FIRE SAFETY (But Were Afraid To Ask)

Similar documents
BROWARD COLLEGE FIRE SAFETY GUIDE

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Fire Safety Handbook

TAMUCC Fire Safety Training

WSU-TFREC Fire Safety Training

Leader s Guide 2007 CLMI Training

FIRE SAFETY FOR OFFICE WORKERS

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Fire Extinguisher Training

Using Fire Extinguishers. Leaders Guide and Quiz

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

Workplace FIRE SAFETY

"USING FIRE EXTINGUISHERS"

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

Risk Management Department. Fire Extinguishers

E4218 Fire Extinguisher Basic Training. Leader s Guide

What are the four things that must be present at the same time to produce fire?

Emergency Action Plans and Fire Prevention Plans. Are employers required to have Emergency Action Plans and/or Fire Prevention Plans?

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Fire Extinguisher Training

FIRE SAFETY PRACTICES AND PROCEDURES

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Fire Safety. Version 1.0

Salt Lake Community College FIRE EXTINGUISHER TRAINING

Fire Safety Guide. Emergency Number:

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

FIRE SAFETY FOR INDUSTRIAL WORKERS

Fire Safety Guide. Emergency Numbers:

Safe Fire Extinguisher Use

FIRE TETRAHEDRON. Consists of 4 Sides. Oxygen. Fuel. Chain of reaction

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

ADMINISTRATIVE SERVICES MANUAL

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

September Safety Subject

Fire Safety Guide. Emergency Number:

1. PURPOSE 1.1- To describe fire/emergency evacuation plan for the Large Animal Research Unit (LARU).

Emergency Action and Fire Prevention

"FIRE PREVENTION AND SAFETY IN THE OFFICE"

Employers Responsibilities

Portable Fire Extinguishers

Progressive Safety Services LLC 2

WHEN a fire starts, the first few seconds are critical. Thus, fire

Institute for Plasma Research Welcomes you all on

Albert Einstein College of Medicine Department of Environmental Health and Safety

LABORATORY SAFETY SERIES: Planning For Emergencies

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Saginaw Valley State University. General Fire Drill /Evacuation Procedures

"FIRE PREVENTION IN HEALTHCARE FACILITIES"

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

Leader s Guide Marcom Group Ltd.

U.S. Consumer Product Safety Commission Washington, DC 20207

Fire Prevention in Healthcare Facilities. Leaders Guide and Quiz

Lamorinda CERT - Unit 2 09/15/2016

Model Policy On Portable Fire Extinguishers (Ontario Version)

FIRE EMERGENCY POLICY

2010 Fire Log Fire Log. Annual Fire Safety Report

Fire Extinguisher Use. Fire Extinguisher Review. and Fire Safety

Fire Safety Training. Welcome to the Augusta University. Fire Safety Office

Chapter 3: Emergency Planning for Laboratories

"EVACUATION PROCEDURES"

Loyola University Maryland s General Fire EVAC Plan

Safety Manual Section 7 Fire/Life Safety

Safety Manual: Emergency Response

CEDARVILLE UNIVERSITY NON-RESIDENT HALL FIRE RESPONSE & EVACUATION PLAN

Fire Prevention Plan

Fire Prevention Program

Fire Safety PPT-SM-FIRESFTY V.A.0.0

FIRE PREVENTION AND PROTECTION FACT SHEET

Stillwater Area Community Services Center Inc.

TIMOTHY R. SZYMANSKI Instructor

SERT FIRE ELEMENTS & HAZ MAT

The basic fire theory says that a fire needs four main elements in order to start: heat, fuel, oxygen, and a chain reaction. This theory is known as t

Emergency Response Procedures Contractors Instruction. Building nformation

Portable Fire Extinguishers

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

Fire Prevention Plan

During the holiday season, electrical fires are one of the leading causes of damage to residential structures. Specific causes included:

Meagan Ray, RN Safety Director

St. John s University

EMERGENCY ACTION GUIDE. Fire

Safety & Risk Management Policies and Procedures

St. John s University Fire Safety Plan

FIRE SAFETY. Department of Chemical Engineering College of Engineering

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION. Type of Construction: Combustible Non-Combustible

St. John s University

Fire Prevention Policy

Academic and Administrative Buildings

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

Housing Fact Sheets. Home Fire Protection

October 1, Full *2 Sprinkler System

St. John s University

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

St. John s University Fire Safety Plan

Fire Safety and Utility Controls. CERT Basic Training Unit 2

Cadet Entry Level Award(ELA) Part Four. Fire Safety

St. John s University

Emergency Response Guide for Laboratories

Transcription:

Broward College Emergency, Safety & Security Office Everything You Wanted To Know About FIRE SAFETY (But Were Afraid To Ask) 1. Pull fire alarm box 2. Call Campus Safety 954-201 HELP (4357) 3. Dial 9-911 to report fire. 4. Close all doors while exiting to prevent spread of smoke/fire. DO NOT LOCK DOORS 5. If fire is small & confined to the area where it started, secure fire extinguisher, and fight fire. 6. Evacuate! DO NOT USE ELEVATORS 7. Report all fires to EHS Office. INTRODUCTION Fire is the third leading cause of accidental deaths in the United States, yet most people ignore it. More than 150 workplace fires occur every day. Do you know...? How fires start? How fires are classified? How to prevent fires? When not to fight a fire? How to identify the proper fire extinguisher? How to use a portable fire extinguisher? What to do if someone catches on fire? How fires start? How to extinguish small fires? How to inspect your fire extinguishers? How to create an emergency action plan How to evacuate a burning building? What to do if trapped in a burning building? If you answered yes to all those questions, are you willing to take a quiz to prove it? HOW FIRES START Fire is a chemical reaction involving rapid oxidation or burning of a fuel. It needs three elements to occur: FUEL - Fuel can be any combustible material - solid, C liquid or gas. Most solids and liquids become a vapor or gas before they will burn. A B OXYGEN - The air we breathe is about 21 percent oxygen. Fire only needs an atmosphere with at least 16 percent oxygen. HEAT - Heat is the energy necessary to increase the temperature of the fuel to a point where sufficient vapors are given off for ignition to occur. 1

CHEMICAL REACTION - A chain reaction can occur when the three elements of fire are present in the proper conditions and proportions. Fire occurs when this rapid oxidation or burning takes place. Take any one of these factors away, and the fire cannot occur or will be extinguished if it was already burning. HOW FIRES ARE CLASSIFIED CLASS A Ordinary combustibles or fibrous material, such as wood, paper, cloth, rubber and some plastics CLASS B Flammable or combustible liquids such as gasoline, kerosene, paint, paint thinners, propane and cooking oils/grease CLASS C Energized electrical equipment, such as appliances, switches, panel boxes and power tools CLASS D Certain combustible metals, such as magnesium, titanium, potassium and sodium. These metals burn at high temperatures and give off sufficient oxygen to support combustion. They may react violently with water or other chemicals, and must be handled with care. 2

HOW TO PREVENT FIRES Class A Ordinary combustibles: Keep storage and working areas free of trash. Place oily rags in covered containers. Class B Flammable liquids or gases: Don't refuel gasoline-powered equipment in a confined space, especially in the presence of an open flame such as a furnace or water heater. Don't refuel gasoline-powered equipment while it's hot. Keep flammable liquids stored in tightly closed, self-closing, spill-proof containers, U.L. safety can. Pour from storage drums only what you'll need. i.e. Store flammable liquids away from spark producing sources, help to prevent exposure, bond the two containers together to prevent static spark Use flammable liquids only in well-ventilated areas. Class C Electrical equipment: Look for old wiring, worn insulation and broken electrical fittings. Report any hazardous condition to your supervisor. Prevent motors from overheating by keeping them clean and in good working order. A spark from a rough-running motor can ignite the oil and dust in it. Utility lights should always have some type of wire guard over them. Heat from an uncovered light bulb can easily ignite ordinary combustibles. Don't misuse fuses. Never install a fuse rated higher than specified for the circuit. Investigate any appliance or electrical equipment that smells strange. Unusual odors can be the first sign of fire. Don t overload wall outlets. Two outlets should have no more than two plugs. Class D Metals: Flammable metals such as magnesium and titanium generally take a very hot heat source to ignite; however, once ignited are difficult to extinguish as the burning reaction produces sufficient oxygen to support combustion, even under water. In some cases, covering the burning metal with sand can help contain the heat and sparks from the reaction. Class D extinguishing agents are available (generally as a dry powder in a bucket or box) which can be quite effective. These agents are available upon request from the Health & Safety Office. 3

If you are planning a research project using a large amount of flammable metals you should consider requesting a ten pound Class-D extinguisher as a precaution. Pure metals such as potassium and sodium react violently (even explosively) with water and some other chemicals, and must be handled with care. Generally these metals are stored in sealed containers in a nonreactive liquid to prevent decay (surface oxidation) from contact with moisture in the air. White phosphorus is air-reactive and will burn/explode on contact with room air. It must be kept in a sealed container with a non-reactive solution to prevent contact with air. Some of these metals may not be uncommon in labs on Broward College campuses, but are generally only found in small quantities and accidental fires/reactions can be controlled or avoided completely through knowledge of the properties of the metals and using good judgement and common sense. The researcher should be familiar with the characteristics, MSDS, and adverse reactions of the various chemicals he or she is using. WHEN NOT TO FIGHT A FIRE Never fight a fire: If the fire is spreading beyond the spot where it started If you can't fight the fire with your back to an escape exit If the fire can block your only escape If you don't have adequate fire-fighting equipment In any of these situations, DON'T FIGHT THE FIRE YOURSELF. CALL FOR HELP. 4

HOW TO EXTINGUISH SMALL FIRES Class A - Extinguish ordinary combustibles by cooling the material below its ignition temperature and soaking the fibers to prevent re-ignition. Use pressurized water, foam or multi-purpose (ABC-rated) dry chemical extinguishers. DO NOT USE carbon dioxide or ordinary (BC-rated) dry chemical extinguishers on Class A fires. Class B - Extinguish flammable liquids, greases or gases by removing the oxygen, preventing the vapors from reaching the ignition source or inhibiting the chemical chain reaction. Foam, carbon dioxide, ordinary (BC-rated) dry chemical, multi-purpose dry chemical, and halon extinguishers may be used to fight Class B fires. Do not use water to fight a class B fire. Class C - Extinguish energized electrical equipment by using an extinguishing agent that is not capable of conducting electrical currents. Carbon dioxide, ordinary (BC-rated) dry chemical, multi-purpose dry chemical and halon* fire extinguishers may be used to fight Class C fires. DO NOT USE water extinguishers on energized electrical equipment. * Even though halon is widely used, EPA legislation is phasing it out of use in favor of agents less harmful to the environment. Class D - Extinguish combustible metals such as magnesium, titanium, potassium and sodium with dry powder extinguishing agents specially designated for the material involved. In most cases, they absorb the heat from the material, cooling it below its ignition temperature. NOTE: Multipurpose (ABC-rated) chemical extinguishers leave a residue that can harm sensitive equipment, such as computers and other electronic equipment. Because of this, carbon dioxide, or halon or cleaner agent extinguishers are preferred in these instances because they leave very little residue. ABC dry powder residue is mildly corrosive to many metals. For example, residue left over from the use of an ABC dry powder extinguisher in the same room with a piano can seriously corrode piano wires. 5

Carbon dioxide, halon or ABC multipurpose extinguishers are provided for most labs and computer areas on campus. Class K fire extinguishers are wet chemicals and used to extinguish kitchen grease fires. The 10-poind ABC multipurpose fire extinguisher is the standard fire extinguisher for Broward College with the above exception. HOW TO IDENTIFY THE PROPER FIRE EXTINGUISHER All ratings are shows on the extinguisher faceplate. Some extinguishers are marked with multiple ratings such as AB, BC and ABC. These extinguishers are capable of putting out more than one class of fire. Class A and B extinguishers carry a numerical rating that indicates how large a fire an experienced person can safely put out with that extinguisher. Class C extinguishers have only a letter rating to indicate that the extinguishing agent will not conduct electrical current. Class C extinguishers must also carry a Class A or B rating. Class D extinguishers carry only a letter rating indicating their effectiveness on certain amounts of specific metals. Pull the Pin. HOW TO USE A PORTABLE FIRE EXTINGUISHER Remember the acronym, "P.A.S.S." Aim the extinguisher nozzle at the base of the flames. Squeeze trigger while holding the extinguisher upright Sweep the extinguisher from side to side, covering the area of the fire with the extinguishing agent. 6

REMEMBER: Should your path of escape be threatened Should the extinguisher run out of agent Should the extinguisher prove to be ineffective Should you no longer be able to safely fight the fire...then LEAVE THE AREA IMMEDIATELY! HOW TO INSPECT YOUR FIRE EXTINGUISHERS Know the locations of the fire extinguishers in your work area. Make sure the class of the extinguisher is safe to use on fires likely to occur in the immediate area. All fire extinguishers should be checked monthly by the occupants. Check the plastic seal holding the pin in the extinguisher handle. Has the extinguisher been tampered with or used before? Report any broken/missing seals/pins to the Director of Safety Chief Fire Official. Look at the gauge and feel the weight. Is the extinguisher full? Does it need to be recharged? Water, some foam, and dry chemical extinguishers have gauges indicating the pressure inside the extinguisher. The pressure needle should be in the "green" area (generally 100-175 lbs., depending on the type of agent). CO 2 (carbon dioxide) extinguishers are high pressure cylinders with pressures ranging from 1500 lb to 2150 lb. These extinguishers DO NOT have gauges and must be weighed by our Fire Extinguisher contractor to determine the amount of contents remaining. Make sure the pin, nozzle and nameplate are intact. The Fire Extinguisher Contractor under the guidance of the Director of Safety inspects and services all Broward College fire extinguishers on a year-round basis, but we would still encourage you to be aware of the condition of your area's extinguishers by visual inspection on a frequent basis to ensure you have a working extinguisher there when you need one. Report any missing, empty or damaged fire extinguishers to the Health & Safety Office whenever you notice any discrepancies. 7

The APPEARENCE of different types of extinguishers: Generally, you can tell with a glance which type an extinguisher is hanging on the wall, or in the cabinet, just by looking at its shape. Check the labels of the extinguishers in your area and note the color and shape/size of the extinguisher. This may help if someone runs in to help you fight a fire with the WRONG extinguisher (i.e. water on an electrical fire) - you can STOP them before they are injured or make matters worse! ABC-rated multipurpose dry powder extinguishers Are the most common at BC campuses, particularly in the corridors of academic buildings? They are RED in color and have either a long narrow hose or no hose (just a short nozzle). These extinguishers are very light (5-25 lbs total weight) Halon extinguishers look virtually identical to ABC To multipurpose dry chemical extinguishers CO 2 (carbon dioxide) extinguishers are generally red have a LARGE "tapered" nozzle (horn), are HEAVIER (15-45 lbs.) These are all high-pressure cylinders. Care should be used not to drop a CO 2 cylinder; if it is damaged it can punch a hole through the nearest wall(s) and end up on the other side of campus! (The containers are quite sturdy, but don't abuse them) CO 2 cylinders do not have a pressure gauge they must be weighed to determine the amount of contents. "WHERE can I find a fire extinguisher on campus?" In the corridors of academic and office buildings, and inside very large rooms. In or immediately outside all laboratories where chemicals are stored and used. In or immediately outside mechanical spaces where motorized or other equipment is present which might reasonably cause a fire. In electrical closets, storage buildings, and mounted inside certain Broward College vehicles. If you can't find the fire extinguisher in your area, or feel you need different type/size of extinguisher for your work area or laboratory, contact the EHS Office (954-201-6817). "If I just use a little, do I have to report the extinguisher as USED?" YES! We want FULL extinguishers at all BC campus locations. 8

While CO 2 and halon extinguishers will generally hold their pressure after a slight discharge, BC and ABC rated DRY CHEMICAL extinguishers will usually NOT hold a charge after partial use. This is true for all your personal home and vehicle dry chemical extinguishers, too! While the gauge may hold steady in the green immediately after a slight use, check it the next day and you'll find the gauge on EMPTY! This is because upon use the dry powder gets inside the seals and allows the nitrogen carrier to escape over a period of time. After ANY use a BC or ABC extinguisher MUST be serviced and recharged. This is very important for home extinguishers also; YOU MUST HAVE THE EXTINGUISHER REFILLED AFTER ANY USE. You cannot "test" an extinguisher and put it back in the cabinet! If you want to try out an extinguisher and learn how it feels to use one, contact the Safety Office and they'll arrange for you to attend a fire extinguisher classes where you can actually get some hands-on use. Warning to thieves and vandals: Fire extinguishers and types of fire equipment on the Broward College campus are traceable and theft of or damage to emergency equipment is a serious crime. HOW TO EVACUATE A BURNING BUILDING The last one out of the room should not lock the door, just close it. Locking the door hinders the fire department's search and rescue efforts. Proceed to the exit as outlined in the Emergency Action Plan. Follow the exit signs to the exit. Proceed in a calm and orderly manner. If one egress path is blocked by fire and smoke, use the other one. NEVER, NEVER use elevators under any circumstances Stay low to avoid smoke and toxic gases. The best air is close to the floor, so crawl if necessary. If possible, cover your mouth and nose with a damp cloth to help you breathe. If you work in a building with multiple stories, a stairway will be your primary escape route. Most enclosed stairwells in buildings over two stories are "rated" enclosures and will provide you a safe means of exit; don't panic, but descend stairs slowly and carefully. Once in the stairwell, proceed down to the first floor. Never go up. Once outside the building, report to a predetermined safe area, usually 50 feet away, so that a head count can be taken. 9

WHAT TO DO IF TRAPPED IN A BURNING BUILDING If you're trying to escape a fire, never open a closed door without feeling it first. Use the back of your hand to prevent burning your palm. If the door is hot, try another exit. If none exists, seal the cracks around the doors and vents with anything available. If in a room, use wet towels to seal the space under the door and prevent the entry of smoke. Cracks around the door can be sealed with masking tape if necessary. If trapped, look for a nearby phone or use your cell phone and call the Broward College Campus Safety 954-201-HELP (4357), giving them your exact location. If breathing is difficult, try to ventilate the room, but don't wait for an emergency to discover that window can't be opened. If you can't contact the Campus Safety by phone, wave for attention at the window. Don't panic. WHAT TO DO IF SOMEONE CATCHES ON FIRE If you should catch on fire: STOP - where you are DROP - to the floor ROLL - around on the floor This will smother the flames, possibly saving your life. Just remember to STOP, DROP and ROLL. If a co-worker catches on fire, smother flames by grabbing a blanket or rug and wrapping them up in it. That could save them from serious burns or even death. SUMMARY KNOWLEDGE AWARENESS PREPARATION These are your keys to preventing and surviving fires wherever they occur. 10

1. Pull fire alarm box 2. Notify Campus Safety at 954-201-HELP (4357) 3. Dial 9-911 to report fire 4. Close all doors while exiting to prevent spread of smoke/fire. DO NOT LOCK DOORS 5. If fire is small & confined to the area where started, secure fire extinguisher, fight fire. 6. Evacuate! DO NOT USE ELEVATORS. Ensure that everyone is out including those with disabilities. 7. Report all fires to Director of Safety. Everyone must do their part to prevent fires - Plan Ahead 11

QUIZ Can you correctly answer TRUE or FALSE for each question below? 1. Fire requires fuel, oxygen and heat for ignition to occur. Taken any one away and the fire cannot occur. 2. Fire needs an atmosphere of 21 percent oxygen - the same as the air we breathe - to sustain ignition. 3. Class A fires are fueled by ordinary combustible or fibrous material, such as wood, paper, cloth and some plastics. 4. Class B fires include flammable or combustible liquids, greases and gases, such as gasoline, paint and propane. 5. Class C fires include electrical equipment, such as motors and heaters that are not connected to a power source. 6. Combustible metals (Class D) are difficult to extinguish, because once ignited, they give off sufficient oxygen to support combustion. 7. Class D fires can be extinguished with water. 8. Keeping the work area free of litter is one way to help prevent Class A fires. 9. Gasoline-powered equipment can be refueled while hot if refueling is done in a wellventilated area. 10. You may use a higher-amp fuse than is specified for an electrical circuit if you first tag the fuse box to mark the change. 11. Unusual odors from electrical equipment can be the first sign of a potential fire. 12. If the fire you are fighting begins to spread, leave the area and call for help. 13. Do not use carbon dioxide or ordinary dry chemical extinguishers on Class A fires. 14. Do not use water extinguishers on energized electrical equipment. 15. An Emergency Action Plan should designate one person to evacuate all disabled people in the building. 16. Fire drills are necessary to test the Emergency Action Plan. 17. The last person to evacuate a room should lock the door to prevent vandalism or theft of equipment. 18. Elevators may be used to evacuate a building as long as they remain operable. 19. You should occasionally pull the pin and briefly squirt all fire extinguishers to ensure they are properly charged and in good working order. 20. As soon as you evacuate a burning building, go home. No need to hang around. 12

Fire Safety questions may be referred to the Director of Safety and Chief Fire Official Marcus Robinson 954-201-6817 Mrobins2@Broward.edu Answers: 1-T,2-F,3-T,4-T,5-T,6-T,7-F,8-T,9-F,10-F, 11-T,12-T,13-T,14-T,15-F,16-T,17-F,18-F,19-F,20-F 13