Central Battery & Central Monitoring System

Similar documents
front cover Techno Fire & Safety Co. LLC

AMCXC.S CENTRAL AND MONITORING STATION BURGLAR ALARM SYSTEM UNITS

Advanced FireAlarm Panel 1-4Loop

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Room Temperature Sensors

ModBus DE-1 INSTALLATION AND USER MANUAL

Reliably Advanced Extinguishing Control

UL Online Certifications Directory

OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity

NBSXC.S4019 Household Burglar Alarm System Units. Household Burglar Alarm System Units

APPLICATION DATA SHEET

APPLICATION DATA SHEET

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

CV-350 TCP/IP Access Control System. System Overview

AMCXC.S7513 Central and Monitoring Station Burglar Alarm System Units. Central and Monitoring Station Burglar Alarm System Units

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

ELECTRONIC SOUNDER STROBE Model : AVD-C407

HTC-915-CONT. Heat-Trace Control system

Specification for On-Line UPS Battery Monitoring and Data Management System

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

DESCRIPTION. 42 mm. 125 mm

Why Hart XL Aspirating Smoke Detection?

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Fire control panel detect 3004 plus and accessories

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Danfoss gas detection Controller unit

I/A Series 716C 1/16 DIN Temperature Controller

Corrigo E. Second generation which contains all applications and languages

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

The EN54 Part 2 & 4 Fire System

Reliably Advanced Extinguishing Control

Detection, Protection, Innovation

EMERGENCY LIGHTING SYSTEM

Constant climate chambers

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Med Touch Master Alarm

UNC100 Integra Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

On the job around the clock 24/7: Fire detection systems

Tri-Tech Medical Inc.

Danfoss gas detection units

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Alarm module for leak detection with webserver

IndigoVision Alarm Panel. User Guide

Process & TeMPerATUre UniversAl input DigiTAl MeTers

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

RAYCHEM NGC-30 COMPONENTS

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

FLAME ITEM PART NO CLIENT REF. NO. DESCRIPTION DESIGNATION MANUFACTURER CLASS UL FILE NO.

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

CAN unit for Analog Sensors

FIRElux Emergency Lighting

General Routing Interface

EMERGENCY LIGHT SERIES

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Process Alarm Module RTA 421

HRX3000. Technical Manual

AirFlow Sensor for Dry Contact connection

600 Range Dialer Installation Manual. Version 1.0

Multi-Gas-Controller MGC2

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Networked Access Control Panel. Installation Guide

Panel Mounted Fault Annunciator Series

Control System Structure

Intelligent Addressable Fire Alarm System

The EN54 Part 2, 4 and 13 Fire System

Outdoor Temperature Sensor

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

SECTION LIGHTING CONTROLS

SUPREMATouch. Modular Fire & Gas Detection System

General Specifications

CAREL heatersteam Electric Element Steam Humidifiers

Constant climate chambers

Process Alarm Solutions

DES - DYNAMIC ESCAPE SYSTEM TUNNEL EMERGENCY LIGHTING VER.17.1

Combined CAN Sensor Unit Temperature, Humidity and Smoke

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

EC-BOS-602/616 AX Security

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

C-Bus Four Channel General Input Unit Installation Instructions

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

The Commercial LED Lighting Specialist

Panel Mounted Fault Annunciator Series

REMOTE MONITORING AND ALARM SYSTEM

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Danfoss gas detection unit Type GD Heavy Duty

RACK MONITORING SYSTEM - RAMOS Ultra

ECO PDU PE7214/PE7216/PE7324/PE7328

HRX Technical Manual. Version 1.2

IntesisBox BACnet/IP Server - Notifier ID3000 series

Two-Channel Gas Controller

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

3M Oldham MX 43 Controller

Transcription:

We hereby certify that Quality Management System of 1081 Budapest, Kun utca 4. fszt. 7. complies with requirements of in the following scope: Wholesale, retail trade and export of security products and systems. Manufacture of emergency lighting, siren and power supply units Certificate No.: 100-0799 Date: 27.08.2018 Valid until: 27.08.2021 EAC code: 29 Bujtás Gyula CEO Budaörs, 27.08.2018 Tanúsítjuk, hogy az 1081 Budapest, Kun utca 4. fszt. 7. min ségirányítási rendszere megfelel az szabvány követelményeinek, a következ alkalmazási területeken: Biztonságtechnikai termékek és rendszerek kis- és nagykereskedelme, valamint exportja. Vészvilágítás, sziréna és tápegység gyártása A tanúsítvány száma: 100-0799 Dátum: 2018.08.27. Érvényes: 2021.08.27. EA kód: 29 Bujtás Gyula vezérigazgató Budaörs, 2018.08.27. Page Bottom See General Information for Emergency Lighting and Power Equipment EML LIGHTING KFT KUN UTCA 4 FSZT. 7 1081 BUDAPEST, HUNGARY E499742 Trademark and/or Tradename: Addressable Graphical Symbol Sign (Running Man), Model(s) EML-6014, EML-6017 Addressable graphical symbol signs, Running man, Model(s) EML-414, EML-515 Addressable unit equipment, Model(s) EML-313F, EML-313R, EML-4014/F, EML-4014/R, EML-6016, EML-613, EML-616, EML-813, EML-816 Emergency Lighting System Control Panel, Model(s) EML-601, EML-602, EML-603, EML-604, EML-605, EML-606 Emergency lighting system control panels, Model(s) EML-100, EML-200, EML-300, EML-400 Emergency lighting system control panels, AC controls, Model(s) EML-AC Emergency lighting system control panels, Addressable modules, Model(s) EML-AM Last Updated on 2018-08-03 Questions? Print this page Terms of Use Page Top 2018 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2018 UL LLC". Page Bottom See General Information for Exit Fixtures EML LIGHTING KFT KUN UTCA 4 FSZT. 7 1081 BUDAPEST, HUNGARY E499743 Trademark and/or Tradename: Addressable Graphical Symbol Light (Running Man), Model(s) EML-6024 Last Updated on 2018-08-03 Questions? Print this page Terms of Use Page Top 2018 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2018 UL LLC". Central Battery & Central Monitoring System Company Profile EML Lighting Ltd. Safety products and exit luminaries are designed, manufactured and supplied in both conventional and addressed systems. The addressed systems offer a number of advantages; after installation and commissioning, the systems can be maintained cost-effectively. The unique addressing of the lights provides easy supervision for maintenance and all the necessary information regarding the functioning are shown on the control panel s LCD. The product range includes of EML lights with Central Battery (CB), EML lights with Main Battery (MB), EML accessories (Addressing Module, Control Module, Body suspending Hangers, Interfaces for logical settings), Main Units (Control Panels). The products have been manufactured, mastered over the years of acquired knowledge base and perfected to comply to their applications under the approvals of related international standards. Today s events around the world make it increasingly necessary to have security systems at all times, accuracy and immediate response to life-threatening events are basic needs. In the event of a simple power outrage or fire, buildings must be emptied in the shortest term possible and must be eliminated. It is vitally important to make the escape safe, fast, and secure with exit signs visible from any point in the place to show the passageways. The Central Battery, Main Battery and control panels are interfaced at high technological essence to keep the sign on at all times to assist evacuation of persons in short time. CERTIFICATE TANÚSÍTVÁNY FTBR.E499742 Emergency Lighting and Power Equipment Emergency Lighting and Power Equipment FWBO.E499743 Exit Fixtures Exit Fixtures EML Lighting Kft. EML Lighting Kft. BS EN ISO 9001:2015 MSZ EN ISO 9001:2015 12 Techno Fire & Safety Co. LLC

The main unit (control panel) directly, or through a sub center controls supervises the operation of the luminaries connected to the panel system. The control Panel is designed to checks the presence of the working supply voltage in the split circuit of the building with the help of the control modules incorporated in the control panel. When required as per the safety requirements, the control panel switches the lighting units to emergency mode. CENTRAL MONITORING SYSTEM EML Addressable Emergency Lighting Control Panel EML-100, EML-200, EML-300, EML-400 (MB/CB) Number of devices Voltage Range Communication Network Luminaire control Web server function Store events Gateway management Software Menu Display Output Ingress protection Certificates 99/198/297/396 pcs. of devices (99 devices per line) 120-240V AC-DC 50-60Hz, 700W/line 120-240V AC line communication, UDP, MODBUS communication TCP/IP network The luminaires can be controlled individually Status and event display on the website 2000 events / control panel 254 panels / system Graphic software Multi-language menu, Touch monitor 3,5 4 Relay output IP44 CE, UL EML brand main unit controls the operation of the luminaries in CB system. The control units come in two versions viz., according to UL or DIN standards respectively. They work in both AC and DC modes and as well from 120V to 240V supply. The units are designed to adapt to any UPS (not only EML s central battery) for Power input source. They can handle up to a maximum of 594 addressed devices, or as per DIN standard, 18x20 devices; the load consumed is maximum 12kW/unit. The device can be set easily with the help of its 7 display. CENTRAL BATTERY SYSTEM EML Addressable Emergency Lighting Control Panel EML-601, EML-602, EML-603, EML-604, EML-605, EML-606 Number of devices Voltage Range Communication Network Luminaire control Web server function Store events Gateway management Software Menu Display Output Ingress protection Certificates 99/198/297/396/495/594 pcs. of devices (99 devices / line) or as per DIN 18 lines, (20 devices / line) 120-240V AC-DC 50-60 Hz, 2000W/line 120-240V AC line communications, UDP, MODBUS, FIRE ALARM (option) RS485 The luminaires can be controlled individually Status and event display on the website 2000 events / control panel 64 panels / system Graphic software Multi-language menu, Touch monitor 7" 4 Relay output IP20 CE, UL Techno Fire & Safety Co. LLC 13

EML-613 /slave/mb OR EML-613 / slave/cb Type EML-616 / slave/mb OR EML-616 / slave/cb Type EML-813 / slave/mb OR EML-813 / slave/cb Mounting : Concealable Type EML-816 / slave/mb OR EML-816/ slave/cb Mounting : Concealable EML-515 / slave/mb OR EML-515 / slave/cb IP Rating : IP42 Viewing Dist. 25Mtr. EML-414 / slave/mb OR EML-414 / slave/cb / Concealable IP Rating : IP42 EML-6014 / slave/mb OR EML-6014 / slave/cb Mounting : Ceiling EML-6017 / slave/mb OR EML-6017 / slave/cb Mounting : Sidewall EML-6016 / slave/mb OR EML-6016 / slave/cb Mounting : Sidewall / Ceiling 14 Techno Fire & Safety Co. LLC

EM L-4014 R/F/slave/MB OR EM L-4014 R/F/slave/CB Mounting : Recessed Light : 4 I Rating : IPA Main Supply : 120-240 V AC 50-60hz EML-313 R/F/slave/MB OR EML-313 R/F/slave/CB Mounting : Ceiling Surface / Recessed IP Rating : IP20 EML SH 1 (Interface for 99 pcs luminaires) EML-AC (230V/PF control module) Input (for phase monitoring) Current drain Power Max device/panel Closing resistor (active with jumper) Connection (to panel) RS bus max distance Cable Battery (powering the device) : AC 230V / pot free power control : 11mA : 2.5VA : 32 pcs (uniquely addressed)q : For closing the RS485 line on the last AC control : RS485 : 1200m (without repeat) : Should use twisted pair cabling : 6V 80mAh EML - SLAVE (Communication unit for slave/cb, slave/mb, slave/con/mb, slave/con/cb) EML-AM (MB/CB) Addressing module Input current Max capacity Ambient temperature Terminals Functions : AC/DC120-240V60/50Hz : 100W : 100C-300C : 2.5 m2 single wire or 1.5 m2 stranded and soldered : Phase monitoring Battery status monitoring - Addressed device status monitoring EML FUG2 / FUG5 (Light body suspensory system, 1.5 mm stainless steel, with eyelets, 2 m / 5 m long) Techno Fire & Safety Co. LLC 15

Schematic for addressable emergency and exit lights with main battery. Recommended cable diameters depending on distance are 3x1.5 mm2 or 3x2.5 mm2 Schematic for addressable emergency and exit showing lights with central battery. Recommended cable diameters depending on distance are 3x1.5 mm2 or 3x2.5 mm2 16 Techno Fire & Safety Co. LLC