Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

Similar documents
Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

Fire Door Maintenance Guide.

30 Minute Firedoor. 30 minute firedoor

Technical Bulletin CE marking: from 1st July 2013

fire resistance testing

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

Regulatory Reform (Fire Safety) Order 2005

Fire Protection. Intumescent fire and smoke seals for door assemblies

C/S Fire Rated Door Edge Protection Product Range FD60

Loss Prevention Standard

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 646 EUROSPEC ARCHITECTURAL HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED

CI/SfB (32.5) Ro8 (K2) ACOUSTIC SEALING SYSTEMS FOR DOOR ASSEMBLIES

Loss Prevention Standard

F O C U S D O O R C L O S E R S

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

CERTIFICATE OF APPROVAL No CF 418 PROMAT UK LTD

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

Specification, installation & maintenance of fire doors: Technical Note 2

CERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

CERTIFICATE OF APPROVAL No CF 111 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 5118 ASSA ABLOY LTD

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

dhf General Information Automated Gates Guidance for enforcement bodies

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

EVOLUTIONS FIRE PROTECTION

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Guidance Note No 19/1. CE Marking windows and doorsets

Timber Doorsets For Every Application. ASSA ABLOY, the global leader in door opening solutions

Agrément Certificate 92/2841 website: Product Sheet 1

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

CERTIFICATE OF APPROVAL No CF 5527 TALLERES DE ESCORIAZA S.A.U.

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Testing coated fabrics

Fire doors are a lifeline. When properly fitted and properly cared for they give vital minutes for people to safely escape from fire and smoke.

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

The Route to Third Party Certification

The Association for Specialist Fire Protection

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

IDD 033C - Fire door sets

TECHNICA DORMA. Controlled. d Door Closing. Closerss. appended hereto:

Life Safety and Fire Resistant Glazing Systems

Electromagnetic Locking Devices

25 th November Title:

Australian Standard. Security screen doors and security window grilles AS AS 5039

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

Controlled Door Closing Devices

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Easy-action Door Closer DORMA TS83

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Panic and Emergency Exit Devices

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online.

Practice Guidee No.1. of the

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

Australian/New Zealand Standard

Third Party Certification:

Mechanically operated locks and locking plates

DOOR SETS. Versatile with a range of options, they can be tailored to suit your needs.

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

CERTIFICATE OF APPROVAL No CF 5179 LORIENT POLYPRODUCTS LIMITED

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

Transcription:

.1 Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

Falcon Panel Products Ltd Clock House Station Approach Shepperton Middlesex TW17 8AN Strebord Technical Manual (Version 9.1) Validation of Data against Global Assessment Reports The specifications of all pages within this technical manual which are marked with a Q have been checked against the following Global Assessment reports and verified to be correct: Chilt/A02066 Rev L Chilt/A02067 Rev H Chilt/A09104 Rev B Chilt/A10152 Rev A Strebord 44 30 minute doorsets Strebord 54 60 minute doorsets Strebord 44 30 minute panelled doorsets Strebord 54 60 minute panelled doorsets The data contained in the Q-Mark designated sections of this manual can therefore be utilised in the following ways, provided that all of the assessments listed above are still valid, and have not been updated, revised or withdrawn: 1) By a fabricator who does not hold 3 rd party certification under the Exova BM TRADA Q- Mark scheme to support the demonstration of conformance of their specification to the global assessment reports listed above. Whilst this may be acceptable for building regulations compliance, this does not infer 3 rd party certification in any way, and the final product will not be covered by 3 rd party certification in this instance. 2) By a Q-Mark Fire Door Scheme Certified Fabricator in support of their certification provided that the fabricator has these Global Assessments included in their scope of certification. Supplementary data also contained in this manual (in Appendices) which does not hold the Q symbol has not been approved by Exova BM TRADA. This therefore may not be used in support of 3 rd party certification under the Exova BM TRADA Q-Mark fire door scheme. 24 th March 2016 23rd March 2019 Signed on behalf of Validation Date: Expiry Date: Exova BM TRADA

v9.1 Strebord Technical Manual - Version 9.1 Door Core About this Manual: This Technical Manual has been prepared as part of Falcon Panel Products Ltd. commitment to users of Strebord. This Manual is intended for use as guidance and to assist in the identification of the standards and requirements applicable to the manufacture of doors and doorsets. Whereas reference is made to Building Regulations - England and Wales this is for guidance only. Separate building regulations apply in Scotland, Northern Ireland and in the Irish Republic. Local bye laws may also apply. The users of Strebord should determine applicable regulations by reference to the particular project specifications. This manual also suggests methods for the handling and use of Strebord NOTE 1: The contents of this manual shown with the icon or labelled as Q-Mark are approved by reference to current fire test / assessment data for the manufacture of fire doors under the Q-Mark third party accreditation scheme administered by BM TRADA. For the content of this manual that is not marked with this symbol, the information is advisory and may not apply for fire door applications. NOTE 2: To maintain the Q-Mark status, the doorset manufacturer must be a member of the Q-Mark third party accreditation scheme. For various reasons, users of Strebord may wish to be members of alternative third party accreditation schemes. Falcon Panel Products Ltd. provide support for users of Strebord by making base test data available to alternative UKAS approved third party accreditation providers for this purpose. Queries relating to the use of Strebord should be referred to: Head Office: Falcon Panel Products Ltd., Clock House, Station Approach, Shepperton, Middlesex TW17 8AN Tel: +44 (0) 1932 256580 Fax: +44 (0) 1932 230268 Because of an ongoing commitment to develop Strebord, the information contained in this manual may be amended without notice. Please visit our web site at: www.falconpp.co.uk for updates recording the technical progress of Strebord. NOTE: This manual is for guidance only. Falcon Panel Products Ltd. do not accept any liability in tort or otherwise resulting from any failure of Strebord based products to satisfy any project performance requirements or for any damage howsoever caused resulting from the use of Strebord. Falcon Panel Products Ltd. are members of Architectural & Specialist Door Manufacturers Association 175 Certificate No. FRTD427/01 Certificate Number 006/020 PEFC/16-37-92 Membership No. 064056 Copyright Approved Component Supplier Doortech 2000 The mark of responsible forestry Strebord carries FSC certification, subject to availability Strebord carries PEFC certification, subject to availability World rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including but not limited to photocopy, photograph, magnetic or other record, without the prior agreement and written consent of the publisher.

v9.1 Introducing Strebord is a multi layer particle board that is manufactured to the exacting standards demanded by Falcon Panel Products Ltd. Strebord has been designed to provide a reliable core material for the manufacture of wooden doors to meet a wide range of performance requirements. Strebord provides for ease of handling and use and can be converted into wooden doors to satisfy almost unlimited design requirements. Strebord is specifically designed for internal use, but can also be used as a core material for external applications. About Q Mark The Q Mark Fire Door Scheme is a third party accreditation scheme designed to prove the worth of a manufacturer s products. Certificate Number 006/020 Manufacturers are required to have their products type tested and assessed to cover a product range. They then undergo periodic audits on their factory, with a full scale fire resistance test every three years. Q Mark Members: When further processing Strebord cores, the finished doorsets must fall within the scope of the global assessment data defined under the Fire Door Applications Sections of this manual to maintain Q Mark accreditation.

v9.1 VARIATIONS: Due to the constant development of the Strebord product, various sections of this manual may be amended from time to time. The variations may take the form of Information Sheets or the replacement of complete sections. This page provides a means for recording variations. Variation Ref: Date Section NOTES 6 Glass and glazing. Inclusion of Vistamatics for FD 30 and FD 60 applications. Tectus hinges 9 Hardware Inclusion of Tectus concealed hinges on FD 30 applications only. Tuscan flush pull handle 9 Hardware Winkhaus Av2 multipoint lock 9 Hardware Sealed Tight Solutions Intumescent Sealed Tight Solutions lock protection Sealed Tight Solutions Glazing option Morland MDF bead option 4 Intumescents Inclusion of the Tuscan Hardware flush pull handle on FD 30 and FD 60 applications. Inclusion of the Winkhaus AV 2 multipoint locking system for FD 30 and FD 60 applications. Inclusion of Sealed Tight Solutions 15x4mm graphite Intumescent seals. Inclusion of Sealed Tight Solutions hardware protection for FD 30 applications only. Inclusion of Sealed Tight Solutions glazing options for FD 30 and FD 60 applications. Inclusion of the Morland MDF bead system for FD 30 applications only. Coverage applied for the use of Streframe timber for glazing beads, FD 30 and FD 60. Permitted to produce an over rebated FD 30 doorset, 34x13mm rebate, European style door. Increase in scope with further testing for Intumescent Seals Ltd. Vistamatic 4 Intumescents 6 Glass and glazing 6 Glass and glazing Streframe beading 6 Glass and glazing Strebord 2 Fire door applications ISL Seals 2 Fire door applications CS Group Various Scope increased for full Acrovyn encapsulation of a doorset.

v9 Contents Section 1 - General specifications. Section 2 - Fire door application data. Section 3 Lippings & Facings Section 4 Intumescent Sealing Section 5 Smoke Sealing - Recommended seal types and location advice. Section 6 Glazing - Glass types with recommended beading options for fire rated doorsets. Section 7 Frames - Recommended minimum frame sections together with lists showing Section 8 Co-ordination - Recommendations for the co-ordination of doorsets; Section 9 Hardware - Recommendations concerning the use of hardware with - Recommended materials and methods. - Recommended seal types and location advice. softwoods and hardwoods with fire door application recommendations. door / frames and doorsets with surrounding structures. fire rated and other doorsets. for the use of Strebord cores for satisfying sound Section 10/10A Acoustics - Recommendations attenuation performance requirements. Also acoustic assessments. Section 11 Mechanical Performance - DD171 / PAS23 Performance data. Section 12 Thermal Insulation - Guidance for the use of Strebord Section 13 Panelled Doors - Recommendations for the use of Strebord Section 14 Fire Doorset Installation - Recommendations for the installation of Section 15 Appendices cores for satisfying U value performance requirements. cores to produce panelled appearance doorsets. fire rated doorsets.