SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

Similar documents
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Mark 25 Ultrapure Water Conductivity Analyzer

MODEL ORP/pH Digital Controller

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

Oakton TEMP 9000 Advanced Thermocouple Controller

JDDT1 - Single Stage Digital Thermostat

Owner s Manual PRINTED IN CANADA 05/2009

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Owner s Manual RD432-0 Chemical Controller

RATIO:GUARD Model E-1S EC Monitor

Beacon 800 Gas Monitor Operator s Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Alarm Tone Generator Model AG17

Pump-Up Controller MODEL 4062

M770 ph Controller Owner s Manual

Pump-Down Controller MODEL 4052

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

SEC 2000 Millenium Infrared Gas Detector

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Oakton TEMP 9500 Advanced Multiparameter Controller

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

RC-2000 Thermostat Installation Instructions

EasyTronic III MANUAL SERVICE

Installation, Operation, and Maintenance Instructions. Heatless Regenerative Air Dryers and HLD-PAK Dryer/Filter Packages HLD-25 through HLD-6250

ion Genesis Pump Controller

M790 ph/orp Controller. Owner s Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Static Pressure Control

Owner s Manual. 5+2 Day Programmable Digital Thermostat

RK/ RK Oxygen Detector Operator s Manual

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Pioneer-R16 Gas Monitor Operator s Manual

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

OPERATING INSTRUCTIONS

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

OWNER'S MANUAL T0140. Contents Page #

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

RAM 50 Series Operation Manual

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

flexibility programmed settings.

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

SENSIT HXG-2d Combustible Gas Detector

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL. TPM 001 Revision 0.1

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

AirGard 385 Fume Hood Monitor

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

RK/ RK Carbon Monoxide Detector Operator s Manual

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Owner s Manual. Digital Thermostat

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Controllers. Instruction Manual WARNING

Superdew 3. Hygrometer. Operating Instructions

Refrigerated air dryers

RK CO 2 Transmitter Operator s Manual

HAI Omni-Bus Network Installation. 5. Typical Application

DT968C C.T. BATH CONTROLLER

CRITICAL ENVIRONMENT MONITOR ALNOR AIRGARD 350 CEM

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

M3050 Detector Operator s Manual

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

TEMPERATURE CONTROLLER (STANDARD MODEL)

T8401C Electronic Thermostats

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

CA5000 Liquid CO 2 Freezer Backup System

CG Series Digital Temperature Controller OPERATIONS MANUAL

Model OEM-2 INSTRUCTIONS FOR USE

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Warranty Registration

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

eed quality electronic design USER s MANUAL

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

RAM 50 Series Operation Manual

1 4 DIN Dissolved Oxygen Controller

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

RATIO:GUARD. MODEL P-1 ph INDICATOR/CONTROLLER GETTING TECHNICAL ASSISTANCE

DK-11 Countertop Water System. Owner's Manual

MODEL 4200-IR-2 (Up to 2 Sensors) MODEL 4200-IR-4 (Up to 4 Sensors) MODEL 4200-IR-6 (Up to 6 Sensors)

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

OWNER S Manual PRINTED IN CANADA 10/2009

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Instruction Manual WARNING

RK / RK CO 2 Detector Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

Transcription:

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

INSTALLATION The moisture probe may be installed directly into the sample stream through a ½ inch NPT adapter (See Fig. 1). The penetration into the sample stream can be adjusted at initial installation before making-up the compression fitting. When installation into the sample stream is impractical or not advisable (for reasons of high temperature or when installation of protective filter (coalescing or similar) are required, then the moisture probes may be installed in bypass flow cells (see Fig.1). When moisture probes are installed in bypass flow cells, the sample flow rate should be set between 250 and 500 cc per minute. (Fig.1) 1. Connect the signal cable from the instrument to the mating connector on the probe. Note: The probe can be installed using a maximum cable length of fifteen (15) feet. If a greater length of cable is required, up to a maximum of one thousand (1,000) feet, please contact Nyad Inc. 2. Connect the instrument to a voltage source. Note: Instruments are configured with 115 VAC and 220 VAC. Other specific voltage source are available. ENSURE THE CORRECT VOLTAGE IS APPLIED. CONNECTING TO A VOLTAGE OTHER THAN THAT SPECIFIED MAY CAUSE DAMAGE. Turn on the power switch located on the right side of the unit. The NYAD SERIES 100T MOISTURE ANALYZER will cycle through it s startup routine. The routine is complete when an LED, above the display, illuminates indicating the currently selected operating units and the current moisture measurement is displayed. STARTUP ROUTINE After the instrument and the probe have been installed, connected and power applied, the instrument will proceed through it s startup routine with the display and indicating LED s stepping through the following sequence. Note: Each step is displayed for approximately one second.

a) All display segments ON all LED indicators ON. This tests the display and LED s to ensure all are working. b) NYAD is displayed. c) Operating System Version d) EE 2 is displayed. Indicates processor trying to read external memory for probe calibration data. e) EE 1 is displayed. Indicates processor trying to read redundant internal memory. If no data is found there, the processor turns to internal memory. f) INT is displayed. Indicates all operating data is being taken from internal memory. This will be followed by the internal memory default 9999 g) A four figure number is displayed. This is the last four digits of the serial number of the moisture probe that has it s calibration data transferred into the instrument data memory. On completion of the startup routine the measured moisture value is displayed in units of Dewpoint either C, F, or concentration PPM, as indicated by one of the three yellow LED s located directly above the display panel. If any alarm condition exists, this will be indicated by one or both of the red LED s (Al 1 or Al 2). The alarm condition will indicate six seconds after the measured value is displayed. FRONT PANEL CONTROLS Front Panel Controls permit the selection of functions and changes to be made to units, alarm setpoints, output span, etc. (See Fig 2). 4 3 1 (Fig. 2) 2

The following switches are available on the front panel: OUTPUT 1) UP/UNITS DOWN Push Button. 2) MENU/ALARM SILENCE Push Button. 3) POWER On/Off Switch (Power Switch is not included on OEM model MA-120) 4) LED lights. To connect to 4-20 ma, use the green and orange wires located inside the box. Relay 1 and 2 are provided to connect to external alarms. SETTING ALARM POINTS ( Al 1 and Al 2 ) All Series 100T models have two alarm indication points, Al 1 and Al 2, indicated by the red LED s located above the display. All units have two alarm relays as standard (SPDT) 1A @ 120V. There are no signal or voltage through the relays, just open contacts. The alarm relays are energized when the measured value of moisture exceeds the setpoint value of Al 1 and Al 2 for a sustained period of about six seconds.. a) Find the current Alarm Setpoint values for the selected units. 1) Momentarily depress MENU once Al 1 will be displayed, this will be followed, in about one second, by the alarm 1 setpoint value. If no change is made to the setpoint, then in about six seconds DISP will flash followed by the measured moisture value. 2) Momentarily depress MENU three times A1 2 will be displayed, this will be followed, in about one second, by the alarm 2 setpoint value. If no change is made to the setpoint, then in about six seconds DISP will flash followed by the measured moisture value.. b) Changing Alarm Setpoints:. 1) Depress MENU switch momentarily until A1 1 is displayed followed by alarm 1 setpoint value. To increase the value press UP, to decrease press DOWN. A momentary press and release will change the value by one unit. A press and release followed quickly by a press and hold will scroll the value until the switch is released. When desired value is reached no further action is necessary.. 2) After about six seconds, the display will return to the measured moisture value and the new alarm setpoint will be placed in memory.. 3) Depress MENU switch momentarily until Al 2 is displayed followed by the alarm 2 setpoint value. Proceed as listed above in a) and b) to find or change the value of alarm 2 setpoint.

DEFAULT UNITS NYAD Series 101T Analyzers are preset at the factory with the following default values: FUNCTION C F PPMV FREQUENCY (Hz) AL1-60 -80 10 1000 AL1T HI HI HI AL2 0 32 100 7000 AL2T HI HI HI AL2H 16 AL2L 14 oplo -80 100 0 0 ophi 0 32 100 0000 CON 14.7 14.7 14.7 14.7 CAL 0 TROUBLESHOOTING Below are a list of possible error codes and other issues CODE MESSAGE POSSIBLE CAUSE E-Lo No Signal from Moisture Probe 1. Bad signal cable 2. Sensor Short or Open 3. Receiver malfunction 4. Sensor needs calibration Er-Hi Signal frequency greater than 1. Sample too dry Calibration table values 2. Sensor needs calibration Er-Lo Signal frequency less than 1. Sample too wet Calibration table values 2. Sensor needs calibration EroP Operator Error 1. Output ophi is out of range SYMPTOM CAUSE REMEDY Display hang up Noise induced Reset unit by turning power during operation. program interruption off and on. Display garbled. Faulty display. Power off and on. On power up observe Display. First display all segments. If all display segments are not functioning, replace display. Display shows Probe disconnected, Check probe connection, if E-Lo. bad cable, or sensor O.K. return probe and failure. cable to factory for evaluation. Display shows Sample dewpoint Check for wet sample. Dry Er-Lo. higher than calibration gas should bring unit back on range of sensor. scale. Display shows Sample dewpoint Expose sensor to wet sample. Er-HI. lower than calibration If normal operation resumes range of sensor. recalibration recommended.

Technical Support: Nyad, Inc. will offer Technical Support via telephone or email. All technical support shall be related to the Nyad Equipment only. Any other technical issues involving other products and services to the Nyad Equipment will not be the responsibility of Nyad, Inc. Ph (925) 270-3971 Contact: Sales Email: sales@nyad.com www.nyad.com WARRANTY Nyad, Inc. warrants to the original consumer purchaser that all parts used in the construction or fabrication of the Nyad Equipment will be free from defects in materials and factory workmanship, under normal use and service for five years from the date of delivery. Warranty coverage provides the necessary repairs or parts replacement found by Nyad, Inc. to be defective due to bad workmanship or faulty materials. LIMITATIONS OF WARRANTY The Nyad Equipment is restricted to inspection (FOB the Factory) before warranty is determined, unless other arrangements have been made by Nyad and the original consumer purchaser. This warranty does not apply to routine service/maintenance, repairs and routine calibration of the moisture sensor every twelve (12) months in accordance with manufacturer s recommendation, or replacements made necessary by fire or water damage, or accident to or improper installation by others, alteration, misuse or abuse to the Nyad Equipment. This warranty does not cover labor charges or cost incurred for time and expense by other service agencies or personnel involved in maintaining the Nyad Equipment. Application of this Warranty is further conditioned upon the following: Installation. The Nyad Equipment must be properly installed in accordance with Nyad s installation procedures and instructions. Proper Maintenance and Operation. The Nyad Equipment must be properly maintained and operated in accordance with Nyad s maintenance and operating procedures. All service parts must be acquired from Nyad or its authorized representative. No Alteration. The Nyad Equipment must not have been modified or altered from its original conditions at the date of delivery or installation. Failure to comply with any of these conditions will void this Warranty.