Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Similar documents
Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CATEGORY 6A FTP RJ45 SOLUTION

Compact Module. Category 6A FTP Cabling System 1.1

FEB. 17 Rev. A1

Multi-Core Fire Resistant Cable

Cat 6 Unshielded Patch cords

Mar11 Rev B

LCS 2 YOUR digital infrastructure

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

/Oct/2014 Rev E

INTERNATIONAL STANDARD

Sonos-SB Siren/Beacon

Cat 6 Shielded Patch cords

/Oct/2014 Rev B

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

Around the cable. Pressing and crimping.... convincing solutions

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

The Next Generation of Data Communicatons Solutions

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

simply fits your needs

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Qualification Test Report 1/Jul/2005 Rev. A

D45. High performance door entry system CATALOGUE. A Group Brand

Type MTS Miniature Test Switches

4-Channel Contact Closure Fiber Link Card System

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

A. The requirements of this Section and the other Division 26, 27 & 28 Sections apply to all the video surveillance system work.

Classification Report

4120 Fire Alarm Network Reference

Index D45 D45. system. Catalogue. System overview 4 Entrance panel overview 6 Internal unit overview 7

P2267 NETWORK INTERFACE

Product Specification CAT 6 UNSHIELDED PATCH CORDS

EASY-WAVE Trash & Linen Chute System Installation

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

PROJECT DATE FLANGE FINISH

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

INTERNATIONAL STANDARD

User Manual Digital Control Station

Instruction Manual SCD24. Read this document prior to installation. Contents

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Product Specification Qualification Test Report

Battery Interconnects

Special Provision No. 683S28 December 2017

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Control and Indicating Equipment

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

PRESENTING OUR NEW RANGE FROM PLATINUM TOOLS

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Call stations and extensions

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

C-Bus Four Channel Analogue Output Unit Installation Instructions

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

INTERNATIONAL STANDARD

Installation & Operating Instructions

C-Bus Four Channel General Input Unit Installation Instructions

Contents. 30 References

Caledonian Flame Retardant Coaxial Cables

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Switches compliant with ATEX directive

24 port 0.5U unpopulated FTP keystone panel with cable management bar

INTERNATIONAL STANDARD

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

INTERNATIONAL STANDARD

Mounting plates for data connection caps

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Fibre Specification Standards

PUBLIC ADDRESS SYSTEM

PlanarMag Product Technology

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Half-Dome. the Design-Tower. Compact

CEE PLUGS AND SOCKETS

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

This document is a preview generated by EVS

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

USER MANUAL FOR OPERATING SYSTEM

Comtran Cable. Hub-LINK Cables for Transit Applications

Elemec3. Networked Public Address and General Alarm System (PA/GA)

Voice Alarm system integration

Architectural and Engineering Specification for a. Flash / Flare

DESCRIPTION INSTALLATION

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

VPS3 Installation Manual

Transcription:

87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 49 5 723 57 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical characteristics...2 5. Connection...2 6. Overall dimensions....2 7. Usual connection of RJ 45 sockets...2 8. Standards and approvals...3 9. Performance.... 3-5 1. GENERAL CHARACTERISTICS Cat. 6A RJ 45 terminal socket for high speed connection to a network. Enables data transmission at 10 Gbit/s. Socket is used with Cat. 6A U/UTP cables. Colour code and Contact number Identification number UTP : SA61 1 2 2. PRESENTATION Désignation Nbre de modules UTP white 1 5 723 49 magnesium 1 5 728 49 white orange cover white green cover magnesium orange cover magnesium green cover 1 5 723 58 1 5 723 59 1 5 728 58 1 5 728 59 Category colour code: Cat. 6A yellow 3. REAL LIFE SCENARIOS Mechanisms can be flush-mounted or surface-mounted. RJ 45 socket safety Cat. 6A UTP white RJ 45 socket safety Cat. 6A UTP magnesium 2 5 723 57 2 5 728 57 not supplied with the mechanism Unlocking 0 334 Technical data sheet: F01499EN/01 Updated : /09/14 Created: 10/04/12 1/5

4. TECHNICAL CHARACTERISTICS 4.1 Material characteristics Contacts: gold/nickel, minimum thickness of gold > 0.8 µm Metal parts: bronze, nickel, platinum, gold PBT polycarbonate 4.2 Electrical characteristics Breakdown voltage 1000 V Contact resistance m Insulation resistance 500 M at 100 V DC Connector tested and guaranteed under PoE restrictions, IEEE 2.3af standard and PoE+, draft standard 2.3at, up to 2500 on-load connections / disconnections. Tests are carried out with 2 simultaneous PoE+ circuits for a minimum total power of 50 W. 4.3 Mechanical characteristics Max. number of connections and disconnections: 5 without refreshing the wiring. Endurance: 2500 movements (plug insertion/withdrawal) IK03 4.4 Climatic characteristics Operating temperature: - C to + 70 C Humid heat cycle 21 days 5. CONNECTION 6. OVERALL DIMENSIONS (cont.) Side view: 5 723 49/58/59-5 728 49/58/59 5 723 57-5 728 57 25,2 7. USUAL CONNECTION OF RJ 45 Accepts the following cable connectors: RJ11 (4 contacts), RJ12 (6 contacts), RJ45 (9 contacts). Double colour code EIA TIA 568 A and B on terminals: L1 L3 EIA 568 A EIA 568 B L2 L1 90 m L2 5 m L3 5 m Conductors supported: - Single-wire: 0.5 to 0.65 mm, AWG 22 to 25 - Multiple-wire: AWG 26 - Polyethylene conductor insulation: max Ø with insulation 1.58 mm. RJ 45 connectors are equipped with a locking nut that does not require the use of a specific tool and which enables re-cabling in the event of error. 6. OVERALL DIMENSIONS Front view: 1 2 5 723 57-5 728 57 5 723 49/58/59-5 728 49/58/59 45 45 45 22,5 Technical data sheet: F01499EN/01 Updated : /09/14 Created : 10/04/12 2/5

7. USUAL CONNECTION OF RJ 45 (cont.) This system allows the wire pairs to be spread easily before mounting them on the connector. 4 9. PERFORMANCE 9.1 Performance of permanent link with cat. 6A U/UTP cable Return loss 3 OK 10 5 Attenuation Spreading cables ensures that each pair is separated by the specified 13 mm. Spreading pairs by 90 in relation to the cable ensures optimum performance. 8. STANDARDS AND APPROVALS Compliant with standards: ISO 111 Second edition EN 50173 Second edition EIA/TIA-568-B.2 NF C 730 Standard 8877-3.7 10 NEXT (Near end Crosstalk Attenuation) 10 1 MHz 500 Mz Technical data sheet: F01499EN/01 Updated : /09/14 Created : 10/04/12 3/5

9. PERFORMANCE (cont.) 9.1 Performance of permanent link with Cat. 6A U/UTP cable (cont.) PS NEXT (Power Sum NEXT) 9.2 Performances canal (Channel) Return loss 10 10 ACR-N (Attenuation to Crosstalk Ratio) - db Attenuation 0 db 10 ACR-F (Equal Level End Crosstalk Attenuation) NEXT (Near end Crosstalk Attenuation) 10 10 Technical data sheet: F01499EN/01 Updated : /09/14 Created : 10/04/12 4/5

9. PERFORMANCE (cont.) 9.2 Performances canal (Channel) (cont.) PS NEXT (Power Sum NEXT) 10 ACR-N (Attenuation to Crosstalk Ratio) - db 0 db ACR-F (Equal Level End Crosstalk Attenuation) 10 Technical data sheet: F01499EN/01 Updated : /09/14 Created : 10/04/12 5/5