CHCO Double Gas Detector

Similar documents
A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

Control Unit BX280 CONFORMITY EN EN EMC EN Isntallation and user Guide. Firmware Version 9.0

HCF100 Refrigerant FREON R410A, R134a, R407C, R404A

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

GS920 Gas Detector with Earthquake-proof Device

GS920 Gas Detector with Earthquake-proof Device

Gas Detection Probe SG895 ATEX

Gas Detector with Earthquake-proof Device GS920 - V 3

SGF 104 Oxygen Sensor

GL-CO-RFG Channel Gas Leak Alarm System

BX444-M Gas Detector. Features. Application. Operation

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

GS100M Gas Detector. Features. Application. Operation

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

GS100M Gas Detector. Technical Specification

GS300M Gas Detector. Features. Application. Operation

BX444-Mc Gas Detector

GAS MONITOR Model Model

Warranty Registration

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

GS100M Gas Detection Controller

KAE Gas Alarm Operation Manual

Electronic control unit for gas leak detection with 4 detection zones

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USERS MANUAL FOR GAS BOILERS

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

Operating Instructions. For. Alarm Control Module. Model SSR 500

Macurco HD-11 Hydrogen Gas Detector

Instruction Manual. Electronic gas and smoke detector GRM

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

KAB Gas Alarm Operation Manual

Snifter ATEX22 VERSION. User Manual. Distributor

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

XLH210: controller for gas leak detectors

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

Dashley Outdoor Fire Table

IMPORTANT INSTRUCTIONS

GRUNDFOS INSTRUCTIONS UPZCP-3, 4, 6. Multi-zone pump control. Installation and operating instructions

OWNERS MANUAL MODEL 451 (-101 & -201)

C0-210 Carbon Monoxide Probe

Installation and Operating Manual MX 32 2 CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Reference: NPM32GB Revision: B.1

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

BEP Marine Gas Detector FD-2

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

3 Macurco Carbon Monoxide Detector CM-16A

CARBON MONOXIDE DETECTOR, i4h-co-m330

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

Controllers. Instruction Manual WARNING

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Snifter. User Manual. Distributor

M3050 Detector Operator s Manual

INSTRUCTIONS AND WARRANTY

Flame Simulator User Manual. Publication Rev. A

Model 4001 Series Single Channel Controller

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Instruction Manual WARNING

KM300 Carbon Monoxide Detection System Installation Manual

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

THE FIXED AEROSOL EXTINGUISHING SYSTEM - FIRE JACK

ST1. Mod. USE AND MAINTENANCE MANUAL

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

169MHz Telecare Devices Gas & Carbon Monoxide Detector

Dräger REGARD -1 Control System

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Installation Manual KS8-LCP 0-10 C0 2 TRANSMITTER. Instructions for :- KS8-LCP0-10 C02 Sensor

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

Dräger REGARD -1 Control System

RK-05 Combustible Gas Transmitter Operator s Manual

GD Series Gas Alarm Operation Manual

EVD-1 Installation, Operation, and Instruction Manual

Operation & Maintenance Manual

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

MX 15. Installation and Operating. Manual SINGLE CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Part Number: NPM15GB Revision: C.

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

IMR IX176 Portable Gas Detector User Manual

RK / RK Methane Detector Operator s Manual

USE AND INSTALLATION HANDBOOK

Interrupted Ignition Series Oil Primary Control

Warranty Registration

NG-9B NATURAL GAS ALARM

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

03.03.mmm REV.2 09/01

RK Combustible Gas Transmitter Operator s Manual

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Transcription:

Belonging to Made in Italy HO Double Gas Detector HO The HO Detector has been designed and built according to European regulations to detect the presence of toxic and explosive gas. A microprocessor is used to create a complete surveillance and control system with maximum flexibility. Thanks to this and its other features, this detector is suitable for household applications. The HO Detector can detect the presence of two gases. The first gas detected is Methane, with trip sensitivity calibrated at 10% of L.E.L. The second gas detected is arbon Monoxide, when both the maximum O admissible concentration threshold of 300ppm is exceeded, and when low O concentrations persist in the environment for lengthy periods, which according to the principle of accumulation could also damage the human organism. The probe can activate solenoid valves, sirens, and any other signal or alarm handling devices using built-in relays. A series of technical features make this detector extremely versatile, reliable, accurate, and safe. The relay, free of voltage, allows installation of multiple detectors on a single solenoid valve ensuring control of multiple dangerous environments. The detector is complete with a special circuit that controls the sensor s efficiency level, and signals any possible fault. The external container has an IP42 protection degree. FUser i rm w aguide re. Versione 3.1 Firmware Version 1.0 OFORMITY E 50194 E 50291 EI 216-3 E 50270 Important ote Before connecting the unit careful reading of instruction booklet is recommended, and it is kept in a safe place for future reference. Furthermore, the correct electrical connections according to the enclosed drawings, complying with instructions and Regulations in force, is recommended.

Precautions HEK the integrity of the unit after having removed it from the box. heck that the data written on the box correspond to the type of gas used. When doing the electrical connections, follow the drawing closely. Any use of the detector for purposes other than the intended one is considered improper, and as a result of which BEIAT S.r.l. therefore disclaims any responsibility for possible damages caused to people, animals or objects. IMPORTAT: Do not test the device using the gas tap as this does not necessarily provide sufficient concentration to activate the main alarm. TERMS and EXPETATIOS: The installation of the HO gas detector, its ordinary and extraordinary maintenance, every six months, and its out of service removal at the end of the functional life guaranteed by the manufacturer, must be carried out by authorized or specialized personnel. In order to achieve long and satisfactory use of your HO gas detector,, use it by respecting the following precautions. Do not drop it. Heavy knocks or falls during transportation or installation can damage the appliance. Avoid abrupt temperature fluctuations. Sudden temperature variations can cause condensation and the detector could work poorly. Above about +40, the detector could become very sensitive, and generate false alarms. Do not allow it to become wet. The control unit can be seriously damaged as it is not waterproof either when immersed in water or exposed to high levels of humidity. leaning ever clean the device with chemical products. If necessary, wash with a moist cloth. Technical Specifications Power supply... 230Vac 50 Hz +/- 10% Power consumption... 1W hange-over relays for explosive gas detection... 10A 250V ~ resistive 5A 30Vdc resistive hange-over relays for O toxic gas detection... 10A 250V ~ resistive 5A 30Vdc resistive Explosive gas sensor... atalytic Explosion Alarm Threshold... At 10% of L.E.L. O toxic gas sensor... Electrochemical ell O detector alarm sensitivity... 30 300ppm O gas detector alarm threshold according to norm E 50291 on gas accumulation 30 to 300ppm Audible and visual signal alarm by... LED diode and buzzer Sensors faults detected by Fault ircuit... Interruption, short circuit, or wear Functioning Temperature...-10 to +40 Functioning Humidity... 0 90% RH non condensed Electromagnetic ompatibility E Reference orms... E 50270 External degree of protection... IP42 Mounting... External wall mount, or embedded box 503 Body material... ABS self-extinguishing Dimensions... 115x150x52 Warranty... 3 years Operating specifications of the gas sensors The ELETROHEMIAL ELL technology sensor has a duration of: 5 years. The ATALYTI technology sensor has a duration that can vary: from 5 to 6 years. The sensor s functioning temperature, independently of the technology used, ranges from -10 to +40 ATTETIO! The ATALYTI probe does not tolerate a gas detection exceeding 100% of L.E.L., with consequent natural death of the sensor. Each immediate puff of gas that exceeds 100% of L.E.L. takes away months of life from the sensor. To test the toxic gas, issue gas from a pre-calibrated aerosol from 30 to 300 ppm, into the grey sensor. Please see point 6. Using other types of gas is useless and could damage the sensor. The detector must be tested by simulating the presence of gas issuing it from a pre-calibrated aerosol. One per each type, explosive or O. Page 2

omponents and commands 8 Year 2010 S.. 12472 Year 2010 7 6 5 2 4 1 3 HO 9 Replaced by 2014 1 2 3 4 5 6 7 8 1) MAIS connected indication LED. When the unit turns on, this LED blinks and a test of the gas detection sensors efficiency status is carried out. This phase takes about 100 seconds. Afterwards the LED stays on without blinking. During the test period, the HO does not detect the gas. 2) FAULT indication LED. If this LED turns on, it means that one of the gas detection sensors is not working efficiently and must be replaced in an authorized centre. A relay is connected to the fault circuit as well as the light indication and a cricket siren. 3) O ALARM indication LED. This LED will light up when the gas concentration level has reached the 300ppm concentration, or when the accumulation level is reached. The relay contact is closed, and an impulsive sound is issued. 4) Explosive GAS ALARM indication LED. This LED will light up and blink when the gas concentration level has reached 10 % of LEL. The relay contact is closed, and an intermittent sound is issued. 6) atalytic sensor for Methane explosive gas detection. 5) Electrochemical ell sensor for arbon Monoxide detection 7) TEST button. This button is used to simulate a gas leak, after installation. 8) Identification label, registration number and manufacturing year, located under the ABS small dome. 9) Label of the gas sensor expiration date. This label must be applied by the technician during the installation and remembering that the gas sensor must be reviewed after 5 Years. Measures 5 mm 150 mm Embedded box 503 105 mm 70 mm Page 3 34 mm 50 mm 84 mm 115mm

Installation measures and positioning The position of the detector is a crucial factor for its correct functioning during gas detection. In order to obtain the maximum results from a device and minimize the probability of false alarms, it is recommended to follow this scheme and keep in mind the following general regulations. The detector must be located at different heights, according to the type of gas. These heights are: - 30 cm from the highest point of the ceiling in order to detect light gases, Methane - The detector should not be placed near the appliances to be controlled (boilers, burners, industrial kitchens, etc.) but on the opposite wall. - The detector should not be affected by smoke, vapour, etc. as they could distort its measurement. It should be located away from sources of heat, ventilators or fans. Gas detector HO METHAE 1-4 m 30 cm ma x! Rilevatore Gas GPL YES 1-4 m! GAS Detection in ppm 30 cm ma x Detection Diagram 30 ppm O 50 ppm O 100 ppm O 300 ppm O lean Air 0 15 30 45 60 75 90 105 120 135 150 Time in minutes Turn on and testing Install the HO on the wall opposite the possible source of danger, example: kitchens, boilers, or else. Moreover, the detector should not be installed behind barriers that prevent the prompt detection of gas, near vents or fans, and in rooms where temperature falls below -10 or over 40. When powering on the HO, you will see that the MAIS LED lights up and starts blinking for about 100 seconds. Afterward the LED stays on without blinking. ow, the O922 is ready. To test the toxic gas, issue gas from a pre-calibrated aerosol from 30 to 300 ppm, into the grey sensor. Please see point 5,pge 3. Using other types of gas is useless and could damage the sensor. The ALARM LEDs will light up, and the relays will shift their functioning mode. Gas detection sensor in ppm Detection Diagram After the alarm, the LED will turn off, the buzzer will stop, and the connected appliances will be turned off. Page 4

The installation of the detector does not exempt...... from the compliance with all regulations concerning the characteristics, installation and use of gas appliances. Particularly, the ventilation of the spaces and the elimination of combustion products are described in the UI norms according to ART. 3 LAW 1083 / 71 and relevant legal provisions. WARIG! Actions to be taken in case of alarm 1) Put out all free flames. 2) lose the main gas tap or the LPG cylinder tap. 3) Do not turn any lights on or off; do not turn on any electrical device or appliance. 4) Open windows and doors in order to increase ventilation. If the alarm stops, its cause must be found and the relevant consequent measures taken. If the alarm continues and the cause of gas presence cannot be found or removed, abandon the building and call the emergency services when outside (fire department, distributors, etc.) Warning!! If you have the following symptoms: vomiting, sleepiness, or else, go to the closest first aid station and inform the operators that you could have been poisoned by arbon Monoxide. Before calling a technician - If the device does not start up. heck that the 230V power is correctly connected. - If the fault LED lights up. If the YELLOW LED is remains O, check the detection capsule status. It is probably faulty and has to be replaced. all an authorized technician. - If the detector is repeatedly issuing an alarm. heck that there are no gas leaks. If the alarm signal and the FAULT indicator light turn on together, proceed as in the previous paragraph. - If the detector is issuing an alarm and does not shut off the devices connected to it. heck that the wiring is correct and that the jumper that carries power to the relay has been set properly. All relays are free from electrical power. heck the drawing of the connections. If other problems arise, a specialised and/or authorised technician and/or the Distributor of BEIAT S.r.l. should be contacted directly. Page 5

Electrical connections WARIG Before connecting to the mains power, ensure the voltage is correct. arefully follow the instructions and the connections according to Regulations in force, keeping in mind that the signal cables should be laid separate from the power cables. WARIG! The Relay is free of voltage. onnection Scheme of HO Detector 1 2 3 4 5 6 7 8 Power Supply 230 V A Relay Alarm Gas methane R elay Alarme Gas O onnection Scheme normally close valve 230VA WARIG! The Relay is free of voltage. 1 2 3 4 5 6 7 8 Fan Power Supply 230 V A Electrovalve Page 6

onnection Scheme normally open valve 230VA WARIG! The Relay is free of voltage. 1 2 3 4 5 6 7 8 Power Supply 230 V A Electrovalve Fan One or more detectors with a normally open valve 230VA 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 onnection 230V ca One or more detectors with a normally close valve 230VA 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 onnection 230V ca WARIG! The Relay is free of voltage. Page 7

ISURAE. This device is insured by the SOIETÀ REALE MUTUA for the PRODUT'S GEERAL LIABILITY up to a maximum of 1,500,000.00 EURO against damages caused by the device in case of failures in functioning. WARRATY. The warranty term is 3 years from manufacturing date, in agreement with the following conditions. The components acknowledged as faulty will be replaced free of charge, excluding the replacement of plastic or aluminium cases, bags, packing, batteries and technical reports. The device must arrive free of shipment charges to BEIAT S.r.l. Defects caused by unauthorized personnel tampering, incorrect installation and negligence resulting from phenomena outside normal functioning shall be excluded from the warranty. BEIAT S.r.l. is not liable for possible damage, direct or indirect, to people, animals, or things; from product faults and from its enforced suspension of use. Made in Italy HO GAS DETETOR Styling by b&b design TO BE FILLED AFTER ISTALLATIO Purchase Date Stamp and signature of the dealer Registration umber In agreement with our continuous development policy, we reserve the right to modify our products without notice. BEIAT S.r.l. Via G. Bossetto 3-10073, iriè (TO) - ITALY Tel. 011.921.04.84 - Fax 011.921.14.77 E- mail - info@beinat.com - http:// www.beinat.com Symptoms of arbon Monoxide O poisoning ppm 5000 DEATH within 20 minutes 1500 DEATH within 2 hours 800 OVULSIOS within 30 minutes 450 STROG HEADAHE 250 HEADAHE within 3 hours 150 HEADAHE within 2 hours