K, TAC-24CS/K, TAC-24CHS/K 2 30 5 4 3 28 29 9 0 2 8 7 6 27 26 25 24 23 22 2 20 4 3 9 8 7 5 6 2

EXPLOSION VIEW Model: TAC-07CS/K, TAC-09CS/K OUTDOOR UNIT: TCL Air Conditioner Service Manual 7 6 5 4 3 2 8 9 25 24 23 22 2 20 0 2 3 4 5 6 7 8 9 22

EXPLOSION VIEW Model : TAC-2CS/K, TAC-8CS/K OUTDOOR UNIT TCL Air Conditioner Service Manual 9 8 7 6 5 4 3 2 0 26 25 24 23 22 2 2 3 4 5 6 7 8 9 20 23

EXPLOSION VIEW Model : TAC-24CS/K OUTDOOR UNIT 8 7 6 5 4 3 2 26 25 24 9 23 22 2 20 9 8 0 2 3 4 5 6 7 24

EXPLOSION VIEW Mode: TAC-07CHS/K, TAC-09CHS/K OUTDOOR UNIT: 7 6 5 4 3 2 29 8 28 27 9 26 25 24 23 22 2 20 0 2 3 4 5 6 7 8 9 9

EXPLOSION VIEW MODEL: TAC-2CHS/K, TAC-8CHS/K INDOOR UNIT: 8 7 6 5 4 3 2 30 9 29 28 0 27 26 25 24 23 22 2 2 3 4 5 6 7 8 9 20 20

EXPLOSION VIEW MODEL: TAC-24CHS/K OUTDOOR UNIT: 8 7 6 5 4 3 2 9 29 28 27 26 25 24 23 22 2 20 0 2 3 4 5 6 7 8 9 27

Parts List Indoor Unit- TAC-07CS/K, TAC-09CS/K No. Part No. Part Name Q ty Remark 080030003 Installation Plate 2 2025003 Base 3 07002007 Cross Fan 4 0700000 Bearing Mount 5 202300 Evaporator 6 07025002 Water Drainage Assembly 7 07032005 Vertical Vane Assembly 2 8 07025004 Face Frame 9 0703202 Screw Cover 2 0 09032002 Display PCB 0703205 Display PCB Box 2 0702500 Display PCB Cover 3 07025006 Air Filter 2 4 0702580 Front Panel 5 7020038 Power Supply Cord 6 07025003 Vane 7 0700008 Drainage Hose 8 070040004 Cable Clamp 9 70200039 Terminal 20 07025009 Terminal Fixing Board 2 090250602 Main PCB 22 0703203 Electrical Box 23 700200 Vane Motor 24 07303020 Sensor Holder 25 70030047 Indoor Motor 26 070320 Indoor Motor Cover 27 7024000 Transformer 28 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 29 0703200 In And Out Pipe Fixer 30 0900007 Remote Controller 3 073030303 Remote Controller Supporter Not shown in Explosion 3 90060007 Indoor Carton view 32 90060008 Left Foaming 33 90060009 Right Foaming 28

Parts List Indoor Unit- TAC-07CHS/K, TAC-09CHS/K No. Part No. Part Name Q ty Remark 080030003 Installation Plate 2 2025003 Base 3 07002007 Cross Fan 4 0700000 Bearing Mount 5 202300 Evaporator 6 07025002 Water Drainage Assembly 7 07032005 Vertical Vane Assembly 2 8 07025004 Face Frame 9 0703202 Screw Cover 2 0 09032002 Display PCB 0703205 Display PCB Box 2 0702500 Display PCB Cover 3 07025006 Air Filter 2 4 0702580 Front Panel 5 7020044 Power Supply Cord 6 07025003 Vane 7 0700008 Drainage Hose 8 070040004 Cable Clamp 9 70200040 Terminal 20 07025009 Terminal Fixing Board 2 090250202 Main PCB 22 0703203 Electrical Box 23 700200 Vane Motor 24 07303020 Sensor Holder 25 70030047 Indoor Motor 26 070320 Indoor Motor Cover 27 7024000 Transformer 28 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 29 0703200 In And Out Pipe Fixer 30 0900007 Remote Controller 3 073030303 Remote Controller Supporter Not shown in Explosion 3 90060007 Indoor Carton view 32 90060008 Left Foaming 33 90060009 Right Foaming 29

Parts List Indoor Unit- TAC-2CS/K No. Part No. Part Name Q ty Remark 080030008 Installation Plate 2 2032007 Base 3 07002006 Cross Fan 4 0700000 Bearing Mount 5 2032060 Evaporator 6 2032008 Water Drainage Assembly 7 07032005 Vertical Vane Assembly 2 8 07032007 Face Frame 9 0703202 Screw Cover 2 0 09032002 Display PCB 0703205 Display PCB Box 2 0703200 Display PCB Cover 3 07032009 Air Filter 2 4 0703250 Front Panel 5 7020047 Power Supply Cord 6 07032004 Vane 7 0700008 Drainage Hose 8 070040004 Cable Clamp 9 70200039 Terminal 20 07025009 Terminal Fixing Board 2 090320702 Main PCB 22 0703203 Electrical Box 23 700200 Vane Motor 24 07303020 Sensor Holder 25 70030047 Indoor Motor 26 070320 Indoor Motor Cover 27 7024000 Transformer 28 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 29 0703200 In And Out Pipe Fixer 30 0900007 Remote Controller 3 073030303 Remote Controller Supporter Not shown in Explosion 3 9006000 Indoor Carton view 32 90060008 Left Foaming 33 90060009 Right Foaming 30

Indoor Unit - TAC-2CHS/K No. Part No. Part Name Q ty Remark 080030008 Installation Plate 2 2032007 Base 3 07002006 Cross Fan 4 0700000 Bearing Mount 5 2032060 Evaporator 6 07032003 Water Drainage Assembly 7 07032005 Vertical Vane Assembly 2 8 07032007 Face Frame 9 0703202 Screw Cover 2 0 09032002 Display PCB 0703205 Display PCB Box 2 0703200 Display PCB Cover 3 07032009 Air Filter 2 4 0703250 Front Panel 5 7020047 Power Supply Cord 6 07032004 Vane 7 0700008 Drainage Hose 8 070040006 Electrical Box Cover 9 070040004 Cable Clamp 20 70200040 Terminal 2 07025009 Terminal Fixing Board 22 700200 Vane Motor 23 09032003 Main PCB 24 004000 Sensor Holder 25 0703203 Electrical Box 26 70030047 Indoor Motor 27 070320 Indoor Motor Cover 28 7024000 Transformer 29 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 30 0703200 In And Out Pipe Fixer 3 0900007 Remote Controller Not shown in Explosion 3 073030303 Remote Controller Supporter view 32 9006000 Indoor Carton 33 90060005 Left Foaming 34 90060006 Right Foaming 3

Indoor Unit- TAC-8CS/K No. Part No. Part Name Q ty Remark 08003000 Installation Plate 2 230900 Base 3 07002004 Cross Fan 4 0700000 Bearing Mount 5 2309005 Evaporator 6 2309002 Water Drainage Assembly 7 07309006 Vertical Vane Assembly 2 8 0730900 Face Frame 9 073090 Screw Cover 3 0 09309002 Display PCB 07309026 Display PCB Box 2 0730902 Air Filter 2 3 070500205 Front Panel 4 0730903 Display PCB Cover 5 07309032 Electrical Box Cover 6 7020049 Power Supply Cord 7 07309008 Vane A 8 07309025 Vane B 9 0700008 Drainage Hose 20 070040003 Cable Clamp 2 700200 Vane Motor 22 70200038-39 Terminal 2 23 08309008 Terminal Fixing Board 24 07303020 Sensor Holder 25 09309020 Main PCB 26 07309020 Indoor Motor Cover 27 70030045 Indoor Motor 28 0930902 Electrical Box 29 7309007 Transformer 30 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 3 0900007 Remote Controller Not shown in Explosion 3 073030303 Remote Controller Supporter view 32 90060003 Indoor Carton 33 9006009 Left Foaming 34 90060020 Right Foaming 35 90060002 Middle Pasteboard Supporter 36 9006002 Middle Foaming Supporter 32

Indoor Unit- TAC-8CHS/K No. Part No. Part Name Q ty Remark 08003000 Installation Plate 2 0730900 Base 3 07002004 Cross Fan 4 0700000 Bearing Mount 5 2309006 Evaporator 6 2309002 Water Drainage Assembly 7 07309006 Vertical Vane Assembly 2 8 0730900 Face Frame 9 073090 Screw Cover 3 0 09309002 Display PCB 07309026 Display PCB Box 2 0730902 Air Filter 2 3 070500205 Front Panel 4 0730903 Display PCB Cover 5 07309022 Electrical Box Cover 6 7020049 Power Supply Cord 7 07309008 Vane A 8 07309025 Vane B 9 0700008 Drainage Hose 20 070040003 Cable Clamp 2 2 700200 Vane Motor 22 70200040 Terminal 2 23 08309008 Terminal Fixing Board 24 004000 Sensor Holder 25 09052009 Main PCB 26 07309020 Indoor Motor Cover 27 70030045 Indoor Motor 28 0930902 Electrical Box 29 7309007 Transformer 30 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 3 0900007 Remote Controller 3 073030303 Remote Controller Supporter Not shown in Explosion 32 90060003 Indoor Carton view 33 9006009 Left Foaming 34 90060020 Right Foaming 35 90060002 Middle Pasteboard Supporter 36 9006002 Middle Foaming Supporter 33

Indoor Unit- TAC-24CS/K No. Part No. Part Name Q ty Remark 08003000 Installation Plate 2 0730900 Base 3 07002004 Cross Fan 4 0700000 Bearing Mount 5 20700205 Evaporator 6 2309002 Water Drainage Assembly 7 07309006 07309007 Vertical Vane Assembly A Vertical Vane Assembly B 8 0730900 Face Frame 9 073090 Screw Cover 3 0 09309002 Display PCB 07309026 Display PCB Box 2 0730902 Air Filter 2 3 070500205 Front Panel 4 0730903 Display PCB Cover 5 07309032 Electrical Box Cover 6 7020030 Power Supply Cord 7 07309008 Vane A 8 07309025 Vane B 9 0700008 Drainage Hose 20 070040002 Cable Clamp 2 700200 Vane Motor 22 70200042 Terminal 23 08309008 Terminal Fixing Board 24 07303020 Sensor Holder 25 09070002 Main PCB 26 07309020 Indoor Motor Cover 27 70030048 Indoor Motor 28 0930902 Electrical Box 29 7309007 Transformer 30 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 3 0900007 Remote Controller 3 073030303 Remote Controller Supporter Not shown in Explosion 32 90060003 Indoor Carton view 33 9006009 Left Foaming 34 90060020 Right Foaming 35 90060002 Middle Pasteboard Supporter 36 9006002 Middle Foaming Supporter 34

Indoor Unit- TAC-24CHS/K No. Part No. Part Name Q ty Remark 08003000 Installation Plate 2 0730900 Base 3 07002004 Cross Fan 4 0700000 Bearing Mount 5 20700205 Evaporator 6 2309002 Water Drainage Assembly 7 07309006 Vertical Vane Assembly 2 8 0730900 Face Frame 9 073090 Screw Cover 3 0 09309002 Display PCB 07309026 Display PCB Box 2 0730902 Air Filter 2 3 070500205 Front Panel 4 0730903 Display PCB Cover 5 07309022 Electrical Box Cover 6 7020030 Power Supply Cord 7 07309008 Vane A 8 07309025 Vane B 9 0700008 Drainage Hose 20 070040003 Cable Clamp 2 2 700200 Vane Motor 22 7020004 Terminal 2 23 08309008 Terminal Fixing Board 24 07309027 Sensor Holder 25 090700204 Main PCB 26 07309020 Indoor Motor Cover 27 70030048 Indoor Motor 28 0930902 Electrical Box 29 7309007 Transformer 30 7023000 Pipe Temp. Sensor & Room Temp. Sensor Assembly 3 0900007 Remote Controller 3 073030303 Remote Controller Supporter 32 90060003 Indoor Carton 33 9006009 Left Foaming 34 90060020 Right Foaming 35 90060002 Middle Pasteboard Supporter 36 9006002 Middle Foaming Supporter Not shown in Explosion view 35

Outdoor Unit- TAC-07CS/K, TAC-09CS/K No. Part No. Part Name Q ty Remark 0835090 Grille Optional 2 08005006 Top Cover 3 20250304 Condenser 4 08005005 Outdoor Motor Supporter 5 70040062 Outdoor Motor 6 070030006 Propeller Fan 7 08005002 Left Plate 8 08005008 Front Plate 9 08005009 Fan Guard 0 2025032 Capillary Assembly 0000008 Compressor and its Accessories 2 202506 Discharge Pipe 3 2352408 Suction Pipe 4 2025030 Base 5 2020008 Two-way Valve 6 08005004 Valve Supporter 7 20300 Three-way Valve 8 08005003 Right Plate 9 0735230 Electrical Box Cover 20 08002000 Electrical Parts Box 2 08000002 Capacitor Strip 22 7000003 Compressor Capacitor 23 700003 Fan Motor Capacitor 24 7020009 Terminal 25 070040002 Cable Clamp( 7) 26 9007004 Base Carton Not shown in the Explosion 27 90070008 Cabinet Carton view. 28 9007006 Base Foaming 29 9007005 Cover Forming 36

Part List Outdoor Unit- TAC-07CHS/K, TAC-09CHS/K No. Part No. Part Name Q ty Remark 0835090 Grille 2 08005006 Top Cover 3 20250304 Condenser 4 08005005 Outdoor Motor Supporter 5 70040062 Outdoor Motor 6 070030006 Propeller Fan 7 08005002 Left Plate 8 08005008 Front Plate 9 08005009 Fan Guard 0 007008 Compressor and its Accessories 23530404 Suction Pipe 2 23530407 Three-way Valve Connecting Pipe 3 23530405 Discharge Pipe 4 200002 4-way Valve Assembly 5 23530406 Condenser Connecting Pipe 6 2353044 Base 7 08005003 Right Plate 8 2020008 Two-way Valve 9 08005004 Valve Supporter 20 20300 Three-way Valve 2 0735230 Electrical Box Cover 22 07004000 Cable Clamp 23 070040002 Cable Clamp 24 70200020 Terminal 25 700003 Fan Motor Capacitor 26 700004 Compressor Capacitor 08000002 Capacitor Strip 28 08002000 Electrical Parts Box 29 2025050 Capillary Assembly 30 9007004 Base Carton Not shown in the Explosion 3 9025020 Cabinet Carton view. 32 9007006 Base Foaming 33 9007005 Cover Forming 37

Outdoor Unit- TAC-2CS/K No. Part No. Part Name Q ty Remark 080050025 Grille Optional 2 08032005 Top Cover 3 2032006 Condenser 4 080050004 Outdoor Motor Supporter 5 70040058 Outdoor Motor 6 07003006 Propeller Fan 7 08005000 Left Grille Supporter 8 080050007 Left Grille 9 0803203 Front Plate 9 0803202 Fan Guard 0 20320705 Capillary Assembly 0070004 Compressor and its Accessories 2 20320707 Discharge Pipe 3 20320708 Suction Pipe 4 2032003 Base 5 202006 Two-way Valve 6 080050003 Valve Supporter 7 203002 Three-way Valve 8 080050002 Right Plate 9 0735503 Electrical Box Cover 20 08000006 Capacitor Strip 2 070040003 Cable Clamp( 8) 22 7020009 Terminal 23 7000003 Compressor Capacitor 24 700000 Fan Motor Capacitor 25 08002000 Electrical Parts Box 26 9007004 Base Carton Not shown in the Explosion 27 90070008 Cabinet Carton view. 28 9007006 Base Foaming 29 9007005 Cover Forming 38

Outdoor Unit- TAC-2CHS/K No. Part No. Part Name Q ty Remark 080050025 Grille Optional 2 08032005 Top Cover 3 2035020 Condenser 4 080050004 Outdoor Motor Supporter 5 70040058 Outdoor Motor 6 07003006 Propeller Fan 7 08005000 Left Grille Supporter 8 080050007 Left Grille 9 0803203 Front Plate 0 0803202 Fan Guard 0070004 Compressor And It Accessories 2 2032002 Suction Pipe 3 2032003 Three-way Valve connecting Pipe 4 203205 Discharge Pipe 5 200002 4-way Vane Assembly 6 2032004 Condenser connecting Pipe 7 2032003 Base 8 080050002 Right Plate 9 202006 Two-way Valve 20 080050003 Valve Supporter 2 203002 Three-way Valve 22 0735503 Electrical Box Cover 23 07004000 Cable Clamp( 6) 24 070040002 Cable Clamp( 7) 25 70200020 Terminal 26 7000032 Fan Motor Capacitor 27 7000003 Compressor Capacitor 28 08000006 Capacitor Strip 29 08002000 Electrical Parts Box 30 203205 Capillary Assembly 3 9007007 Base Carton Not shown in the Explosion 32 90500302 Cabinet Carton view. 33 9007009 Base Foaming 34 9007008 Cover Forming 39

Outdoor Unit- TAC-8CS/K No. Part No. Part Name Q ty Remark 080050026 Grille Optional 2 0800500 Top Cover 3 2050009 Condenser 4 080050004 Outdoor Motor Supporter 5 70040059 Outdoor Motor 6 07003002 Propeller Fan 7 08005000 Left Grille Supporter 8 080050007 Left Grille 9 080050009 Front Plate 0 0803202 Fan Guard 23590202 Capillary Assembly 2 00000 Compressor and its Accessories 3 205002 Discharge Pipe 4 2050020 Suction Pipe 5 2050006 Base 6 202006 Two-way Valve 7 080050003 Valve Supporter 8 203002 Three-way Valve 9 080050002 Right Plate 20 0735503 Electrical Box Cover 2 08000006 Capacitor Strip 22 070040003 Cable Clamp( 8) 23 7020009 Terminal 24 7000007 Compressor Capacitor 25 7000027 Fan Motor Capacitor 26 08002000 Electrical Parts Box 27 90070020 Base Carton Not shown in the Explosion 28 90070002 Cabinet Carton view. 29 90070022 Base Foaming 30 9007002 Cover Forming 40

Part List Outdoor Unit- TAC-8CHS/K No. Part No. Part Name Q ty Remark 08453050 Grille Optional 2 0800500 Top Cover 3 2050035 Condenser 4 080050004 Outdoor Motor Supporter 5 70040059 Outdoor Motor 6 07003002 Propeller Fan 7 08005000 Left Grille Supporter 8 080050007 Left Grille 9 080050009 Front Plate 0 0803202 Fan Guard 00000 Compressor And It Accessories 2 2050007 Suction Pipe 3 2050009 Three-way Valve connecting Pipe 4 2050008 Discharge Pipe 5 200003 4-way Vane Assembly 6 205000 Condenser connecting Pipe 7 2050006 Base 8 080050002 Right Plate 9 202006 Two-way Valve 20 080050003 Valve Supporter 2 203002 Three-way Valve 22 0735503 Electrical Box Cover 23 07004000 Cable Clamp( 6) 24 70040003 Cable Clamp( 8) 25 70200020 Terminal 26 7000027 Fan Motor Capacitor 27 7000007 Compressor Capacitor 28 08000006 Capacitor Strip 29 08002000 Electrical Parts Box 30 20700203 Capillary Assembly Not show in the explosion 3 7456802 Outdoor Sensor 3 90070020 Base Carton 32 90070002 Cabinet Carton 33 90070004 Upper Forming 34 9007002 Base Forming 4

Outdoor Unit- TAC-24CS/K No. Part No. Part Name Q ty Remark 08453050 Grille Optional 2 084530504 Top Cover 3 2070002 Condenser 4 08453050 Outdoor Motor Supporter 5 70040063 Outdoor Motor 6 07003007 Propeller Fan 7 08453056 Left Plate 8 08453054 Front Plate 9 08453055 Fan Guard 0 2070003 Suction Pipe 2456809 Base 2 0006003 Compressor and its Accessories 3 084530503 Right Plate 4 084530502 Valve Supporter 5 20200 Two-way Valve 6 203003 Three-way Valve 7 074530503 Electrical Box Cover 8 08000004 Capacitor Strip 9 0740608 Cable Clamp 20 70200037 Terminal 2 7000007 Compressor Capacitor 22 7000030 Fan Motor Capacitor 23 745680 AC Contactor 24 08456802 Electrical Parts Box 25 2070002 Discharge Pipe 26 207000 Capillary Assembly 27 90070003 Base Carton Not shown in the Explosion 28 9007003 Cabinet Carton view. 29 90070004 Cover Carton 42

Part List Outdoor Unit- TAC-24CHS/K No. Part No. Part Name Q ty Remark 08453050 Grille Optional 2 084530504 Top Cover 3 207002 Condenser 4 08453050 Outdoor Motor Supporter 5 70040063 Outdoor Motor 6 07003007 Propeller Fan 7 08453056 Left Plate 8 08453054 Front Plate 9 08453055 Fan Guard 0 0006003 Compressor And It Accessories 20700203 Capillary Assembly 2 2070025 Suction Pipe 3 20700205 Three-way Valve connecting Pipe 4 20700203 Discharge Pipe 5 20000 4-way Vane Assembly 6 20700206 Condenser connecting Pipe 7 2456809 Base 8 20200 Two-way Valve 9 084530502 Valve Supporter 20 203003 Three-way Valve 2 084530503 Right Plate 22 074530503 Electrical Box Cover 23 0740608 Cable Clamp 24 70200036 Terminal 25 08000006 Capacitor Strip 26 7000007 Compressor Capacitor 27 7000030 Fan Motor Capacitor 28 08000004 Electrical Parts Box 29 745680 AC Contactor 30 7456802 Outdoor Sensor 3 90070003 Base Carton Not show in the explosion 32 9007003 Cabinet Carton 33 90070004 Upper Carton 43